Skip to main content
Log in

Examining the applicability of empirical models using short-term VOC emissions data from building materials to predict long-term emissions

  • Research Article
  • Indoor/Outdoor Airflow and Air Quality
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Chamber testing is a common method to evaluate volatile organic compound (VOC) emissions from building materials. Empirical models based on short-term testing (typically less than 28 days) are frequently used to estimate long-term emissions (up to years). However, the applicability of the empirical models for long-term prediction remains unclear in practice. Four empirical models, i.e., two constant models with and without a prerequisite (M1 and M2), a power-law model (M3), and an exponential model (M4), were used to test the applicability of predicting year-long emissions using emission data that were less than one month. The diffusion-based mass-transfer model was used to generate reference emission data with random variations involved to represent measurement errors, etc. For M1 and M2, the discrepancy ratios between the constant emissions and the characteristic average emissions are quantified. For M3 and M4, an additional measure, i.e., normalized mean square error (NMSE), was adopted to statistically study the applicability of using empirical models to predict long-term emissions. The results shown that, first, the NMSE values indicate that M3 prefers slow emissions and generally performs better than M4. However, M4 performs better for predicting year-long emissions for cases with characteristic emission time of one year. Second, both M3 and M4 predict the average life-long emissions reasonably well for most scenarios. Third, while the effects of test duration are less significant for M3 than M4, the early-stage sampling points are more important for better long-term predictions. Additionally, experimental data by National Research Council Canada (NRC) were used to validate the applicability of the empirical models in year-long emission predictions, with the results similar to those from the simulated data. This paper can be used as a reference to select appropriate empirical model(s), as well as the testing duration, to simulate long-term VOC emissions from building materials using short-term testing data.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • AgBB (2012). Health-related Evaluation Procedure for Volatile Organic Compounds Emissions (VOC and SVOC) from Building Products. Germany, Ausschuss zur gesundheitlichen Bewertung von Bauprodukten.

    Google Scholar 

  • ASTM (2010). D5116-10 Standard Guide for Small-scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials Products. West Conshohocken, PA, USA: ASTM International.

    Google Scholar 

  • ASTM (2013). D6670-13 Standard Practice for Full-scale Chamber Determination of Volatile Organic Emissions from Indoor Materials Products. West Conshohocken, PA, USA: ASTM International.

    Google Scholar 

  • ASTM (2014). D5157-97(R2014) Standard Guide for Statistical Evaluation of Indoor Air Quality Models. West Conshohocken, PA, USA: ASTM International.

    Google Scholar 

  • BIFMA (2011). ANSI/BIFMA M7.1 Standard Test Method for Determining VOC Emissions from Office Furniture Systems, Components and Seating. Grand Rapids, MI, USA: BIFMA International.

    Google Scholar 

  • Brown SK, Sim MR, Abramson MJ, Gray CN (1994). Concentrations of volatile organic compounds in indoor air—A review. Indoor Air, 4: 123–134.

    Article  Google Scholar 

  • CDPH (2010). Standard Method for the Testing and Evaluation of VOC Emissions from Indoor Sources Using Environmental Chambers Version 1.1. California, USA: California Department of Public Health.

    Google Scholar 

  • Chaudhary A, Hellweg S (2014). Including indoor offgassed emissions in the life cycle inventories of wood products. Environmental Science & Technology, 48: 14607–14614.

    Article  Google Scholar 

  • Cox SS, Little JC, Hodgson AT (2001a). Measuring concentrations of volatile organic compounds in vinyl flooring. Journal of the Air & Waste Management Association, 51: 1195–1201.

    Article  Google Scholar 

  • Cox SS, Zhao D, Little JC (2001b). Measuring partition and diffusion coefficients for volatile organic compounds in vinyl flooring. Atmospheric Environment, 35: 3823–3830.

    Article  Google Scholar 

  • ECA (2013). Report No. 29. Harmonisation Framework for Health Based Evaluation of Indoor Emissions from Construction Products in the European Union Using the EU-LCI Concept. EUR 26168/EN. Luxembourg: Publications Office of the European Union.

    Google Scholar 

  • Guo Z (2002a). Review of indoor emission source models. Part 1. Overview. Environmental Pollution, 120: 533–549.

    Article  Google Scholar 

  • Guo Z (2002b). Review of indoor emission source models. Part 2. Parameter estimation. Environmental Pollution, 120: 551–564.

    Article  Google Scholar 

  • Haghighat F, Lee CS, Ghaly WS (2002). Measurement of diffusion coefficients of VOCs for building materials: review and development of a calculation procedure. Indoor Air, 12: 81–91.

    Article  Google Scholar 

  • Han K, Zhang JS, Wargocki P, Knudsen HN, Varshney PK, Guo B (2012). Model-based approach to account for the variation of primary VOC emissions over time in the identification of indoor VOC sources. Building and Environment, 57: 403–416.

