FormalPara Key Summary Points

Why carry out this study?

Fluocinolone acetonide intravitreal implant (FAc) has been recently approved as a second-line treatment for diabetic macular oedema. This corticosteroid treatment raises the issue of intraocular pressure elevation.

To report changes in intraocular pressure after an FAc intravitreal implant injection for chronic diabetic macular oedema at a European multicentre level.

What was learned from the study?

FAc intravitreal implant injection led to a predictable and manageable rise in intraocular pressure in 24.4% of patients.

Introduction

Diabetes mellitus is a common condition with an increasing prevalence, which is expected to reach 693 million patients worldwide by 2045 [1]. Diabetic macular oedema (DMO) is a microangiopathic complication of diabetes mellitus that affects 7.0% of patients with diabetes [2]. DMO is a vision-threatening condition and it is one of the major causes of visual impairment in the working population [3].

The pathogenesis of DMO results from microvascular changes, inflammation, oxidative stress and vascular dysfunction [4]. The main contributing factor is hyperglycaemia, which leads to the production of cytokines and growth factors such as vascular endothelial growth factor (VEGF). These mediators induce endothelial inflammation and breakdown of the blood–retinal barrier with the loss of pericytes and alteration of intercellular junctions. This process leads to fluid accumulation in the macular area and to increased macular thickness [5].

The management of DMO is based on several axes: stringent glycaemic and blood pressure monitoring, focal or grid laser, intravitreal anti-VEGF or corticosteroid injections, and vitreomacular surgery [6,7,8,9,10,11].

Corticosteroids have an anti-inflammatory effect in addition to their VEGF-inhibiting action [12]. Three molecules are currently available: triamcinolone, dexamethasone and fluocinolone acetonide.

The 190 µg fluocinolone acetonide intravitreal implant (FAc) (ILUVIEN®, Alimera Sciences, Alpharetta, GA, USA) has been approved as a second-line treatment for DMO in patients who have received prior corticosteroids without a clinically significant rise in intraocular pressure (IOP). It delivers an average dose of 0.2 µg/day with an initial dose of approximately 0.25 µg/day, for approximately 36 months [13, 14]

The efficacy of the FAc intravitreal implant has been established; it offers a sustained improvement in visual acuity and a reduction in central macular thickness over time, with an added value of decreasing the number of intravitreal injections compared with intravitreal anti-VEGF or corticosteroid injections [14,15,16].

The main adverse events after an FAc intravitreal implant are those related to steroids. Cataract is very common and appears on average 6–18 months after the injection [17]. IOP elevation occurs in 7–18% of patients [18, 19], and in 15–37% of cases it may require treatment with IOP-lowering medication, laser trabeculoplasty or IOP-lowering surgery [18, 20,21,22]

The purpose of this study was to report changes in IOP after an FAc intravitreal implant injection for chronic DMO at a European multicentre level.

Methods

Study Design

We conducted a retrospective, observational, European multicentre study. Data were collected from review of case records of participating centres in France, Germany, Italy and Portugal. This study was conducted in accordance with the Declaration of Helsinki. Local ethics committee approval was given and followed the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statements [23]. We extracted anonymised data from patients’ electronic medical records. The inclusion criterion was consecutive patients undergoing an FAc intravitreal implant injection between 1 September 2013 and 31 December 2020 for chronic DMO, with a minimum follow-up of 12 months after the injection. The exclusion criterion was any other indication for FAc intravitreal implant (uveitis, vein occlusion, post-cataract macular oedema).

Outcomes

The primary outcome was the mean IOP change during the 12-month follow-up after the FAc intravitreal implant. Secondary outcomes were (1) a composite endpoint defined as an increase of at least 10 mmHg after the FAc intravitreal implant, or an IOP of 25 mmHg or more at any point during follow-up, or introduction or addition of IOP-lowering treatment (IOP-lowering medication, laser trabeculoplasty or IOP-lowering surgery) [24, 25], (2) predictive factors for IOP elevation or of developing clinically significant IOP elevation.

