Introduction

Multi-enzymatic processes are becoming increasingly attractive for the oxidation of a wide range of complex organic fuels, due to their possible applications [1]. Oxidation with multi-enzymatic bioanodes improves the amount of energy derived per unit of mass substrate, reducing the amount of fuel consumed and possibly increasing the current density, in addition to generating electricity from two or more types of fuel in a mixed solution [2]. In this sense, the development of multi-enzymatic bioanodes continues to be an important research topic, due to enzyme diversity and the wide range of fuels that can be used (such as alcohols and sugars). Even, these systems can be employed in microfluidic fuel cell prototypes for biomedical applications [3,4,5,6], with enzymes such glucose oxidase (GOx) and alcohol dehydrogenase (ADH) enzymes immobilized on the same bioanode.

Specifically, microfluidic fuel cells that use enzymes on the electrodes are bio-electrochemical systems that generate electrical current from a variety of organic liquid fuels and oxidants under laminar flow regimen with a low Reynolds number and a high Peclet number [7,8,9,10], and their potential uses have attracted the attention driven to energy conversion, where reactions are catalysed by redox enzymes; however, still have the challenge of generating clean energy [11,12,13]. Secondly, enzymes are biocompatible and biodegradable catalysts, operating under mild conditions in water, with high rates and selectivity [14]. For energy applications, the catalytic activity of an enzyme immobilized on the electrode surface is an important factor for achieving a high power output of the device [15]. The creation of electrodes modified with enzymes, which depend on the enzymatic immobilization and the conservation of their activity, used for the bioelectrocatalytic process in microfluidic fuel cells is an important challenge to overcome [16,17,18,19,20,21,22].

The most used enzyme in fuel cells is glucose oxidase (GOx), which oxidizes glucose into gluconolactone at the anode [23]. A wide variety of materials have been used for the immobilization of this enzyme such as carbon nanotubes [24,25,26], graphene [27], polymers [24, 25], metallic nanoparticles [27, 28], etc. However, there are two important limitations of GOx immobilized on solid electrodes: poor electrical communication between the GOx active site and electrode surface, and enzyme leaching [29]. The preparation of suitable electrode array is very important for overcoming these issues. However, the electrode array should not alter the mechanical stability and catalytic capacity of Gox [30].

Nevertheless, the alcohol dehydrogenase enzyme (ADH) is an oxidoreductase that catalyses the reversible oxidation of alcohols to their corresponding carbonyl compounds [31] using nicotinamide adenine dinucleotide (NAD+) as a coenzyme. The reduced form of this coenzyme, NADH + H+, generated in the enzymatic reaction is oxidized back to NAD+ on the electrode surface at a suitable potential [32, 33].

The critical point in the design of electrodes based on a co-immobilization of these two enzymes is to achieve that they can perform the oxidation of their corresponding fuel when they are on the same electrode since each enzyme has a different chemical composition. Finding suitable immobilization methods, where there is a possibility of electronic transfer between the redox groups of the mediator and the electrode, is a key factor for the efficient development of bioelectrodes for microfluidic fuel cells to increase the power density and stability of microfluidic devices using enzymatic electrodes. Therefore, a bioelectrode based on GOx-ADH enzymes was developed in this research, using functionalized carbon nanofibres, tretrabutylammonium bromide and Nafion, applied in a microfluidic fuel cell using different fuels containing glucose and/or ethanol (red wine, rosé wine, white wine, etc.). Using different characterizations, it was possible to demonstrate that enzymes remain active when they are immobilized together, finding the optimum parameters of pH and temperature for each enzyme. Using the scanning electrochemical microscopy technique, it was possible to obtain images of the bioelectrode topography and show increases in the current density when the corresponding substrate was used for each enzyme. The results show the versatility of the electrode to be able to use different fuels composed of ethanol and glucose, obtaining good performance.

