Skip to main content
Log in

Ensuring Correct Functioning of Remote Protection of a Power Line Under Conditions of Saturation of Current Transformers

  • Published:
Power Technology and Engineering Aims and scope

The results of studying the effect of saturation of class P current transformers (CT) in transient modes for actuating the impedance relay of the first stages of remote protection against single-phase short circuits are presented. Various connection configurations of the CT to the resistance relay are examined. Methods of increasing the selectivity and speed of action of the specified protections in the modes under study are substantiated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. State Standard GOST 7746–2015. Current transformers. General specifications [in Russian].

  2. A. D. Drozdov, Circuits with Ferromagnetic Cores in Relay Protection [in Russian], Énergiya, Moscow (1965).

    Google Scholar 

  3. S. L. Kuzhekov, A. A. Degtyarev, V. S. Vorob’ev, and V. V. Moskalenko, “Determining time before saturation of current transformers in transient modes of short circuits,” Élektr. Stantsii, No. 1, 42 – 47 (2017).

  4. A. M. Fedoseev and M. A. Fedoseev, Relay Protection of Electropower Systems: Textbook for Higher Education Institutions. 2nd Edition [in Russian], Énergoatomizdat, 1992.

  5. Multilin Power Management Lentronics. CT requirements for GE Multilin relays (R 2) [on-line]: https://ru.scribd.com/doc/47176650/CT-Selection-requirements.

  6. S. L. Kuzhekov and G. S. Nudel’man, “Ensuring proper actuation of differential-protection microprocessor devices during current transformer saturation,” Izv. Vuzov. Élektromekh., No. 4, 7 – 11 (2009).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. L. Kuzhekov.

Additional information

Translated from Élektricheskie Stantsii, No. 6, June 2017, pp. 46 – 53.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kuzhekov, S.L., Degtyarev, A.A., Vorob’ev, V.S. et al. Ensuring Correct Functioning of Remote Protection of a Power Line Under Conditions of Saturation of Current Transformers. Power Technol Eng 51, 481–488 (2017). https://doi.org/10.1007/s10749-017-0860-6

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-017-0860-6

Keywords

Navigation