Skip to main content
Log in

Pulmonary vein anatomy assessed by cardiac magnetic resonance imaging in patients undergoing initial atrial fibrillation ablation: implications for novel ablation technologies

  • Published:
Journal of Interventional Cardiac Electrophysiology Aims and scope Submit manuscript

Abstract

Background

Novel atrial fibrillation (AF) ablation tools have been designed to facilitate “single-shot” pulmonary vein (PV) isolation using multi-electrode or balloon-based catheters. However, in contrast to point-by-point radiofrequency ablation, these tools may be more dependent on suitable PV anatomy to achieve circumferential PV isolation.

Methods

Three hundred and twenty-two patients underwent gadolinium-enhanced cardiac magnetic resonance angiography to delineate PV anatomy prior to initial AF ablation. Long (a) and short (b) axis measurements of the PV orifice were used to calculate the eccentricity index of the PV ostium.

Results

Long axis dimensions of the left superior PV were 18.2 ± 3.3 mm, left inferior PV 17.7 ± 3.9 mm, right superior PV (RSPV) 20.4 ± 4.3, and right inferior PV 18.7 ± 4.7 mm. The long axis dimension of the RSPV was significantly larger than other PVs (p < 0.001). Forty-two patients (13 %) had at least one PV with a long axis dimension >25 mm and 16 patients (5 %) had at least one PV with a long axis dimension >28 mm. Left-sided PV ostia were significantly more ellipse-shaped than the right-sided PVs, which tended to be more spherical. A significant positive correlation was noted between increasing PV size and increased orifice eccentricity.

Conclusions

In this large cohort undergoing initial AF ablation, over 10 % of patients had at least one standard PV with a dimension >25 mm. Additionally, significant differences were noted between left- and right-sided veins with regard to orifice eccentricity. These findings have implications for the design of AF ablation tools and may account for differential isolation rates between PVs noted in some recent studies of novel ablation technologies.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2010). Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 3(1), 32–38.

    Article  PubMed  Google Scholar 

  2. Hummel, J., Michaud, G., Hoyt, R., DeLurgio, D., Rasekh, A., Kusumoto, F., et al. (2014). Phased RF ablation in persistent atrial fibrillation. Heart Rhythm, 11(2), 202–209.

    Article  PubMed  Google Scholar 

  3. Zellerhoff, S., Daly, M., Lim, H. S., Denis, A., Komatsu, Y., Jesel, L., et al. (2014). Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacy. Europace, 16(9), 1296–1303.

    Article  PubMed  Google Scholar 

  4. Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., et al. (2013). Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. Journal of the American College of Cardiology, 61(16), 1713–1723.

    Article  PubMed  Google Scholar 

  5. Dukkipati, S. R., Woollett, I., Mc, E. H., Bohmer, M. C., Doshi, S. K., Gerstenfeld, E. P., et al. (2015). Pulmonary Vein Isolation Using the Visually Guided Laser Balloon: Results of the U.S. Feasibility Study. J Cardiovasc Electrophysiol, doi:10.1111/jce.12727

  6. McLellan, A. J., Ling, L. H., Ruggiero, D., Wong, M. C., Walters, T. E., Nisbet, A., et al. (2014). Pulmonary vein isolation: the impact of pulmonary venous anatomy on long-term outcome of catheter ablation for paroxysmal atrial fibrillation. Heart Rhythm, 11(4), 549–556.

    Article  PubMed  Google Scholar 

  7. van der Voort, P. H., van den Bosch, H., Post, J. C., & Meijer, A. (2006). Determination of the spatial orientation and shape of pulmonary vein ostia by contrast-enhanced magnetic resonance angiography. Europace, 8(1), 1–6.

    Article  PubMed  Google Scholar 

  8. Thorning, C., Hamady, M., Liaw, J. V., Juli, C., Lim, P. B., Dhawan, R., et al. (2011). CT evaluation of pulmonary venous anatomy variation in patients undergoing catheter ablation for atrial fibrillation. Clinical Imaging, 35(1), 1–9.

