Skip to main content
Log in

Open-switch fault diagnosis and fault-tolerant control for three-phase VSI-fed induction motor drive

  • ORIGINAL ARTICLE
  • Published:
International Journal of System Assurance Engineering and Management Aims and scope Submit manuscript

Abstract

This paper proposes a new fault-diagnosis method and fault-tolerance control (FTC) strategy applied to the field-oriented control (FOC) of induction motor drives. The proposed diagnosis method for open-switch faults (OSFs) relies solely on measured current behavior. The diagnostic variables are extracted from the average absolute values of the normalized phase currents. The simulation results show that the diagnosis method can detect the OSFs in less than 36% of the fundamental phase current period without additional sensors. A total of nine types of OSFs can be diagnosed accurately and quickly. In addition, the obtained results demonstrate the method’s robustness against load-transient conditions. Compared with existing diagnosis methods, this technique relies on two diagnostic variables and an adaptive detection threshold. To improve the drive’s reliability against OSF effects, a fault-tolerant control scheme is developed based on reconfiguring the voltage source inverter (VSI) topology. In this case, the faulty VSI phase is connected to the DC-link midpoint through bidirectional power switches. Most FTC systems reported in the literature require a change in the drive’s control algorithm. Hence, this paper presents a low-cost FTC scheme without changing the FOC algorithm. Simulation results are carried out in MATLAB-Simulink to validate the effectiveness of the proposed fault diagnosis method and the FTC strategy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16

Similar content being viewed by others

References

  • Asghar F, Talha M, Kim SH (2016) Neural network based fault detection and diagnosis system for three-phase inverter in variable speed drive with induction motor. J Control Sci Eng. https://doi.org/10.1155/2016/1286318

    Article  Google Scholar 

  • Belbach A, Naït-Saïd MS, Naït-Saïd N (2022) System reconfiguration under open phase fault in a three-phase induction motor field-oriented controlled. Int J Syst Assur Eng Manag. https://doi.org/10.1007/s13198-022-01646-w

    Article  Google Scholar 

  • Bolbolnia R, Abbaszadeh K, Nasiri M (2021) Diagnosis and fault-tolerant control of six-phase wind turbine under multiple open-switch faults. Math Probl Eng. https://doi.org/10.1155/2021/9999918

    Article  Google Scholar 

  • Chen T, Pan Y, Xiong Z (2021) Fault diagnosis scheme for single and simultaneous open - circuit faults of voltage—source inverters on the basis of fault online simulation. J Power Electron 21(2):384–395. https://doi.org/10.1007/s43236-020-00209-1

    Article  Google Scholar 

  • Cherif BDE, Djerioui A, Zeghlache S, Seninete S, Tamer A (2020) Indirect vector controlled of an induction motor using H∞ current controller for IGBT open circuit fault compensation. Int Trans Electr Energy Syst. https://doi.org/10.1002/2050-7038.12540

    Article  Google Scholar 

  • El Khil SK, Jlassi I, Marques Cardoso AJ, Estima JO, Mrabet-Bellaaj N (2019) Diagnosis of open-switch and current sensor faults in PMSM drives through stator current analysis. IEEE Trans Ind Appl. https://doi.org/10.1109/TIA.2019.2930592

    Article  Google Scholar 

  • Estima JO and Cardoso AJM (2010) A novel diagnostic method for single power switch open-circuit faults in voltage-fed PWM motor drives. In: SPEEDAM 2010-international symposium on power electronics, electrical drives, automation and motion. https://doi.org/10.1109/SPEEDAM.2010.5545024

  • Estima JO, Cardoso AJM (2011) A new approach for real-time multiple open-circuit fault diagnosis in voltage-source inverters. IEEE Trans Ind Appl. https://doi.org/10.1109/TIA.2011.2168800

    Article  Google Scholar 

  • Gmati B, Jlassi I, Khojet El Khil S, Marques Cardoso AJ (2021) Open-switch fault diagnosis in voltage source inverters of PMSM drives using predictive current errors and fuzzy logic approach. IET Power Electron. https://doi.org/10.1049/pel2.12098

    Article  Google Scholar 

  • Guo H, Guo S, Xu J, Tian X (2020) Power Switch open-circuit fault diagnosis of six-phase fault tolerant permanent magnet synchronous motor system under normal and fault-tolerant operation conditions using the average current park’s vector approach. IEEE Trans Power Electron 36(3):2641–2660

    Article  Google Scholar 

  • Guo F, Yang T, Bozhko S, Wheeler P (2019) Open-switch fault diagnosis for three-phase ac-dc power converter with park’s vector method considering modulation schemes. In: 2019 IEEE 12th international symposium on diagnostics for electrical machines, power electronics and drives (SDEMPED), pp 405–411

  • Gupta YBSS, Rao SS (2020) A modified inverter topology for fault-tolerant direct torque control induction motor drive. Int J Electron. https://doi.org/10.1080/00207217.2020.1756445