Data Source and Measurements

We extracted data from participating centres and entered them into a normalising digital template. Datasheets are available upon reasonable request to the corresponding author. We analysed baseline data for each patient: age, sex, injection centre, lens status, DMO duration, previous DMO treatments, history of glaucoma, previous IOP-lowering treatments and baseline IOP before FAc intravitreal implant. The decision to treat the patient with an FAc intravitreal implant was at the clinicians’ discretion. If an off-label indication was retained (pre-existing glaucoma for example), patients were informed of such disposition. We collected information on the FAc intravitreal implantation date, the eye treated and whether the injection was unilateral or bilateral. After the FAc intravitreal injection, we collected IOP measurements at each follow-up visit and recorded the occurrence and date of IOP-lowering medication introduction or addition, laser trabeculoplasty or IOP-lowering surgery. We also collected data on cataract surgery events. IOP was measured via Goldmann applanation (Germany and Portugal) or air-puff tonometry (France and Italy). The same method was used at each visit in the same centre (aside from different methods between centres). It was not corrected by central corneal thickness. Every non-missing assessment collected after FAc intravitreal implant administration was assigned a follow-up visit number as follows: baseline (baseline or day 0), M1 (day 20–50), M3 (day 70–120), M6 (day 145–215), M12 (day 300–420) and at the last visit. If more than one assessment was documented within one visit period, mean IOP values were calculated.

Statistical Analysis

Continuous variables with normal distribution are presented as mean (standard deviation, SD) and non-normally distributed continuous variables are reported as median (interquartile range, IQR). Categorical variables are described as percentage of eyes or of patients. Univariate comparisons between centres were performed using Kruskal–Wallis tests for continuous data and two-tailed Fisher’s exact tests for categorical data. IOP values from M1 to M12 were considered as an outcome in a linear mixed-effect model including crossed random effects for patients and visits [26]. The IOP mean was explained by the following covariates: number of IOP-lowering medications before injection (none, one, or two or more IOP-lowering medications), intravitreal dexamethasone implant injection before the FAc intravitreal implant, age, sex and IOP at baseline (before the injection). Factors associated with a clinically significant IOP elevation at M12 were analysed using generalised logistic regression [27]. The model included the patients as a correlation component and was adjusted for the same covariates as in the linear mixed-effect analysis. The generalised estimation equations (GEE) method [28] was used to estimate odds ratios taking into account the intra-patient correlations.

A P value < 0.05 was considered statistically significant. SAS software version 9.4 (SAS Institute, Cary, NC, USA) was used for all analyses.

Results

Study Population

Overall, 221 eyes from 179 patients were included. Six eyes (five patients) were excluded due to non-DMO injection indication. Patient demographics, baseline characteristics and prior DMO and IOP treatments are presented in Table 1.

Table 1 Baseline characteristics of the study population before the fluocinolone acetonide intravitreal implant

In the overall population, the mean age was 68.7 (10.4) years with 91 men (50.8%). Most patients were pseudophakic (83.7%). The median duration of DMO was 16 months (6–50). Prior to the FAc intravitreal implantation, 194 eyes (87.8%) had received one or more intravitreal anti-VEGF injections and 195 eyes (88.2%) had intravitreal dexamethasone implant injection. Overall, 25 eyes (11.3%) had a history of glaucoma and 52 eyes (23.5%) were already under IOP-lowering treatment at baseline. One eye (0.5%) had previously undergone trabeculectomy. A total of 42 patients (23.5%) received a bilateral injection. The mean follow-up duration was 13.4 (± 12.5, range 2.4–33.5).

Detailed data by geographical origin are summarised in Table 1. The mean age in the German centre was 62.0 (10.2) years vs 70.0–73.8 years in other centres (P < 0.001). Only 43.5% of patients were pseudophakic in the German centre vs 93.6% or more in the other centres (P < 0.001). Regarding the history of DMO treatments, only 71.4% of Portuguese patients had previous intravitreal anti-VEGF injections vs 87.2% or more in the other centres (P < 0.01) and only 54.3% of the German patients had previous intravitreal dexamethasone implant vs 82.1% or more in the other centres (P < 0.001). Before the FAc intravitreal implantation, 28.2% of patients had a history of glaucoma in the German centre vs 7.8% or less in the other centres (P < 0.01). In the Portuguese centre, 42.8% of patients had previous IOP-lowering medication vs 28.2% in the German centre, 19.2% in the French centre and none in the Italian centre (P = 0.012).