Experimental

Reagents

Alcohol dehydrogenase (EC 1.1.1.1 initial activity ≥ 300 U mg-1 protein from Saccharomyces cerevisiae), glucose oxidase (EC 1.1.3.4 Type X-S, lyophilized powder, 100,000-250,000 units/g solid from Aspergillus niger), tetrabutylammonium bromide (TBAB), carbon nanofibres (CNFs) potassium phosphate dibasic dihydrate (K2HPO4), β-nicotinamide adenine dinucleotide sodium salt (NAD+), potassium phosphate monobasic monohydrate (KH2PO4), Nafion® (5% diluted in water), and potassium hydroxide (88.7%) were purchased from Sigma-Aldrich.

Functionalization of carbon nanofibers (CNFs)

CNFs were treated with HNO3/H2SO4 (1:3) for 3 h at 40 °C in a water bath sonicator. Then, the mixture was centrifuged, and the precipitate was washed with deionized water to pH 7.0 and dried at 90 °C for 8 h to obtain carboxylic group functionalization [34].

Bioanode preparation

Three different bioanodes were constructed for the measurements, one with glucose oxidase as biocatalyst, another with alcohol dehydrogenase and the third with a co-immobilization of both enzymes. For GOx and ADH bioanodes, inks with the following components were prepared: 1 mg of enzyme, 1 mg of functionalized CNFs, 10 μL of Nafion, 500 μL of buffer phosphate pH = 7, and 10 mg of TBAB. The ink for the bioanode using GOx-ADH co-immobilization was prepared using 0.5 mg of glucose oxidase, 0.5 mg of alcohol dehydrogenase, 1 mg of functionalized CNFs, 10 μL of Nafion, 500 μL of buffer phosphate pH = 7, and 10 mg of TBAB. All inks were sonicated for 20 min and mixed using a vortex for 15 min. Each ink was deposited by immersion for 12 h onto Toray carbon paper (EC-TP1-060T), whose dimensions were 3 × 10 mm, for electrochemical and test evaluation. The GOx-ADH bioanode was physicochemically characterized via SEM using a JEOL JSM-7401F field emission scanning electron microscope.

Cathode preparation

The abiotic cathode Pt/C for microfuel cell was prepared using commercial Pt/C (30% E-TEK) supported on Toray carbon paper; 120 μL of isopropyl alcohol and 14 μL of Nafion were added per mg of Pt/C, mixed for 30 min and incorporated directly over the electrode surface via homogeneous deposition using an airbrush.

Spectrophotometric determination of activity: alcohol dehydrogenase

The determination of activity of the immobilized ADH enzyme followed a method used by Enzymatic Assay of Alcohol Dehydrogenase EC 1.1.1.1 of Sigma-Aldrich. The evaluation of two types of electrodes by triplicate, one containing ADH and other ADH-GOx immobilized on Toray carbon paper to determine the effect of the activity when the enzyme is immobilized individually and together with the enzyme glucose oxidase. A solution of enzyme diluent (10 mM sodium phosphate buffer, pH 7.5 with 0.1% (w/v) bovine serum albumin) was prepared using a 1 mg/mL solution of bovine serum albumin in a 10 mM sodium phosphate buffer, pH 7.5. Two types of reaction mixtures were prepared: a blank reaction mixture (1.3 mL of a 0.1 M phosphate buffer pH = 8.86, 1.5 mL of 15 mM NAD+, 0.1 mL of 95% (v/v) ethanol, and 0.1 mL of enzyme diluent) and a test reaction mixture (1.3 mL of a 0.1 M phosphate buffer pH = 8.86, 1.5 mL of 15 mM NAD+, and 0.1 mL of 95% ethanol, where the electrode was placed with a dimension of 1 × 1 cm) and was recorded at 340 nm. The millimolar extinction coefficient of β-NADH at 340 nm is 6.22. The average of the experiments is reported with its respective standard deviation value.

