Abstract
Stanozolol is one of the most widely used synthetic anabolic steroids but also presents a host of negative side effects. It is necessary to develop a rapid and sensitive method for stanozolol screening to monitor its abuse. In this study, the polyclonal antibody against stanozolol was prepared and a novel indirect competitive chemiluminescence enzyme immunoassay (CLEIA) for stanozolol was developed. The stanozolol hapten was conjugated to proteins to prepare immunogen and coating antigens, firstly. To improve the performances of the method, the chemiluminescent detection system was optimized. The optimal concentration of 4-iodophenol, hydrogen peroxide and luminol was studied and the proper detection time was also investigated. Under the optimal conditions, the IC50 value and the limit of detection (IC20) of the chemiluminescence immunoassay is 0.34 and 0.07 ng/mL in phosphate-buffered saline (PBS), respectively. The accuracy performances of the proposed CLEIA were compared with that of ELISA and HPLC. Different nutraceuticals, foodstuffs, and biological matrices spiked with stanozolol were applied to study the application of the proposed assays, and the average recoveries locate at 92–113 % with the coefficients of variation of 8–13.5 %. The polyclonal antibody-based chemiluminescence immunoassay formats are proved to be a feasible and reliable quantificational method for stanozolol.
Similar content being viewed by others
References
Choo H-YP, Kwon O-S, Park J (1990) Quantitative determination of stanozolol and its metabolite in urine by gas chromatography/mass spectrometry. J Anal Toxicol 14:109–112
Cirimele V, Kintz P, Ludes B (2000) Testing of the anabolic stanozolol in human hair by gas chromatography–negative ion chemical ionization mass spectrometry. J Chromatogr B Biomed Sci Appl 740:265–271
Clinton R, Manson A, Stonner F, Beyler A, Potts GO, Arnold A (1959) Steroidal [3, 2-c] pyrazoles. J Am Chem Soc 81:1513–1514
Fields R (1972) [38] The rapid determination of amino groups with TNBS. Methods Enzymol 25:464–468
Gehring AG, Albin DM, Irwin PL, Reed SA, Tu S-I (2006) Comparison of enzyme-linked immunomagnetic chemiluminescence with US Food and Drug Administration’s bacteriological analytical manual method for the detection of Escherichia coli O157: H7. J Microbiol Methods 67:527–533
Hermanson GT (1996) Bioconjugate techniques. Academic Press, San Diego
Höld KM, Wilkins DG, Crouch DJ, Rollins DE, Maes RA (1996) Detection of stanozolol in hair by negative ion chemical ionization mass spectrometry. J Anal Toxicol 20:345–349
Huenerbein A, Sı́poli Marques MA, dos Santos Pereira A, Radler de Aquino Neto F (2003) Improvement in steroid screening for doping control with special emphasis on stanozolol. J Chromatogr A 985:375–386
Kricka LJ (1998) Prospects for chemiluminescent and bioluminescent immunoassay and nucleic acid assays in food testing and the pharmaceutical industry. J Biolumin Chemilumin 13:189–193
Lin Z, Wang X, Li Z-J, Ren S-Q, Chen G-N, Ying X-T, Lin J-M (2008) Development of a sensitive, rapid, biotin–streptavidin based chemiluminescent enzyme immunoassay for human thyroid stimulating hormone. Talanta 75:965–972
Lumia AR, McGinnis MY (2010) Impact of anabolic androgenic steroids on adolescent males. Physiol Behav 100:199–204
Poelmans S, De Wasch K, De Brabander H, Van de Wiele M, Courtheyn D, Van Ginkel L, Sterk S, Delahaut P, Dubois M, Schilt R (2002) Analytical possibilities for the detection of stanozolol and its metabolites. Analytica chimica acta 473:39–47
Roberts A (2003) Side effects of steroids. J Steroid Biochem Mol Biol 84:369–375
Salvador J, Sánchez-Baeza F, Marco M (2008) Simultaneous immunochemical detection of stanozolol and the main human metabolite, 3′-hydroxy-stanozolol, in urine and serum samples. Anal Biochem 376:221–228
Sreenath K, Venkatesh YP (2007) Reductively aminated d-xylose–albumin conjugate as the immunogen for generation of IgG and IgE antibodies specific to d-xylitol, a haptenic allergen. Bioconjug Chem 18:1995–2003