    Article  Google Scholar 

  • Hoang KD, Zhu ZQ, Foster MP, Stone DA (2010) Comparative study of current vector control performance of alternate fault tolerant inverter topologies for three-phase PM brushless AC machine with one phase open-circuit fault. IET Conference Publications, (563 CP). https://doi.org/10.1049/cp.2010.0052

  • Jasim O (2009) An extended induction motor model for investigation of faulted machines and fault tolerant variable speed drives (Issue October) [Nottingham Univ.]. http://etheses.nottingham.ac.uk/1285/

  • Jian-Jian Z, Yong C, Zhang-Yong C, Anjian Z (2019) Open-switch fault diagnosis method in voltage-source inverters based on phase currents. IEEE Access 7:63619–63625. https://doi.org/10.1109/ACCESS.2019.2913164

    Article  Google Scholar 

  • Khelif MA, Bendiabdellah A, Eddine Cherif BD (2019) A combined RMS-mean value approach for an inverter open-circuit fault detection. Period Polytech Electr Eng Comput Sci. https://doi.org/10.3311/PPee.13605

    Article  Google Scholar 

  • Khwan-On S, De Lillo L, Empringham L, Wheeler PW (2010) A fault tolerant matrix converter motor drive under open phase faults. In; IET Conference Publications, (563 CP). https://doi.org/10.1049/cp.2010.0168

  • Kim JH, Sul SK (2004) A carrier-based PWM method for three-phase four-leg voltage source converters. IEEE Trans Power Electron 19(1):66–75. https://doi.org/10.1109/TPEL.2003.820559

    Article  Google Scholar 

  • Klimkowski K, Dybkowski M (2016) A fault tolerant control structure for an induction motor drive system. Automatika 57(3):638–647

    Article  Google Scholar 

  • Kwak S, Kim T, Vodyakho O (2007) Four-leg based matrix converter with fault resilient structures and controls for electric vehicle and propulsion systems. In: VPPC 2007-proceedings of the 2007 IEEE vehicle power and propulsion conference, pp 519–523. https://doi.org/10.1109/VPPC.2007.4544179

  • Liu TH, Fu JR, Lipo TA (1993) A strategy for improving reliability of field-oriented controlled induction motor drives. IEEE Trans Ind Appl 29(5):910–918. https://doi.org/10.1109/28.245714

    Article  Google Scholar 

  • Liu TH, Mubarok MS, Hendriyono D, Suwarno. (2021) Speed-loop frequency-adaptive and current-loop optimal harmonic periodic controllers for fault-tolerant SPMSM drive systems. IET Electr Power Appl. https://doi.org/10.1049/elp2.12053

    Article  Google Scholar 

  • Maamouri R, Trabelsi M, Boussak M, M’Sahli F (2018) Fault diagnosis and fault tolerant control of a three-phase VSI supplying sensorless speed controlled induction motor drive. Electr Power Compon Syst 46(19–20):2159–2173. https://doi.org/10.1080/15325008.2018.1534899

    Article  Google Scholar 

  • Manikandan R, Raghu S, Singh RR (2022) An improved open switch fault diagnosis strategy for variable speed drives. In: PESGRE 2022-IEEE international conference on power electronics, smart grid, and renewable energy. https://doi.org/10.1109/PESGRE52268.2022.9715936

  • Mendes AMS, Cardoso AJM (1999) Fault diagnosis in a rectifier-inverter system used in variable speed ac drives by the average current Park’s vector approach. In: European power electronics conference. pp 1–9

  • Nikpayam M, Ghanbari M, Esmaeli A, Jannati M (2022) Vector control methods for star-connected three-phase induction motor drives under the open-phase failure. J Operat Autom Power Eng. https://doi.org/10.22098/joape.2022.8802.1616

    Article  Google Scholar 

  • Orłowska-Kowalska T, Kowalski CT, Dybkowski M (2017) Fault-diagnosis and fault-tolerant-control in industrial processes and electrical drives. Studies in systems, decision and control. Springer International Publishing, Cham, pp 101–120. https://doi.org/10.1007/978-3-319-45735-2_5

    Chapter  Google Scholar 

  • Peuget R, Courtine S, Rognon JP (1998) Fault detection and isolation on a pwm inverter by knowledge-based model. IEEE Trans Ind Appl. https://doi.org/10.1109/28.739017

    Article  Google Scholar 

  • Rothenhagen K, Fuchs FW (2004). Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers. In: 2004 IEEE 35th annual power electronics specialists conference (IEEE Cat. No. 04CH37551). Vol 6, pp 4348–4354.