IOP Changes and Management

The mean IOP in the overall study population before injection was 14.7 (3.4) mmHg. At 12 months after the FAc intravitreal implantation, it increased to 16.9 (4.7) mmHg (n = 95) (P < 0.001). The changes in IOP during follow-up are presented in Fig. 1.

Fig. 1
figure 1

Mean intraocular pressure changes over time by country. IOP intraocular pressure

Over time in the overall study population, 55 eyes (24.9%) required an addition or initiation of IOP-lowering medication, with a mean time of 7.9 (7.4) months after the FAc intravitreal implantation. The proportion of single vs dual therapy or more was 11.0% (25 eyes) and 14.0% (31 eyes), respectively. One eye (0.5%) underwent minimally invasive glaucoma surgery during follow-up and one eye (0.5%) was treated by laser trabeculoplasty. No patient underwent incisional IOP-lowering surgery. The results are presented in Table 2. The IOP distribution and time points in the present study are presented in the Supplementary Material.

Table 2 Intraocular pressure-related events and cataract surgery after the fluocinolone acetonide implant and time-to-event analyses

The incidence of clinically significant IOP elevation during the first 12 months of follow-up was 24.4% (54 eyes). In total, 25 eyes (11.3%) developed IOP of ≥ 25 mmHg and 21 (9.5%) experienced an increase in IOP of ≥ 10 mmHg compared with baseline.

Cataract Surgery

Overall, 22 eyes (10%) benefited from cataract surgery during follow-up, with a mean time to event of 15.2 (7.6) months (Table 1).

Predictive Factors for IOP Elevation After an FAc Intravitreal Implant

In the mixed-model analysis (Table 3), IOP was significantly lower in older patients (P = 0.041). It was also correlated with the baseline IOP, with an increase of 0.57 (0.06) mmHg for each additional mmHg before injection (P < 0.001). Regarding the history of previous corticosteroid injections, the IOP was significantly higher in patients who had not received an intravitreal dexamethasone implant before the FAc intravitreal implant (18.08 mmHg vs 16.41 mmHg, P = 0.009). No statistically significant difference was found for sex or number of IOP-lowering medications before the injection. The risk of developing clinically significant IOP elevation was higher in patients with one IOP-lowering medication at baseline compared to patients without treatment (odds ratio [OR] = 6.03 [2.32, 15.68], P < 0.001) (Table 4). However, no statistically significant association was found for patients with two or more medications before the injection (OR = 1.90 [0.56, 6.42], P = 0.304). Patients with a prior intravitreal dexamethasone implant injection were less likely to develop clinically significant IOP elevation after the FAc intravitreal implant (OR = 0.31 [0.11, 0.89], P = 0.027). Age or sex was not associated with the risk of clinically significant IOP elevation.

Table 3 Factors associated with intraocular pressure elevation after a fluocinolone acetonide intravitreal implant (mixed-model analysis)
Table 4 Risk factors for clinically significant intraocular pressure elevation at 12 months after a fluocinolone acetonide intravitreal implant (generalised logistic regression analysis)

Subgroup Analysis

Patients with more IOP-lowering medications before the injection were more likely to have additional IOP-lowering treatments during the 12-month follow-up: 61% (n = 17) of patients with monotherapy before injection and 33% (n = 8) of patients with dual therapy or more vs 18% (n = 30) of patients with no IOP-lowering treatment at baseline (P < 0.001) (Supplementary Material).

Discussion

The efficacy of controlling chronic DMO after FAc intravitreal implantation has been widely studied across Europe [18, 29,30,31,32,33]. Moreover, international treatment guidelines and consensus on the management of IOP in patients with DMO after FAc intravitreal implantation have been recently published [34, 35]. However, few studies other than pivotal reports have focused on its impact on IOP [20, 22]. In our study, IOP-related adverse events are reported in a European multicentre real-world design.

