Development of Compact Dry 3He-4He Dilution Refrigerator for Transition Edge Sensor Microcalorimeter X-ray Detector Operation on Electron Microscopes

  • Original Paper
  • Published:
Journal of Superconductivity and Novel Magnetism Aims and scope Submit manuscript

Abstract

A compact dry 3He- 4He dilution refrigerator (DR) was developed for operation of a superconducting transition edge sensor (TES) microcalorimeter x-ray detector mounted on a transmission electron microscope. A Gifford-McMahon (GM)-type mechanical cryocooler was used as a DR pre-cooler to operate the TES microcalorimeter without consuming liquid helium. To reduce the noise and vibrations generated by the GM cryocooler, the DR was separated from the cryocooler in a split system that allows a remote helium cooling loop to pre-cool the DR. In the DR unit, the dilution components of the still, the heat exchangers, and the cascade pair of mixing chambers were assembled into a compact cylinder. A snout made from an oxygen-free copper rod was attached to the DR mixing chamber for placement of the TES microcalorimeter x-ray detector. The lowest temperature and the cooling power in the mixing chamber were measured to be 87 mK and 20 μW at 100 mK, respectively. The DR unit was shown to maintain the temperature on top of the snout such that it was below the temperature required for multi-pixel-array TES microcalorimeter x-ray detector operation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Goldstein, J., Newbury, D., Joy, D., Lyman, C., Echlin, P., Lifshin, E., Sawyer, L., Michael, J.: Scanning electron microscopy and x-ray microanalysis, 3rd edn., pp. 314–316. Springer, New York (2003)

    Book  Google Scholar 

  2. Angloher, G.: Low-temperature detectors. Nucl. Instru. Meth., A512 (2003)

  3. Hara, T., Tanaka, K., Maehata, K., Mitsuda, K., Yamasaki, N. Y., Ohsaki, M., Watanabe, K., Yu, X., Ito, T., Yamanaka, Y.: Microcalorimeter-type energy dispersive x-ray spectrometer for a transmission electron microscope. J. Electron. Microsc. 59, 17–26 (2010)

    Article  Google Scholar 

  4. Maehata, K., Hara, T., Ito, T., Yamanaka, Y., Tanaka, K., Mitsuda, K., Yamasaki, N.Y.: A dry 3He- 4 dilution refrigerator for a transition edge sensor microcalorimeter spectrometer system mounted on a transmission electron microscope. Cryogenics 61, 86–91 (2014)

    Article  ADS  Google Scholar 

  5. Coops, G. M., de Waele, A Th. A. M., Gijsman, H. M.: The multiple mixing chamber. Cryogenics 19, 659–665 (1979)

    Article  ADS  Google Scholar 

  6. Nagayoshi, K., Ssakai, K., Mitsuda, K., Yamasaki, N.Y., Takei, Y., Maehata, K., Iyomoto, N., Ezaki, S., Takano, A., Maeda, M., Hara, T.: Three-dimensionally assembled TES x-ray microcalorimater arrays for a TEM EDS system, submitted to IEICE TRANS

Download references

Acknowledgments

This work was financially supported by SENTAN, Japan Science and Technology Agency (JST).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. Maehata.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Maehata, K., Iyomoto, N., Yamanaka, Y. et al. Development of Compact Dry 3He-4He Dilution Refrigerator for Transition Edge Sensor Microcalorimeter X-ray Detector Operation on Electron Microscopes. J Supercond Nov Magn 28, 1161–1165 (2015). https://doi.org/10.1007/s10948-014-2699-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10948-014-2699-5

Keywords

Navigation