Skip to main content
Log in

Impact of indoor-outdoor temperature differences on dispersion of gaseous pollutant and particles in idealized street canyons with and without viaduct settings

  • Research Article
  • Indoor/Outdoor Airflow and Air Quality
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Computational fluid dynamics simulations were performed to investigate flow and pollutant dispersion in a 2D street canyon of aspect ratio H/W = 1. Different from other works, the combination of the presence of viaduct and indoor-outdoor temperature differences ΔT is investigated for different approaching wind velocities. For larger wind velocity (2 m/s, Froude number Fr~3.06–12.24) the typical clockwise vortex leads to higher concentrations of both gas and small particles at the leeward side of the street and in the leeward-side rooms; the vortex is enhanced under large ΔT (20 K) improving the dispersion of pollutants. For smaller velocity (0.5 m/s, Fr~0.19–0.77) the appearance of an anti-clockwise vortex leads to a strong accumulation of gas and particles at the windward side and in the windward-side rooms under low ΔT (5 K); increasing the ΔT raises the dispersion of pollutants with consequent lower concentrations in the rooms (up to an average of 67% with respect to the isothermal case for gaseous pollutants), but accumulation close to the ground level at both windward-side and leeward-side rooms. In the presence of viaduct, together with the main vortex above the viaduct which causes concentrations increasing from low-level to high-level leeward-side rooms, two vortices are generated below it. Still ΔT = 20 K improves the dispersion of pollutants, leading up to a maximum of about 30% lower gaseous concentrations in the rooms. In general, lower concentrations of gas and particles are found for larger velocity, indicating that the mechanical turbulence dominates over the buoyancy effects, which become crucial for smaller velocity. This study confirms previous findings that viaducts may improve pollutant dispersion under large velocity if only one viaduct-level pollutant source exists and indoor-outdoor ΔT conditions can mitigate street air pollution.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ai ZT, Mak C M (2014). A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions. Atmospheric Environment, 88: 1–13.

    Article  Google Scholar 

  • Allegrini J, Dorer V, Carmeliet J (2013). Wind tunnel measurements of buoyant flows in street canyons. Building and Environment, 59: 315–326.

    Article  Google Scholar 

  • Allegrini J, Dorer V, Carmeliet J (2014). Buoyant flows in street canyons: Validation of CFD simulations with wind tunnel measurements. Building and Environment, 72: 63–74.

    Article  Google Scholar 

  • Bo M, Salizzoni P. Clerico M, Buccolieri R (2017). Assessment of indoor-outdoor particulate matter air pollution: A review. Atmosphere, 8: 136.

    Article  Google Scholar 

  • Buccolieri R, Salim SM, Leo LS, Di Sabatino S, Chan A, Ielpo P, de Gennaro G, Gromke C (2011). Analysis of local scale tree-atmosphere interaction on pollutant concentration in idealized street canyons and application to a real urban junction. Atmospheric Environment 45: 1702–1713.

    Article  Google Scholar 

  • Buccolieri R, Salizzoni P, Soulhac L, Garbero V, Di Sabatino S (2015). The breathability of compact cities. Urban Climate, 13: 73–93.

    Article  Google Scholar 

  • Chang CH, Meroney RN (2003). Concentration and flow distributions in urban street canyons: wind tunnel and computational data. Journal of Wind Engineering and Industrial Aerodynamics, 91: 1141–1154.

    Article  Google Scholar 

  • Cheng WC, Liu CH, Leung DYC (2008). Computational formulation for the evaluation of street canyon ventilation and pollutant removal performance. Atmospheric Environment, 42: 9041–9051.

    Article  Google Scholar 

  • Chen C, Zhao B, Zhou W, Jiang X, Tan Z (2012). A methodology for predicting particle penetration factor through cracks of windows and doors for actual engineering application. Building and Environment, 47: 339–348.

    Article  Google Scholar 

  • Cui PY, Li Z, Tao WQ (2016). Wind-tunnel measurements for thermal effects on the air flow and pollutant dispersion through different scale urban areas. Building and Environment, 97: 137–151.

    Article  Google Scholar 

  • Di Sabatino S, Buccolieri R, Salizzoni P (2013). Recent advancements in numerical modelling of flow and dispersion in urban areas: a short review. International Journal of Environment and Pollution, 52: 172–191.

    Article  Google Scholar 

  • Fluent (2006). Fluent V6.3. User’s Manual. https://doi.org/fluent.com.

