Introduction

Absolute quantification of regional myocardial blood flow (MBF) and myocardial flow reserve (MFR) on PET scans enables comprehensive evaluation of asymptomatic and symptomatic coronary artery disease (CAD) [1,2,3].

The most widely used tracers for myocardial PET scans are 15O-water, 13N-ammonia, and 82Rb which have short physical half-lives (2 min, 10 min, and 76 s, respectively) [1, 2, 4, 5]. Although 15O-water is a physiologically ideal myocardial perfusion agent because of its high first-pass extraction fraction and metabolically inert property, its clinical use is limited because of rapid equilibrium between myocardium and the blood pool and poor image quality [2]. 13N-ammonia yields markedly better image quality than 15O-water because 13N-ammonia is a soluble substance trapped in the myocardium and it has longer half-life and shorter positron range than 15O [1]. However, the requirement of an on-site cyclotron and synthesis module prevents wide clinical use of 13N-ammonia [4, 6]. In contrast, 82Rb does not require an on-site cyclotron and synthesis module, and its short half-life allows rapid rest and stress imaging studies for evaluating MFR. Thus, 82Rb is currently more widely used for clinical purposes [1, 4,5,6]. However, 82Rb PET has the limitation of relatively poor image quality because of its low extraction fraction and long positron range [1, 4, 5, 7, 8]. In addition, the high cost of monthly replacement of the 82Sr/82Rb generator limits the use of this tracer to large medical centers [6,7,8,9].

The development of 18F-labeled myocardial PET tracers was motivated by the limitations of the existing myocardial perfusion imaging agents for PET [1, 2, 7,8,9,10,11,12]. The long half-life of 18F (110 min) allows more counts on the PET image, treadmill exercise for stress imaging, and delivery of labeled tracer to hospitals that do not have a cyclotron [1, 8, 9]. 18F also yields better PET spatial resolution than other radioisotopes because of its shorter positron range (i.e., seven times shorter than 82Rb) [4, 8, 9].

(18F-fluoropentyl)triphenylphosphonium salt (18F-FPTP) is a promising 18F-labeled myocardial imaging agent for PET, specifically accumulating to a high degree in cardiomyocytes via a negative inner transmembrane potential of mitochondria (Fig. 1; Suppl. Figure 1) [13,14,15]. It was also shown that 18F-FPTP has greater first-pass myocardial extraction than 13N-ammonia in isolated perfused rat heart, indicating the suitability of 18F-FPTP as a quantitative myocardial PET imaging agent [14, 15]. In addition, no metabolite was detected in the serum of mice 30 min after intravenous injection of 18F-FPTP, implying that the metabolite correction would not be necessary in the kinetic analysis of 18F-FPTP myocardial PET data [13]. There was also a strong correlation between myocardial defect size measured by 18F-FPTP PET and the hypoperfused area measured by quantitative 2,3,5-triphenyltetrazolium chloride staining in a rat myocardial infarction (MI) model [16]. Rapid washout from the liver is another merit of 18F-FPTP, which is advantageous during the evaluation of lateral myocardial wall uptake [2, 5, 15, 16].

Fig. 1
figure 1

Spatiotemporal distribution of 18F-FPTP. a Serial positron emission tomography (PET) scan data from a rat with myocardial infarction showing rapid accumulation of 18F-FPTP in the myocardium and the marked contrast between normal myocardium and other neighboring organs such as liver and lung. b Short-axis, vertical long-axis, and horizontal long-axis images and a polar map of 18F-FPTP PET data summed between 1 and 18 min after contrast injection

In this study, we performed compartmental analysis on rat 18F-FPTP PET images to identify the most suitable compartment model. We then evaluated two linear analysis methods for estimating the robust kinetic parameters and generating parametric images. The minimum dynamic scan duration for kinetic analysis was also investigated. In addition, computer simulation studies were performed to confirm the two linear methods results.

Materials and methods

Radiochemistry

The radiotracer 18F-FPTP was prepared as described in a previous study [13].

Animal model

All procedures in this study were approved by the Chonnam National University Animal Research Committee and the Guide for the Care and Use of Laboratory Animals. In this study, we used 8-week-old male Sprague–Dawley rats (n = 12, weight 250–260 g). To induce MI, left coronary artery occlusion surgery was performed on the rats 1 day before the PET scans.

