Objectives

In digital intraoral radiography (DIR), images with defects caused by the digital process are sometimes produced. Hence, we analyzed DIR images with defects taken using the photostimulable phosphor (PSP) plate method and then classified these images based on the causes of the defect. The aim of this study was to classify defects in DIR using the PSP plate system, and to discuss the causes of each type of defect and the methods that can prevent their occurrence.

Methods

Images with defects due to the two PSP plate systems (Arcana and Arcana Mira) were selected and classified according to the defect. Image defects caused by geometrical techniques that occur in both the film and PSP plate methods were excluded from this study. Moreover, changes in the rate of occurrence of images with defects over time were analyzed in this study.

Results

The defects in images obtained by the PSP plate system were classified into six types, which were further divided into those caused by machine error or human error. Both types of error could influence the diagnostic performance. Machine error accidentally and rarely occurred; thus, the prevention of such errors is difficult. However, human error, especially errors caused by photo-induced discharge, could be prevented using appropriate measures.

Conclusions

In DIR systems using the PSP plate method, human error should be prevented by education and training to improve operation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Mol A. Digital imaging. In: Mallya SM, Lam EWN, editors. White and Pharoah’s oral radiology principles and interpretation. 8th ed. St. Louis: Elsevier; 2019. p. 40–60.

    Google Scholar 

  2. Wenzel A, Møystad A. Work flow with digital intraoral radiography: a systematic review. Acta Odontol Scand. 2010. https://doi.org/10.3109/00016350903514426.

    Article  PubMed  Google Scholar 

  3. Yaffe MJ, Rowlands JA. X-ray detectors for digital radiography. Phys Med Biol. 1997. https://doi.org/10.1088/0031-9155/42/1/001.

    Article  PubMed  Google Scholar 

  4. Seibert JA, Bogucki TM, Ciona T, Huda W, Karellas A, Mercier JR, Samei E, Shepard SJ, Stewart BK, Strauss KJ, Suleiman OH, et al. Acceptance testing and quality control of photostimulable storage phosphor imaging systems. Rpt. of AAPM Task Group. 2006;10.

  5. Freedman M, Steller D, Jafroudi H, Mun SK. Quality control of storage phosphor digital radiography systems. J Digit Imaging. 1995. https://doi.org/10.1259/dmfr/91373164.

    Article  PubMed  Google Scholar 

  6. Ramamurthy R, Canning CF, Scheetz JP, Farman AG. Impact of ambient lighting intensity and duration on the signal-to-noise ratio of images from photostimulable phosphor plates processed using DenOptix and ScanX systems. Dentomaxillofac Radiol. 2004. https://doi.org/10.1259/dmfr/91373164.

    Article  PubMed  Google Scholar 

  7. Chiu HL, Lin SH, Chen CH, Wang WC, Chen JY, Chen YK, et al. Analysis of photostimulable phosphor plate image artifacts in an oral and maxillofacial radiology department. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008. https://doi.org/10.1016/j.tripleo.2008.01.003.

    Article  PubMed  Google Scholar 

  8. Gulsahi A, Secgin CK. Assessment of intraoral image artifacts related to photostimulable phosphor plates in a dentomaxillofacial radiology department. Niger J Clin Pract. 2016. https://doi.org/10.4103/1119-3077.164338.

    Article  PubMed  Google Scholar 

  9. Çalışkan A, Sumer AP. Definition, classification and retrospective analysis of photostimulable phosphor image artefacts and errors in intraoral dental radiography. Dentomaxillofac Radiol. 2017. https://doi.org/10.1259/dmfr.20160188.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Deniz Y, Kaya S. Determination and classification of intraoral phosphor storage plate artifacts and errors. Imaging Sci Dent. 2019. https://doi.org/10.5624/isd.2019.49.3.219.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Pamukcu U, Tetik H, Peker I, Atas OK, Akarslan ZZ. Effect of enveloping and disinfection methods on artefact formation on enveloped PSP plate images. Oral Radiol. 2022. https://doi.org/10.1007/s11282-022-00587-1.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Elkhateeb SM, Aloyouny AY, Omer MMS, Mansour SM. Analysis of photostimulable phosphor image plate artifacts and their prevalence. J Clin Cases. 2022. https://doi.org/10.12998/wjcc.v10.i2.437.

    Article  Google Scholar 

Download references

Acknowledgements

We thank Kimberly Moravec, PhD, from Edanz (https://jp.edanz.com/ac) for editing a draft of this manuscript.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Eiji Nakayama.

Ethics declarations

Conflict of interest

There are no financial or other relations that could lead to a conflict of interest.

Ethics approval

This article was exempt from ethical approval by our institution because all identifiable patient information has been removed from the data.

Informed consent

The informed consent was determined to be unnecessary by our regulations as no identifiable patient information is present in the paper.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tashiro, M., Nakatani, A., Sugiura, K. et al. Analysis of image defects in digital intraoral radiography based on photostimulable phosphor plates. Oral Radiol 39, 355–363 (2023). https://doi.org/10.1007/s11282-022-00645-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11282-022-00645-8

Keywords

Navigation