Spectrophotometric determination of activity of glucose oxidase enzyme

The GOx activity for the two types of electrodes, one containing GOx and another containing ADH-GOx immobilized on Toray carbon paper, was determined by quantifying the amount of hydrogen peroxide produced using 3,30,5,50-tetramethylbenzidine (TMB) as a co-substrate.

$${\text{Glucose }}\;{\text{oxidase}} + {\text{H}}_{2} {\text{O}}\mathop{\longrightarrow}\limits^{{{\text{Glucose}}\;\;{\text{oxidase}}}} {\text{Gluconic}}\;{\text{acid}} + {\text{ H}}_{2} {\text{O}}_{2}$$
$${\text{H}}_{2} {\text{O}}_{2} + {\text{ TMB}} \mathop{\longrightarrow}\limits^{{{\text{Horseradish }}\;{\text{peroxidase}}}}{\text{Oxidized}}\;{\text{TMB}}$$

The determination of GOx activity is performed in two steps. In the first step, glucose is oxidized by dissolved oxygen in the presence of GOx to produce H2O2, while in the second step, this H2O2 oxidizes TMB by horseradish peroxidase. A solution was prepared containing 5 mM d-glucose, 30 µL of TMB, and 1.4 mL of a peroxidase solution (4.3 mg mL−1) in a 0.1 M phosphate buffer pH 7.0, where the electrode (1 × 1 cm) was incubated, and absorbance was measured at 450 nm [35]. Peroxidase has a significant potential for practical application and can be used as a diagnostic kit for hydrogen peroxide (H2O2) and glucose [36]. For estimating the enzymatic activity, the molar extinction coefficient for TMB of 5.9 × 104 M−1 cm−1 was used, where one unit of glucose oxidase activity (U) was defined as the amount of enzyme required to catalyse the oxidation of 1 mol of a-d-glucose per minute (pH 7.0, 25 °C).

Electrochemical characterization

Electrochemical characterization was performed by cyclic voltammetry using a BioLogic VSP Potentiostat/Galvanostat and a three-electrode electrochemical cell. Toray slides (ETEK) dimensions modified with biocatalysts were used as working electrodes; the Ag/AgCl sat. KCl as reference and, a graphite rod as the counter electrode. Phosphate buffer solutions were deaerated with nitrogen gas (Infra 5.0 UAP).

The enzymatic activity of GOx and ADH immobilized in the bi-enzymatic anode was investigated via scanning electrochemical microscopy (SECM) using a Biologic scanning system instrument model ac-SECM/SECM470, employing a four electrode cell consisting of a platinum ultramicroelectrode (UME) of 25 µm diameter, a reference electrode of Ag|AgCl|3 M KCl, with a graphite rod as an auxiliary electrode and a developed bioanode electrode that was attached to a graphite electrode using a conductive carbon tape. The SECM tip was positioned next to bioelectrode in the electrochemical cell by means of visual control. Subsequently, a z-approach curve was performed in a 5 mM solution of K3[Fe(CN)6] in 0.1 M phosphate buffer at 150 mV of constant potential. A potential surface tilt between sample and scanning plane was compensated using a software tool which is determining a plane parallel to the sample surface by means of three consecutive z-approach curves. The z-position of the SECM tip is then adjusted during scanning in that way that the scanning plane remains parallel to the determined plane of the sample surface.

Schematic representation of the microfluidic fuel cell architecture (mFFC)

Microfuel cell was constructed using poly-(methyl methacrylate) (PMMA) for the fuel and oxidant channels; the cathode electrode was incorporated as a wall to obtain the major O2 quantity for the reduction reaction. The bioanode was in a transverse position to the fluid flow direction. The external contact was performed using a pogo pin, the sealing layers were made of a silicone elastomer film (Silastic®) and cut using the cutter plotter (Grapthec America Inc.). The fuels used were glucose, ethanol, and a glucose-ethanol mix solution at different concentrations using an electrolyte support of buffer phosphate at different pH values. The performance of the microfluidic fuel cell was tested using O2-saturated 0.3 M KOH in the cathodic compartment. The schematic representation of the mFCC and the bi-enzymatic bioanode is shown in Fig. 1. In addition, the evaluation of mFFC was also performed using different alcoholic beverages (brandy, tequila, whisky and vodka). The geometric area was 0.014 cm2 and was maintained for all anodic arrays tested herein. The flow rate was 60 µL min−1 for both streams. All experiments were performed by triplicate and the average ± standard deviation value is reported.