PET/CT procedure

Among twelve rat PET/CT data, three data acquired in our previous study [13] were included and reconstructed with our new time frame for the purposes of the current work and remaining nine data were newly acquired. In these studies, a small animal dedicated PET/CT scanner (Inveon; Siemens Medical Solutions, Knoxville, TN) was used. Dynamic PET was started with an intravenous tail-vein injection of 18F-FPTP and continued for 18 min (5 × 1 s, 5 × 5 s, 3 × 10 s, 4 × 15 s, 16 × 30 s, 8 × 60 s). PET images were reconstructed with 128 × 128 × 159 matrices of 0.78 × 0.78 × 0.80-mm voxel size using a filtered back-projection algorithm (Ramp filter, cutoff = 0.5). An X-ray CT transmission scan was performed after the PET scan.

Image analysis

Regions of interest (ROIs) for the left ventricular (LV) cavity, normal myocardium, and MI region were drawn on static PET images generated by accumulating PET counts from 1 to 18 min and co-registered with the CT images of each animal using MRIcro software (http://www.mricro.com). The LV ROI to obtain the image-derived input function for kinetic analysis was drawn on the center of the LV cavity through multiple transaxial slices with the size of 6–10 voxels per slice to avoid spillover contamination from the myocardial activity. The ROI for normal myocardium was drawn on the voxels located sufficiently far from the MI and centered in the automatically drawn peak activity contour along the myocardium. The CT information was supplementary and was used for drawing ROIs on MI regions (The MI ROIs were drawn only in 10 rats because the MI was not clearly induced in 2 rats). The time-activity curves were then extracted by applying these ROIs to the serial time frames of the PET data. No metabolite correction was applied to the LV input function [13]. Time-activity curves between 0 and 10 min were used for the kinetic analysis.

Rat mode in PMOD software (version 3.6; PMOD Technologies, Zurich, Switzerland) was used to generate polar map images of 18F-FPTP PET. FIRE software [17] was used to reorient static PET images and fusion between parametric images.

Compartment modeling: nonlinear analysis and model selection

To determine the suitable tracer kinetic model of 18F-FPTP PET, a two-compartment model with K 1 (ml/min/g) and k 2 (min−1) and a three-compartment model with irreversible uptake [K 1, k 2, and k 3 (min−1)] (Suppl. Figure 2) were compared in terms of goodness-of-fit for the tissue time-activity curves. The three-compartment model with reversible uptake was not considered because of the obvious irreversible characteristics of this tracer, as shown in the tissue time-activity curves (Fig. 2). In each compartment model tested, a blood volume fraction (V a ) term was incorporated in the operation equation for curve fitting [18,19,20,21,22,23]. The following equation shows how the V a is incorporated into the two-compartment model equation:

$$C_{\text{T}} \left( t \right) = \left( {1 - V_{a} } \right)K_{1} { \exp }( - k_{2} t) \otimes C_{a} (t) + V_{a} C_{a} (t)$$
(1)

where t is the time, C T (t) is the tissue time-activity curve, C a (t) is the arterial input function, and K 1 and k 2 are, respectively, the rate constants describing the uptake to and washout from the tissue compartment.

Fig. 2
figure 2

Left ventricular input function (black line) and tissue time-activity curves for a myocardial infarction (MI) region (filled circle), remote normal myocardium (open circle), liver (open triangle), and lung (open diamond) for two time scales (left 0–1 min, right 0–10 min). Fitting curves for the MI region and normal myocardium were obtained using two-compartment (red line) and three-compartment (blue line) models

For the model selection, the tissue time-activity curves were fitted to the models using a nonlinear least-squares (NLS) method based on the Levenberg–Marquardt algorithm [19, 24]. Akaike Information Criteria (AIC) were used to determine the most appropriate model for 18F-FPTP [25, 26].

Compartment modeling: linear analysis methods and parametric image generation

In addition to the NLS curve fitting, the kinetic parameters were estimated using linear analysis methods. These methods are less vulnerable to noise and provide much faster computation. They are useful for robust estimation of kinetic parameters and generation of their parametric images [20, 23, 27, 28]. The linear analysis methods were applied only to the two-compartment model because it turned out to be more appropriate than the three-compartment model for describing the kinetics of 18F-FPTP (see “Results” for more detail).

