Abstract
Background
Adequate bone height and width is the most important parameter for success of implants. Prolonged edentulous area in mandibular posterior region is often associated with atrophy precluding the use of dental implants. Inferior alveolar nerve (IAN) lateralization is a challenging surgical procedure as it involves the exposure of the neurovascular bundle from its compact bony compartment and adequate retraction while immediate placement of implant.
Aim
Evaluation of neurosensory disturbances related to IAN lateralization for implant placement in the posterior atrophic edentulous mandible.
Materials and Methods
Ten patients above the age of 18 years with an edentulous span in mandibular posterior region showing distance from alveolar crest to IAN ≤ 8 mm (CBCT) were included in the study. The postoperative analysis of NDs was done using Semmes–Weinstein Monofilaments (SWM). Readings were made on the 1st and 7th postoperative day and every month thereafter until the neural sensations were restored.
Results
All patients reported neurosensory disturbance on post-op day 1. None of the patients responded to SWM lesser than 4.56 on first postoperative day, which indicated 100% incidence of neurosensory disturbances. The minimum time required for complete recovery was 2.0 months, and maximum was 4.0 months.
Conclusion
IAN lateralization is a useful method for managing the atrophic posterior mandible with dental implants. If done precisely with experienced personnel, it can provide a worthy option for surgical restoration of atrophic mandible with minimal temporary NDs.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Mandibular atrophy is a consequence of long-term edentulous span in the lower jaw which often leads to functional and esthetic problems. Problems include insufficient retention of the prosthesis, difficulty in speech and masticatory insufficiency [1]. Missing posterior teeth lead to loss of soft tissue support and loss of vertical dimension. This gives “aged face” look, prognathic appearance, unhappy face appearance and a reduced range of expression.
The prosthetic restoration of the partially edentulous atrophic posterior mandible has proved to be problematic. Historically, for these patients, removable partial denture was the only treatment modality available. This was most often because of lack of adequate ridge height for placing dental implants, thus denying patients a most promising dental rehabilitation option [1,2,3].
Implant supported prosthesis provide predictable long-term results and deliver a stable functional prosthesis with added advantages of esthetics, increased occlusal force, improved masticatory performance and proprioception (Fig. 1).
Adequate bone height and width is the most important parameter for success of implants. Prolonged edentulous span in mandibular posterior region is often associated with atrophy precluding the use of dental implants [2].
Inferior alveolar nerve (IAN) lateralization is a challenging surgical procedure as it involves the exposure of the neurovascular bundle from its compact bony compartment and adequate retraction while immediate placement of implant [2, 4,5,6]. This procedure requires good clinical experience, knowledge of the anatomy and ability to treat potential complications. Neurosensory disturbances (ND) include temporary or permanent anesthesia, paresthesia, dysesthesia and hyperesthesia of the nerve and are the single most important complication of the procedure [7,8,9]. The risk of fracture of the mandible is also associated due to loss of bone in the atrophied mandible. In previous studies for comparison among surgical techniques of “displacement of the foramen” and the “lateralization of the inferior alveolar nerve,” it has been found that the NDs are more in cases of displacement of the foramen (Fig. 2).
In this prospective study, we have conducted the evaluation of NDs related to IAN lateralization for implant placement in the posterior atrophic edentulous mandible. Pre- and postoperative NDs were evaluated by objective analysis using Semmes–Weinstein monofilaments (SWM).
The previous studies conducted for evaluation of NDs in IAN lateralization for implant placement were subjective in nature [10,11,12]. They used evaluation technique like questionnaires which may lack objectivity. In addition, this method does not support a scoring system of NDs for better quantification and communication. The SWM provides objective evaluation and eliminates the bias in the results and introduces an ease of quantification, hence using it enhances the communication and comparison between health professionals [3, 13, 14].
Materials and Methods
From September 2013 to December 2015, ten patients with posterior edentulous areas in the mandible underwent lateralization of the inferior alveolar neurovascular bundle and subsequent implant placement at the Department of Oral and Maxillofacial Surgery, Bharati Vidyapeeth University, Dental College and Hospital, Pune. All patients were assessed for incidence, magnitude and duration required for recovery from NDs using Semmes–Weinstein monofilaments (SWM).
In addition to routine investigations required for surgical intervention, orthopantomogram (OPG) and cone beam computerized tomography scan (CBCT) were carried out for diagnosis and treatment planning (Fig. 3).
This study was approved by the Research Academy and Ethical Committee of the Institute.
