Characterization of particulate matter concentrations and bioaerosol on each floor at a building in Seoul, Korea

  • Research Article
  • Published:
Environmental Science and Pollution Research Aims and scope Submit manuscript

Abstract

Particulate matter (PM) in buildings are mostly sourced from the transport of outdoor particles through a heating, ventilation, and air conditioning (HVAC) system and generation of particle within the building itself. We investigated the concentrations and characteristic of indoor and outdoor particles and airborne bacteria concentrations across four floors of a building located in a high-traffic area. In all the floors we studied (first, second, fifth, and eighth), the average concentrations of particles less than 10 μm (PM10) in winter for were higher than those in summer. On average, a seasonal variation in the PM10 level was found for the first, fifth, and eighth floors, such that higher values occurred in the winter season, compared to the summer season. In addition, in winter, the indoor concentrations of PM10 on the first, fifth, and eighth floors were higher than those of the outdoor PM10. The maximum level of airborne bacteria concentration was found in a fifth floor office, which held a private academy school consisting of many students. Results indicated that the airborne bacteria remained at their highest concentration throughout the weekday period and varied by students’ activity. The correlation coefficient (R 2) and slope of linear approximation for the concentrations of particulate matter were used to evaluate the relationship between the indoor and outdoor particulate matter. These results can be used to predict both the indoor particle levels and the risk of personal exposure to airborne bacteria.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  • Adgate J, Mongin S, Prat G, Zhang J, Field M, Ramachandran G, Sexton K (2007) Relationships between personal, indoor, and outdoor exposures to trace elements in PM(2.5). Sci Total Environ 386:21–32

    Article  CAS  Google Scholar 

  • Anaf W, Horemans B, Madeira TI, Carvalho ML, De Wael K, Grieken RV (2013) Effects of a constructional intervention on airborne and deposited particulate matter in the Portuguese National Tile Museum, Lisbon. Environ Sci Pollut Res 20:1849–1857

    Article  CAS  Google Scholar 

  • Bornehag CG, Sundell J, Bonini S, Custovic A, Malmberg P, Skerfving S, Sigsgaard T, Verhoeff A, Euroexpo (2004) Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998–2000) on dampness and mite exposure in buildings and health effects. Indoor Air 14:243–257

    Article  CAS  Google Scholar 

  • Branis M, Rezacova P, Domasova M (2005) The effect of outdoor air and indoor human activity on mass concentrations of PM10, PM2.5, and PM1 in a classroom. Environ Res 99:143–149

    Article  CAS  Google Scholar 

  • Buonanno G, Marks GB, Morawska L (2013) Health effects of daily airborne particle dose in children: direct association between personal dose and respiratory health effects. Environ Pollut 180:246–250

    Article  CAS  Google Scholar 

  • Burge H (1990) Bioaerosols: prevalence and health effects in the indoor environment. J Allergy Clin Innunol 86:687–701

    Article  CAS  Google Scholar 

  • Chang T-J, Hsieh Y-F, Kao H-M (2006) Numerical invesstigation of airflow pattern and particulate matter transport in naturally ventilated multi-room buildings. Indoor Air 16:136–152

    Article  Google Scholar 

  • Chang FH, Li YY, Tsai CY, Yang CR (2009) Specific indoor environmental quality parameters in college computer classrooms. Int J Environ Res 3:517–524

    CAS  Google Scholar 

  • Chang T-J, Kao H-M, Hsieh Y-F (2012) Numerical study of the effect of ventilation pattern on coarse, fine, and very fine particulate matter removal in partitioned indoor environment. Air Waste Manag Assoc 57:179–189

    Article  Google Scholar 

  • Chen Y-C, Hsiao T-C (2015) Physiological responses to different CO2 levels in poor ventilation room, 6th European Conferencce of International Federation for Medical and Biological Engineering. IFMBE 45:423–426

    Article  Google Scholar 

  • Douwes J, Thorne P, Pearce N, Heederik D (2003) Bioaerosol health effects and exposure assessment: progress and prospects. Ann Occup Hyg 47:187–200