  • Rothenhagen K, Fuchs FW (2005) Performance of diagnosis methods for IGBT open circuit faults in three phase voltage source inverters for AC variable speed drives. In: 2005 European conference on power electronics and applications. https://doi.org/10.1109/epe.2005.219426

  • Salehifar M, Arashloo RS, Moreno-Equilaz JM, Sala V, Romeral L (2014) Fault detection and fault tolerant operation of a five phase pm motor drive using adaptive model identification approach. IEEE J Emerg Sel Top Power Electron 2(2):212–223. https://doi.org/10.1109/JESTPE.2013.2293518

    Article  Google Scholar 

  • Siembab K, Zawirski K (2016) Modified space vector modulation for fault tolerant control of PMSM drive. In; Proceedings-2016 IEEE international power electronics and motion control conference, PEMC 2016. https://doi.org/10.1109/EPEPEMC.2016.7752142

  • Tousizadeh M, Che HS, Selvaraj J, Rahim NA, Ooi BT (2019) Fault-tolerant field-oriented control of three-phase induction motor based on unified feedforward method. IEEE Trans Power Electron. https://doi.org/10.1109/TPEL.2018.2884759

    Article  Google Scholar 

  • Wang H, Liserre M, Blaabjerg F (2013) Toward reliable power electronics: challenges, design tools, and opportunities. IEEE Ind Electron Mag 7(2):17–26

    Article  Google Scholar 

  • Wang W, Zhang J, Cheng M, Li S (2017) Fault-tolerant control of dual three-phase permanent-magnet synchronous machine drives under open-phase faults. IEEE Trans Power Electron 32(3):2052–2063. https://doi.org/10.1109/TPEL.2016.2559498

    Article  Google Scholar 

  • Wang K, Jiang X, Wang S, Han Z (2022) Power switch open circuit fault diagnosis strategy for novel fault-tolerant electric drive system based on fuzzy logic. Energy Rep 8:914–921. https://doi.org/10.1016/j.egyr.2022.08.149

    Article  Google Scholar 

  • Wolfgang E (2007) Examples for failures in power electronics systems, presented at ECPE tutorial on reliability of power electronic systems. Nuremberg, Germany, 16(1)

  • Yan H, Xu Y, Cai F, Zhang H, Zhao W, Gerada C (2018) PWM-VSI fault diagnosis for a PMSM drive based on the fuzzy logic approach. IEEE Trans Power Electron 34(1):759–768. https://doi.org/10.1109/TPEL.2018.2814615

    Article  Google Scholar 

  • Yepes AG, Gonzalez-Prieto I, Lopez O, Duran MJ, Doval-Gandoy J (2022) A comprehensive survey on fault tolerance in multiphase AC drives, part 2: phase and switch open-circuit faults. Machines 10(3):221

    Article  Google Scholar 

  • Zahraoui Y, Fahassa C, Akherraz M, Bennassar A (2016) Sensorless vector control of induction motor using an EKF and SVPWM algorithm. In: 2016 5th international conference on multimedia computing and systems (ICMCS), pp588–593

  • Zaimen H, Rezig A, Touati S (2022) A New detection method of IGBTs open-circuit faults in an induction motor drive. Turk J Comput Math Educ (TURCOMAT) 13(2):748–760. https://doi.org/10.17762/turcomat.v13i2.12529

    Article  Google Scholar 

  • Zdiri MA, Bouzidi B, Hadj Abdallah H (2019) Performance investigation of an advanced diagnostic method for SSTPI-fed IM drives under single and multiple open IGBT faults. COMPEL-Int J Comput Math Electr Electron Eng 38(2):616–641. https://doi.org/10.1108/COMPEL-04-2018-0181

    Article  Google Scholar 

  • Zdiri MA, Bouzidi B, Abdallah HH (2020) Performance investigation of an improved diagnostic method for open igbt faults in VSI-Fed IM drives. Studies in systems, decision and control. Springer, Singapore. https://doi.org/10.1007/978-981-15-1746-4_8

    Chapter  Google Scholar 

  • Zdiri MA, Ben Ammar M, Ben Salem F, Hadj Abdallah H (2021) PWM-VSI diagnostic and reconfiguration method based on fuzzy logic approach for SSTPI-Fed im drives under IGBT OCFs. Math Probl Eng. https://doi.org/10.1155/2021/9505845

    Article  Google Scholar 

  • Zhao H, Cheng L (2018) Open-switch fault-diagnostic method for back-to-back converters of a doubly fed wind power generation system. IEEE Trans Power Electron. https://doi.org/10.1109/TPEL.2017.2705985

    Article  Google Scholar 

Download references

Funding

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hicham Zaimen.

Ethics declarations

Conflict of interest

All authors declare no conflict of interest.

Ethical approval

This research did not involve any human participants or animals.

Consent to participate

Informed consent was obtained from all participants in this study.

Consent for publication

All individual participants declare that they accept to submit this paper for publication.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zaimen, H., Rezig, A., Touati, S. et al. Open-switch fault diagnosis and fault-tolerant control for three-phase VSI-fed induction motor drive. Int J Syst Assur Eng Manag (2024). https://doi.org/10.1007/s13198-024-02317-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s13198-024-02317-8

Keywords

Navigation