The safety results regarding IOP-related adverse events in this study are consistent with known side effects of corticosteroid injection [21, 36]. The mean IOP remained within the normal range (< 21 mmHg) during the first year after treatment, with a substantial proportion of cases of clinically significant IOP elevation (24.4%). IOP elevation was successfully controlled with topical treatment in most cases. Only one patient needed laser trabeculoplasty, one had a minimally invasive glaucoma surgery and no patient had incisional IOP-lowering surgery. FAc intravitreal implant was more likely to induce clinically significant IOP elevation in patients previously treated with IOP-lowering medications. Patients with more IOP-lowering medications before the FAc intravitreal implant were more likely to have additional IOP-lowering treatments during the 12-month follow-up.

These results are different from those of the FAME studies, where 18.4% of patients had an increase in IOP of ≥ 30 mmHg and 38.4% of patients received IOP-lowering treatment after injection, 1.3% had laser trabeculoplasty and 4.8% had IOP-lowering surgery [20]. Selection bias could explain these striking differences. The overall population of this study was different from that of the FAME trials, where patients with a history of elevated IOP were excluded [16]. Instead, a quarter of our patients presented with previous IOP-lowering treatment and/or history of glaucoma. Participants without a previous intravitreal dexamethasone injection were not excluded in this study, in order to reflect the different European practices. On the contrary, patients with a history of IOP elevation after a corticosteroid injection or a steroid injection during the 3 months before the FAc intravitreal implant were excluded from the FAME trials.

Other retrospective studies found similar results to this study. In the Medisoft study [18], the mean IOP remained < 21 mmHg during the 3-year follow-up. In the ILUVIEN Registry Safety Study (IRISS) [22], the mean IOP remained below 21 mmHg during the 24-month follow-up and the mean IOP increase was 1.9 mmHg. Elevated IOP of > 25 mmHg occurred in 19.1% of cases after the FAc intravitreal implant and IOP elevation was treated with IOP-lowering medication in 23.3% of the patients, with laser trabeculoplasty in 0.3% and with surgery in 2.0%. In the Retro-IDEAL study [29], the mean IOP rose from 15.8 mmHg at baseline to 18.2 mmHg at 12 months and 22.2% of patients had an increase in IOP of ≥ 10 mmHg. IOP elevation was managed with IOP-lowering medication in 27.2% of patients and 3.7% of patients needed IOP-lowering surgery.

Two phase 4 prospective studies have been conducted [19, 33]. Both excluded patients with a history of IOP-related events, but in neither case did IOP elevation require laser or surgical treatment, unlike in the FAME study.

Clinically significant IOP elevation may be more relevant than mean IOP for assessing the potential risk of steroid-induced glaucoma [37]. In this study, clinically significant IOP elevation was defined according to the SAFODEX study (IOP ≥ 25 mmHg or increase ≥ 10 mmHg compared with baseline IOP) [25]. Comparisons between different studies are hampered due to the lack of standard criteria to describe clinically significant IOP elevation with varying criteria being used [22, 29, 33]. We conducted an additional analysis of clinically significant IOP elevation using another definition for clinically significant IOP elevation (IOP increase of at least 6 mmHg to an IOP of more than 21 mmHg) and found similar results (data not shown).

Regarding predictive factors, an increased risk of elevated IOP was found for younger patients. Some studies have reported similar results with other intraocular corticosteroid treatments [25, 38]. We also found that a higher IOP value before injection was correlated with a higher IOP during follow-up. Patients with an IOP above or close to 21 mmHg before FAc intravitreal implant should be monitored more closely, as other authors have also suggested this association [39]. Moreover, the risk of elevated IOP and of clinically significant IOP elevation was lower for patients who benefited from a previous intravitreal dexamethasone injection before the FAc intravitreal implant. The pathophysiology underlying steroid-induced IOP elevation is not fully understood. Recent studies suggest that corticosteroids induce accumulation of extracellular matrix material in the trabecular meshwork, leading to an increased outflow resistance of the aqueous humour [37, 40]. These results confirm the benefit of a steroid IOP-response test before the FAc intravitreal implant, in accordance with previous studies [36, 41].

