Abstract
Early detection of accidental endobronchial intubation (EBI) is still an unsolved problem in anesthesia and critical care daily practice. The aim of this study was to evaluate the ability of monitoring above cuff CO2 to detect EBI (the working hypothesis was that the origin of CO2 is from the unventilated, but still perfused, lung). Six goats were intubated under general anesthesia and the ETT positioning was verified by a flexible bronchoscope. The AnapnoGuard system, already successfully used to detect air leak around the ETT cuff, was used for continuous monitoring of above-the-cuff CO2 level. When the ETT distal tip was located in the trachea, with an average cuff pressure of 15 mmHg, absence of CO2 above the cuff was observed. The ETT was then deliberately advanced into one of the main bronchi under flexible bronchoscopic vision. In all six cases the immediate presence of CO2 above the cuff was identified. Further automatic inflation of the cuff, up to a level of 27 mmHg, did not affect the above-the-cuff measured CO2 level. Withdrawal of the ETT and repositioning of its distal tip in mid-trachea caused the disappearance of CO2 above the cuff in a maximum of 3 min, confirming the absence of air leak and the correct positioning of the ETT. Our results suggest that measurement of the above-the-cuff CO2 level could offer a reliable, on-line solution for early identification of accidental EBI. Further studies are planned to validate the efficacy of the method in a clinical setup.
Similar content being viewed by others
References
Szekely SM, Webb RK, Williamson JA, Russell WJ. Problems related to the endotracheal tube. Anaesth Intensiv Care. 1992;21:611–6.
McCoy EP, Russell WJ, Webb RK. Accidental bronchial intubation. An analysis of AIMS incidents report from, 1988 to 1994 inclusive. Anaesthesia. 1997;52:24–31.
Owen TR, Cheney FW. Endobronchial intubation: a preventable complication. Anesthesiology. 1987;67:255–7.
Dornette WHL. Anatomy for the anesthesiologist. Springfield: Charles C. Thomas; 1963. p. 973–7.
Brunel W, Coleman DL, Schwartz DE, Peper E, Cohen NH. Assessment of routine chest roentgenograms and physical examination to confirm endotracheal tube position. Chest. 1989;96:1043–5.
Sitzwohl C, Langheinrich A, Schober A, Krafft P, Sessler DI, Herkner H, Gonano C, Weinstabl C, Kettner SC. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial. BMJ. 2010;341:c5943.
Efrati S, Deutsch I, Gurman GM. Endotracheal tube cuff–small important part of a big issue. J Clin Monit Comput. 2012;26:53–60.
Alliaume B, Coddens J, Deloof T. Reliability of auscultation in positioning of double lumen endobronchial tube. Can J Anaesth. 1992;39:687–90.
Barker SJ, Tremper KK, Hyatt J, Heitzman H. Comparison of three oxygen monitors in detecting endobronchial intubation. J Clin Monit. 1988;4:240–3.
Johnson DH, Chang PC, Hurst TS, Reynolds FB, Lang SA, Mayers I. Changes in PETCO2 and pulmonary blood flow after bronchial occlusion in dogs. Can J Anaesth. 1992;39:184–91.
Heaneghan CPH, Scallan MJ, Branthwaite MA. End-tidal carbon dioxide during thoracotomy. Anaesthesia. 1981;36:1017–21.
Conrardy PA, Goodman LR, Lainge F, Singer MM. Alteration of endotracheal tube position. Flexion and extension of the neck. Crit Care Med. 1976;4:7–12.
Efrati S, Leonov Y, Oron A, Siman-Tov Y, Averbukh M, Lavrushevich A, Golik A. Optimization of endotracheal tube cuff filling by continuous upper airway carbon dioxide monitoring. Anesth Analg. 2005;101:1081–8.
Suggett AJ, Barer GR, Mohammed FH, Gill GW. The effects of localized hypoventilation on ventilation/perfusion (V/Q) ratios and gas exchange in the dog lung. Clin Sci. 1982;63:497–503.
Ezri T, Khazin V, Szmuk P, Medalion B, Shechter P, Priel I, Loberboim M, Weibroum AA. Use of the Rapiscope vs chest auscultation for detection of accidental bronchial intubation in non-obese patients undergoing laparoscopic cholecystectomy. J Clin Anesth. 2006;18:118–23.
Raphael DT, Benbassat M, Arnaudov D, Bohorquez A, Nasseri B. Validation study of two-microphone acoustic reflectometry for determination of breathing tube placement in 200 adult patients. Anesthesiology. 2002;97:1371–7.
Jean S, Cinel I, Gratz I, Tay C, Lotano V, Deal E, Parillo JE, Dellinger RP. Image-based monitoring of one-lung intubation. Eur J Anaesthesiol. 2008;25:995–1001.
Tejman-Yarden S, Lederman D, Eilig I, Zlotnik A, Weksler N, Cohen A, Gurman GM. Acoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation. Anesth Analg. 2006;103:1489–93.
Tejman-Yarden S, Zlotnik A, Weizman L, Tabrikian J, Cohen A, Weksler N, Gurman GM. Acoustic monitoring of lung sounds for the detection of one-lung intubation. Anesth Analg. 2007;105:397–404.
Efrati S, Deutsch I, Gurman GM, Noff M, Conti G. Tracheal pressure and endotracheal tube obstruction can be detected by continuous cuff pressure monitoring: in vitro pilot study. Intensive Care Med. 2010;36:984–90.
Acknowledgments
The study was supported by Hospitech Respiration, Ltd.
Conflict of interest
SE and ID are shareholders in Hospitech Respiration, Ltd.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Efrati, S., Deutsch, I., Weksler, N. et al. Detection of endobronchial intubation by monitoring the CO2 level above the endotracheal cuff. J Clin Monit Comput 29, 19–23 (2015). https://doi.org/10.1007/s10877-014-9583-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10877-014-9583-5