    Article  CAS  Google Scholar 

  • Duan F, He K, Ma Y, Jia Y, Yang F, Lei Y, Tanaka S, Okuta T (2005) Characteristics of carbonaceous aerosols in Beijing, China. Chemosphere 60:355–364

    Article  CAS  Google Scholar 

  • Emmerich SJ (2006) Simulated performance of natural and hybrid ventilation systems in an office building. HVAC Res 12:975–1004

  • Gao M, Qiu T, Jia R, Han M, Song Y, Wang X (2014) Concentration and size distribution of viable bioaerosols during non-haze and haze days in Beijing. Environ Sci Pollut Res 11:3675–3684

    Google Scholar 

  • Garcia-Aleix JR, Delgado-Saborit JM, Verdu-Martin G, Amigo-Descarrega JM, Esteve-Cano V (2014) Trends in arsenic levels in PM10 and PM 2.5 aerosol fractions in an industrialized area. Environ Sci Pollut Res Int 21:695–703

    Article  CAS  Google Scholar 

  • Godish T, Stpengler JD (1996) Relationships between ventilation and indoor air quality: a review. Indoor Air 6:135–145

    Article  Google Scholar 

  • Green F, Scarpino P, Gibbs S (2003) Assessment and modelling of indoor fungal and bacterial bioaerosol concentrations Aerobiologia. Aerobiologia 19:159–169

    Article  Google Scholar 

  • Griffiths W, Decosemo G (1994) The assessment of bioaerosols: a critical review. J Aerosol Sci 25:1425–1458

    Article  CAS  Google Scholar 

  • Guo H, Morawska L, He C, Zhang Y, Ayoko G, Cao M (2010) Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air. Environ Sci Pollut Res Int 17:1268–1278

    Article  CAS  Google Scholar 

  • Ha J, Jung H, Yoon CS, Oh I, Lee J, Kwon C (2011) Evaluation of atopy and its possible association with indoor bioaerosol concentrations and other factors at the residence of children. J Environ Health Sci 37:406–417

    Google Scholar 

  • Halek F, Keyanpour M, Pirmoradi A, Kavousi A (2010) Estimation of urban suspended particulate air pollution concentration. Int J Environ Res 4:161–168

    CAS  Google Scholar 

  • Hanley JT, Ensor DS, Smith DD, Sparks LE (1994) Fractional aerosol filtration efficiency of in-duct ventilation air cleaners. Indoor Air 4:169–178

    Article  CAS  Google Scholar 

  • Howard-Reed C, Wallace LA, Emmerisc SJ (2003) Effect of ventilation systems and air filters on decay rates of particles produced by indoor sources in and occupied townhouse. Atmos Environ 37:5295–5306

    Article  CAS  Google Scholar 

  • Jenkins P, Phillips T, Tulberg E, Hui S (1992) Activity patterns of Californians—use of and proximity to indoor pollutant sources. Atmos Environ 26:2141–2148

    Article  Google Scholar 

  • Jo WK, Seo YJ (2005) Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes. Chemosphere 61:1570–1579

    Article  CAS  Google Scholar 

  • Kim I-H, Kim KY, Kim D (2012) Characteristics of bioaerosol generation of household humidifiers by user practices. Korean J Environ Health Sci 38:503–509

    Article  CAS  Google Scholar 

  • Kim H-H, Lee C-S, Jeon J-M, Yu S-D, Lee C-W, Park J-H, Shin D-C, Lim Y-W (2013) Analysis of the association between air pollution and allergic diseases exposure from nearby sources of ambient air pollution within elementary school zones in four Korean cities. Environ Sci Pollut Res 20:4831–4846

    Article  CAS  Google Scholar 

  • Kuhlbusch T, John A, Quass U (2009) Sources and source contributions to fine particles Biomarkers 14

  • Lee BU, Yun SH, Jung JH, Bae G-N (2010) Effect of relative humidity and variation of particle number size distribution on the inactivation effectiveness of airborne silver nanoparticles against bacteria bioaerosols deposited on a filter. J Aerosol Sci 41:447–456

    Article  CAS  Google Scholar 

  • Luoma M, Batterman SA (2001) Characterization of particulate emissions from occupant activities in offices. Indoor Air 11:35–48