In Europe, the FAc intravitreal implant is indicated for the treatment of vision impairment associated with chronic DMO considered insufficiently responsive to available therapies. It is contraindicated in the presence of pre-existing glaucoma [42]. However, the Food and Drug Administration (FDA) guidelines are more restrictive and indicate the FAc intravitreal implant for patients with DMO who have been previously treated with corticosteroids and did not have a clinically significant rise in IOP [43]. In this study, we noted differences in several baseline characteristics between countries. France, Italy and Portugal seemed to follow the American guidelines, with a large majority of patients who had previous intravitreal dexamethasone or triamcinolone injections. On the other hand, most German patients were corticosteroid-naïve before the FAc intravitreal implant. This could be a potential selection bias that reflects local or national practices.

Still, these predictive factors can help us identify the profiles of patients who are less at risk of developing elevated IOP after an FAc intravitreal implant and thereby allow for better selection of patients eligible for this steroid treatment.

IOP was not correlated with the number of IOP-lowering medications before injection. However, a subgroup analysis based on prior IOP treatment suggests a higher risk of IOP-lowering medication addition in patients already under treatment before the injection, which is consistent with previous studies [18]. The greater addition of IOP-lowering medications may have limited the increase in IOP in these patients. Altogether, these results show the value of selecting patients eligible for FAc treatment based on their history of IOP-related events [18].

Cataract formation is a well-known side effect of steroid treatment and leads to reversible visual acuity impairment [17]. In our study, almost all phakic patients before the FAc intravitreal implant underwent cataract surgery during follow-up. We noted that a majority of patients from the German centre were phakic before the injection, whereas in other centres almost all patients were pseudophakic. Indeed, two recent studies pointed out the benefit of performing cataract surgery after the FAc intravitreal implant [30, 44]. They showed that a lasting steroid effect at the time of the cataract surgery may prevent pseudophakic cystoid macular oedema.

This study has several strengths and limitations. We followed an observational multicentre and European study design. Our data are representative of the variety of European real-world practices. The main strength of our study is also its large number of patients with IOP-focused data, compared with other smaller studies [44]. We acknowledge several limitations. First, we did not collect any anatomical or functional data to evaluate the impact of IOP elevation on the optic nerve (visual field or retinal nerve fiber layer thickness). To our knowledge, very few studies have investigated optic nerve damage in steroid-induced IOP elevation after an FAc intravitreal implant [22, 45]. In future studies, we should monitor the optic nerve head structure and function to follow the recommendations for the management of elevated IOP after an FAc intravitreal implant [39, 46]. Second, our follow-up period was short compared to the duration of the FAc effectiveness, which lasts up to 36 months. Other studies have shown a mean delay to IOP-related events of 14–18 months after injection [18]. Third, due to its retrospective design, the follow-up was not controlled, and approximately 50% of the eyes had no IOP measurements at months 3 and 12, which may have led to an inaccurate assessment of the IOP. Fourth, no specific protocol for IOP measurement was defined due to the retrospective design of the study. IOP was measured via Goldmann applanation or air-puff tonometry; this methodological limitation may have introduced significant measurement bias. Fifth, results should not be extrapolated to any other indication for FAc intravitreal implant (uveitis, central retinal vein occlusion). Sixth, mean IOP may not be the best outcome for assessing IOP-related events [47]. We presented results from European centres; hence, we acknowledge the limitations of applying these findings to other non-European populations such as patients of African descent. Finally, we did not record data on the number of previous intravitreal injections or retreatment after the FAc intravitreal implant, which could be a confounding factor affecting IOP changes.

Conclusions

In conclusion, this study that focused on IOP-related adverse events provides further evidence of the good safety profile of FAc intravitreal implants. These implants lead to a predictable and manageable rise in IOP, especially in patients with no history of IOP-related events. Younger patients and patients with high pre-FAc IOP values should be monitored closely. Moreover, previous intravitreal dexamethasone implantation seems to be a good strategy for patient selection to minimise IOP-related adverse events. The clinical relevance of these findings warrants further studies.