Radiation doses for pregnant women in the late pregnancy undergoing fetal-computed tomography: a comparison of dosimetry and Monte Carlo simulations

  • Published:
Radiological Physics and Technology Aims and scope Submit manuscript

Abstract

The purposes of this study were (1) to compare the radiation doses for 320- and 80-row fetal-computed tomography (CT), estimated using thermoluminescent dosimeters (TLDs) and the ImPACT Calculator (hereinafter referred to as the “CT dosimetry software”), for a woman in her late pregnancy and her fetus and (2) to estimate the overlapped fetal radiation dose from a 320-row CT examination using two different estimation methods of the CT dosimetry software. The direct TLD data in the present study were obtained from a previous study. The exposure parameters used for TLD measurements were entered into the CT dosimetry software, and the appropriate radiation dose for the pregnant woman and her fetus was estimated. When the whole organs (e.g., the colon, small intestine, and ovaries) and the fetus were included in the scan range, the difference in the estimated doses between the TLD measurement and the CT dosimetry software measurement was <1 mGy (<23 %) in both CT units. In addition, when the whole organs were within the scan range, the CT dosimetry software was used for evaluating the fetal radiation dose and organ-specific doses for the woman in the late pregnancy. The conventional method using the CT dosimetry software cannot take into account the overlap between volumetric sections. Therefore, the conventional method using a 320-row CT unit in a wide-volume mode might result in the underestimation of radiation doses for the fetus and the colon, small intestine, and ovaries.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Miyazaki O, Sawai H, Murotsuki J, Nishimura G, Horiuchi T. Nationwide radiation dose survey of computed tomography for fetal skeletal dysplasias. Pediatr Radiol. 2014;44:971–9.

    Article  PubMed  Google Scholar 

  2. Miyazaki O, Nishimura G, Sago H, Horiuchi T, Hayashi S, Kosaki R. Prenatal diagnosis of fetal skeletal dysplasia with 3D CT. Pediatr Radiol. 2012;42:842–52.

    Article  PubMed  Google Scholar 

  3. Victoria T, Epelman M, Bebbington M, Johnson AM, Kramer S, Wilson RD, et al. Low-dose fetal CT for evaluation of severe congenital skeletal anomalies: preliminary experience. Pediatr Radiol. 2012;42:142–9.

    Article  Google Scholar 

  4. Ruano R, Molho M, Roume J, Ville Y. Prenatal diagnosis of fetal skeletal dysplasias by combining two-dimensional and three-dimensional ultrasound and intrauterine three-dimensional helical computer tomography. Ultrasound Obstet Gynecol. 2004;24:134–40.

    Article  CAS  PubMed  Google Scholar 

  5. Suzumura H, Kohno T, Nishimura G, Watanabe H, Arisaka O. Prenatal diagnosis of hypochondrogenesis using fetal MRI: a case report. Pediatr Radiol. 2002;32:373–5.

    Article  PubMed  Google Scholar 

  6. Cassart M. Suspected fetal skeletal malformations or bone diseases: how to explore. Pediatr Radiol. 2010;40:1046–51.

    Article  PubMed  Google Scholar 

  7. The International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publ. 2007;103:1–332.

    Google Scholar 

  8. Chida K, Ohno T, Kakizaki S, Takegawa M, Yuuki H, Nakada M, et al. Radiation dose to the pediatric cardiac catheterization and intervention patient. Am J Roentgenol. 2010;195:1175–9.

    Article  Google Scholar 

  9. Doshi SK, Negus IS, Oduko JM. Fetal radiation dose from CT pulmonary angiography in late pregnancy: a phantom study. Br J Radiol. 2008;81:653–8.

    Article  CAS  PubMed  Google Scholar 

  10. Angel E, Wellnitz CV, Goodsitt MM, Yaghmai N, DeMarco JJ, Cagnon CH, et al. Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte Carlo simulations estimating fetal dose for a range of gestational age and patient size. Radiology. 2008;249:220–7.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Gu J, Xu XG, Caracappa PF, Liu B. Fetal doses to pregnant patients from CT with tube current modulation calculated using monte carlo simulations and realistic phantoms. Radiat Prot Dosim. 2013;155:64–72.

    Article  Google Scholar 

  12. Victoria T, Epelman M, Coleman BG, Horii S, Oliver ER, Mahboubi S, et al. Low-dose fetal CT in the prenatal evaluation of skeletal dysplasias and other severe skeletal abnormalities. Am J Roentgenol. 2013;200:989–1000.

    Article  Google Scholar 

  13. Impactscan.org [homepage on the Internet]. London: the ImPACT CT scanner evaluation group, Inc.; c2000-01 [updated 2011 May; cited 2015 Sep 23]. http://www.impactscan.org/. Accessed 23 Sept 2015.

  14. Hurwitz LM, Yoshizumi T, Reiman RE, Goodman PC, Paulson EK, Frush DP, et al. Radiation dose to the fetus from body MDCT during early gestation. Am J Roentgenol. 2006;186:871–6.

    Article  Google Scholar 

  15. Matsunaga Y, Kawaguchi A, Kobayashi M, Suzuki S, Suzuki S. Dose evaluation for foetal computed tomography with a 320-row unit in wide-volume mode and an 80-row unit in helical scanning mode: a phantom study. Radiat Prot Dosim. 2015;168:523–30.

    Article  Google Scholar 

  16. Okabe K, Sugimoto H. A study on how to design comfortable maternity trousers which adjust to body changes during pregnancy. J Home Econ Jpn. 2007;58:763–70.

    Google Scholar 

  17. Kobayashi M, Koshida K, Suzuki S, Katada K. Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner. Radiol Phys Technol. 2012;5:148–55.

    Article  PubMed  Google Scholar 

  18. Ma H, Elbakri I, Reed M. Estimation of organ and effective doses from newborn radiography of the chest and abdomen. Radiat Prot Dosim. 2013;156:160–7.

    Article  Google Scholar 

  19. Kobayashi M, Asada Y, Matsubara K, Matsunaga Y, Kawaguchi A, Katada K, et al. Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry. J Appl Clin Med Phys. 2014;15:246–56.

    Article  Google Scholar 

  20. Kawaguchi A, Matsunaga Y, Kobayashi M, Suzuki S, Matsubara K. Effect of tube current modulation for dose estimation using a simulation tool on body CT examination. Radiat Prot Dosimetry. 2014;167:562–8.

    Article  PubMed  Google Scholar 

  21. Matsubara K, Koshida K, Noto K, Shimono T, Yamamoto T, Matsui O. Relationship between specific organ doses and volumetric CT dose indices in multidetector CT studies. J Med Imaging Radiat Oncol. 2011;55:493–7.

    Article  PubMed  Google Scholar 

  22. Groves AM, Owen KE, Courtney HM, Yates SJ, Goldstone KE, Blake GM, et al. 16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulation. Br J Radiol. 2004;77:662–5.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yuta Matsunaga.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Matsunaga, Y., Kawaguchi, A., Kobayashi, M. et al. Radiation doses for pregnant women in the late pregnancy undergoing fetal-computed tomography: a comparison of dosimetry and Monte Carlo simulations. Radiol Phys Technol 10, 148–154 (2017). https://doi.org/10.1007/s12194-016-0377-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12194-016-0377-y

Keywords

Navigation