This prospective study included ten patients above the age of 18 years with an edentulous span in mandibular posterior region. It was necessary for the distance from alveolar crest to inferior alveolar nerve ≤ 8 mm (CBCT) to be included in the study. Only patients opting to place dental implant for prosthetic restoration were included. None of the patients had systemic conditions precluding minor oral surgical procedures (Fig. 4).
Semmes–Weinstein monofilaments are calibrated nylon monofilaments used to measure the patient’s ability to sense a point of pressure. A set of 5 Baseline Tactile SWM Set filaments were used (2.86, 3.61, 4.31, 4.56, and 6.65) for the evaluation. They generate a precise amount of stress over the area of application. The higher the value of the monofilament, the stiffer and more difficult it is to bend. In our study, we used monofilament to evaluate incidence, magnitude and duration of NDs (Fig. 5).
In the preoperative evaluation procedure, the patient was seated comfortably with his eyes closed to eliminate visual input. The filaments were applied perpendicular to the skin with enough force to cause the monofilament to buckle for approximately 1 s. The evaluation was carried out at predetermined 3 points based on the running course of mental nerve for obtaining standardized and comparable results. Readings were obtained for the proposed surgical side as well as the contralateral side which would serve as a control (Fig. 6).
The surgical procedure was done under local anesthesia (IAN, Lingual and Long buccal nerve blocks). The incision began from the retromolar region and was carried forward to the mesial portion of the cuspid tooth area, where a vertical relaxing incision was made. A full thickness mucoperiosteal flap was reflected. Mental nerve bundle was located and secured using a specially fabricated instrument (nerve retractor).
For the purpose of IAN lateralization, the corticotomy marking was done. The corticotomy started 3–4 mm distal to the mental foramen and extended in a distal direction, 1.5–2 cm distal to the provisional implant position. A small round bur in a straight hand piece with high torque and copious amount of sterile isotonic saline irrigation was used to prepare the corticotomy site. Only hand instruments such as small curettes and spoon excavators were used to remove the trabecular bone and gain access to the neurovascular bundle. The IAN was mobilized from its position and released from the canal using a specially fabricated instrument. After the complete release from the canal, the inferior alveolar nerve was lateralized completely and held in position till accomplishment of immediate implant placement.
Pilot drill was used to determine desired location of the implant placement using a prefabricated stent. After completion of the osteotomy with last implant drill, the implant was inserted while protecting the nerve bundle. Implant of longer length (11.5–13 mm) was inserted ensuring that the apical ends of the implants were positioned inferior to the canal. Once the implant was in its final position, the nerve was left back over the lateral aspect of the implant. The autogenous bone-graft obtained from the corticotomy was mixed with Tricalcium phosphate hydroxyapatite (TCP-HA) crystals and placed at the osteotomy site to fill the defect. Suturing was done to achieve primary closure.
The suitable medications were prescribed to the patient. Methylcobalamin was prescribed to the patient for 4 weeks, although its usefulness in nerve recovery is debatable. Patient was recalled on the first postoperative day, and radiographs were made.
The postoperative analysis of NDs was done using SWM filaments as described earlier. Readings were made on the 1st and 7th postoperative day and every month thereafter until the neural sensations were restored.
Results
A total of ten patients underwent IAN lateralization for implant placement in the mandibular posterior edentulous region under local anesthesia and sedation. All patients were evaluated for incidence, magnitude and duration of recovery from surgically induced neurosensory disturbances using Semmes–Weinstein monofilaments. All patients were available for the duration of the study.
Incidence
All patients reported neurosensory disturbance on post-op day 1. None of the patients responded to SWM lesser than 4.56 on first postoperative day, which indicates 100% incidence of neurosensory disturbance (Table 1) (n = 10–100.0%).
Magnitude
The mean value for magnitude of ND on first postoperative day was found to be 4.33 with standard deviation of ± 0.079. The minimum value on day 1 was 4.31, and maximum was 4.56. At the completion of one week, the minimum value recorded was 3.61 and maximum value recorded was 4.56.
Duration
The average time for complete recovery from NDs was. The median time to full neurosensory recovery was 3 months. The minimum time required for complete recovery was 2.0 months, and maximum was 4.0 months. The maximum follow-up required was 4 months.
Discussion
Implants help us to overcome most problems associated with traditional prosthesis. However, in patients with atrophied mandibles, sufficiently long implant fixtures cannot be placed because of potential risk of injury to the inferior alveolar nerve (IAN).
