Introduction

Single tooth anesthesia via intra-ligamentary injections has long been used to provide localized pain control with minimal discomfort while avoiding undesirable effects like lip numbness, mainly in pediatric population with definite success. In this study, we aimed to assess the efficacy of single tooth anesthesia (STA) via intra-ligamentary injections using WAND® STA in the surgical removal of impacted third molar.

Methodology

Sixty patients were randomly divided into two groups of 30 each where Group I (study group) received local anesthesia via STA system with 4% articaine and Group II (control group) received conventional injection, that is, inferior alveolar nerve block, (IANB) with 4% articaine. Assessment of the effectiveness of the anesthesia was made by noting the onset of action, failure of anesthesia, intra-operative pain and necessity for additional injection. Additional effects such as lip numbness were also noted. Patients were evaluated for pain and discomfort after 24 h.

Results

The difference between the mean time for onset of action for STA injections and conventional block and the mean difference in the onset of action between both groups was 2.2 (± 0.25) minutes which was statistically significant (p < 0.05). Statistically significant difference in VAS score was noted only during tooth elevation with Group I reporting higher VAS score than Group II. Additional blocks were indicated in 6.7% for lingual block and 50% for long buccal nerve block in Group I and repetition of long buccal nerve block was indicated in 23.3% patients in group II. Postoperative pain and trismus was found to be higher in Group II.

Conclusion

In spite of some limits in the extent of anesthesia achieved, WAND® STA was seen to be able to achieve adequate anesthesia for surgical removal of impacted third molar and is a viable alternative, particularly in patients where blocks are contraindicated due to systemic conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

Abbreviations

STA:

Single tooth anesthesia

CCS:

Computer controlled syringes

CCLAD:

Computer controlled local anesthetic delivery system

EDA:

Electronic dental anesthesia

DPS:

Dynamic pressure sensing technology

PDL:

Periodontal ligament

AMSA:

Anterior middle superior alveolar block

TMS:

Traditional multiple supraperiosteal injections

P-ASA:

Palatal approach anterior superior alveolar nerve block

NRS:

Numeric rating scale

VRS:

Visual analogue scale

IAN:

Inferior alveolar nerve

References

  1. Subbiya A, Vikash R, Anuradha B, Mitthra S (2020) Failure of inferior alveolar nerve block and how to overcome it: a review. Eur J Mol Clin Med 7(5):2020

    Google Scholar 

  2. Kaufman E, Weinstein P, Milgrom P (1984) Difficulties in achieving local anesthesia. J Am Dent Assoc 108:205–208

    Article  CAS  PubMed  Google Scholar 

  3. Burtscher D, Dalla Torre D (2019) Intraligamentary anesthesia–a brief review of an underestimated anesthetic technique. Oral Heal Care 4:1–3

    Google Scholar 

  4. Kumar TY, John JB, Asokan S, Priya PG, Punithavathy R, Praburajan V (2015) Behavioral response and pain perception to computer controlled local anesthetic delivery system and cartridge syringe. J Indian Soc Pedod Prev Dent 33:223–228

    Article  Google Scholar 

  5. Garret-Bernardin A, Cantile T, D’Antò V, Galanakis A, Fauxpoint G, Ferrazzano GF, De Rosa S, Vallogini G, Romeo U, Galeotti A (2017) Research article pain experience and behavior management in pediatric dentistry: a comparison between traditional local anesthesia and the wand computerized delivery system. Dentist

  6. Froum SJ, Tarnow D, Caiazzo A, Hochman MN (2000) Histologic response to intraligament injections using a computerized local anesthetic delivery system. A pilot study in mini-swine. J Periodontol 71:1453–1459

    Article  CAS  PubMed  Google Scholar 

  7. Kwak EJ, Pang NS, Park W et al (2016) Computer-controlled local anesthetic delivery for painless anesthesia: a literature review. J Dental Anesth Pain Med 16(2):81–88

    Article  Google Scholar 

  8. Saxena P, Gupta SK, Newaskar V, Chandra A (2013) Advances in dental local anesthesia techniques and devices: an update. Natl J Maxillofac Surg 4(1):19–24

    Article  PubMed  PubMed Central  Google Scholar 

  9. Fischer G (1933) Local anesthesia in dentistry, 4th edn. Lea & Febiger, Philadelphia

    Google Scholar 

  10. Cassamani C (1924) Une Nouvelle Technique d’Anesthesia Intraliga–mentarire. [PhD thesis]. Paris

  11. Pashley EL, Nelson R, Pashley DH (1981) Pressures created by dental injections. J Dental Res 60:1742–1748

    Article  CAS  Google Scholar 

  12. Hochman MN (2007) Single-tooth anesthesia: pressure-sensing technology provides innovative advancement in the field of dental local anesthesia. Compend Contin Educ Dent 28:168–188

    Google Scholar 

  13. Hochman M (2001) inventor; pressure/force computer controlled drug delivery system and the like. Assigned: Milestone Scientific, Inc. US Patent 6,200,289

  14. Kämmerer PW, Adubae A, Buttchereit I, Thiem DGE, Daubländer M, Frerich B (2018) Prospective clinical study comparing intraligamentary anesthesia and inferior alveolar nerve block for extraction of posterior mandibular teeth. Clin Oral Investig 22(3):1469–1475

    Article  PubMed  Google Scholar 

  15. Ferrari M, Cagidiaco MC, Vichi A, Goracci C (2009) Efficacy of the computer-controlled injection system STA TM, the Ligmaject, and the dental syringe for intraligamentary anesthesia in restorative patients. Int Dent 11:4–12

    Google Scholar 

  16. Nicholson JW, Berry TG, Summitt JB, Yuan CH, Witten TM (2001) Pain perception and utility: a comparison of the syringe and computerized local injection techniques. General Dent 49:167–173

    CAS  Google Scholar 

  17. Ashkenazi M, Blumer S, Eli I (2005) Effectiveness of computerized delivery of intrasulcular anesthetic in primary molars. J Am Dent Assoc 136:1418–1425

    Article  PubMed  Google Scholar 

  18. Versloot J, Veerkamp JS, Hoogstraten J (2005) Computerized anesthesia delivery system vs. traditional syringe: comparing pain and pain-related behavior in children. Eur J Oral Sci 113:488–493

    Article  PubMed  Google Scholar 

  19. Campanella V, Libonati A, Nardi R, Angotti V, Gallusi G, Montemurro E et al (2018) Single tooth anesthesia versus conventional anesthesia: a cross-over study. Clin Oral Investig 22:3205–3213

    Article  PubMed  Google Scholar 

  20. Kämmerer PW, Schiegnitz E, von Haussen T, Shabazfar N, Kämmerer P, Willershausen B et al (2015) Clinical efficacy of a computerised device (STATM) and a pressure syringe (VarioJect INTRA TM) for intraligamentary anaesthesia. Eur J Dent Educ 19:16–22

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to thank the Meenakshi Academy of Higher Education and Research, Chennai, Tamil Nadu, India, for constant support to carry out our research project.

Funding

Self.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Manikandhan Ramanathan.

Ethics declarations

Conflict of interest

None.

Ethical Approval

Obtained.

Informed Consent

Obtained.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 103 kb)

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ramanathan, M., Ramanuj, S. & Ponvel, K. Efficacy and Reliability of Single Tooth Anesthesia (STA) for Surgical Removal of Impacted Wisdom Teeth: A Comparative Study. J. Maxillofac. Oral Surg. 23, 88–96 (2024). https://doi.org/10.1007/s12663-023-02017-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12663-023-02017-z

Keywords

Navigation