An implantable ENG detector with in-system velocity selective recording (VSR) capability

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Detection and classification of electroneurogram (ENG) signals in the peripheral nervous system can be achieved by velocity selective recording (VSR) using multi-electrode arrays. This paper describes an implantable VSR-based ENG recording system representing a significant development in the field since it is the first system of its type that can record naturally evoked ENG and be interfaced wirelessly using a low data rate transcutaneous link. The system consists of two CMOS ASICs one of which is placed close to the multi-electrode cuff array (MEC), whilst the other is mounted close to the wireless link. The digital ASIC provides the signal processing required to detect selectively ENG signals based on velocity. The design makes use of an original architecture that is suitable for implantation and reduces the required data rate for transmission to units placed outside the body. Complete measured electrical data from samples of the ASICs are presented that show that the system has the capability to record signals of amplitude as low as 0.5 μV, which is adequate for the recording of naturally evoked ENG. In addition, measurements of electrically evoked ENG from the explanted sciatic nerves of Xenopus Laevis frogs are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Brindley G, Rushton D (eds) (1995) Clinical neurology: neuroprostheses, vol 14, no 1. Baillieres-Tindall, London, pp 21–34

  2. Chew DJ, Zhu L et al (2013) A microchannel neuroprosthesis for bladder control after spinal cord injury in rat. Sci Trans Med 5:210ra155

    Article  Google Scholar 

  3. Clarke C, Xu X, Rieger R, Taylor J, Donaldson N (2009) An implanted system for multi-site nerve cuff-based ENG recording using velocity selectivity. Analog Integr Circuit Sign Process 58(2):91–104

    Article  Google Scholar 

  4. Donaldson PEK (1983) The Cooper cable—an implantable multiconductor cable for neurological prostheses. MBEC 21(3):371–374

    CAS  PubMed  Google Scholar 

  5. Haugland M, Hoffer J (1994) Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles. IEEE Trans Rehabil Eng 2:37–40

    Article  Google Scholar 

  6. Karimi F, Seydnejad S (2015) Velocity selective neural signal recording using a space-time electrode array. IEEE Trans Neural Syst Rehabil Eng 23(5):837–848

    Article  PubMed  Google Scholar 

  7. Metcalfe B, Chew D, Clarke C, Donaldson N, Taylor J (2015) A new method for spike extraction using velocity selective recording demonstrated with physiological ENG in Rat. J Neurosci Methods 251:47–55

    Article  CAS  PubMed  Google Scholar 

  8. Rieger R, Taylor J, Donaldson N et al (2006) Very low-noise ENG amplifier system using CMOS technology. IEEE Trans Neural Syst Rehabil Eng 14(4):427–437

    Article  PubMed  Google Scholar 

  9. Schuettler M, Donaldson N, Seetohul V, Taylor J (2013) Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff. J Neural Eng 10(3):03016

    Article  Google Scholar 

  10. Stieglitz T, Beutel H, Schuettler M, Meyer J (2000) Micromachined polyimide-based devices for flexible neural interfaces. Biomed Microdevices 2(4):283–294

    Article  Google Scholar 

  11. Taylor J, Donaldson N, Winter J (2004) Multiple-electrode nerve cuffs for low velocity and velocity-selective neural recording. Med Biol Eng Comput 42:634–643

    Article  CAS  PubMed  Google Scholar 

  12. Taylor J, Schuettler M, Clarke C, Donaldson N (2012) The theory of velocity selective neural recording: a study based on simulation. Med Biol Eng Comput 50(3):309–318

    Article  PubMed  Google Scholar 

  13. Vittoz E (1983) MOS transistors operated in the lateral bipolar mode and their application in CMOS technology. IEEE J. Solid-State Circuits SC-18(3):273–279

    Article  Google Scholar 

  14. Yoshida K, Kurstjens G, Hennings K (2009) Experimental validation of the nerve conduction velocity selective recording technique using a multi-contact cuff electrode. Med Eng Phys 31:1261–1270

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors would like to acknowledge funding support from the following sources: (1) European Commission Project title: Implantable Multi-contact Active Nerve Electrode (IMANE), project no. 026602; (2) Taiwan Ministry of Science and Technology (MOST) grant no. MOST 103-2221-E-110-026-MY2.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to John Taylor.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Clarke, C., Rieger, R., Schuettler, M. et al. An implantable ENG detector with in-system velocity selective recording (VSR) capability. Med Biol Eng Comput 55, 885–895 (2017). https://doi.org/10.1007/s11517-016-1567-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-016-1567-9

Keywords

Navigation