    Article  CAS  Google Scholar 

  • Marcazzan GM, Vaccano S, Vlli G, Vecchi R (2001) Characterisation of PM10 and PM2.5 particulate matter in the ambient air of Milan (Italy). Atmos Environ 35:4639–4650

    Article  CAS  Google Scholar 

  • Massey D, Masih J, Kulshrestha A, Habil M, Taneja A (2009) Indoor/outdoor relationship of fine particles less than 2.5μm (PM2.5) in residential homes locations in central Indian region. Build Environ 44:2037–2045

    Article  Google Scholar 

  • Maus R, Goppelsröder A, Umhauer H (1997) Viability of bacteria in unused air filter media. Atmos Environ 31:2305–2310

    Article  CAS  Google Scholar 

  • Morawska L (2010) Indoor air quality and health. Air Qual Clim Chang 44:12–14

    Google Scholar 

  • Mosley RB, Greenwell DJ, Sparks LE, Guo Z, Tucker WG, Fortmann R, Whitfield C (2001) Penetration of ambient fine particles into the indoor environment. Aerosol Sci Technol 34:127–136

    Article  CAS  Google Scholar 

  • Nevalainen A, Pastuszka J, Willeke K, Liebhaber F (1992) Performance of bioaerosol samplers: collection characteristics and sampler design considerations. Atmos Environ 26A:531–540

    Article  CAS  Google Scholar 

  • NIOSH iNIfOSaH (1998) Bioaerosol sampling (Indoor Air) METHOD: BIOAEROSOL SAMPLING (Indoor Air) Manual of Analytical Methods Fourth Edition

  • Novoselac A, Srebric J (2002) A critical review on the performance and design of combines cooled ceiling and displacement ventilation systems. Energy Build 34:497–509

    Article  Google Scholar 

  • Oh H-J, Nam I-S, Yun H, Kim J, Yang J, Sohn J-R (2014) Characterization of indoor air quality and efficiency of air purifier in childcare centers, Korea. Build Environ 82:203–214

    Article  Google Scholar 

  • Oosterlee A, Drijver M, Lebret E, Brunekreef B (1996) Chronic respiratory symptoms in children and adults living along streets with high traffic density. Occup Environ Med 53:241–247

    Article  CAS  Google Scholar 

  • Pekey B, Bozkurt Z, Pekey H, Dogan G, Zararsiz A, Efe N, Tuncel G (2010) Indoor/outdoor concentrations and elemental composition of PM10/PM2.5 in urban/industrial areas of Kocaeli City, Turkey. Indoor Air 20:112–125

    Article  CAS  Google Scholar 

  • Quang TN, He C, Morawska L, Knibbs LD (2013) Influence of ventilation and filtration on indoor particle concentrations in urban office buildings. Atmos Environ 79:41–52

    Article  CAS  Google Scholar 

  • Rai M, Gadgil AS, Ghole VS, Gore SD, Jaafarzadeh N, Golbabaei F (2007) Assessment of indoor airborne pollutants of beam rolling mills factory. Int J Environ Res 1:237–241

    Google Scholar 

  • Rafiq SK, Ganai BA, Bhat GA (2008) Impact of automobile emissions on the productivity of Crocus sativus L. Int J Environ Res 2:371–376

    Google Scholar 

  • Riley WJ, Mckone TE, Lai ACK, Nazaroff WW (2002) Indoor particulate matter of outdoor origin: important of size-dependent removal mechanisms. Environ Sci Technol 36:200–207

    Article  CAS  Google Scholar 

  • Robertson LD (1997) Monitoring viable fungal and bacterial bioaerosol concentrations to identify acceptable levels for common indoor environments. Indoor Built Environ 6:295–300

    Article  CAS  Google Scholar 

  • Rogula-Kozłowska W, Błaszczak B, Rogula-Kopiec P, Klejnowski K, Mathews B, Szopa S (2014) Physicochemical characteristics of fine ambient aerosol from quasi-rural area in Southern Poland. Int J Environ Res 8:751–764

    Google Scholar 

  • Rusca S, Charriere N, Droz PO, Oppliger A (2008) Effects of bioaerosol exposure on work-related symptoms among Swiss sawmill workers. Int Arch Occup Environ Health 81:415–421

