Abstract
Background
The indocyanine green retention rate at 15 min (ICGR15) is a marker of the liver function and is useful for planning hepatectomy. To clarify the ICGR15 and the related clearance value (ICGK) calculated by a dye-dilution cardiac output flowmetry (DCOF), we examined the correlation and clinical significance of the ICGR15 values determined by DCOF and those determined with the conventional blood sampling (BS) procedure.
Methods
We extracted liver function parameters, including the ICGR15 modified value and ICGK, and the extent of hepatectomy from the clinical and surgical records of 63 patients with various liver diseases in whom the ICGR15 (actual value), R15m (mean), and K (clearance rate per minute) were measured by DCOF.
Results
All the patients were classified as Child-Pugh grade A. Hepatic complications were observed in 10 (16%) patients, but there was no mortality. The mean values of ICGR15 determined by BS (R15-BS) and DCOF (R15-DCOF) were 12.2 ± 8.1% and 11.2 ± 8.7%, respectively. The mean R15m determined by DCOF (R15m-DCOF) was 15.7 ± 10.2%. Significant differences were observed between R15-BS and R15-DCOF (1.1 ± 4.8%; p = 0.002) and R15m-DCOF (4.0 ± 5.9%; p < 0.001). The difference between R15-BS and R15m-DCOF was greater than that between R15-BS and R15-DCOF. Correlation between R15-BS and R15-DCOF was significant r = 0.839 (p < 0.001).
Conclusions
The ICGR15 measured by DCOF shows comparable reliability and stability to the BS method, which is useful for planning hepatectomy.
Similar content being viewed by others
References
Miyagawa S, Makuuchi M, Kawasaki S, Kakazu T. Criteria for safe hepatic resection. Am J Surg. 1995;169:589–94.
Schneider PD. Preoperative assessment of liver function. Surg Clin North Am. 2004;84:355–73.
Mullin EJ, Metcalfe MS, Maddern GJ. How much liver resection is too much? Am J Surg. 2005;190:87–97.
Seyama Y, Kokudo N. Assessment of liver function for safe hepatic resection. Hepatol Res. 2009;39:107–16.
Kubota K, Makuuchi M, Kusaka K, et al. Measurement of liver volume and hepatic functional reserve as a guide to decision-making in resectional surgery for hepatic tumors. Hepatology. 1997;26:1176–81.
Takasaki T, Kobayashi S, Suzuki S, et al. Predetermining postoperative hepatic function for hepatectomies. Int Surg. 1980;65:309–13.
Nagino M, Nimura Y, Hayakawa N, et al. Logistic regression and discriminant analyses of hepatic failure after liver resection for carcinoma of the biliary tract. World J Surg. 1993;17:250–5.
Nanashima A, Yamaguchi H, Shibasaki S, et al. Relationship between CT volumetry and functional liver volume using technetium-99m galactosyl serum albumin scintigraphy in patients undergoing preoperative portal vein embolization before major hepatectomy: a preliminary study. Dig Dis Sci. 2006;51:1190–5.
Nanashima A, Tobinaga S, Abo T, et al. Reducing the incidence of post-hepatectomy hepatic complications by preoperatively applying parameters predictive of liver function. J Hepatobiliary Pancreat Sci. 2010;17:871–8.
Busse MW, Zisowsky S, Henschen S, Panning B, Reilmann L. Determination of circulating blood volume by measurement of indocyanine green dye in hemolysate: a preliminary study. Life Sci. 1990;46:647–52.
Fox IJ, Brooker LG, Heseltine DW, Essex HE, Wood EH. A tricarbocyanine dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation. Proc Staff Meet Mayo Clin. 1957;32:478–84.
Hoya Y, Fujita T, Sakurai K. The clinical significance of ICG clearance curve measured with the finger-piece method. (Japanese with English abstract). Nihon Shokaki Geka Gakkai Zasshi. 1994;27:2099–106.
Ishigami Y, Miyoshi E, Masuzawa M, et al. Development and clinical application of ICG clearance meter. (Japanese with English abstract). Nihon Shokakibyo Gakkai Zasshi. 1989;86:2532–9.
Gams E, Hagl S, Schad H, Heimisch W, Mendler N, Sebening F. Importance of the mitral apparatus for left ventricular function: an experimental approach. Eur J Cardiothorac Surg. 1992;6:17–23.
Nanashima A, Abo T, Arai J, et al. Comprehensive predictors of portal pressure from functional liver reserve in patients who underwent hepatectomy. Indian J Surg. 2015;77 Suppl 3:923-9.
Nanashima A, Yamaguchi H, Shibasaki S, et al. Relationship between indocyanine green test and technetium-99m galactosyl serum albumin scintigraphy in patients scheduled for hepatectomy: clinical evaluation and patient outcome. Hepatol Res. 2004;28:184–90.
Sumiyoshi T, Shima Y, Okabayashi T, et al. Liver function assessment using 99mTc-GSA single-photon emission computed tomography (SPECT)/CT fusion imaging in hilar bile duct cancer: a retrospective study. Surgery. 2016;160:118–26.
Yano K, Nanashima A, Fujii Y, et al. Preoperative regional maximal removal rate of technetium-99m-galactosyl human serum albumin is correlated with liver functional parameters, but did not predict postoperative morbidity. Nucl Med Commun. 2017;38:701–7.
Fung J, Poon RT, Yu WC, et al. Use of liver stiffness measurement for liver resection surgery: correlation with indocyanine green clearance testing and post-operative outcome. PLoS One. 2013;8:e72306.