    Google Scholar 

  • Gao NP, Niu JL, Perino M, Heiselberg P (2008). The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation. Building and Environment, 43: 1805–1817.

    Article  Google Scholar 

  • Gao NP, Niu JL, Perino M, Heiselberg P (2009). The airborne transmission of infection between flats in high-rise residential buildings: Particle simulation. Building and Environment, 44: 402–410.

    Article  Google Scholar 

  • Gromke C, Ruck B (2007). Influence of trees on the dispersion of pollutants in an urban street canyon-Experimental investigation of the flow and concentration field. Atmospheric Environment, 41: 3287–3302.

    Article  Google Scholar 

  • Gromke C, Blocken B (2015). Influence of avenue-trees on air quality at the urban neighborhood scale. Part I: Quality assurance studies and turbulent Schmidt number analysis for RANS CFD simulations. Environmental Pollution, 196: 214–223.

    Article  Google Scholar 

  • Habilomatis G, Chaloulakou A (2015). A CFD modeling study in an urban street canyon for ultrafine particles and population exposure: The intake fraction approach. Science of the Total Environment, 530–531: 227–232.

    Article  Google Scholar 

  • Hang J, Wang Q, Chen X, Sandberg M, Zhu W, Buccolieri R, Di Sabatino S (2015). City breathability in medium density urban-like geometries evaluated through the pollutant transport rate and the net escape velocity. Building and Environment, 94: 166–182.

    Article  Google Scholar 

  • Hang J, Lin M, Wong DC, Wang X, Wang B, Buccolieri R (2016). On the influence of viaduct and ground heating on pollutant dispersion in 2D street canyons and toward single-sided ventilated buildings. Atmospheric Pollution Research, 7: 817–832.

    Article  Google Scholar 

  • Hang J, Luo Z, Wang X, He L, Wang B, Zhu W (2017). The influence of street layouts and viaduct settings on daily CO exposure and intake fraction in idealized urban canyons. Environmental Pollution, 220: 72–86.

    Article  Google Scholar 

  • Hang J, Chen L, Lin Y, Buccolieri R, Lin B (2018). The impact of semi-open settings on ventilation in idealized building arrays. Urban Climate, 25: 196–217.

    Article  Google Scholar 

  • He L, Hang J, Wang X, Lin B, Li X, Lan G (2017). Numerical investigations of flow and passive pollutant exposure in high-rise deep street canyons with various street aspect ratios and viaduct settings. Science of the Total Environment, 584–585: 189–206.

    Article  Google Scholar 

  • Ji W, Zhao B (2015). Contribution of outdoor-originating particles, indoor-emitted particles and indoor secondary organic aerosol (SOA) to residential indoor PM2.5 concentration: A model-based estimation. Building and Environment, 90: 196–205.

    Article  Google Scholar 

  • Jiang Y, Alexander D, Jenkins H, Arthur R, Chen QY (2003). Natural ventilation in buildings: measurement in a wind tunnel and numerical simulation with large-eddy simulation. Journal of Wind Engineering and Industrial Aerodynamics, 91. 331–353.

    Article  Google Scholar 

  • Jin R, Hang J, Liu S, Wei J, Liu Y, Xie J, Sandberg M. (2016). Numerical investigation of wind-driven natural ventilation performance in a multi-storey hospital by coupling indoor and outdoor airflow. Indoor and Built Environment, 25: 1226–1247.

    Article  Google Scholar 

  • Kobayashi T, Sandberg M, Kotani H, Claesson L. (2010). Experimental investigation and CFD analysis of cross-ventilated flow through single room detached house model. Building and Environment, 45: 2723–2734.

    Article  Google Scholar 

  • Kumar P, Ketzel M, Vardoulakis S, Pirjola L, Britter R (2011). Dynamics and dispersion modelling of nanoparticles from road traffic in the urban atmospheric environment-A review. Journal of Aerosol Science, 42: 580–603.

    Article  Google Scholar 

  • Lin L, Hang J, Wang X, Wang X, Fan S, Fan Q, Liu Y (2016). Integrated effects of street layouts and wall heating on vehicular pollutant dispersion and their reentry into downstream canyons. Aerosol and Air Quality Research, 16: 3142–3163s.

    Article  Google Scholar 

  • Liu J, Luo Z, Zhao J, Shui T (2012). Ventilation in a street canyon under diurnal heating conditions. International Journal of Ventilation, 11: 141–154.

