Abstract
The double dose plateletpheresis (DDP) is considered to be a cost effective way of preparing platelets, owing to the low incidence of infectious complications and by also minimizing allogeneic donor exposure to the patients. We aimed at collecting DDP at our center and study its effect on donor hematological parameters, evaluate the product quality and the adverse donor reactions thereafter. Double Dose Platelet was collected from 160 eligible apheresis donors on Amicus cell separator (Fenwal, Inc. Three Corporate Drive Lake Zurich, IL, USA). The donor hematological parameters, product yield, adverse effects on the donors, collection efficiency (CE) and collection rate of the machine were noted. A total of 160 DDPs were collected. The total blood volume processed to achieve the yield of 6.0 × 1011 was 3673.5 ± 276.56 mL. The average yield achieved was 6.14 ± 0.26 × 1011. The average run time was 68.05 ± 6.25 min. Total ACD used was 408.33 ± 33.81 mL. We observed significant relation of pre-donation donor platelet count and platelet yield (p < 0.001). The CE was 78.09 ± 5.15%. There was a significant drop in the post DDP platelet count (p < 0.01) causing no adverse effect. Fourteen donors (8.75%) experienced mild citrate related adverse events. DDP does not lead to major adverse effects and post DDP hematological parameters are also within the acceptable range. It also helps to maintain apheresis platelet inventory, reduce donor exposure, reduce donor requirement and reduce the cost of the product.
Similar content being viewed by others
References
Fontana S, Kellerb P, Taleghanib MB (2011) Platelet recruitment during multiple donor plateletapheresis differs between cell separators. Transfus Med Hemother 38:195–198
Grifols-Lucas JA (1952) Use of plasmapheresis in blood donors. BMJ 1:854
Freireich EJ, Judson G, Levin RH (1965) Separation and collection of leukocytes. Cancer Res 25:1516–1520
Snyder EL, Elfath MD, Taylor H, Taylor H, Rugg N, Greenwalt TJ, Baril L, Whitley P, Brantigan B, Story K (2003) Collection of two units of leukoreduced RBCs from a single donation with a portable multiple-component collection system. Transfusion 43:1695–1705
Wollersheim J, Dautzenberg M, van de Griendt A, Sybesma B (2006) Donor selection criteria to maximize double platelet components (DPP) by platelet apheresis. Transfus Apher Sci 34:179–186
Das SS, Chaudhary R, Verma SK, Ojha S, Khetan D (2009) Pre- and post- donation haematological values in healthy donors undergoing plateletpheresis with five different systems. Blood Transfus 7(3):188–192
Zingsem J (2010) Multicomponenet apheresis. ISBT Sci Ser 5:83–87
Picker SM, Radojska SM, Gathof BS (2006) Evaluation of concurrent collection of in-line filtered platelets and packed red blood cells by multicomponent apheresis with three last-generation apparatuses. Vox Sang 91:47–55
Julmy F, Ammann RA, Mansouri Taleghani B, Fontana S, Hirt A, Leibundgut K (2008) Effects of high-yield thrombocytapheresis on the quality of platelet components. Transfusion 48:442–450
Richa E, Krueger P, Burgstaler EA, Bryant SC, Winters JL (2008) The effect of double- and triple-apheresis platelet component donation on apheresis donor platelet and white blood cell counts. Transfusion 48:1325–1332
Gurak S, Arslan O (2007) Efficacy of Fenwal Amicus blood cell separator in double dose platelet collection. Transfus Apher Sci 36:69–72
Food and Drug Administration (2007) Guidance for industry and FDA review staff: collection of platelets by automated methods. U.S. Department of Health and Human Services, Washington DC, pp 1–3
Malik V (2001) Drugs & cosmetics act, 13th edn. Eastern Book Company, Lucknow
Das SS, Chaudhary R, Verma SK, Ojha S, Khetan D (2009) Pre and post donation hematological values in healthy donors undergoing plateletpheresis with five different systems. Blood Transfus 7:188–192
Price TH (2003) Provision of single-donor platelet transfusions: patient and producer perspectives. In: McLeod BC, Price TH, Weinstein R (eds) Apheresis: principles and practice, 2nd edn. AABB Press, Bethesda, pp 185–197
Vassallo R, Murphy S (2003) Platelet function, kinetics and metabolism: impact on quality assessment, storage and clinical use. In: McLeod BC, Price TH, Weinstein R (eds) Apheresis: principles and practice, 2nd edn. AABB Press, Bethesda, pp 161–183
Ness P, Braine H, King K, Barrasso C, Kickler T, Fuller A et al (2001) Single donor platelets reduce the risk of septic platelet transfusion reactions. Transfusion 41:857–861
Ness PM, Campbell-Lee SA (2001) Single donor versus pooled random donor platelet concentrates. Curr Opin Hematol 8:392–396
Singh RP, Marwaha N, Malhotra P, Dash S (2009) Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC) and apheresis-PC methods. Asian J Transfus Sci 3(2):86–94
Stainsby D, Jones H, Asher D, Atterbury C, Boncinelli A, Brant L, Chapman CE, Davison K, Gerrard R, Gray A, Knowles S, Love EM, Milkins C, McClelland DB, Norfolk DR, Soldan K, Taylor C, Revill J, Williamson LM, Cohen H (2006) Serious hazards of transfusion: a decade of hemovigilance in the UK. Transfus Med Rev 20:273–282
Kleinmann S, Grossman B, Kopko P (2010) A national survey of transfusion-related acute lung injury risk reduction policies for platelets and plasma in the United States. Transfusion 50:1312–1321
Glicher RO, Smith JW (eds) (2009) Apheresis: principles and technologies of hemapheresis. In: Simon LT, Snyder EL, Solheim BG, Stowell CP, Strauss RG, Petrides M (eds) Rossi‘s principle of transfusion medicine, 4th edn. Blackwell Publishing Ltd, pp 617–628
Chaudhary R, Das SS, Khetan D, Ojha S, Verma S (2010) Donor safety issue in high-dose platelet collection using the latest apheresis system. Transfus Altern Transfus Med 11:1–7
Jaipian J, Chuansumrit A, Chongkolwatana V, Kunakorn M, Kitpoka P (2013) Collection efficacies of double dose platelet by blood cell separators. J Hematol Transfus Med 23:121–128
Fontana S, Mordasini L, Keller P, Taleghani BM (2006) Prospective, paired crossover comparison of multiple, single-needle plateletpheresis procedures with the Amicus and Trima Accel cell separators. Transfusion 46:2004–2010
Keklik M, Eser B, Kaynar L, Solmaz M, Ozturk A, Yay M, Birekul A, Oztekin M, Sivgin S, Cetin M, Unal A (2014) Comparison of double dose plateletpheresis on the Fenwal Amicus, Fresenius COM.TEC and Trima Accel cell separators. Transfus Apher Sci 51:193–196
Flesch BK, Adamzik I, Steppat D, Miller J, Carstensen L, Schapke M, Davey J (2010) Paired crossover study of tw o plateletpheresis systems concerning platelet component quality and donor comfort. Transfusion 50:894–901
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of Interest
The authors have no conflict of interest.
Ethical Approval
All procedures performed in this study were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Rights and permissions
About this article
Cite this article
Makroo, R.N., Fadadu, D., Agrawal, S. et al. Double Dose Plateletpheresis: A Savior to Shrinking Donor Pool and Platelet Inventory Management. Indian J Hematol Blood Transfus 34, 691–696 (2018). https://doi.org/10.1007/s12288-018-0920-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12288-018-0920-6