    Article  CAS  Google Scholar 

  • Samet J, Spengler J (1991) Indoor air pollution—a health perspective. Johns Hopkins University Press, Baltimore

    Google Scholar 

  • Schwartz J, Neas L (2000) Fine particles are more strongly associated than coarse particles with acute respiratory health effects in schoolchildren. Epidemiology 11:6–10

    Article  CAS  Google Scholar 

  • Sillanpaa M, Hillamo R, Saarikoski S, Frey A, Pennanen A, Makkonen U, Spolnik Z, Van Grieken R, Branis M, Brunekreef B, Chalbot M-C, Kuhlbusch T, Sunyer J, Kerminen V-M, Kulmala M, Salonen RO (2006) Chemical composition and mass closure of particulate matter at six urban sites in Europe. Atmos Environ 40:212–223

    Article  Google Scholar 

  • Stackebrandt E, Rainet F, Ward-Rainey N (1997) Proposal for a new hierarchic classification system, Actinobacteria classis nov. J Bacteriol 47:479–491

    Google Scholar 

  • Stentzenbach L (1997) Introduction to aerobiology. In: Manual of environmenta; microbilogy Washington, DC, pp. 619–628

  • Sulejmanović J, Muhić-Šarac T, Memić M, Gambaro A, Selović A (2014) Trace metal concentrations in size-fractionated urban atmospheric particles of Sarajevo, Bosnia and Herzegovina. Int J Environ Res 8:711–718

    Google Scholar 

  • Sun Y, Zhuang G, Wang Y, Han L, Guo J, Dan M, Zhang W, Wang Z, Hao Z (2004) The air-borne particulate pollution in Beijing—concentration, composition, distribution and sources. Atmos Environ 38:5991–6004

    Article  CAS  Google Scholar 

  • Tina Z, Barbara J (2008) Assessment of bioaerosol concentrations in different indoor environments. Indoor Built Environ 17:155–163

    Article  Google Scholar 

  • Vecchi R, Marcazzan G, Valli G (2007) A study on nighttime–daytime PM10 concentration and elemental composition in relation to atmospheric dispersion in the urban area of Milan (Italy). Atmos Environ 41:2136–2144

    Article  CAS  Google Scholar 

  • Vette A, Rea A, Lawless P, Rodes C, Evans G, Highsmith V, Sheldon L (2001) Characterization of indoor-outdoor aerosol concentration relationships during the Fresno PM exposure studies. Aerosol Sci Technol 34:118–126

    Article  CAS  Google Scholar 

  • Wang X, Bi X, Sheng G, Fu J (2006) Hospital indoor PM10/PM2.5 and associated trace elements in Guangzhou, China. Sci Total Environ 366:124–135

    Article  CAS  Google Scholar 

  • Wargocki P, Wyon DP, Sundell J, Clausen G, Fanger PO (2000) The effects of outdoor air supply rate in an office on perceived air quality. Sick Building Syndrome (SBS) symptoms and productivity. Indoor Air 10:222–236

    Article  CAS  Google Scholar 

  • Yamamoto SS, Louis VR, Sié A, Sauerborn R (2014) Biomass smoke in Burkina Faso: what is the relationship between particulate matter, carbon monoxide, and kitchen characteristics? Environ Sci Pollut Res 21:2581–2591

    Article  CAS  Google Scholar 

  • Zorman T, Jersek B (2008) Assessment of bioaerosol concentrations in different indoor environments. Indoor Built Environ 17:155–163

    Article  Google Scholar 

Download references

Acknowledgments

This subject is supported by Korea Ministry of Environment as “Converging technology project (2013001650001)” and supported by Korea University Grant (K1508401).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jong-Ryeul Sohn.

Additional information

Responsible editor: Gerhard Lammel

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Oh, HJ., Jeong, NN., Chi, WB. et al. Characterization of particulate matter concentrations and bioaerosol on each floor at a building in Seoul, Korea. Environ Sci Pollut Res 22, 16040–16050 (2015). https://doi.org/10.1007/s11356-015-4810-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11356-015-4810-2

Keywords

Navigation