    Article  Google Scholar 

  • Luo Z, Li Y, Nazaroff WW (2010). Intake fraction of nonreactive motor vehicle exhaust in Hong Kong. Atmospheric Environment, 44: 1913–1918.

    Article  Google Scholar 

  • Meroney RN, Pavageau M, Rafailidis S, Schatzmann M (1996). Study of line source characteristics for 2-D physical modelling of pollutant dispersion in street canyons. Journal of Wind Engineering and Industrial Aerodynamics, 62: 37–56.

    Article  Google Scholar 

  • Nazarian N, Kleissl J (2016). Realistic solar heating in urban areas: Air exchange and street-canyon ventilation. Building and Environment, 95: 75–93.

    Article  Google Scholar 

  • Ng WY, Chau CK (2014). A modelling investigation of the impact of street and building configurations on personal air pollutant exposure in isolated deep urban canyons. Science of the Total Environment, 468–469: 429–448.

    Article  Google Scholar 

  • Park SJ, Kim JJ, Kim MJ, Park RJ, Cheong HB (2015). Characteristics of flow and reactive pollutant dispersion in urban street canyons. Atmospheric Environment, 108: 20–31.

    Article  Google Scholar 

  • Ramponi R, Blocken B (2012). CFD simulation of cross-ventilation for a generic isolated building: Impact of computational parameters. Building and Environment, 53: 34–48.

    Article  Google Scholar 

  • Santiago JL, Krayenhoff ES, Martilli A (2014). Flow simulations for simplified urban configurations with microscale distributions of surface thermal forcing. Urban Climate, 9: 115–133.

    Article  Google Scholar 

  • Solazzo E, Vardoulakis S, Cai X (2011). A novel methodology for interpreting air quality measurements from urban streets using CFD modelling. Atmospheric Environment, 45: 5230–5239.

    Article  Google Scholar 

  • Stavridou AD, Prinos PE (2013). Natural ventilation of buildings due to buoyancy assisted by wind: Investigating cross ventilation with computational and laboratory simulation. Building and Environment, 66: 104–119.

    Article  Google Scholar 

  • Tan Z, Dong J, Xiao Y, Tu J (2015). A numerical study of diurnally varying surface temperature on flow patterns and pollutant dispersion in street canyons. Atmospheric Environment, 104: 217–227.

    Article  Google Scholar 

  • van Hooff T, Blocken B (2013). CFD evaluation of natural ventilation of indoor environments by the concentration decay method: CO2 gas dispersion from a semi-enclosed stadium. Building and Environment, 61: 1–17.

    Article  Google Scholar 

  • Wang X, Li Y (2016). Predicting urban heat island circulation using CFD. Building and Environment, 99: 82–97.

    Article  Google Scholar 

  • Yakhot V, Orszag SA (1986). Renormalization group analysis of turbulence. I. Basic theory. Journal of Scientific Computing, 1: 3–51.

    Article  MathSciNet  MATH  Google Scholar 

  • Yazid AWM, Sidik NAC, Salim SM, Saqr KM (2014). A review on the flow structure and pollutant dispersion in urban street canyons for urban planning strategies. Simulation, 90: 892–916.

    Article  Google Scholar 

  • Zhang C, Wen M, Zeng J, Zhang G, Fang H, Li Y (2012). Modeling the impact of the viaduct on particles dispersion from vehicle exhaust in street canyons. Science China Technological Sciences, 55: 48–55.

    Article  Google Scholar 

  • Zhong J, Cai X-M, Bloss WJ (2015). Coupling dynamics and chemistry in the air pollution modelling of street canyons: A review. Environmental Pollution, 214: 690–704.

    Article  Google Scholar 

Download references

Acknowledgements

This research was supported by the National Key R&D Program of China (2016YFC0202206 and 2016YFC0202205); the National Natural Science Foundation of China (No. 51478486) and National Natural Science Foundation—Outstanding Youth Foundation (No. 41622502 ) as well as Science and Technology Program of Guangzhou, China (No. 201607010066 and No. 2014B020216003).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Riccardo Buccolieri or Baomin Wang.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hang, J., Buccolieri, R., Yang, X. et al. Impact of indoor-outdoor temperature differences on dispersion of gaseous pollutant and particles in idealized street canyons with and without viaduct settings. Build. Simul. 12, 285–297 (2019). https://doi.org/10.1007/s12273-018-0476-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-018-0476-2

Keywords

Navigation