Fig. 1
figure 1

a Scheme of the microfluidic fuel cell and components, using a Pt/C cathode, bi-enzymatic bioanode array composed of Toray paper as electrode with functionalized carbon nanofibers, TBAB, Nafion, glucose oxidase and alcohol dehydrogenase enzymes. b Schematic representation of the prepared bioanode

Results and discussion

Scanning electron microscopy (SEM) was used to perform a superficial evaluation of the bare Toray paper (Fig. S1a in Supplementary information), functionalized carbon nanofibers deposited onto the surface of Toray carbon paper (Fig. S1b) and the bi-enzymatic electrode, where the catalytic ink of GOx, ADH, TBAB and Nafion was deposited on the tubular structure of the electrode formed by the functionalized carbon nanofibers on Toray carbon paper (Fig. S1c). Is reported that enzymatic immobilization on porous support followed by its fixation on the porous wall, where the diffusion rate of the enzyme is slower than the immobilization rate, obtaining a greater retention of the proteins [37]. It is known that enzymatic immobilization on porous support implies the incorporation of the enzyme on the support pores followed by its fixation on the porous wall.

Electrochemical characterization

The cyclic voltammetry technique was used to identify the oxidation and reduction peaks of the bi-enzymatic bioanode corresponding to the cofactors of the enzymes, flavin adenine dinucleotide (FAD+) for glucose oxidase and nicotinamide adenine dinucleotide (NAD+) corresponding to the enzyme alcohol dehydrogenase (Fig. 2). The experiment was performed using the electrode with three different solutions: 0.01 M glucose in 0.1 M phosphate buffer solution, 0.01 M ethanol in 0.1 M phosphate buffer and a mixture of fuels (0.01 M glucose + 0.01 M ethanol in the same phosphate buffer solution). All solutions were at pH 7. As shown in Fig. 2, whereas when the glucose fuel is present, the redox peaks of FAD+ and FADH appear at −0.48 and −0.55 V, respectively, vs. Ag/AgCl. However, the redox pair corresponding to NAD+ and NADH located at −0.28 and −0.34 V, respectively, vs. Ag/AgCl appear in the case of ethanol. When using a mixture of fuels, the oxidation and reduction of the two cofactors, corresponding to the two enzymes can be observed, which indicates that the bi-enzymatic bioanode can oxidize these two fuels. The glucose oxidation reaction shown in Fig. 3a at different glucose concentration was verified by differential pulse voltammetry (DPV) at −0.1 to 0.4 V vs Ag/AgCl, (240 s of stabilization time). Oxidation peaks located between the −0.6 and −0.5 V vs Ag /AgCl can be observed. Inset in Fig. 3b shows the change of current density as a function of glucose concentration.

Fig. 2
figure 2

Cyclic voltammograms of the redox FAD+ and NAD+ of bi-enzymatic bioanode, in the presence of 0.01 M ethanol and 0.01 M glucose in 0.1 M phosphate buffer pH 7

Fig. 3
figure 3

a Differential pulse voltammograms of bi-enzymatic electrode in phosphate buffer solution pH 7, at different glucose concentration; 20 mV s−1 scan rate; 100 mV of amplitude and 2000 ms of press width. b Current density as function of glucose concentration

Evaluation of enzymatic activity of GOx and ADH

Enzymatic activity was carried out to evaluate three types of electrodes, two of which with GOx and ADH enzymes immobilized separately, and the third electrode consisted in bi-enzymatic bioanode (GOx-ADH). Both enzymes were immobilized using the same method.