    Article  PubMed  Google Scholar 

  9. Mlcochova, H., Tintera, J., Porod, V., Peichl, P., Cihak, R., & Kautzner, J. (2005). Magnetic resonance angiography of pulmonary veins: implications for catheter ablation of atrial fibrillation. Pacing and Clinical Electrophysiology, 28(10), 1073–1080.

    Article  PubMed  Google Scholar 

  10. Mansour, M., Holmvang, G., Sosnovik, D., Migrino, R., Abbara, S., Ruskin, J., et al. (2004). Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 15(4), 387–393.

    Article  PubMed  Google Scholar 

  11. Scharf, C., Sneider, M., Case, I., Chugh, A., Lai, S. W., Pelosi, F., Jr., et al. (2003). Anatomy of the pulmonary veins in patients with atrial fibrillation and effects of segmental ostial ablation analyzed by computed tomography. Journal of Cardiovascular Electrophysiology, 14(2), 150–155.

    Article  PubMed  Google Scholar 

  12. Ahmed, J., Sohal, S., Malchano, Z. J., Holmvang, G., Ruskin, J. N., & Reddy, V. Y. (2006). Three-dimensional analysis of pulmonary venous ostial and antral anatomy: implications for balloon catheter-based pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 17(3), 251–255.

    Article  PubMed  Google Scholar 

  13. Merchant, F. M., & Delurgio, D. B. (2014). Catheter ablation of atrial fibrillation and risk of asymptomatic cerebral embolism. Pacing and Clinical Electrophysiology, 37(3), 389–397.

    Article  PubMed  Google Scholar 

  14. Tsyganov, A., Petru, J., Skoda, J., Sediva, L., Hala, P., Weichet, J., et al. (2015). Anatomical predictors for successful pulmonary vein isolation using balloon-based technologies in atrial fibrillation. J Interv Card Electrophysiol, doi:10.1007/s10840-015-0068-3

  15. Brunelli, M., Raffa, S., Grosse, A., Wauters, K., Menoni, S., Schreiber, M., et al. (2012). Influence of the anatomic characteristics of the pulmonary vein ostium, the learning curve, and the use of a steerable sheath on success of pulmonary vein isolation with a novel multielectrode ablation catheter. Europace, 14(3), 331–340.

    Article  PubMed  Google Scholar 

  16. Guler, E., Guler, G. B., Demir, G. G., Kizilirmak, F., Gunes, H. M., Barutcu, I., et al. (2015). Effect of pulmonary vein anatomy and pulmonary vein diameters on outcome of cryoballoon catheter ablation for atrial fibrillation. Pacing and Clinical Electrophysiology, 38(8), 989–996.

    Article  PubMed  Google Scholar 

  17. Heeger, C. H., Wissner, E., Mathew, S., Deiss, S., Lemes, C., Rillig, A., et al. (2015). Once isolated, always isolated? Incidence and characteristics of pulmonary vein reconduction after second-generation cryoballoon-based pulmonary vein isolation. Circulation. Arrhythmia and Electrophysiology, 8(5), 1088–1094.

    Article  PubMed  Google Scholar 

  18. Andrade, J. G., Khairy, P., Macle, L., Packer, D. L., Lehmann, J. W., Holcomb, R. G., et al. (2014). Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial. Circulation. Arrhythmia and Electrophysiology, 7(1), 69–75.

    Article  PubMed  Google Scholar 

  19. Metzner, A., Kivelitz, D., Schmidt, B., Fuernkranz, A., Wissner, E., Tilz, R. R., et al. (2012). Impact of pulmonary vein anatomy assessed by cardiac magnetic resonance imaging on endoscopic pulmonary vein isolation in consecutive patients. Europace, 14(4), 474–480.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Faisal M. Merchant.

Ethics declarations

None

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Merchant, F.M., Levy, M.R., Iravanian, S. et al. Pulmonary vein anatomy assessed by cardiac magnetic resonance imaging in patients undergoing initial atrial fibrillation ablation: implications for novel ablation technologies. J Interv Card Electrophysiol 46, 89–96 (2016). https://doi.org/10.1007/s10840-016-0106-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10840-016-0106-9

Keywords

Navigation