Skip to main content
Log in

Volt–Time Curve Prediction of Distribution Insulators Under Standard and Typical Lightning Overvoltages Using the Disruptive Effect Method

  • Published:
Journal of Control, Automation and Electrical Systems Aims and scope Submit manuscript

Abstract

Through the development of detection and measurement systems for lightning strokes, the possibility arose for the identification of the characteristic parameters of lightning current and the resulting voltage waveforms that stress the power system insulating equipment. The real lightning voltages that stress the insulation may vary over a wide type of waveforms and may also differ significantly from the standard 1.2/50 \(\upmu \hbox {s}\) lightning impulse voltage. Therefore, the prediction of volt–time characteristics of any insulating material for such non-standard voltages is required for a proper insulation design. In this regard, this paper aims at evaluating the dielectric behaviour of medium voltage insulators subjected to voltage impulses with standard and non-standard waveforms, by applying the disruptive effect method. The non-standard lightning overvoltage waveforms considered in this study were based on lightning overvoltages produced by real return stroke current waveforms observed on conveyed measurement data. The investigation involves a comparison between measured and predicted voltage-time characteristics of insulators, considering single-peaked and double-peaked non-standard impulsive voltage waveforms as well as the standard lightning impulse voltage. Three different types of insulating arrangement involving 15- and 25-kV pin-type porcelain insulators were investigated. The estimation of the parameters required for this prediction method was performed using a simulation language available at ATP/ATPDraw software called MODELS.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17

Similar content being viewed by others

References

  • ABNT. (1992). ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Rio de Janeiro: NBR 6936, Técnicas de ensaios elétricos de alta-tensão.

  • Ancajima, A., Carrus, A., Cinieri, E., & Mazzeti, C. (2007). Optimal selection of disruptive effect models parameters for the reproduction of MV insulators volt–time characteristics under standard and non standard lightning impulses. In IEEE Power Tech, Lausanne, Switzerland. doi:10.1109/PCT.2007.4538411.

  • Ancajima, A., Carrus, A., Cinieri, E., & Mazzetti, C. (2010). Behaviour of MV insulators under lightning-induced overvoltages: Experimental results and reproduction of volt–time characteristic by disruptive effect models. IEEE Transactions on Power Delivery, 25(1), 221–230. doi:10.1109/TPWRD.2009.2033956. (ISSN 0885-8977).

    Article  Google Scholar 

  • Biasotto, E., Oleskovicz, M., Coury, D. V., & Santos, C. J. (2014). Proposal for a new structural and electrical crossarm standard for 15 kV distribution networks. Journal of Control, Automation and Electrical Systems, 25(4), 516–526. doi:10.1007/s40313-014-0123-9.

  • Braz, C. P., Piantini, A., Shigihara, M., & MARIO RAMOS, C. E. S. (2014). Analysis of different procedures for the applications of the disruptive effect model to distribution insulators subject to short tail lightning impulses. Electric Power Systems Research Journal, 113, 165–170.

    Article  Google Scholar 

  • Caldwell, R. O., & Darveniza, M. Experimental and analytical studies of the effect of non-standard waveshapes on the impulse strength of external insulation. IEEE Transactions on Power Apparatus and Systems, PAS-92(4), 1420–1428 July 1973/January 2007. ISSN: 0018-9510. DOI:10.1109/TPAS.1973.293550.

  • Chisholm, W. A. (2008). New challenges in lightning impulse flashover modeling of air gaps and insulators. IEEE Electrical Insulation Magazine, 26(2), 14–25.

    Article  MathSciNet  Google Scholar 

  • Chowdhuri, P., et al. (1994). The effects of nonstandard lightning voltage waveshapes on the impulse strength of short air gaps. IEEE Transaction on Power Delivery, 9(4), 1991–1999. doi:10.1109/61.329531.

    Article  Google Scholar 

  • CIGRÉ. (1992). Working Group 33.07, Guidelines for the evaluation of the dielectric strength of external insulation, CIGRÉ Tech. Brochure 72. Paris: International Council on Large Electric System.

  • CIGRÉ. (2013). In2013 International Symposium on Technical brochure on lightning parameters for engineering applications: Lightning protection (XII SIPDA). Brazil: Belo Horizonte. ISBN 978-1-4799-1343-5. doi:10.1109/SIPDA.2013.6729246.

