This paper describes the optimized design of a knee joint for an active transfemoral prosthesis with a fully active knee joint. The active transfemoral prosthesis which can help amputees to walk naturally with a powered motor has been actively developed around the world with advances in battery technology and others. However, most of them are designed for level walking, especially in South Korea, research about active prosthesis is insufficiently carried out, also depends on foreign technology. Therefore, this study focuses on the development of prosthetic knee joint that can overcome complex walking environment including stair walking. The developed prosthesis has one degree of freedom at the knee joint and can mimic the human walking mechanism. The prosthetic knee joint has a simple high-torque mechanism comprising a flat BLDC motor, harmonic drive, and pulley to generate the torque required for walking on stairs, which requires the largest torque. As one of the most important factors for comfort and fatigue, the total weight of the prosthesis should be minimized. Topology optimization was carried out to reduce the weight, and an advanced knee joint design was developed based on the optimization. The structural safety was validated via finite element analysis and a strain experiment under working conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ministry of Employment and Labor of Korea, 2014 statistics of disabled, Report for Employment Development Institute of Korea, Report no. Statistic Survey 2014-04, December (2014) 25–29.

    Google Scholar 

  2. Ministry of Health and Welfare of Korea, 2011 report of an actual condition on disability, Report no. 11-1352000-000568-12, 127-130.

  3. F. Sup, H. A. Varol, J. Mitchell, T. J. Withrow and M. Goldfarb, Self-contained powered knee and ankle prosthesis: Initial evaluation on a transfemoral amputee, IEEE 11th International Conference on Rehabilitation Robotics (2009) 638–644.

    Google Scholar 

  4. E. C. Martinez-Villalpando and H. Herr, Agonistantagonist active knee prosthesis: A preliminary study in level-ground walking, Journal of Rehabilitation Research & Development, 46 (3) (2009) 361–374.

    Article  Google Scholar 

  5. C.-Y. Ko, S.-B. Kim, J. K. Kim, Y. Chang, H. Cho, S. Kim, J. Ryu and M. Mun, Biomechanical features of level walking by transtibial amputees wearing prosthetic feet with and without adaptive ankles, Journal of Mechanical Science and Technology, 30 (6) (2016) 2907–2914.

    Article  Google Scholar 

  6. F. Sup, H. A. Varol and M. Goldfarb, Upslope walking with a powered knee and ankle prosthesis: Initial results with an amputee subject, IEEE Transactions on Neural Systems and Rehabilitation Engineering, 19 (1) (2011) 71–78.

    Article  Google Scholar 

  7. M. Omasta, D. Palousk, T. Navrat and J. Rosicky, Finite element analysis for the evaluation of the structural behavior, of aprosthesis for trans-tibial amputees, Medical Engineering & Physics, 34 (1) (2012) 38–45.

    Article  Google Scholar 

  8. S. M. Jaegersa, J. H. Arendzenb and H. J. de Jongha, Prosthetic gait of unilateral transfemoral amputees: A kinematic study, Archives of Physical Medicine and Rehabilitation, 76 (8) (1995) 736–743.

    Article  Google Scholar 

  9. R. Riener, M. Rabuffetti and C. Frigo, Stair ascent and descent at different inclinations, Gait and Posture, 15 (1) (2002) 32–44.

    Article  Google Scholar 

  10. P. Kang, J. H. Kim and J. S. Roh, Pressure distribution in stump/socket interface in response to socket flexion angle changes in trans-tibial prostheses with silicone liner, Physical Therapy Korea, 13 (4) (2006) 71–78.

    Google Scholar 

  11. H. A. M. Seelen, S. Anemaat, H. M. H. Janssen and J. H. M. Deckers, Effects of prosthesis alignment on pressure distribution at the stump/socket interface in transtibial amputees during unsupported stance and gait, Clinical Rehabilitation, 17 (7) (2003) 787–796.

    Article  Google Scholar 

  12. M. S. Pinzur, W. Cox, J. Kaiser, T. Morris, A. Patwardhan and L. Vrbos, The effect of prosthetic alignment on relative limb loading in persons with transtibial amputation: A preliminary, Journal of Rehabilitation Research & Development, 32 (4) (1995) 373–377.

