Vacuum large-aperture black body model in the temperature range of 223.15–423.15 K for radiometric calibration of optoelectronic equipment for earth observations

  • THERMOPHYSICAL MEASUREMENTS
  • Published:
Measurement Techniques Aims and scope

Abstract

The article presents the structure of systems for radiometric calibration for the Earth remote sensing optoelectronic equipment in the infrared spectrum range. Analysis of existing facilities for radiometric calibration of the Earth remote sensing optoelectronic equipment in conditions of vacuum and low-background radiation was carried out. These facilities are based on using the black body models as radiation sources, including reference sources based on the phase transition of pure metals, for example gallium or indium. A large-aperture black body model LABB-380 with an aperture diameter of 380 mm in the temperature range of 223.15–423.15 K has been developed. LABB-380 is part of a high-vacuum low-background test rig currently being developed at the Scientific Research Institute of Optoelectronic Instrumentation for the radiometric calibration of the Earth remote sensing optoelectronic equipment. The results of calculating the normal effective emissivity of the LABB-380 surface in the above temperature range and the spectral range of 3–20 μm are presented. The metrological characteristics of LABB-380 obtained during the transmission of a temperature unit from the State Working Standard of the zero category of a temperature unit in the range from 0 to 3000 °C (Registration No. 3.1.ZZA.0020.2015) using a comparator based on the HETRONIXS precision pyrometer have been studied. According to the calibration results in the temperature range of 300.15–390.15 K, the instability of the LABB-380 radiation was 0.005 K, the extended temperature uncertainty was 0.66 K at the temperature of 300.15 K and 0.88 K at 390.15 K.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Sapritsky, V.I., Krutikov, V.N., Ivanov, V.S.: Current activity of Russia in measurement assurance of Earth optical observations. Metrologia 49(2), 9 (2012)

    Article  Google Scholar 

  2. Ivanov, V.S., Lisiansky, B.E., Morozova, S.P.: Medium-background radiometric facility for calibration of sources or sensors. Metrologia 37(5), 599–602 (2000)

    Article  ADS  Google Scholar 

  3. S. P. Morozova, V. I. Sapritsky, V. S. Ivanov, et al., “Facility for blackbody calibration,” in: Proceedings of the 7th International Symposium on Temperature and Thermal Measurements in Industry and Science, Edauw & Johannissen B.V., Delft (1999).

  4. Morozova, S.P., Parfentiev, N.A., Lisiansky, B.E.: Vacuum variable-temperature blackbody VTBB100. Int J Thermophys 29, 341–351 (2008)

    Article  CAS  ADS  Google Scholar 

  5. Monte, C., Gutschwager, B., Morozova, S.P., Hollandt, J.: Radiation thermometry and emissivity measurements under vacuum at the PTB. Int J Thermophys 30, 203–219 (2009)

    Article  CAS  ADS  Google Scholar 

  6. Morozova, S.P., Parfentiev, N.A., Lisiansky, B.E.: Vacuum variable medium temperature blackbody. Int J Thermophys 31, 1809–1820 (2010)

    Article  CAS  ADS  Google Scholar 

  7. Zhou, J., Hao, X., Song, J.: Stray light separation based on the changeable veiling glare index for the vacuum radiance temperature standard facility. Opt. Express 29(8), 12344–12356 (2021)

    Article  PubMed  ADS  Google Scholar 

  8. Morozova, S.P., Katysheva, A.A., Panfilov, A.S.: Preflight spectral radiance infrared calibration facility. Int J Thermophys 35, 1330–1340 (2014)

    Article  CAS  ADS  Google Scholar 

  9. S. P. Morozova, V. I. Sapritskiy, V. R. Gavrilov, et al., “Methods and means of pre-flight radiometric calibration of the Earth remote sensing optoelectronic equipment in the infrared spectrum range,” in: Proceeding of the XVII Scientific and Technical Conference “Systems of Observation, Monitoring and Earth Remote Sensing,” Manuscript Publ., Kaluga (2021).

  10. Sapritsky, V.I., Prokhorov, A.V.: Calculation of the effective emissivities of specular-diffuse cavities by the Monte Carlo method. Metrologia 29(1), 9–14 (1992)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. L. Dovgilov.

Ethics declarations

Conflict of interest

The authors declare no conflict of interest.

Additional information

Translated from Izmeritel’naya Tekhnika, Vol. 66, No. 8, pp. 60–66, August, 2023. https://doi.org/10.32446/0368-1025it.2023-8-60-66

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Original article submitted on July 12, 2023. Accepted on July 14, 2023.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Dovgilov, N.L., Morozova, S.P., Alekseev, S.V. et al. Vacuum large-aperture black body model in the temperature range of 223.15–423.15 K for radiometric calibration of optoelectronic equipment for earth observations. Meas Tech 66, 619–627 (2023). https://doi.org/10.1007/s11018-023-02274-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11018-023-02274-x

Keywords

UDC

Navigation