Abstract
Meat tenderness is a major factor in consumer satisfaction. Tenderness may be quantified by changes in muscle sarcomere length, roughness (ultrastructure) and shear force. The ultrastructure and the Warner-Bratzler shear force value of beef shank muscle fibers were experimentally measured in controlled applications of ultrasound and calcium chloride. Uncooked beef samples were treated with ultrasound at 40 kHz at different intensities for 6 min, and then immersed in a range of calcium chloride solutions for 24 h. Warner–Bratzler shear analysis and atomic force microscopy (AFM) data collection were performed for each sample. AFM height derived data (the sarcomere length and roughness values) and the Warner–Bratzler shear force values indicate optimum ranges of ultrasound intensity and calcium chloride concentration for meat tenderization. While the effect of low intensity ultrasound alone was not significant, calcium chloride treatment increased the sarcomere length and decreased shear force values. Furthermore, the combination of ultrasound and calcium chloride increased the sarcomere length significantly and simultaneously reduced the Warner–Bratzler shear force tolerance of the sample. These data suggested that low intensity and frequency ultrasound alongside Calcium Chloride immersion can promote the transmembrane transport of calcium ions via the calpain system to improve meat tenderness.
Similar content being viewed by others
References
M. Koohmaraie, Meat Sci. 43(S1), 193–201 (1996)
K.G. Grunert, Food Qual. Prefer. 8(3), 157–174 (1997)
S.D. Shackelford, T.L. Wheeler, M.K. Meade, J.O. Reagan, B.L. Byrnes, M. Koohmaraie, J. Anim. Sci. 79(10), 2605–2614 (2001)
K. Zor, R. Ortiz, E. Saatci, R. Bardsley, T. Parr, E. Csoregi, M. Nistor, Bioelectrochemistry 76(1–2), 93–99 (2009)
M.J. Colle, M.E. Doumit, Meat Sci. 131, 142–145 (2017)
A.D. Alarcon-Rojo, H. Janacua, J.C. Rodriguez, L. Paniwnyk, T.J. Mason, Meat Sci. 107, 86–93 (2015)
F. Turantas, G.B. Kilic, B. Kilic, Int. J. Food Microbiol. 198, 59–69 (2015)
K.S. Ojha, T.J. Mason, C.P. O'Donnell, J.P. Kerry, B.K. Tiwari, Ultrason. Sonochem. 34, 410–417 (2017)
S.D. Jayasooriya, P.J. Torley, B.R. D'Arcy, B.R. Bhandari, Meat Sci. 75(4), 628–639 (2007)
R.D. Warner, C.K. McDonnell, A.E.D. Bekhit, J. Claus, R. Vaskoska, A. Sikes, F.R. Dunshea, M. Ha, Meat Sci. 132, 72–89 (2017)
A.M. Herrero, L. de la Hoz, J.A. Ordonez, B. Herranz, M.D.R. de Avila, M.I. Cambero, Meat Sci. 80(3), 690–696 (2008)
M. Koohmaraie, G.H. Geesink, Meat Sci. 74(1), 34–43 (2006)
J. Li, J. Tan, P. Shatadal, Meat Sci. 57(4), 341–346 (2001)
A. Listrat, B. Lebret, I. Louveau, T. Astruc, M. Bonnet, L. Lefaucheur, B. Picard, J. Bugeon, TheScientificWorldJournal 2016, 3182746–3182746 (2016)
M.S. Rhee, T.L. Wheeler, S.D. Shackelford, M. Koohmaraie, J. Anim. Sci. 82(2), 534–550 (2004)
C.P. Starkey, G.H. Geesink, R. van de Ven, D.L. Hopkins, Meat Sci. 126, 18–21 (2017)
C.P. Starkey, G.H. Geesink, D. Collins, V.H. Oddy, D.L. Hopkins, Meat Sci. 113, 51–58 (2016)
B. Tiribilli, D. Bani, F. Quercioli, A. Ghirelli, M. Vassalli, Ultramicroscopy 102(3), 227–232 (2005)
D.M. Sango, D. Abela, A. McElhatton, V.P. Valdramidis, J. Appl. Microbiol. 116(5), 1067–1083 (2014)
X. Pang, L. Lin, B. Tang, Sci. Rep. 7, 46042 (2017)
E.L. Florin, V.T. Moy, H.E. Gaub, Science 264(5157), 415–417 (1994)
J. Zhu, T. Sabharwal, A. Kalyanasundaram, L. Guo, G. Wang, J. Biomech. 42(13), 2143–2150 (2009)
F. Chemat, H. Zill e, M.K. Khan, Ultrason. Sonochem. 18(4), 813–835 (2011)
G. Xiong, L. Zhang, W. Zhang, J. Wu, Czech J. Food Sci. 30(3), 195–205 (2012)
T.S. Awad, H.A. Moharram, O.E. Shaltout, D. Asker, M.M. Youssef, Food Res. Int. 48(2), 410–427 (2012)
F.W. Pohlman, M.E. Dikeman, J.F. Zayas, Meat Sci. 45(3), 329–337 (1997)
Z. Qian, R.D. Sagers, W.G. Pitt, Ann. Biomed. Eng. 25(1), 69–76 (1997)
D.G. Riley, D.D. Johnson, C.C. Chase, et al., Meat Sci. 70(2), 347–356 (2005)
C.P. Starkey, G.H. Geesink, D. Collins, O.V. Hutton, D.L. Hopkins, Meat Sci. 113, 51–58 (2016)
J. Gao, Y. Wang, L. Liu, K. Li, S. Zhang, J. Zhu, Scanning 38(6), 545–553 (2016)
M.A. da Silva Coutinho, P.M. Ramos, S. da Luz e Silva, L.S. Martello, A.S. Cravo Pereira, E.F. Delgado, Meat Sci. 134, 61–67 (2017)
M. Maki, E. Takano, T. Osawa, T. Ooi, T. Murachi, M. Hatanaka, J. Biol. Chem. 263(21), 10254–10261 (1988)
R.A. Hanna, B.E. Garcia-Diaz, P.L. Davies, FEBS Lett. 581(16), 2894–2898 (2007)
L. Uytterhaegen, E. Claeys, D. Demeyer, J. Anim. Sci. 72(5), 1209–1223 (1994)
P. Ertbjerg, E. Puolanne, Meat Sci. 132, 139–152 (2017)
Acknowledgements
This project was supported by Key Research and Development Plan of Shaanxi Province (2018NY-110, JZ), International S&T Cooperation Foundation of Northwest A&F University (2018, JZ), National Natural Science Foundation of China (11202170, JZ), National Beef and Yak Industrial Technology System (CARS-37, LZ), College Students’ Entrepreneurship Training Program of Shaanxi Province (S201710712095,YW), College Students’ Innovation Training Program of Northwest A&F University (1201710712108, WW). We would like to acknowledge Prof. Orgel at BioCAT of Argonne National Lab and Illinois Institute of Technology for his help on manuscript improvement and scientific discussion.
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Wan, Y., Wang, H., Wang, W. et al. Effect of Ultrasound and Calcium Chloride on the Ultrastructure and the Warner-Bratzler Shear Force Value of Beef Shank Muscle Fibers. Food Biophysics 13, 396–403 (2018). https://doi.org/10.1007/s11483-018-9545-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11483-018-9545-4