Figure 4a shows the evaluation of the effect of pH on the activity of GOx immobilized separately and together with the enzyme ADH. For both cases, the optimum pH of the enzyme was in the range of 6–7, and at the pH basic solution, it showed a loss of residual activity of more than 50% at pH 9. At pH 6.5, GOx immobilized on the bi-enzymatic electrode showed a decrease in activity compared with when it is immobilized alone. The pH of glucose oxidase in a free state is 5.5 (Sigma-Aldrich), and when it is immobilized using the proposed method, the pH changes to 6.5 [38].

Fig. 4
figure 4

Evaluation of the effect of pH on the activity of a glucose oxidase enzyme and b alcohol dehydrogenase immobilized separately and together. Evaluation of the effect of temperature on c glucose oxidase enzyme and d alcohol dehydrogenase immobilized separately and together

The effect of pH was evaluated for the activity of immobilized enzyme alcohol dehydrogenase (Fig. 4b). The optimum pH for the two electrodes (ADH immobilized separately and in conjunction with the glucose oxidase enzyme) was between 8 and 9.5, with a maximum residual activity at 9, whose value is similar to that previously reported for the enzyme in the free state at 8.86 [39]. These characterizations served to establish that the enzyme glucose oxidase immobilized by the proposed method has a maximum activity at neutral pH, whereas the enzyme alcohol dehydrogenase at alkaline pH presents an approximately 75% of residual activity for ADH. The enzyme immobilised on the electrode exhibited an activity of 132 U/cm2 of glucose oxidase corresponding to 100% residual activity. For the case of the alcohol dehydrogenase enzyme, 100% residual activity corresponds to 257 U/cm2.

The evaluation of the effect of temperature on the activity of the GOx and ADH enzymes immobilized separately and together (Fig. 4c, d) from 25 to 50 °C was also carried out. It was observed that the electrodes can operate at a temperature from 25 to 35 °C, which showed a positive application in a microfluidic cell that operated at room temperature with a low catalytic activity loss of both enzymes. There is a small decrease in activity when both enzymes are immobilized on the same electrode compared to when they are immobilized separately [40].

Topography and localized enzymatic activity of bioanode GOx-ADH

Scanning electrochemical microscopy (SECM) was utilized to study the activity of immobilized enzymes. It is a powerful tool that enables mapping of local chemical re-activities at interfaces and extraction of local kinetic data of heterogeneous reactions (mediated between redox enzymes and the supporting electrode surface), or detection of reaction products at the supporting electrode [41, 42]. Therefore, using this technique, the evaluation of activity of GOx and ADH enzymes immobilized on the same electrode was carried out at the temperature of 25 °C in a clean room to locate where the enzymatic reactions occur on the surface of the electrode. An ultramicroelectrode tip-to-sample distance of 53 µm was adjusted, which was obtained via the approach of curve recording in a 5 mM solution of K3[Fe(CN)6] in a 0.1 M phosphate buffer at a potential of − 150 mV [43]. The SECM tip was positioned next to bioelectrode in the electrochemical cell by means of visual control. Subsequently, a z-approach curve was performed in a 5 mM solution of K3[Fe(CN)6] in 0.1 M phosphate buffer at 150 mV of constant potential (Fig. S2). A potential surface tilt between sample and scanning plane was compensated using a software tool which is determining a plane parallel to the sample surface by means of three consecutive z-approach curves. The z-position of the SECM tip is then adjusted during scanning in that way that the scanning plane remains parallel to the determined plane of the sample surface. Through SECM generation collection mode (GC-SECM), the ultra-micro-electrode (UME) only registers currents using the reaction products generated at the surface electrode. In the case of the enzymatic reaction of glucose oxidase, gluconolactone and hydrogen peroxide are produced. Measurements were performed by registering the H2O2 oxidation current by applying a potential of 700 mV in UME, which ensures diffusion-controlled oxidation of H2O2 [44]. Figure 5a shows the image obtained from the measurement of glucose oxidase activity in the absence (left) and presence (right) of 10 mM of glucose in a buffer solution of phosphates pH 7 by analysing a surface of 400 × 400 µm of the bi-enzymatic bioanode. It can be seen that the increase in current occurs when glucose is present, obtaining the current maximum between 3–3.6 nA, which can be seen in the red areas. The reaction does not occur on the entire surface of the electrode, only in certain specific areas.

