Development of Gamma-Ray Transition-Edge-Sensor Microcalorimeters on Thick Membranes

  • Published:
Journal of Low Temperature Physics Aims and scope Submit manuscript

Abstract

We developed transition-edge-sensor microcalorimeters to detect gamma rays of energy up to a few MeV. To develop devices that have mechanical robustness and fast response together with reasonable thermal isolation, we fabricated devices with thick (17 μm or 9.5 μm) membranes using silicon-on-insulator wafers. Here, we report the results for one of each device. The thermal conductances of the 17-μm-thick-membrane device and the 9.5-μm-thick-membrane device were measured to be 84 nW/K and 52 nW/K at their transition temperatures of 162 mK and 202 mK, respectively. The thermal conductances are 20–30 times and 6–9 times larger than those of our thin-membrane devices, when compared at the same temperatures. We irradiated the devices with gamma rays from a Cs-137 source. About 30% of the accumulated pulses are signals from the absorbers, while the remaining are signals from the silicon substrates. The energy resolution of the 662-keV photo peak for the 17-μm-thick-membrane device is 2.2 keV, whereas the baseline energy resolution is 2.3 keV. The energy resolution is several times worse than the design value. One reason for the degradation of the energy resolution is the low-frequency noise of the mechanical cooler, and the other reason is the thermal noise arising from the Compton-scattering events in the substrate.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. K.D. Irwin, G.C. Hilton, Cryogen particle detection, in Topics in Applied Physics, vol. 99, ed. by C. Enss (Springer, Berlin, 2005)

    Google Scholar 

  2. N. Iyomoto, H. Kawakami, K. Maehata et al., J. Low Temp. Phys. 184, 82 (2016)

    Article  ADS  Google Scholar 

  3. E. Figueroa-Feliciano, Nucl. Instr. Meth. A 520, 496 (2004)

    Article  ADS  Google Scholar 

  4. N. Iyomoto, S.R. Bandler, R.P. Brekosky et al., Nucl. Instr. Meth. A 559, 491 (2006)

    Article  ADS  Google Scholar 

Download references

Acknowledgements

This work was supported by JSPS KAKENHI Grant Number JP17H03523.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Naoko Iyomoto.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Iyomoto, N., Yoshimine, I., Shuto, Y. et al. Development of Gamma-Ray Transition-Edge-Sensor Microcalorimeters on Thick Membranes. J Low Temp Phys 194, 412–417 (2019). https://doi.org/10.1007/s10909-018-2100-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10909-018-2100-3

Keywords

Navigation