Abstract
Purpose of Review
The aim of this article is to provide an overview of CAD/CAM removable dental prostheses in the treatment of completely edentulous patients.
Recent Findings
Computer-aided design/computer-aided manufacturing protocols continue to evolve in many areas in dentistry including removable complete dentures. Current protocols are advantageous in decreasing the number of clinical appointments needed, which may reduce the distress in elderly with limited access to care. In addition, CAD/CAM complete dentures are fabricated using standardized techniques using high-value quality controlled materials. Laboratory tabletop scanners are being used predominantly for the digitization of conventional impressions or dental casts. Further research is needed to further advance existing intra-oral scanners in digital impressioning of the completely edentulous jaws.
Summary
Use of digital technology in complete denture manufacturing provides prostheses with improved quality such as reduced porosity, polymerization shrinkage, and improved retention. Presence of digital depository data allows replacement dentures to be fabricated in case they are lost or damaged.
Similar content being viewed by others
References
Papers of particular interest, published recently, have been highlighted as: • Of importance •• Of major importance
Vargas CM, Yellowitz JA, Hayes KL. Oral health status of older rural adults in the United States. J Am Dent Assoc. 2003;134(4):479–86.
Douglass CW, Shih A, Ostry L. Will there be a need for complete dentures in the United States in 2020? J Prosthet Dent. 2002;87(1):5–8.
Thalji G, McGraw K, Cooper LF. Maxillary complete denture outcomes: a systematic review of patient-based outcomes. Int J Oral Maxillofac Implants. 2016;31(Suppl):s169–81.
Ramraj C, Quinonez CR. Self-reported cost-prohibitive dental care needs among Canadians. Int J Dent Hyg. 2013;11(2):115–20.
Carlsson GE, Omar R. The future of complete dentures in oral rehabilitation. A critical review. J Oral Rehabil. 2010;37(2):143–56.
Nash KD, Benting DG. Private practice of prosthodontists in the United States: results from the 2008 & 2011 surveys of prosthodontists. J Prosthodont. 2014;23(1):10–20.
Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: fabrication of complete dentures. Int J Prosthodont. 1994;7(1):17–21.
Kawahata N, Ono H, Nishi Y, Hamano T, Nagaoka E. Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil. 1997;24(7):540–8.
Sun Y, Lu P, Wang Y. Study on CAD&RP for removable complete denture. Comput Methods Prog Biomed. 2009;93(3):266–72.
Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig. 2014;18(6):1687–94.
Lee MY, Chang CC, Ku YC. New layer-based imaging and rapid prototyping techniques for computer-aided design and manufacture of custom dental restoration. J Med Eng Technol. 2008;32(1):83–90.
Motovalli S. Review of reverse engineering approaches. Comput Ind Eng. 1998;35(1):25–8.
•• Patzelt SB, Vonau S, Stampf S, Att W. Assessing the feasibility and accuracy of digitizing edentulous jaws. J Am Dent Assoc. 2013;144(8):914–20. This paper reported on the accuracy and precision for current models of intra-oral optical scanners in obtaining digital impressions of the completely edentulous arches.
Besl PJ, McKay ND. A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell. 1992;14(2):239–56.
Yang C, Medioni G. Object modelling by registration of multiple range images. Image Vis Comput. 1992;10(3):145–55.
Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109(6):361–6.
Han W, Li Y, Zhang Y, Lv Y, Zhang Y, Hu P, et al. Design and fabrication of complete dentures using CAD/CAM technology. Medicine (Baltimore). 2017;96(1):e5435.
Inokoshi M, Kanazawa M, Minakuchi S. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J. 2012;31(1):40–6.
Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent. 2012;107(1):34–46.
Infante L, Yilmaz B, McGlumphy E, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent. 2014;111(5):351–5.
•• Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent. 2015;114(6):818–25. This paper provides clinical data comparing the outcomes of digital and conventional dentures in pre-doctoral clinical settings. Higher patients satisfaction and improved retention was reported with digital dentures.
Lozada JL, Garbacea A, Goodacre CJ, Kattadiyil MT. Use of a digitally planned and fabricated mandibular complete denture for easy conversion to an immediately loaded provisional fixed complete denture. Part 1. Planning and surgical phase. Int J Prosthodont. 2014;27(5):417–21.
Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc. 2013;41(6):407–16.
• Schweiger J, Guth JF, Edelhoff D, Stumbaum J. Virtual evaluation for CAD-CAM-fabricated complete dentures. J Prosthet Dent. 2017;117(1):28–33. This is a case-report that provides a demonstration for a workflow that allows a virtual simulated evaluation of the denture set-up. This was completed through integration of an impression occlusion rim and an extra-oral face scan.
Chen H, Yang X, Chen L, Wang Y, Sun Y. Application of FDM three-dimensional printing technology in the digital manufacture of custom edentulous mandible trays. Sci Rep. 2016;6:19207.
Pang X, Zhuang X, Tang Z, Chen X. Polylactic acid (PLA): research, development and industrialization. Biotechnol J. 2010;5(11):1125–36.
Athanasiou KA, Niederauer GG, Agrawal CM. Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers. Biomaterials. 1996;17(2):93–102.
Anitha R, Arunachalam S, Radhakrishnan P. Critical parameters influencing the quality of prototypes in fused deposition modeling. J Mater Process Tech. 2001;118:–385.
Neumeier TT, Neumeier H. Digital immediate dentures treatment: a clinical report of two patients. J Prosthet Dent. 2016;116(3):314–9.
Hinze M, Thalmair T, Bolz W, Wachtel H. Immediate loading of fixed provisional prostheses using four implants for the rehabilitation of the edentulous arch: a prospective clinical study. Int J Oral Maxillofac Implants. 2010;25(5):1011–8.
•• Baba NZ, AlRumaih HS, Goodacre BJ, Goodacre CJ. Current techniques in CAD/CAM denture fabrication. Gen Dent. 2016;64(6):23–8. A comprehensive review that describes 5 currently available digital dentures manufacturing techniques.
Wimmer T, Gallus K, Eichberger M, Stawarczyk B. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent. 2016;115(5):541–6.
Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2016;116(2):249–56.
• AlHelal A, AlRumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. Comparison of retention between maxillary milled and conventional denture bases: a clinical study. J Prosthet Dent. 2016. This in-vitro study provides comparative data regarding retention of conventionally and digitally manufactured complete dentures. Results demonstrated better retention with digital dentures.
Lechner SK, Lautenschlager EP. Processing changes in maxillary complete dentures. J Prosthet Dent. 1984;52(1):20–4.
Steinmassl PA, Wiedemair V, Huck C, Klaunzer F, Steinmassl O, Grunert I, et al. Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig 2016.
• Bidra AS, Farrell K, Burnham D, Dhingra A, Taylor TD, Kuo CL. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: clinical and patient-centered outcomes. J Prosthet Dent. 2016;115(5):578–586.e1. A prospective trial where clinical and patient-centered outcomes for CAD/CAM monolithic dentures (AvaDent dentures) fabricated in 2 visits were evaluated. Favorable outcomes were reported.
Schwindling FS, Stober T. A comparison of two digital techniques for the fabrication of complete removable dental prostheses: a pilot clinical study. J Prosthet Dent. 2016;116(5):756–63.
Saponaro PC, Yilmaz B, Heshmati RH, McGlumphy EA. Clinical performance of CAD-CAM-fabricated complete dentures: a cross-sectional study. J Prosthet Dent. 2016;116(3):431–5.
Saponaro PC, Yilmaz B, Johnston W, Heshmati RH, McGlumphy EA. Evaluation of patient experience and satisfaction with CAD-CAM-fabricated complete dentures: a retrospective survey study. J Prosthet Dent. 2016;116(4):524–8.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Human and Animal Rights and Informed Consent
This article does not contain any studies with human or animal subjects performed by any of the authors.
Additional information
This article is part of the Topical Collection on Digital and Esthetic Dentistry
Rights and permissions
About this article
Cite this article
Thalji, G., Jia-mahasap, W. CAD/CAM Removable Dental Prostheses: a Review of Digital Impression Techniques for Edentulous Arches and Advancements on Design and Manufacturing Systems. Curr Oral Health Rep 4, 151–157 (2017). https://doi.org/10.1007/s40496-017-0137-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40496-017-0137-z