If the distance between alveolar crest and superior border of the inferior alveolar canal is less than 8 mm, it is recommended to carry out lateralization of inferior alveolar nerve to permit placement of longer implants [4].
For IAN lateralization, the IAN is exposed and it is retracted laterally during the implant placement. Following implant placement, the nerve is repositioned over the lateral aspect of the implant. In this technique, there is direct handling of the nerve. This commonly leads to temporary neurosensory disturbances in the region supplied by the nerve in the lower lip and chin area. It would be prudent to note that this study attempts to evaluate neurosensory disturbances following inferior alveolar nerve lateralization and does not deal with the success of the implants or their prosthesis [15,16,17].
In this prospective clinical study, the incidence, magnitude and duration required for recovery from neurosensory disturbances were evaluated.
The incidence, magnitude and duration of neurosensory disturbances were evaluated by the light touch test using Semmes–Weinstein monofilaments (SWM) at predetermined intervals of time. Neurosensory evaluation was carried out on 1st and 7th postoperative day and every month thereafter until up to such a point where the nerve recovery was complete.
Incidence of Neurosensory Disturbances
Hashemi [18] evaluated NDs in 82 patients at 110 sites who were treated for IAN lateralization for implant placement. His patients noted NDs in the first week, but the sites with NDs decreased to 29 (26%) at the end of the first month. This reduced to three sites (3%) at the end of the sixth month with no changes from then to the end of the year.
Morrison et al. [19] performed 26 IAN transpositions in 15 patients from 1994 to 1999. After the subjective and objective assessment of neurosensory function author stated that; all the patients reported initial change in the sensation lasting approximately for one month.
The interesting retrospective study by Kan et al. is the only one that compares both surgical techniques of “displacement of the foramen” and the “lateralization of the inferior alveolar nerve”. He analyzed 21 surgeries (64 implantations) after 10–67 months. He found out that sensory disorders occurred significantly more often in cases of displacement of the foramen (66.7%) compared to the lateralization of the nerve (33.3%) [20].
Diaz performed nineteen IAN lateralization procedures on 15 patients using piezotome. He observed that all of the patients (100%) experienced some numbness during the first week after surgery [1].
Our observations are in accordance with the observation of Hashemi et al., Hirsch, Morrison, Kan et al., Lorean et al., Daiz, Vetromilla et al. [1, 18,19,20,21,22,23] as there is 100% incidence of neurosensory disturbance on the first postoperative day. Our observations are in accordance with the observation of earlier authors who stated the 100% incidence of NDs. We would like to emphasize that in our objective evaluation, we have found that on the first postoperative day there was diminished sensation or loss of sensation in all patients as per Bell’s interpretation scale.
Magnitude of Neurosensory Disturbance
We have done an objective evaluation for neurosensory disturbance using Semmes–Weinstein monofilaments. These monofilaments consist of unique markings, individually calibrated to deliver its targeted force within a 5% standard deviation. In our review of literature, no study could be found using monofilaments as an evaluating device to assess the magnitude of the NDs.
Hashemi evaluated NDs in all 110 sites in 82 patients who were treated for IAN lateralization for implant placement. The NDs was anesthesia in 81 sites, hypoesthesia in nine sites, burning in nine sites, pain in eight sites, pinching in two sites, and tickling in one site. At the end of the first month, NDs disappeared in 81 sites (74%). NDs were hypoesthesia in 12 sites tickling in 8 sites, burning sensation in 5 sites and pain in 4 sites. At the end of the first month, nine sites of hypoesthesia reported in the first week had returned to normal. The most common type of ND was anesthesia (81 sites), and the least common type was pinching. The tickling lasted 12 months in two patients [18].
In our study, the numbers of patients with neurosensory disturbances were 10 (100%) till end of the 1st month; it was 9 patients on 2nd month, 8 patients on 3rd month and remained only 2 patients till 4th month. At the end of 4th month, they both responded to 2.83 no. monofilaments. The maximum and minimum responsive value of SWM in our study was 4.56 and 2.83, respectively.
In our study, we have evaluated neurosensory disturbances using Semmes–Weinstein monofilaments which is an objective method. These calibrated SWM generates a precise force over the application area of the skin. These numerical values make it more appropriate for communication and comparison. The Bell’s interpretation scale makes it easier to aid in its clinical application.
