Abstract
Fire resistance is one of the crucial design regulations which are now mandatory in most of the design codes. Therefore, a thorough knowledge of behaviour of structures exposed to fire is required in this aspect. Columns are the most vulnerable structural member to fire as it can be exposed to fire from all sides. However, the data available for fire resistant design for columns are limited. Hence the present work is focused on the effect of cross-sectional shape of column in fire resistance design. The various cross-sections considered are Square, Ell (L), Tee (T), and Plus (‘+’) shape. Also the effect of size and shape and distribution of steel reinforcement on fire resistance of columns is studied. As the procedure for determining fire resistance is not mentioned in Indian Standard code IS 456 (2000), the simplified method (500 °C isotherm method) recommended in EN 1992-1-2:2004 (E) (Eurocode 2) is adopted. The temperature profiles for various cross-sections are developed using finite element method and these profiles are used to predict fire resistance capability of compression members. The fire resistance based on both numerical and code based methods are evaluated and compared for various types of cross-section.
Similar content being viewed by others
References
A.H. Buchanan, Structural design for fire safety (Wiley, Hoboken, 2001), pp. 225–271
V.K.R. Kodur, N.K. Raut, Design equation for predicting fire resistance of reinforced concrete columns. Struct. Concr. 10, 73 (2000)
Commission of European Committee for Standardization, Eurocode 2, Design of concrete structures- Part 1-2: General rules- Structural Fire Design (EN 1992-1-2) (Commission of European Committee for Standardization, Brussels, 2004)
L. Lixian, D.V. Reddy, K. Sobhan, Size effect on fire resistance of reinforced concrete columns and beams, in 8th Latin American and Caribbean Conference for Engineering and Technology (LACCEI’2010), Peru, (2010)
S. Bratina, B. Cas, M. Saje, I. Planinc, Numerical modelling of behaviour of reinforced concrete columns in fire and comparison with Eurocode2. Int. J. Solids Struct. 42, 5715–5733 (2005)
J.C. Dotreppe, J.M. Franssen, The use of numerical models for the fire analysis of reinforced concrete and composite structures. Eng. Anal 2(2), 67 (1985)
R.V. Khandekar, H.S. Bai, Study of fire performance of one-way reinforced concrete slabs using finite element method. The Indian Concrete Journal 85, 35 (2011)
ANSYS® Release13, Documentation for ANSYS, (2010)
IS 3809, Fire resistance test of structures, Bureau of Indian Standards, New Delhi (1979)
IS 456, Plain and reinforced concrete- Code of Practice, Fourth revision, Bureau of Indian Standards, New Delhi (2000)
IS 1642 Fire safety of buildings (general): Details of construction-Code of practice, Bureau of Indian Standards (1988)
ASCE, Structutral Fire Protection, Manual No. 78, ASCE Committee on Fire protection, Structural Division, American Society of Civil Engineers, New York (1992)
Joint ACI/TMS Committee 216, Code Requirements for Determining Fire resistance of Concrete and Masonry Construction Assemblies (ACI 216.1-07/TMS-216-07), American Concrete Institute, Farmington Hills, MI, (2007)
V.K.R. Kodur, M.M.S. Dwaikat, M.B. Dwaikat, High-temperature properties of concrete for fire resistance modelling of structures. ACI Mater. J. 105(5), 517 (2008)
T.T. Lie, J.L. Woolerton, Fire resistance of reinforced concrete columns-Test results. Internal Report No. 569, National Research Council Canada, (1988)
M. Dwaikat, V.K.R. Kodur, Flexural response of reinforced concrete beams exposed to fire. Struct. Concr. 9(1), 45–54 (2008)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Balaji, A., Muhamed Luquman, K., Nagarajan, P. et al. Behaviour of Reinforced Concrete Columns of Various Cross-Sections Subjected to Fire. J. Inst. Eng. India Ser. A 97, 221–229 (2016). https://doi.org/10.1007/s40030-016-0174-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40030-016-0174-y