Sheng QS, Lang R, He Q, Yang YJ, Zhao DF, Chen DZ. Indocyanine green clearance test and model for end-stage liver disease score of patients with liver cirrhosis. Hepatobiliary Pancreat Dis Int. 2009;8:46–9.
Nanashima A, Sumida Y, Abo T, et al. Usefulness of measuring hepatic functional volume using technetium-99m galactosyl serum albumin scintigraphy in bile duct carcinoma: report of two cases. J Hepatobiliary Pancreat Surg. 2009;16:386–93.
Hemming AW, Scudamore CH, Shackleton CR, Pudek M, Erb SR. Indocyanine green clearance as a predictor of successful hepatic resection in cirrhotic patients. Am J Surg. 1992;163:515–8.
Okochi O, Kaneko T, Sugimoto H, Inoue S, Takeda S, Nakao A. ICG pulse spectrophotometry for perioperative liver function in hepatectomy. J Surg Res. 2002;103:109–13.
El-Desoky A, Seifalian AM, Cope M, Delpy DT, Davidson BR. Experimental study of liver dysfunction evaluated by direct indocyanine green clearance using near infrared spectroscopy. Br J Surg. 1999;86:1005–11.
Sagawa E, Okubo H, Sorin Y, et al. Use of finger-piece method for indocyanine green clearance test. Hepatol Res. 2017;47:1235–40.
Cheung TT, Chan SC, Chok KS, et al. Rapid measurement of indocyanine green retention by pulse spectrophotometry: a validation study in 70 patients with Child-Pugh A cirrhosis before hepatectomy for hepatocellular carcinoma. Hepatobiliary Pancreat Dis Int. 2012;11:267–71.
Faybik P, Krenn CG, Baker A, et al. Comparison of invasive and noninvasive measurement of plasma disappearance rate of indocyanine green in patients undergoing liver transplantation: a prospective investigator-blinded study. Liver Transpl. 2004;10:1060–4.
Hsieh CB, Chen CJ, Chen TW, et al. Accuracy of indocyanine green pulse spectrophotometry clearance test for liver function prediction in transplanted patients. World J Gastroenterol. 2004;10:2394–6.
Tokunaga M, Uto H, Oda K, et al. Influence of human T-lymphotropic virus type 1 coinfection on the development of hepatocellular carcinoma in patients with hepatitis C virus infection. J Gastroenterol. 2014;49:1567–77.
Tomimaru Y, Eguchi H, Gotoh K, et al. Platelet count is more useful for predicting posthepatectomy liver failure at surgery for hepatocellular carcinoma than indocyanine green clearance test. J Surg Oncol. 2016;113:565–9.
Oellerich M, Burdelski M, Lautz HU, Schulz M, Schmidt FW, Herrmann H. Lidocaine metabolite formation as a measure of liver function in patients with cirrhosis. Ther Drug Monit. 1990;12:219–26.
Ohkura Y, Mizuno S, Kishiwada M, et al. Benefit of technetium-99m galactosyl human serum albumin scintigraphy instead of indocyanine green test in patients scheduled for hepatectomy. Hepatol Res. 2014;44:E118–28.
Nambu M, Namihisa T. Hepatic transport of serum bilirubin, bromsulfophthalein, and indocyanine green in patients with congenital non-hemolytic hyperbilirubinemia and patients with constitutional indocyanine green excretory defect. J Gastroenterol. 1996;31:228–36.
Kwon AH, Ha-Kawa SK, Uetsuji S, Kamiyama Y, Tanaka Y. Use of technetium 99m diethylenetriaminepentaacetic acid-galactosyl human serum albumin liver scintigraphy in the evaluation of preoperative and postoperative hepatic functional reserve for hepatectomy. Surgery. 1995;117:429–34.
Hwang EH, Taki J, Shuke N, et al. Preoperative assessment of residual hepatic functional reserve using 99mTc-DTPA-galactosyl-human serum albumin dynamic SPECT. J Nucl Med. 1999;40:1644–51.
Kokudo N, Vera DR, Tada K, et al. Predictors of successful hepatic resection: prognostic usefulness of hepatic asialoglycoprotein receptor analysis. World J Surg. 2002;26:1342–7.
Yachida S, Wakabayashi H, Okano K, Suzuki Y. Prediction of posthepatectomy hepatic functional reserve by serum hyaluronate. Br J Surg. 2009;96:501–8.
Nanashima A, Yamaguchi H, Tanaka K, et al. Preoperative serum hyaluronic acid level as a good predictor of posthepatectomy complications. Surg Today. 2004;34:913–9.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
MH, KY, AN, NI, TH, and TW declare that they have no conflict of interest.
Ethics statement
The study was performed conforming to the Helsinki declaration of 1975, as revised in 2000 and 2008 concerning human and animal rights, and the authors followed the policy concerning informed consent as shown on Springer.com. The study design was approved by the Ethics Review Board of our institution, and consent to participate in the study was obtained by an opt-out procedure.
Disclaimer
The authors are solely responsible for the data and the contents of the paper. In no way, the Honorary Editor-in-Chief, Editorial Board Members, or thr printer/publishers are responsible for the results/findings and content of this article.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Hiyoshi, M., Yano, K., Nanashima, A. et al. Reliability of indocyanine green retention and clearance rates at 15 minutes calculated by dye-dilution cardiac output flowmetry in comparison to blood sampling in patients undergoing hepatic resection. Indian J Gastroenterol 38, 441–449 (2019). https://doi.org/10.1007/s12664-019-00994-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12664-019-00994-z