Abstract

Brain images acquired using the diffusion-weighted imaging (DWI) method indicate that the diagnostic efficiency of infarction improves and the noise increases as the b-value increases. In this study, we designed a fast nonlocal means (FNLM) noise reduction algorithm and evaluated its effectiveness for de-noising brain images with high b-values. The designed algorithm uses an approach that measures the similarity of local parts in an image, calculates weights based on the result, and uses the principle of reducing processing time using a simplification of the calculation. To demonstrate the effectiveness of the algorithm, we compared the qualities of the images obtained using FNLM with those obtained using previously developed algorithms with noise reduction performance and no-reference image-quality assessment parameters. The results of applying the FNLM noise reduction algorithm to DWI images obtained at high b-values indicated superior quantitative characteristics. In particular, the signal-to-noise ratio, coefficient of variation, and blind/referenceless image spatial quality evaluator (BRISQUE) results using the proposed FNLM algorithm were approximately 1.84, 1.44, and 1.21 times better than those of the noisy image, respectively. In conclusion, our results verified that the FNLM approach achieves higher noise reduction efficiency in diffusion-weighted magnetic resonance imaging.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. H.J. Jeong et al., J. Pediatrics 175, 86 (2016)

    Article  Google Scholar 

  2. S.Y. Park et al., Korean J. Rad. 20, 812 (2019)

    Article  Google Scholar 

  3. A.Y. Kim, C. Oh, H.J. Im, H.M. Baek, Exper. Neurobiol. 29, 80 (2020)

    Article  Google Scholar 

  4. S.H. Park et al., Eur. Radiol. 30, 2302 (2020)

    Article  Google Scholar 

  5. S.H. Park et al., Eur. Radiol. 27, 2554 (2017)

    Article  Google Scholar 

  6. A.A. Malayeri et al., Radiographics 31, 1773 (2011)

    Article  Google Scholar 

  7. M. Rudin, Eur. Radiol. 17, 2441 (2007)

    Article  Google Scholar 

  8. E.O. Stejskal, J.E. Tanner, J. Chem. Phys. 42, 288 (1965)

    Article  ADS  Google Scholar 

  9. F. Purroy, R. Begue, A. Quilez, J. Sanahuja, M.I. Gil, J. Neuroimaging 23, 33 (2013)

    Article  Google Scholar 

  10. P.B. Kingsley, W.G. Monahan, Mag. Reson. Med. 51, 996 (2004)

    Article  Google Scholar 

  11. J. Wang, Y. Guo, Y. Ying, Y. Liu, Q. Peng, IEEE International Conference on Image Processing, 1429 (2006)

  12. I.H. Lee et al., Optik 176, 384 (2018)

    Article  ADS  Google Scholar 

  13. S. Lee, Y. Lee, Radi. Phys. Chem. 156, 94 (2019)

    Article  ADS  Google Scholar 

  14. J.V. Manjon et al., Med. Image Anal. 12, 514 (2008)

    Article  Google Scholar 

  15. A. Buades, B. Coll, J. Morel, I.E.E.E. Comp, Vision Pattern Recog. 2, 60 (2005)

    Google Scholar 

  16. J. Rajan, B. Jeurissen, M. Verhoye, J.V. Audekerke, J. Sijbers, Phys. Med. Biol. 56, 5221 (2011)

    Article  Google Scholar 

  17. Y. Lee, Optik 172, 456 (2018)

    Article  ADS  Google Scholar 

  18. J. Hutter et al., Mag. Reson. Med. 79, 1447 (2018)

    Article  Google Scholar 

  19. M. Protter, M. Elad, H. Takeda, P. Milanfar, IEEE Trans. Image Process. 18, 36 (2009)

    Article  ADS  MathSciNet  Google Scholar 

  20. A. Buades, B. Coll, J.M. Morel, Multiscale Model. Simul. 4, 490 (2005)

    Article  MathSciNet  Google Scholar 

  21. M. Mahmoudi, G. Sapiro, IEEE Signal Process. Lett. 12, 839 (2005)

    Article  ADS  Google Scholar 

  22. J. Darbon, A. Cunha, T.F. Chan, S. Osher, G.J. Jensen, IEEE International Symposium on Biomedical Imaging: from Nano to Macro, doi: https://doi.org/10.1109/ISBI.2008.4541250 (2008)

  23. A. Mittal, R. Soundararajan, A.C. Bovik, IEEE Signal Process. Lett. 20, 209 (2013)

    Article  ADS  Google Scholar 

  24. A. Mittal, A.K. Moorthy, A.C. Bovik, IEEE Trans. Image Process. 21, 4695 (2012)

    Article  ADS  MathSciNet  Google Scholar 

  25. M.C. Maas, J.J. Futterer, T.W.J. Scheenen, Invest. Radiol. 48, 779 (2013)

    Article  Google Scholar 

  26. P. Ning et al., Sci. Rep. (2018). https://doi.org/10.1038/s41598-018-21523-6

    Article  Google Scholar 

  27. C.K. Okorie et al., West Afr. J Radiol. 22, 61 (2015)

    Article  Google Scholar 

  28. H.E. Assemlal, D. Tschumperlé, L. Brun, K. Siddiqi, Med. Image Anal. 15, 369 (2011)

    Article  Google Scholar 

  29. J.A. Young, M. Tolentino, Topics Stroke Rehab. 16, 389 (2009)

    Article  Google Scholar 

  30. J.G. Merino, S. Warach, Nat. Rev. Neurol. 6, 560 (2010)

    Article  Google Scholar 

  31. J.Y. Kim, Y. Lee, Microscopy 69, 31 (2020)

    Article  Google Scholar 

  32. Z. Zhang et al., IEEE Access 6, 11534 (2018)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Youngjin Lee.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Park, J., Kang, CK. & Lee, Y. Quantitative evaluation of the image quality using the fast nonlocal means denoising approach in diffusion-weighted magnetic resonance imaging with high b-value. J. Korean Phys. Soc. 78, 244–250 (2021). https://doi.org/10.1007/s40042-020-00028-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40042-020-00028-4

Keywords

Navigation