  • Darveniza, M., & Vlastos, A. E. (1988). The generalized integration method of predicting impulse volt–time characteristics for non-standard wave shapes—a theoretical basis. IEEE Transactions on Electrical Insulation, 23(3), 373–381. doi:10.1109/14.2377.

  • IEC. (2010). INTERNATIONAL ELECTROTECHNICAL COMMISSION- IEC 60060-1: High voltage test techniques—Part 1: General definitions and test requirements. Geneva.

  • IEEE. (2010). Guide for Improving the Lightning Performance of Electric Power Overhead Distribution Lines, IEEE Std. 1410. In IEEE Working Group on the Lightning Performance of Distribution Lines.

  • IEEE. (2005). LIGHTNING AND INSULATOR SUBCOMMITTEE OF THE T&D COMMITTEE. In Parameter of Lightning Strokes: A Review. IEEE Transactions on Power Delivery (Vol. 20, n. 1). ISSN: 0885-8977. doi:10.1109/TPWRD.2004.835039.

  • Jones, A. R. (1954). Evaluation of the integration method for analysis of nonstandard surge voltages. Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 73(2), 984–990. doi:10.1109/AIEEPAS.1954.4498919.

  • Kind, D. (1958). The formative area of technical electrode configurations under impulse voltage stress (in German). Elektrotechnische Zeitschrift, 79(A), 65–69.

    Google Scholar 

  • Kuffel, E., Zaengl, W. S., & Kuffel, J. (2000). High voltage engineering: Fundamentals (2nd ed.). [S.l.]: Newnes, ISBN: 0-7506-3634-3.

  • Paulino, J. O. S., Barbosa, C. F., Lopes, I. J. S., & Boaventura, W. C. (2015a). Assessment and analysis of indirect lightning performance of overhead lines. Electric Power Systems Research Journal, 118, 55–61.

    Article  Google Scholar 

  • Paulino, J. O. S., Barbosa, C. F., Lopes, I. J. S., do Couto Boaventura, W., & de Miranda, G. C. (2015b). Indirect lightning performance of aerial distribution lines considering the induced-voltage waveform. IEEE Transactions on Electromagnetic Compatibility, 57(5), 1123–1131. doi:10.1109/TEMC.2015.2421315.

  • Shigihara, M., Piantini, A., Ramos, M. C. E. S., Braz, C. P., Mazzetti, C., & Ancajima, A. (2016). Comparison of different procedures to predict the volt-time curves of 15 kV insulators. Electric Power Systems Research. doi:10.1016/j.epsr.2016.10.023.

  • Silveira, F. H., & Conti, D. E. (2012). Lightning overvoltage due to first strokes considering a realistic current representation. IEEE Transactions on Electromagnetic Compatibility, 52(4), 929–935. doi:10.1109/TEMC.2010.2044042.

    Article  Google Scholar 

  • Savadamuthu, U., Udayakumar, K., & Jayashankar, V. (2002). Modified disruptive effect method as a measure of insulation strength for non-standard lightning waveforms. IEEE Transactions on Power Delivery, 17, 510–515. doi:10.1109/61.997927.

    Article  Google Scholar 

  • Witzke, R. L., & Bliss, T. J. (1950). Coordination of lightning arrester location with transformer insulation level. ibidem, 6(Pt. I), 964–975.

    Google Scholar 

Download references

Acknowledgements

The authors would like to thank CAPES—Brazilian Federal Agency for Support and Evaluation of Graduate Education for the financial support. Thanks are also due to the educational institutions IFMG, UFU and UFMG for technical and scientific support. Special thanks are due also to the company SAE TOWERS Brasil Torres de Transmissão Ltda for the technical and financial support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. R. Rodrigues.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Rodrigues, A.R., Guimarães, G.C., Boaventura, W.C. et al. Volt–Time Curve Prediction of Distribution Insulators Under Standard and Typical Lightning Overvoltages Using the Disruptive Effect Method. J Control Autom Electr Syst 28, 259–270 (2017). https://doi.org/10.1007/s40313-016-0297-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40313-016-0297-4

Keywords

Navigation