Skip to main content
Log in

Shear strength of T-type Perfobond rib shear connectors

  • Structural Engineering
  • Published:
KSCE Journal of Civil Engineering Aims and scope

Abstract

In this research, a T-type Perfobond rib shear connector for steel concrete composite bridges is suggested, and a series of push-out tests are performed with numerous parameters, such as length and thickness of the ribs, diameter and number of the holes in the ribs, number of transversal reinforcing steel bars, and strength of concrete. Based on the test results, the effect of each parameter is analysed. Also, a shear strength evaluation formula is suggested for a 400 mm long T-type Perfobond rib shear connector. Comparison of the test results and the calculation results, using the suggested formula, validates that the suggested formula rationally evaluates the effect of considering parameters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cândido-Martins, J. P. S., Costa-Neves, L. F., and Vellasco, P. C. G. da S. (2010). “Experimental evaluation of the structural response of Perfobond shear connectors.” Engineering Structures, Vol. 32, Issue 8, pp. 1976–1985, DOI: 10.1016/j.engstruct.2010.02.031.

    Article  Google Scholar 

  • Chung, C. H. and Lee, H. S. (2005). “Evaluation of shear of the G type Perfobond rib shear connectors.” Journal of The Korean Society of Civil Engineers, Vol. 25, No. 5A, pp. 879–888.

    MathSciNet  Google Scholar 

  • Eurocode 4. ENV (1994). Design of composite steel and concrete structures, European Committee for Standardisation (CEN).

    Google Scholar 

  • Josef, M. and Jiri, S. (2002) “Perforated shear connectors.” Steel and Composite Structures, Vol. 2, No. 1, pp. 51–66.

    Article  Google Scholar 

  • Leonhardt, F., Andr, W., Andr, H. P., and Harre, W. (1987). “Neues, vorteilhaftes verbundmittel fur stahlverbund-tragwerke mit hoher dauerfestigkeit (New improved shear connector with high fatigue strength for composite structures).” Beton und Stahlbetonbau Heft, Vol. 82, Issue 12, pp. 325–331.

    Article  Google Scholar 

  • Oguejiofor, E. C. and Hosain, M. U. (1994). “A parametric study of perfobond rib shear connectors.” Canadian Journal of Civil Engineering, Vol. 21, No. 4, pp. 614–625, DOI: 10.1139/l94-063.

    Article  Google Scholar 

  • Oguejiofor, E. C. and Hosain, M. U. (1997). “Numerical Analysis of Push-out Specimens with Perfob-ond Rib Connectors.” Computers & Structures, Vol. 62, No. 4, pp. 617–624, DOI: 10.1016/S0045-7949(96)00270-2.

    Article  Google Scholar 

  • Oguejiofor, E. C. and Hosain, M. U. (1992). “Behaviour of Perfobond rib shear connectors in composite beam: Full size tests.” Canadian Journal of Civil Engineering, Vol. 19, No. 2, pp. 224–235, DOI: 10.1139/l92-028.

    Article  Google Scholar 

  • Sara, B. M. and Bahram, M. S. (2002). “Perfobond shear connector for composite construction.” Engineering Journal, First Quarter, pp. 2–12.

    Google Scholar 

  • Vianna, J. da. C., Costa-Neves, L. F., Vellasco, P. C. G. daS., and de Andrade, S. A. L. (2008). “Structural behaviour of T-Perfobond shear connectors in composite girders: An experimental approach.” Engineering Structures, Vol. 30, No. 9, pp. 2381–2391, DOI: 10.1016/j.engstruct.2008.01.015.

    Article  Google Scholar 

  • Vianna, J. da. C., Costa-Neves, L. F., Vellasco, P. C. G.daS., and de Andrade, S. A. L. (2009). “Experimental assessment of Perfobond and T-Perfobond shear connectorsí structural response.” Journal of Constructional Steel Research, Vol. 65, No. 2, pp. 408–421, DOI: 10.1016/j.jcsr.2008.02.011.

    Article  Google Scholar 

  • Xue, W., Ding, M., Wnag H., and Luo Z. (2008). “Static behaviour and theoretical model of stud shear connectors.” Journal of Bridge Engineering, Vol. 13, No. 6, pp. 623–634, DOI: 10.1061/(ASCE)1084-0702(2008)13:6(623).

    Article  Google Scholar 

  • Zellner, W. (1987). “Recent designs of composite bridges and a new type of shear connectors.” Composite Construction in Steel and Concrete, American Society of Civil Engineers, New York, NY, pp. 240–252.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jungwhee Lee.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chung, C.H., Lee, J. & Kim, J.S. Shear strength of T-type Perfobond rib shear connectors. KSCE J Civ Eng 20, 1824–1834 (2016). https://doi.org/10.1007/s12205-015-0095-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12205-015-0095-8

Keywords

Navigation