Fig. 5
figure 5

Bi-enzymatic bioanode scanning electrochemical microscopy images. a Activity of glucose oxidase in the generator-collector SECM mode in the absence of glucose (left) and 10 mM glucose (right) in 0.1 M phosphate buffer pH = 7, Et = 0.7 V, d = 53 µm, 25 µm diameter Pt UME; and b Activity of alcohol dehydrogenase in the absence of ethanol (left) and 10 mM ethanol (right) in 0.1 M phosphate buffer pH = 7, Et = 0.4 V, d = 53 µm, 25 µm diameter Pt UME

In the case of the enzyme alcohol dehydrogenase activity immobilized together with glucose oxidase, the evaluation was performed in a different way. It has been reported that hydrophilic [Fe3(CN)6] was employed as an extracellular electron acceptor and constituted a two-redox-mediator-based system together with lipophilic mediators. The two-redox-mediators-based system response originates from the reduction of a lipophilic mediator via nicotinamide adenine dinucleotide (NAD) [44, 45], which was used to localize ethanol oxidation using the enzyme ADH. The measurements were performed by applying a potential of 400 mV in the UME using a substrate solution of 1 mM potassium ferricyanide and 0.01 M ethanol in a 0.1 M phosphate buffer solution. Likewise, the current density increased in some areas of the analysed surface (red areas) in the presence of ethanol, indicating that the fuel oxidation process was carried out. In comparison with the distribution of the enzyme glucose oxidase, the enzyme alcohol dehydrogenase covers a larger area. The electrode has zones where the two enzymes are present and have negative effects because the protein structures of the enzymes block active sites inhibiting the enzymatic activity of the enzyme that is intercepted, therefore having no available sites to react with the density of current decrease.

Performance of microfuel cell

First, the device performance was carried using only glucose as a fuel; for this purpose, two different bioanodes were evaluated, one immobilized with glucose and one immobilized with ADH, the results are shown in Fig. 6a. In both cases, a solution of 0.01 M glucose in a 0.1 M buffer phosphate solution at pH 7 was used as a fuel, and 0.3 M KOH saturated-oxygen solution was used as oxidant for the cathodic compartment. It is observed that GOx bioanode alone produced a higher performance (0.93 ± 0.07 V of open circuit voltage OCV, 8.06 ± 0.25 mA/cm2 maximum current density Jmax and 3.87 mW/cm2 ± 0.31 maximum power density Pmax compared with that obtained using a bi-enzyme electrode (OCV = 0.9 ± 0.1 V, Jmax = 7.71 ± 0.4 mA/cm2 and Pmax = 2.71 ± 0.08 mW/cm2). Similarly, the microfluidic device was evaluated using a solution of 0.01 M ethanol in a phosphate buffer solution at pH 7 and two different bioanodes (one with the enzyme ADH immobilized separately and a bi-enzymatic electrode). In this case, the performance of the cell using different anodes was similar, obtaining better results with the ADH electrode: OCV = 1.02 ± 0.11 V, Jmax = 15.63 ± 0.63 mA/cm2 and Pmax = 4.95 ± 0.45 mW/cm2 as is shown in Fig. 6b. Comparing the bi-enzymatic anode performance gives a higher power density when using ethanol than when using glucose as a fuel due to the chemical nature of the fuel because it is easier to degrade ethanol than glucose [39, 46]. The decrease in current density at the time when another enzyme is added at the electrode may be due to the increase in the protein mass, which is non-conductive or the enzyme is trapped, and its active sites are not available to react as can be observed in the scanning electrochemical microscopy studies. In the case of using a mixed solution of 0.01 M glucose and 0.01 M ethanol in a 0.1 M buffer phosphate as a fuel, the microfluidic device was evaluated using the bi-enzymatic bioanode. Figure 7a shows the obtained polarization curve (OCV = 1.05 ± 0.2 V, Jmax = 16.15 ± 1.2 mA/cm2 and Pmax = 5.07 ± 0.1 mW/cm2). The flow rate used is 60 µL/min according to different flow rates tested in the microfluidic device (Fig. S3 in supplementary information). The fuel cell performance was compared with results of other enzymatic microfluidic fuel cell already reported, where the alcohol dehydrogenase and glucose oxidase were employed as biocatalyst (Table 1). The performance obtained with the bioanodes developed in this work showed a higher power density (5071 ± 100 μW cm−2). Actually being the first microfluidic fuel cell that uses a bi-enzymatic electrode (GOx and ADH) that has the ability to oxidize ethanol and glucose at the same time in the same device as far as we know.