Sun J, Wang S, Dong T (2009) A rapid and sensitive chemiluminescence enzyme linked immunosorbent assay for the determination of metolcarb residue in agricultural products. Bioinformatics and Biomedical Engineering, 2009 ICBBE 2009 3rd International Conference on. IEEE, pp 1–4
Tao X, Jiang H, Yu X, Zhu J, Wang X, Wang Z, Niu L, Wu X, Xia X, Shi W (2012) Development and validation of a chemiluminescent ELISA for simultaneous determination of florfenicol and its metabolite florfenicol amine in chicken muscle. Anal Methods 4:4083–4090
Tao X, Jiang H, Yu X, Zhu J, Wang X, Wang Z, Niu L, Wu X, Shen J (2013) Simultaneous determination of chloramphenicol, florfenicol and florfenicol amine in ham sausage with a hybrid chemiluminescent immunoassay. Food Addit Contam, Part A 30:804–812
Tao X, Chen M, Jiang H, Shen J, Wang Z, Wang X, Wu X, Wen K (2013) Chemiluminescence competitive indirect enzyme immunoassay for 20 fluoroquinolone residues in fish and shrimp based on a single-chain variable fragment. Anal Bioanal Chem 405:7477–7484
Tao X, Shen J, Cao X, Wang Z, Wu X, Jiang H (2014) Simultaneous determination of chloramphenicol and clenbuterol in milk with hybrid chemiluminescence immunoassays. Anal Methods 6:1021–1027
Van de Wiele M, De Wasch K, Vercammen J, Courtheyn D, De Brabander H, Impens S (2000) Determination of 16β-hydroxystanozolol in urine and faeces by liquid chromatography–multiple mass spectrometry. J Chromatogr A 904:203–209
Wang P, Yin Y, Eremin SA, Rybakov VB, Zhang T, Xu Z, Ren L, He X, Meng M, Xi R (2013) Indirect competitive immunoassay for detection of vitamin B2 in foods and pharmaceuticals. J Agric Food Chem 61:7048–7054. doi: 10.1021/jf401078t
Wu J-E, Chang C, Ding W-P, He D-P (2008) Determination of florfenicol amine residues in animal edible tissues by an indirect competitive ELISA. J Agric Food Chem 56:8261–8267
Xiao Q, Li H, Hu G, Wang H, Li Z, Lin J-M (2009) Development of a rapid and sensitive magnetic chemiluminescent enzyme immunoassay for detection of luteinizing hormone in human serum. Clin Biochem 42:1461–1467
Yan-Li L, Fei Y, Song-Cheng Y, Yong-Jun W, Hong-Quan Z, Ling-Bo Q (2012) Effect of the luminol signal enhancer on the chemiluminescence intensity and kinetics. J Lumin 132:1021–1024
Zhao, Lin J-M (2005) Development of a micro-plate magnetic chemiluminescence enzyme immunoassay (MMCLEIA) for rapid-and high-throughput analysis of 17β-estradiol in water samples. J Biotechnol 118:177–186
Acknowledgements
This work was supported by International Science & Technology Cooperation Program of China (no. 2015DFR40460); the financial support of National Natural Science Foundation (nos. 81173017, 31101277, 81402896); the National High-Tech Research and the Development Program of China (863 Program, no. 2014AA022303); and Tianjin Research Program of Application Foundation and Advanced Technology (13JCZDJC29700). We also appreciate the support from State Key Laboratory of Medicinal Chemical Biology (201503013), Nankai University.
Conflict of Interest
All of the authors (including Jing Wang, Lei Zheng, Yaqing Dong, Zhaorui Song, Yufen Wang, Meng Meng, Linlin Ren, Sergei A. Eremin, Chuan Deng, Yongmei Yin, Rimo Xi) declare that they have no conflict of interest.
Compliance with Ethical Standards
This article does not contain any studies with human subjects. Studies on animals were performed following all institutional and national guidelines for the care and use of laboratory animals, which were also mentioned in the Methods sections.
Author information
Authors and Affiliations
Corresponding authors
Additional information
Jing Wang and Lei Zheng contributed equally to this work.
Rights and permissions
About this article
Cite this article
Wang, J., Zheng, L., Dong, Y. et al. Establishment of Enhanced Chemiluminescent Immunoassay Formats for Stanozolol Detection in animal-derived foodstuffs and Other Matrices. Food Anal. Methods 9, 1284–1292 (2016). https://doi.org/10.1007/s12161-015-0307-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12161-015-0307-3