We adopted two linear analysis methods. One is the multiple linear least-squares (LLS) method modified from our previous approach to the kinetic analysis of 15O-water [20]. The other is the basis function method (BFM), which is another well-established linear method used to generate parametric images [21, 22, 28, 29].

In addition to the ROI analysis, the LLS and BFM methods were used to generate the parametric image of each kinetic parameter through the voxel-wise parameter estimation [21, 22, 28,29,30] and post-Gaussian filtering with 1-mm kernel size (full width at half maximum).

Simulation

We also performed a simulation study to explore the statistical properties of the estimation methods (NLS, LLS, BFM) tested for 18F-FPTP [20, 23, 27]. Average arterial input function of 18F-FPTP obtained from the rat studies was employed for the simulation study [20]. For generating simulated tissue time-activity curves, three levels of K 1 (2.0, 6.0, and 10.0 ml/min/g) were assumed, and V a and K 1/k 2 were fixed at 0.2 and 3.0, respectively, based on the results of rat studies. Poisson-like random noise generated with the consideration of activity and frame duration was added to the simulated tissue time-activity curves with six noise levels from 0 to 15 (voxel level time-activity curves in the rat studies had the noise level between 5 and 10) [20]. A total of 10,000 data sets were generated for each pair of K 1 and noise level [20]. Finally, the coefficient of variation (CV), bias, and error in the estimation of each parameter were calculated [20, 27].

Results

Spatiotemporal distribution of 18F-FPTP

Figure 1a shows the serial PET scan data of a rat, revealing the dynamic whole-body distribution of 18F-FPTP. Rapid clearance of 18F-FPTP from blood was observed in the LV cavity region. It had rapidly accumulated in normal myocardium and was highly sustained during the whole scan duration. The high contrast between normal and MI regions in the myocardium was also well maintained until the end of the PET scan. 18F-FPTP uptake in the liver was quite low, making great image contrast between myocardium and liver which will be useful for mitigating the incorrect estimation of tracer uptake in the lateral wall of the heart observed with other MPI tracers, such as 13N-ammonia [13].

Short-axis, vertical long-axis, and horizontal long-axis images and the polar map of 18F-FPTP PET data summed between 1 and 18 min after injection are shown in Fig. 1b. They show excellent image contrast between myocardial uptake of 18F-FPTP and the LV blood pool cavity. There is clear discrimination of the MI region in the anterolateral LV wall induced by occlusion of the left coronary artery from the myocardium with intact perfusion.

Figure 2 shows the representative LV input function and tissue time-activity curves for the MI region, remote normal myocardium, liver, and lung in two time scales (0–1 and 0–10 min) in a single rat, confirming the favorable spatiotemporal properties of 18F-FPTP as a myocardial PET imaging agent (Fig. 1). Myocardium/blood activity ratios were 3.83 ± 0.75 (mean ± standard deviation) at 5 min, 3.73 ± 0.53 at 10 min, and 3.67 ± 0.61 at 15 min. Representative activity ratio plots in a single rat are shown in Suppl. Figure 3. They indicate that 18F-FPTP quickly reaches equilibrium between the myocardium and blood in rats, which is sustained until the end of the PET scan with about a four times higher ratio in normal myocardium than in the MI region.

Nonlinear analysis and model selection

Both the two- and three-compartment model equations incorporated with V a yielded an excellent NLS curve fitting as shown in Fig. 2. Kinetic parameters estimated by the NLS method using the two- and three-compartment models and their AIC values are summarized in Table 1. Both models provided much lower K 1 values in the MI region relative to normal myocardium, but there were similar k 2 values between the normal and MI regions. The K 1, k 2, and V a values estimated using the two- and three-compartment models were comparable. The k 3 values estimated using the three-compartment model were negligibly small, and AIC values of the two-compartment model were lower than those of three-compartment model. Accordingly, the simpler model, the two-compartment model, was selected as the optimal model for describing 18F-FPTP kinetics, and it was employed for subsequent linear analysis methods.