Fig. 6
figure 6

a Polarisation and power density curves obtained from microfluidic fuel cell using two different bioanodes: glucose oxidase-based anode separately immobilized and mixed with alcohol dehydrogenase) in the absence and presence of glucose as fuel. b Polarisation and power density curves obtained from microfluidic fuel cell using two different bioanodes: alcohol dehydrogenase immobilized separately and mixed with glucose oxidase, in the absence and presence of ethanol as fuel in 0.1 M phosphate buffer. Both at pH 7, 25 °C and 10 mV s−1.

Fig. 7
figure 7

a Polarisation and power density curve obtained from microfluidic fuel cell using a bi-enzymatic bioanode performance with a mixed solution composed of 0.01 M glucose and 0.01 M ethanol in 0.1 M phosphate buffer pH 7, 25 °C at 10 mV s−1 and 0.3 M KOH. b Chronoamperometry (at 0.02 V of potential) at the maximum current density obtained using bi-enzymatic bioanode in three different solutions as a fuel: 0.01 M glucose, 0.1 M ethanol and a mixed solution (0.01 M glucose with 0.01 ethanol) in 0.1 M phosphate buffer at pH 7 and 0.3 M KOH

Table 1 Comparison of microfluidic fuel cells performance, already reported, that employ alcohol dehydrogenase and glucose oxidase enzymes as bioanodes

A chronoamperometric measurement (Fig. 7b) was performed to determine the capability of supplying a constant current density over time using different solutions: 0.01 M glucose, 0.01 M ethanol and 0.01 M glucose with 0.01 M ethanol, all in a 0.1 M buffer phosphate solution at pH 7. An increase in current density is observed in the mixture solution compared with the other two solutions, which is attributed to both reactions, ethanol and glucose oxidation, occurring at the same time on the bi-enzymatic electrode, which indicates that both enzymes are active on the electrode surface and can operate at the same time. A high stability during the evaluation period is also observed when different solutions were used. Figure S4, in supplementary information, shows the evaluation of the bi-enzymatic electrodes in the microfluidic device during 5 days of operation using the mixture of ethanol and glucose in phosphate buffer solution, where at the end of this test, there is a loss of 11.2% of power density, indicating a good stability. Finally, the coulombic efficiency (CE) of the microfuel cell using the different fuels has been estimated by integration of the area under the current–time curve using the following Eq. 1 and 2 [47, 48]:

$$\mathrm{CE}=\frac{{C}_{\mathrm{p}}}{{C}_{\mathrm{Ti}}}\times 100\%$$
(1)
$${C}_{\mathrm{Ti}}=\frac{{Fb}_{i} {S}_{i} V}{{M}_{i}}$$
(2)

where Cp is the total coulombs calculated by integrating the current over time from Fig. 7b. CTi is estimated according to Eq. 2, as the product of Faraday’s constant F, bi is the number of moles of electrons produced per mole of the substrate, Si is the substrate concentration and V is the volume of substrate used; the product is divided by Mi, molecular weight of the substrate. The CE values are 80% when glucose is used as fuel, 26.8% in the presence of ethanol and 44.8% with glucose/ethanol mixture.