Recovery of Neurosensory Function
Hirsch et al. in 24 mandibular posterior segments performed evaluation of neurosensory disturbance after Inferior alveolar nerve transposition and lateralization. They found that the mean time to full resolution of sensation as judged subjectively and objectively was 4.7 weeks. The neurosensory disturbance after transposition was 5.7 and 3.8 weeks after lateralization [21].
Zuninga et al. studied 130 patients for IAN and LN (lingual nerve) injuries. They found the median duration of recovery was 11 months for IAN patients and 5.5 months for LN patients [4].
Morrison et al. [19] performed 26 IAN transpositions in 15 patients, and they found the mean time to neurosensory recovery was 16 months (range 6–60 months).
Overall, 68 IAN reposition and 11 nerve transposition procedures were performed by Lorean et al. in 57 patients (46 females and 11 males). The duration of neural disturbances after the surgery ranged from 1 to 6 months. In other cases, short-term transient nerve disturbances were reported (for 0–4 weeks). No permanent neural damage was reported [22].
Diaz et al. published a prospective cohort study of IAN lateralization by piezotome and immediate implant placement. They found that 12 patients (80%) reported no neurosensory disturbance during the first check-up 8 weeks after surgery, 14 patients (93.3% of patients/94.73% of procedures) had no neurosensory disturbance. Only one patient presented hypoesthesia 2 years after the procedure [1].
Khajehahmadi et al. compared effect of nerve lateralization and nerve transposition on intact teeth anterior to the mental foramen. They found the numbness of the lower lip at 1 week after the operation was done in both groups. After 3 months, lip sensation showed normal results in both groups, except for one patient in each group who continued to experience some form of hypoesthesia. This abnormal lip sensation persisted at the 12-month follow-up [24].
Vetromilla et al. did IAN lateralization in 125 patients and IAN transposition in 150 patients. The shortest full neurosensory recovery time was 6 months. The longest mean follow-up time was 49.1 months. At the end of follow-up, 7% of the patients still experienced neurosensory disturbances [23].
In our study, we evaluated 10 cases postoperatively on first day, after one week, then monthly up to such a point where the nerve recovery was complete. The maximum duration required for full recovery of nerve function was 4 months. The mean duration was 3 months with a standard deviation of ± 0.67 months. Our results do not corroborate with observations given by Archie Morrison et al. and Zuninga et al. [5, 19] as in their study they found the mean time to neurosensory recovery was 16 months.
The median time to full recovery was 3 months. First neurosensory recovery was noted in 2nd month. Of the 10 cases, 2 (20.0%) cases required 2-months for full recovery from ND, 6 (60.0%) cases required 3 months for full recovery and 2 (20.0%) cases required 4-months for full recovery from ND. In our study, maximum number of patients (60%) had neurosensory recovery in postoperative 3rd month.
In our study remaining 20% of cases recovered in the 4th month which required follow-up duration of 4 months. This is in agreement with the observations of Hirsh et al., Lorean, Diaz, Khajehahmadi et al., Vetromilla et al. [1, 21,22,23,24] who indicated duration of neurosensory recovery within 6 months of surgery. The restoration of neurosensory function in our study was 100%.
Conclusion
IAN lateralization is a useful method for managing the atrophic posterior mandible with dental implants. If done precisely with experienced personnel, it can provide a worthy option for surgical restoration of atrophic mandible with minimal temporary NDs. The risk of permanent damage of the IAN appears to be small. Nevertheless, the possibility of postoperative NDs associated with the procedure should be informed in detail prior to commencement of the procedure. The incidence of neurosensory disturbances may be further minimized by advances in surgical expertise and improved instrumentation.
