Abstract
The overall objective of this study is to investigate the tensile capacity for anchor groups of cast-in-place headed anchors with high strength and deep embedment at different spacing between anchors. Experimental tensile load tests were conducted on 12 reinforced concrete specimens for the anchor groups of cast-in-place headed 42CrMo anchor bolts of 36, 48, and 60 mm in diameter with an identical embedment of 35 times the anchor diameter. The spacing between the anchors of the test specimens varied from 2 to 5 times the outside diameter of the anchor. The applied tensile loadings, the anchor displacements relative to concrete surface, the strains along the embedment length of anchor bolts, the failure loads, and the failure modes were documented comprehensively. The tensile load–displacement curves of the anchor groups approximately followed a three-phase pattern: an initial linear segment, a curvilinear transition, and a final linear sector. The interpreted tensile load-carrying capacities of elastic limit and failure threshold were obtained. The interpreted elastic limit increased as the anchor spacing increased. However, the spacing between anchors had a different effect on the interpreted failure threshold of anchor groups. All the test specimens of anchor groups failed via concrete splitting rather than concrete cone breakout, following a brittle cracking failure pattern.
Similar content being viewed by others
References
Nilforoush, R.: Numerical and experimental evaluations of load-carrying capacity of cast-in-place headed anchors and post-installed adhesive anchors. Ph.D. Dissertation, Luleå University of Technology, Luleå, Sweden, (2017)
Cannon, R.W.; Godfrey, D.A.; Moreadith, F.L.: Guide to the design of anchor bolts and other steel embedments. Concr. Int. 3(7), 28–41 (1981)
Cannon, R.W.: Straight talk about anchorage to concrete–Part I. ACI Struct. J. 92(6), 581–586 (1995)
Cook, R.A.; Collins, D.M.; Klingner, R.E.; Polyzois, D.: Load-deflection behavior of cast-in-place and retrofit concrete anchors. ACI Struct. J. 89(6), 639–649 (1992)
Fuchs, W.; Eligehausen, R.; Breen, J.E.: Concrete capacity design (CCD) approach for fastening to concrete. ACI Struct. J. 92(1), 73–94 (1995)
Gattesco, N.; Giuriani, E.: Experimental study on stud shear connectors subjected to cyclic loading. J. Constr. Steel Res. 38(1), 1–21 (1996)
Saari, W.K.; Hajjar, J.F.; Schultz, A.E.; Shield, C.K.: Behavior of shear studs in steel frames with reinforced concrete infill walls. J. Constr. Steel Res. 60, 1453–1480 (2004)
Shim, C.S.; Lee, P.G.; Yoon, T.Y.: Static behavior of large stud shear connectors. Eng. Struct. 26, 1853–1860 (2004)
Piccinin, R.; Cattaneo, S.; Biolzi, L.: Breakout capacity of headed anchors in confined concrete: experimental evidence. ACI Struct. J. 110(3), 469–479 (2013)
ACI Committee 318 Building code requirements for structural concrete (ACI 318-14) and commentary on building code requirements for structural concrete (ACI 318R-14), American Concrete Institute, Farmington Hills, MI, USA (2014)
ACI Committee 349, Code requirements for nuclear safety-related concrete structures (ACI 349-13) and commentary, American Concrete Institute, Farmington Hills, MI, USA (2013)
Martin, L.D.; Perry, C.J.: PCI Design Handbook, 6th edn. Precast/Prestressed Concrete Institute, Chicago (2004)
Eligehausen, R.; Cook, R.A.; Appl, J.: Behavior and design of adhesive bonded anchors. ACI Struct. J. 103(6), 822–831 (2006)
Lee, N.H.; Kim, K.S.; Bang, C.J.; Park, K.R.: Tensile-headed anchors with large diameter and deep embedment in concrete. ACI Struct. J. 104(4), 479–486 (2007)
ACI Committee 318 Building code requirements for structural concrete (ACI 318-02) and commentary on building code requirements for structural concrete (ACI 318R-02), American Concrete Institute, Farmington Hills, MI, USA (2002)
ACI Committee 318 Building code requirements for structural concrete (ACI 318-08) and commentary on building code requirements for structural concrete (ACI 318R-08), American Concrete Institute, Farmington Hills, MI, USA (2008)
Lee, N.H.; Park, K.R.; Suh, Y.P.: Shear behavior of headed anchors with large diameters and deep embedments. ACI Struct. J. 107(2), 146–156 (2010)
Delhomme, F.; Roure, T.; Arrietab, B.; Limam, A.: Static and cyclic pullout behavior of cast-in-place headed and bonded anchors with large embedment depths in cracked concrete. Nucl. Eng. Des. 287, 139–150 (2015)
Delhomme, F.; Roure, T.; Arrieta, B.; Limam, A.: Pullout behavior of cast-in-place headed and bonded anchors with different embedment depths. Mater. Struct. 49(5), 1843–1859 (2016)
Eligehausen, R.; Bouška, P.; Červenka, V.; Pukl, R.: Size effect of the concrete cone failure load of anchor bolts. In: Bazant, Z.P. (ed.) 1st International Conference of Fracture Mechanics of Concrete Structures (FRAMCOS 1), pp. 517–525. Taylor & Francis, New York (1992)
Mallée, R.; Fuchs, W.; Eligehausen, R.; Bergmeister, K.; Fingerloos, F.; Wörner, J.D.: Design of Fastenings for Use in Concrete: The CEN/TS 1992–4 Provisions. Ernst & Sohn, Hoboken (2013)
Nilforoush, R.; Nilsson, M.; Elfgren, L.; Ožbolt, J.; Hofmann, J.; Eligehausen, R.: Tensile capacity of anchor bolts in concrete: influence of member thickness and anchor’s head size. ACI Struct. J. 114(6), 1517–1528 (2017)
Nilforoush, R.; Nilsson, M.; Elfgren, L.; Ožbolt, J.; Hofmann, J.; Eligehausen, R.: Influence of surface reinforcement, member thickness, and cracked concrete on tensile capacity of anchor bolts. ACI Struct. J. 114(6), 1–14 (2017)
Ožbolt, J.; Eligehausen, R.; Reinhardt, H.W.: Size effect on the concrete cone pull-out load. Int. J. Fracture 95(1–4), 391–404 (1999)
Pallarés, L.; Hajjar, J.F.: Headed steel stud anchors in composite structures, Part I: shear. J. Constr. Steel Res. 60(2), 198–212 (2010)
Pallarés, L.; Hajjar, J.F.: Headed steel stud anchors in composite structures, Part II: tension and interaction. J. Constr. Steel Res. 60(2), 213–228 (2010)
Orangun, C.O.; Jirsa, J.O.; Breen, J.E.: A reevaluation of test data on development length and splices. ACI J. Proc. 74(3), 114–122 (1977)
Acknowledgements
The authors wish to acknowledge the support from the Fundamental Research Funds for Central Universities for research project Nos. 53200959614 and 2652017069 and the State Grid Corporation of China for research project No. GCB17201700149.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Qian, Zz., Lu, Xl. & Sheng, Mq. Experimental Investigation of the Tensile Capacity for Anchor Groups with Different Spacing Between Cast-in-Place Headed Anchors of High Strength and Deep Embedment. Arab J Sci Eng 44, 4745–4755 (2019). https://doi.org/10.1007/s13369-018-3548-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13369-018-3548-9