Skip to main content
Log in

Strain Cervical Elastography in Pregnancy: Feasibility Study and Its Usefulness in Prediction of Preterm Birth

  • Original Article
  • Published:
Journal of Fetal Medicine

Abstract

Cervix in pregnancy is a biomechanical barrier holding the uterine contents till the time of parturition. The feasibility and reproducibility of assessing cervical tissue stiffness for predicting preterm birth by a standard method using strain cervical elastography were studied here. The prospective study included use of transvaginal strain elastography assessment of cervix at 22–24 weeks in three regions of interest: (1) Endocervical canal and entire cervix in mid-sagittal plane (2) At the level of external os in cross section and (3) at the level of internal os in cross-sectional plane, with constant pressure application each time. Strain ratios were recorded twice for the operator 1 and once by operator 2. Cervical length was also measured according to standard protocol. The measurement of strain ratios was possible in all the 85 included cases. Intra or and inter operator agreement was good for all the 3 ROIs by Kappa analysis and Pearson coefficient. In 10 cases of preterm birth with cervical length ≤ 25 mm, the strain ratios at internal os were observed to be < 1. Strain cervical elastography in pregnancy appears to be a novel, feasible and reproducible technique using a standard method for prediction of preterm birth.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Timmons B, Meredith A, Mahendroo M. Cervical remodeling during pregnancy and parturition. Trends Endocrinol Metab. 2010;21(6):353–61.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  2. Myers M, Feltovich H, Mazza E. The mechanical role of the cervix in pregnancy. J Biomech. 2015;48(9):1511–23.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Kagan KO, Sonek J. How to measure cervical length. Ultrasound Obstet Gynecol. 2015;45:358–62.

    Article  PubMed  CAS  Google Scholar 

  4. Swiatkowska-Freund M, Preis K. Cervical elastography during pregnancy: clinical perspectives. Int J Womens Health. 2017;9:245–50.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Fruscalzo A, Mazza E, Feltovich H, Schmitz R. Cervical elastography during pregnancy: a critical review of current approaches with a focus on controversies and limitations. J Med Ultrason. 2016;43(4):493–504.

    Article  Google Scholar 

  6. Banos N, Julia C, Lorente N, Ferrero S, Cobo T, Gratacos E, Palacio M. Mid-trimester cervical consistency index and cervical length to predict spontaneous preterm birth in a high-risk population. AJP Rep. 2018;8(1):e43–50. https://doi.org/10.1055/s-0038-1636993.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Muller M, Aït-Belkacem D, Hessabi M, Gennisson J, Grange G, Goffinet F, Lecarpentier E, Cabrol D, Tanter M, Tsatsaris V. Assessment of the cervix in pregnant women using shear wave elastography: a feasibility study. Ultrasound Med Biol. 2015;41(11):278–9.

    Article  Google Scholar 

  8. Molina F, GoMez L, Florido J, Padilla M, Nicolaides K. Quantification of cervical elastography: a reproducibility study. Ultrasound Obstet Gynecol. 2012;39:685–9.

    Article  PubMed  CAS  Google Scholar 

  9. Andrade HE, Hassan S, Ahn H, Korzeniewski S, Yeo L, Chaiworapongsa T, Romero R. Evaluation of cervical stiffness during pregnancy using semiquantitative ultrasound elastography. Ultrasound Obstet Gynecol. 2013;41:152–61.

    Article  Google Scholar 

  10. Wozniak S, Czuczwar P, Szkodziak P, Milart P, Wozniakowska E, Paszkowski T. Elastography in predicting preterm delivery in asymptomatic, low-risk women: a prospective observational study. BMC Pregnancy Childbirth. 2014;14:238.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nupur Shah.

Ethics declarations

Conflict of interest

All authors declare that they have no conflict of interest.

Ethical Approval

Approved by Ethics committee, Indraprastha Apollo hospital.

Informed Consent

Patient consents taken after information.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shah, N., Kaul, A. Strain Cervical Elastography in Pregnancy: Feasibility Study and Its Usefulness in Prediction of Preterm Birth. J. Fetal Med. 5, 155–158 (2018). https://doi.org/10.1007/s40556-018-0178-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40556-018-0178-y

Keywords

Navigation