References
Dıaz JOF, Gıas N (2013) Rehabilitation of edentulous posterior atrophic mandible inferior alveolar nerve lateralization by piezotome and immediate implant placement. Int J Oral Maxillofac Surg 42:521–526
Steinberg MJ, Kelly PD (2015) Implant-related nerve injuries. Dent Clin North Am 59:357–373
Miloro M (2005) Diagnosis and management of trigeminal nerve injuries. J Oral Maxillofac Surg 23:140–141
Zuniga JR, Meyer RA, Gregg JM, Miloro M, Davis LF (1998) The accuracy of clinical neurosensory testing for nerve injury diagnosis. J Oral Maxillofac Surg 56:2–8
Zuniga JR (2015) Sensory outcomes after reconstruction of lingual and inferior alveolar nerve discontinuities using processed nerve allograft a case series. J Oral Maxillofac Surg 73:734–744
B-TN G, Pancko FX, Kraut RA (2009) Outcomes of placing short dental implants in the posterior mandible a retrospective study of 124 cases. J Oral Maxillofac Surg 67:713–717
Kim J-H, Kim S-M, Jung H-J, Kim M-J, Lee J-H (2011) Effective end-to-end repair of inferior alveolar nerve defect by using nerve sliding technique. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 112:E28–E30
Libersa P, Savignat M, Tonnel A (2007) Neurosensory disturbances of the inferior alveolar nerve a retrospective study of complaints in a 10-year period. Am Assoc Oral Maxillofac Surg J Oral Maxillofac Surg 65:1486–1489
Lin M-H, Maub L-P, Cochran D, Shieh Y-S, Huang P-H, Huang R-Y (2014) Risk assessment of inferior alveolar nerve injury for immediate implant placement in the posterior mandible a virtual implant placement study. J Dent 42:263–270
Mosgau S, Schultze R, Reich H (1993) Assessment of inferior alveolar and lingual nerve disturbances after dentoalveolar surgery and of recovery of sensitivity. Int J Oral Maxillofac Surg 22:214–217
Paolo G, Chiscia G, Gabrieleb G, Iannettib G (2014) Conservative surgical and microsurgical techniques for the management of dental implants that impinge on the inferior alveolar nerve. Br J Oral Maxillofac Surg 52:566–568
Park Y-T, Kim S-G, Moon S-Y (2012) Indirect compressive injury to the inferior alveolar nerve caused by dental implant placement. J Oral Maxillofac Surg 70:E258–E259
Poort LJ, Van Neck JW, Van Der Wal KGH (2009) Sensory testing of inferior alveolar nerve injuries: a review of methods used in prospective studies. J Oral Maxillofac Surg 67:292–300
Al-Sabbagh M, Okeson JP, Khalaf MW, Bhavsar I (2015) A persistent pain and neurosensory disturbance after dental implant surgery pathophysiology, etiology, and diagnosis. Dent Clin North Am 59:131–142
Meyer RA, Bagheri SC (2008) Letters to editor a bioabsorbable collagen nerve cuff (NeuraGen) for repair of lingual and inferior alveolar nerve injuries a case series. J Oral Maxillofac Surg 67:2550–2551. https://doi.org/10.1016/j.joms11.002
Robinson RC, Williams CW (1986) Documentation method for inferior alveolar and lingual nerve paresthesias. Oral Surg Oral Med Oral Pathol 62:128–131
Shanti RM, Ziccardi VB (2011) Use of decellularized nerve allograft for inferior alveolar nerve reconstruction a case report. J Oral Maxillofac Surg 69:550–553
Hashemi HM (2010) Neurosensory function following mandibular nerve lateralization for placement of implants. Int J Oral Maxillofac Surg 39:452–456
Morrison A, Chiarot M, Kirby S (2002) Mental nerve function after inferior alveolar nerve transposition for placement of dental implants. J Can Dent Assoc 68(1):46–50
Quantius B (2010) Lateralization of the inferior alveolar nerve. Implants 3:18–21
Hirsch JM, Branemark PI (1995) Fixture stability and nerve function after transposition and lateralization of the inferior alveolar nerve and fixture installation. Br J Oral Maxillofac Surg 33:276–281
Lorean A, Kablan F, Mazor Z, Mijiritsky E, Russe P, Barbu H, Levin L (2013) Inferior alveolar nerve transposition and reposition for dental implant placement in edentulous or partially edentulous mandibles a multicenter retrospective study. Int J Oral Maxillofac Surg 42:656–659
Vetromilla BM, Moura LB, Sonego CL, Torriani MA, ChagasJr OL (2014) Complications associated with inferior alveolar nerve repositioning for dental implant placement a systematic review. Int J Oral Maxillofac Surg 43:1360–1366
Khajehahmadi S, Rahpeyma A, Bidar M, Jafarzadeh H (2013) Vitality of intact teeth anterior to the mental foramen after inferior alveolar nerve repositioning: nerve transpositioning versus nerve lateralization. Int J Oral Maxillofac Surg 42:1073–1078
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Rathod, M., Kshirsagar, R.A., Joshi, S. et al. Evaluation of Neurosensory Function Following Inferior Alveolar Nerve Lateralization for Implant Placement. J. Maxillofac. Oral Surg. 18, 273–279 (2019). https://doi.org/10.1007/s12663-018-1124-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12663-018-1124-1