    Article  Google Scholar 

  • Huang S, Xiong J, Zhang Y (2013). A rapid and accurate method, ventilated chamber C-history method, of measuring the emission characteristic parameters of formaldehyde/VOCs in building materials. Journal of Hazardous Materials, 261: 542–549.

    Article  Google Scholar 

  • Li F, Niu J (2005). Simultaneous estimation of VOCs diffusion and partition coefficients in building materials via inverse analysis. Building and Environment, 40: 1366–1374.

    Article  Google Scholar 

  • Li M (2013). Robust nonfitting way to determine mass diffusivity and initial concentration for VOCs in building materials with accuracy estimation. Environmental Science & Technology, 47: 9086–9092.

    Article  Google Scholar 

  • Liang W, Yang C, Yang X (2014). Long-term concentrations of volatile organic compounds in a new apartment in Beijing, China. Building and Environment, 82: 693–701.

    Article  Google Scholar 

  • Liang W, Yang S, Yang X (2015). Long-term formaldehyde emissions from medium-density fiberboard in a full-scale experimental room: Emission characteristics and the effects of temperature and humidity. Environmental Science & Technology, 49: 10349–10356.

    Article  Google Scholar 

  • Little JC, Hodgson AT, Gadgil AJ (1994). Modeling emissions of volatile organic compounds from new carpets. Atmospheric Environment, 28: 227–234.

    Article  Google Scholar 

  • Liu W, Zhang Y, Yao Y, Li J (2012). Indoor decorating and refurbishing materials and furniture volatile organic compounds emission labeling systems: A review. Chinese Science Bulletin, 57: 2533–2543.

    Article  Google Scholar 

  • Liu Z, Ye W, Little JC (2013). Predicting emissions of volatile and semivolatile organic compounds from building materials: A review. Building and Environment, 64: 7–25.

    Article  Google Scholar 

  • Liu X, Mason MA, Guo Z, Krebs KA, Roache NF (2015). Source emission and model evaluation of formaldehyde from composite and solid wood furniture in a full-scale chamber. Atmospheric Environment, 122: 561–568.

    Article  Google Scholar 

  • Park HS, Ji C, Hong T (2016). Methodology for assessing human health impacts due to pollutants emitted from building materials. Building and Environment, 95: 133–144.

    Article  Google Scholar 

  • Qian K, Zhang Y, Little JC, Wang X (2007). Dimensionless correlations to predict VOC emissions from dry building materials. Atmospheric Environment, 41: 352–359.

    Article  Google Scholar 

  • Weschler CJ (2009). Changes in indoor pollutants since the 1950s. Atmospheric Environment, 43: 153–169.

    Article  Google Scholar 

  • Won D, Magee R, Yang W, Lusztyk E, Nong G, Shaw C (2005). A material emission database for 90 target VOCs. In: Proceedings of Indoor Air 2005, Beijing, China.

    Google Scholar 

  • Won D, Yang W, Magee R, Schleibinger H (2008). Can long-term emissions be predicted with models based on short-term emissions? In: Proceedings of Indoor Air 2008, Copenhagen, Denmark.

    Google Scholar 

  • Xiong J, Yao Y, Zhang Y (2011). C-History method: Rapid measurement of the initial emittable concentration, diffusion and partition coefficients for formaldehyde and VOCs in building materials. Environmental Science & Technology, 45: 3584–3590.

    Article  Google Scholar 

  • Xiong J, Wei W, Huang S, Zhang Y (2013). Association between the emission rate and temperature for chemical pollutants in building materials: General correlation and understanding. Environmental Science & Technology, 47: 8540–8547.

    Article  Google Scholar 

  • Xu Y, Zhang Y (2003). An improved mass transfer based model for analyzing VOC emissions from building materials. Atmospheric Environment, 37: 2497–2505.

    Article  Google Scholar 

  • Ye W, Little JC, Won D, Zhang X (2014a). Screening-level estimates of indoor exposure to volatile organic compounds emitted from building materials. Building and Environment, 75: 58–66.

    Article  Google Scholar 

  • Ye W, Won D, Zhang X (2014b). A preliminary ventilation rate determination methods study for residential buildings and offices based on VOC emission database. Building and Environment, 79: 168–180.

    Article  Google Scholar 

  • Zhang Y, Xiong J, Mo J, Gong M, Cao J (2016). Understanding and controlling airborne organic compounds in the indoor environment: Mass transfer analysis and applications. Indoor Air, 26: 39–60.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wei Ye.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ye, W., Won, D. & Zhang, X. Examining the applicability of empirical models using short-term VOC emissions data from building materials to predict long-term emissions. Build. Simul. 9, 701–715 (2016). https://doi.org/10.1007/s12273-016-0302-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-016-0302-7

Keywords

Navigation