Table 1 Comparison of kinetic parameters estimated using two-compartment and three-compartment models and goodness-of-fit

Linear analysis and parametric image

The kinetic parameters obtained using the LLS and BFM methods for a two-compartment model applied to the ROI time-activity curves are correlated with the NLS estimates from ROI time-activity curves in Fig. 3. All the parameters (K 1, k 2, V a ) estimated using LLS (Fig. 3a, c) and BFM (Fig. 3b, d) were well correlated with NLS estimates except for the low V a values. K 1 and k 2 estimates showed better correlation and less deviation than the V a values.

Fig. 3
figure 3

Scatter plot and Bland–Altman analysis of the kinetic parameters (K 1, k 2, V a ) obtained using two linear analysis methods—linear least-squares (LLS) and basis function method (BFM) for the two-compartment model applied to the region of interest (ROIs) time-activity curves and those using nonlinear least-squares (NLS) estimates from ROI time-activity curves. a, c LLS. b, d BFM. In a and b, different colors are used for the normal (blue) and MI (red) data

Figure 4 (short-axis) and Suppl. Figures 4 and 5 (vertical and horizontal long-axes) show the parametric images generated using NLS, LLS, and BFM. All three methods offered similar spatial distributions of kinetic parameters, but the two linear analysis methods (LLS and BFM) offered better image quality than NLS. The parametric images showed physiologically and physically relevant parameter distributions. The K 1 images representing the partial volume and spillover corrected uptake or perfusion showed the sharp contrast between normal myocardium and the MI region and the uniform K 1 distribution across the myocardium between the endocardial and epicardial walls. The αK 1 (α = 1 − V a ; perfusible tissue fraction or recovery coefficient [18, 19]) images offered the uptake ratio distribution weighted by partial volume effect (PVE)s. The V a images illustrated well the blood pool distribution, particularly in the left and right ventricles, and spillover of blood activity into the myocardium. All three methods showed uniform k 2 distribution in normal myocardium. However, the NLS and BFM methods provided too high and non-zero k 2 values in both ventricles, whereas the LLS method yielded k 2 parametric images with good contrast between myocardium and ventricles.

Fig. 4
figure 4

Parametric images of αK 1 (α = 1 − V a ), K 1, k 2 and V a generated using NLS, LLS, and BFM (short-axis)

Kinetic parameters were obtained by applying the ROIs to the parametric images and calculating the average parameter values within the ROIs, which were compared with the NLS estimates from ROI time-activity curves (Fig. 5a, c, LLS; Fig. 5b, d, BFM). The voxel-wise parameter estimation resulted in relatively higher K 1 values, especially in the voxels with high K 1.

Fig. 5
figure 5

Scatter plot and Bland–Altman analysis of the kinetic parameters (K 1, k 2, V a ) obtained by applying the ROIs onto the parametric images obtained using two linear analysis methods (LLS, BFM) and those using NLS estimates from ROI time-activity curves. a, c, LLS. b, d, BFM. In a and b, different colors are used for the normal (blue) and MI (red) data

Scan duration

Figure 6 shows the kinetic parameters estimated using different scan durations, indicating that 5- and 10-min data collections are sufficient for estimating kinetic parameters using ROI- and voxel-wise estimations, respectively. The K 1 value (the parameter of interest in MBF imaging) showed earlier convergence (even with only 3 min dynamic PET data) than other parameters in ROI analysis which is used in most clinical settings for MBF estimation.

Fig. 6
figure 6

Kinetic parameters estimated with different scan durations using the a NLS method on ROI time-activity curves, b LLS method on ROI time-activity curves, c BFM method on ROI time-activity curves, d LLS parametric images, and e BFM parametric images

Simulation study

Figure 7 shows the CV and bias in the estimation of each parameter using the NLS, LLS, and BFM methods. The LLS and BFM showed smaller CV in parameter estimation than NLS, and LLS was superior to BFM in the estimations of K 1 and k 2. The BFM was the best estimation method in terms of the bias, but the LLS showed relatively higher bias in a high K 1 level. Representative noisy time-activity curves for different noise levels are shown in Suppl. Figure 6.