Performance of the microfuel cell using alcoholic beverage as a fuel

To show the versatility and high activity of the bioelectrode, different alcoholic beverages were used as fuel as a first attempt at real concept application, which is listed in Table 2. This table also shows the alcohol and glucose content (alcohol content was obtained from the legend presented on each container of the alcoholic beverages). Figure 8a shows the polarization and power density curves, and in Fig. 8b, it is possible to see more clearly the power density generated by each of the different alcoholic beverages. The beverage fuel that produced the highest power density was brandy (4.36 ± 0.09 mW/cm2), compared with vodka, whose alcohol content is the highest at 40%. Two types of tequilas were used, white tequila (more common) and pink tequila (Mexican tequila elaborated with infusions of jamaica to give the pink colour and caramel to give a sweet flavour). Pink tequila yielded a higher power density of 3.96 ± 0.16 mW/cm2 compared with common tequila (3.37 ± 0.073 mW/cm2), where the principal difference in both is the sugar present in Pink tequila, which is advantageous to increasing the glucose oxidation reaction by the enzyme glucose oxidase. Different commercial cocktails were also used as fuels, which contain a glucose concentration. However, two of them (pina colada and mango flavours) yielded the lowest power densities. These results coincide with the low alcohol content according to Table 2. The bioanode has better performance in the presence of alcohol than glucose due to the chemical nature of the fuel because it is easier to degrade ethanol than glucose. All alcoholic beverages were used at high acidic pH (3.1–3.7). Thus, the cell power was not very high compared with phosphate buffer solutions at pH 7. The only alcoholic drink with pH 7.2 was the cocktail of cherry-raspberry-blackberry flavour, which exhibited good performance due to its content of sugars and alcohol (2.7 ± 0.081 mW/cm2). A prospective use of the bi-enzymatic electrode incorporated in a Lab-on-a-Chip or flexible epidermal devices [49], where it can use different alcoholic beverages at different alcohol and glucose concentrations, presents alternative applications (detectors, quality and alcoholic content) for the alcoholic drinks industry.

Table 2 Alcohol and glucose content of alcoholic beverages used as fuel in the microfluidic fuel cell
Fig. 8
figure 8

a Polarisation and power density curves obtained from the microfluidic fuel cell using different alcoholic beverage as fuels and bi-enzymatic bioanode in 0.3 M KOH. b Bar graph indicating the power generated by the microfluidic cell using different alcoholic beverages

Conclusions

Using the proposed immobilization method, two enzymes of a different nature can be confined to the same electrode, glucose oxidase being FAD-dependent and alcohol dehydrogenase being NAD-dependent. Using different techniques, it was possible to demonstrate that enzymes remain active and are selective, finding the optimum parameters of pH and temperature for each one, and obtaining using a neutral pH, where the enzymes do not present an appreciable loss of catalytic activities. It was possible to observe the selectivity toward oxidation reactions of each enzyme to the corresponding substrate by scanning electrochemical microscope technique. Using the obtained images, there is no significant overlap between GOx and ADH. By evaluating the microfluidic cell using different solutions, such as glucose, ethanol and the mixture of them, it was possible to determine that there was an increase in the current density when ethanol and glucose were used at the same time. The objective of testing different alcoholic beverages as a fuel in the evaluation of microfluidic cell demonstrates the versatility of the bi-enzymatic anode, obtaining significant performance even when the pH of these drinks is acidic, showing a possible integration of the bioelectrode developed in a Lab-on-a-Chip system.