Abstract
In this research, a T-type Perfobond rib shear connector for steel concrete composite bridges is suggested, and a series of push-out tests are performed with numerous parameters, such as length and thickness of the ribs, diameter and number of the holes in the ribs, number of transversal reinforcing steel bars, and strength of concrete. Based on the test results, the effect of each parameter is analysed. Also, a shear strength evaluation formula is suggested for a 400 mm long T-type Perfobond rib shear connector. Comparison of the test results and the calculation results, using the suggested formula, validates that the suggested formula rationally evaluates the effect of considering parameters.
Similar content being viewed by others
References
Cândido-Martins, J. P. S., Costa-Neves, L. F., and Vellasco, P. C. G. da S. (2010). “Experimental evaluation of the structural response of Perfobond shear connectors.” Engineering Structures, Vol. 32, Issue 8, pp. 1976–1985, DOI: 10.1016/j.engstruct.2010.02.031.
Chung, C. H. and Lee, H. S. (2005). “Evaluation of shear of the G type Perfobond rib shear connectors.” Journal of The Korean Society of Civil Engineers, Vol. 25, No. 5A, pp. 879–888.
Eurocode 4. ENV (1994). Design of composite steel and concrete structures, European Committee for Standardisation (CEN).
Josef, M. and Jiri, S. (2002) “Perforated shear connectors.” Steel and Composite Structures, Vol. 2, No. 1, pp. 51–66.
Leonhardt, F., Andr, W., Andr, H. P., and Harre, W. (1987). “Neues, vorteilhaftes verbundmittel fur stahlverbund-tragwerke mit hoher dauerfestigkeit (New improved shear connector with high fatigue strength for composite structures).” Beton und Stahlbetonbau Heft, Vol. 82, Issue 12, pp. 325–331.
Oguejiofor, E. C. and Hosain, M. U. (1994). “A parametric study of perfobond rib shear connectors.” Canadian Journal of Civil Engineering, Vol. 21, No. 4, pp. 614–625, DOI: 10.1139/l94-063.
Oguejiofor, E. C. and Hosain, M. U. (1997). “Numerical Analysis of Push-out Specimens with Perfob-ond Rib Connectors.” Computers & Structures, Vol. 62, No. 4, pp. 617–624, DOI: 10.1016/S0045-7949(96)00270-2.
Oguejiofor, E. C. and Hosain, M. U. (1992). “Behaviour of Perfobond rib shear connectors in composite beam: Full size tests.” Canadian Journal of Civil Engineering, Vol. 19, No. 2, pp. 224–235, DOI: 10.1139/l92-028.
Sara, B. M. and Bahram, M. S. (2002). “Perfobond shear connector for composite construction.” Engineering Journal, First Quarter, pp. 2–12.
Vianna, J. da. C., Costa-Neves, L. F., Vellasco, P. C. G. daS., and de Andrade, S. A. L. (2008). “Structural behaviour of T-Perfobond shear connectors in composite girders: An experimental approach.” Engineering Structures, Vol. 30, No. 9, pp. 2381–2391, DOI: 10.1016/j.engstruct.2008.01.015.
Vianna, J. da. C., Costa-Neves, L. F., Vellasco, P. C. G.daS., and de Andrade, S. A. L. (2009). “Experimental assessment of Perfobond and T-Perfobond shear connectorsí structural response.” Journal of Constructional Steel Research, Vol. 65, No. 2, pp. 408–421, DOI: 10.1016/j.jcsr.2008.02.011.
Xue, W., Ding, M., Wnag H., and Luo Z. (2008). “Static behaviour and theoretical model of stud shear connectors.” Journal of Bridge Engineering, Vol. 13, No. 6, pp. 623–634, DOI: 10.1061/(ASCE)1084-0702(2008)13:6(623).
Zellner, W. (1987). “Recent designs of composite bridges and a new type of shear connectors.” Composite Construction in Steel and Concrete, American Society of Civil Engineers, New York, NY, pp. 240–252.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Chung, C.H., Lee, J. & Kim, J.S. Shear strength of T-type Perfobond rib shear connectors. KSCE J Civ Eng 20, 1824–1834 (2016). https://doi.org/10.1007/s12205-015-0095-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12205-015-0095-8