Fig. 7
figure 7

Results of the simulation study: coefficients of variation (CV) (a) and bias (b) in the estimation of each parameter using the NLS (black symbols and lines), LLS (blue), and BFM (red) methods. Three K 1 levels were considered open circle 2.0, open triangle 6.0, open diamond 10.0

Discussion

In this study, we performed quantitative analysis on 18F-FPTP dynamic PET images from a rat model of MI to explore the spatiotemporal dynamics of this tracer, select a suitable tracer kinetic model for describing its kinetics, and investigate the properties of linear analysis methods for generating parametric images of kinetic parameters.

The model selection study for kinetic analysis suggests that the two-compartment model, which incorporates the K 1, k 2, and V a parameters, is suitable for describing the kinetics of 18F-FPTP in rat myocardium. The additional tissue compartment and kinetic parameters to distinguish the free and bound tracers in cellular space could not improve the quality of curve fitting, indicating fast equilibrium between the free and bound status of 18F-FPTP. Easy and robust quantification of myocardial perfusion will be possible because kinetic modeling of 18F-FPTP does not require metabolite correction and is based on the two-compartment model.

The simplicity of two-compartment model has led to the feasibility of relatively simple linear analysis methods (LLS, BFM) for the noisy ROI kinetic analysis and parametric image generation. In the simulation study, the LLS and BFM showed the lowest variation and bias, respectively (Fig. 7), in agreement with the indications shown in the parametric images generated based on them (Fig. 4). The high correlation between the parameters obtained using LLS and BFM methods and those from the NLS ROI analysis, which is the gold standard but requires a long computation time, has also verified the feasibility of the linear analysis methods (Figs. 5, 7). The parametric images of 18F-FPTP provided physiologically relevant results (Fig. 4; Suppl. Figures 4 and 5). The K 1 and αK 1 parametric images (flow-related images with and without partial volume correction) well accounted for the perfusion difference between normal myocardium and MI regions. Although the K 1 image provided partial volume-corrected perfusion information, the image quality was worse than that with αK 1, mainly because of the division operation required for obtaining K 1 values. The distribution of k 2 was more uniform than K 1 or αK 1, and V a images clearly showed the blood pool distribution in the heart. However, only the LLS showed good contrast between myocardium and the LV cavity in k 2 parametric images, which may be caused by the better parameter estimation performance of lower parameter values than attained with the other methods.

In this study, input function was obtained from LV pool of PET images. Although the kinetic model itself includes PVE, the input function is assumed to be free from the PVE as in our previous rat PET study [31]. However, the PVE on the input function is not avoidable sometimes even in the small animal dedicated PET scanners. Previously we have shown that LV input function in mice PET studies is underestimated by 5–10% relative to the arterial blood samples [32]. However, in this study, we used more advanced small animal PET scanner than the previous study (Inveon vs. Focus 120) [33,34,35]. In addition, rats have much larger LV cavity than mice, causing less severe PVE. In case there is the underestimation of LV input function due to the PVE, it would more influence on the K 1 and V a (overestimation) rather than k 2.

Usually, a weighting factor is considered for compensating the different signal-to-noise ratios (SNRs) among PET time frames because the different SNRs cause bias in parameter estimation. However, the weighting did not prove effective in this study for improving the bias properties and parametric image quality (Suppl. Figure 7; frame duration was used as the weighting factor). The weight would be more effective for the radiotracers with binding and dissociation as parameters of interest and the relatively short half-life of the radioisotope [27]. However, it seems that the slope of the early frames with rapid buildup and the ratio of tissue and blood activity in the later frames are the most dominant factors when determining the kinetic parameters of 18F-FPTP. The parameters determined mainly in each of these early and later portions of the time-activity curves are influenced very little by the weighting factors.

Conclusion

A novel, promising, myocardial PET imaging agent, 18F-FPTP, was quantitatively evaluated in rats with MI. For describing the kinetics of this tracer, a two-compartment model was more suitable than a three-compartment model. Two linear analyses for parametric image generation showed that the kinetic parameters were well correlated with nonlinearly estimated gold standard ones and yielded the high quality images of those parameters. The first 10 min of the dynamic scans was sufficient for obtaining accurate kinetic parameters in quantitative PET studies. Finally, the two algorithms for parametric mapping of 18F-FPTP in myocardium will be useful for further studies under different conditions, disease model, and species.