    Google Scholar 

  13. K. H. Ha, H. A. Varol and M. Goldfarb, Volitional control of a prosthetic knee using surface electromyography, IEEE Transactions on Biomedical Engineering, 58 (1) (2011) 144–151.

    Article  Google Scholar 

  14. S. Au, M. Berniker and H. Herr, Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits, Neural Networks, 21 (4) (2008) 654–666.

    Article  Google Scholar 

  15. B. E. Lawson, H. A. Varol, A. Huff, E. Erdemir and M. Goldfarb, Control of stair ascent and descent with a powered transfemoral prosthesis, IEEE Transactions on Neural Systems and Rehabilitation Engineering, 21 (3) (2013) 466–473.

    Article  Google Scholar 

  16. R. D. Bellman, M. Holgate and T. G. Sugar, Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics, Proceedings of the 2nd Biennial IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (2008) 511–516.

    Google Scholar 

  17. R. Borjian, J. Lim, M. B. Khamesee and W. Melek, The design of an intelligent mechanical active prosthetic knee, Industrial Electronics, IECON 2008. 34th Annual Conference of IEEE (2008) 3016–3021.

    Google Scholar 

  18. W. C. Flowers and R. W. Mann, Electrohydraulic kneetorque controller for a prosthesis simulator, ASME Journal of Biomechanical Engineering, 99 (4) (1977) 3–8.

    Article  Google Scholar 

  19. K. H. Lee, J. H. Chung and C. H. Lee, Design and optimization study of active trasfemoral prosthesis leg, Journal of Rehabilitation Welfare Engineering & Assistive Technology, 7 (2) (2013) 41–46.

    Google Scholar 

  20. U. J. Yang and J. Y. Kim, Mechanical design of powered prosthetic leg and walking pattern generation based on motion capture data, Advanced Robotics, 29 (16) (2015) 1061–1079.

    Article  Google Scholar 

  21. F. Sup, A. Bohara and M. Goldfarb, Design and control of a powered transfemoral prosthesis, The International Journal of Robotics Research, 27 (2) (2008) 263–273.

    Article  Google Scholar 

  22. M. P. Bendsøe and N. Kikuchi, Generating optimal topologies in structural design using a homogenization method, Computer Methods in Applied Mechanics and Engineering, 71 (2) (1988) 197–224.

    Article  MathSciNet  MATH  Google Scholar 

  23. Z. Luo, N. Zhang, Y. Wang and W. Gao, Topology optimization of structures using meshless density variable approximants, International Journal for Numerical Methods in Engineering, 93 (4) (2012) 443–464.

    Article  MathSciNet  MATH  Google Scholar 

  24. J. T. Pereira, E. A. Fancello and C. S. Barcellos, Topology optimization of continuum structures with material failure constraints, Structural and Multidisciplinary Optimization, 26 (1) (2004) 50–66.

    Article  MathSciNet  MATH  Google Scholar 

  25. S. H. Cha, S. W. Lee and S. H. Cho, Experimental validation of topology design optimization, Computational Structural Engineering Institute of Korea, 26 (4) (2013) 241–246.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chul-Hee Lee.

Additional information

Recommended by Associate Editor Yoon Hyuk Kim

Hyoung-Jong Ahn received his Bachelor of Science degree in 2015 from Mechanical Engineering, Inha University, Korea. He is a master student in the Department of Mechanical Engineering, Inha University, Korea. His research interests are in the areas of medical devices, structural FE analysis and optimization.

Chul-Hee Lee is a Professor in the School of Mechanical Engineering, Inha University, Korea. He received his Bachelor of Science degree in 1994 and Master of Science degree in 1996, both from Mechanical Engineering, Inha University, Korea, and his Doctor of philosophy degree in 2006 from Mechanical & Industrial Engineering, University of Illinois at Urbana-Champaign, USA. His research interests are in the areas of transportation-vehicle components design and controls, tribology (Friction, adhesion, wear and lubrication), structural FE analysis and optimization, vehicle dynamic and vibration analysis, smart materials and mechanical control.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ahn, HJ., Lee, KH. & Lee, CH. Design optimization of a knee joint for an active transfemoral prosthesis for weight reduction. J Mech Sci Technol 31, 5905–5913 (2017). https://doi.org/10.1007/s12206-017-1134-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12206-017-1134-9

Keywords

Navigation