Assessment of physicochemical parameters and prevalence of virulent and multiple-antibiotic-resistant Escherichia coli in treated effluent of two wastewater treatment plants and receiving aquatic milieu in Durban, South Africa

  • Published:
Environmental Monitoring and Assessment Aims and scope Submit manuscript

Abstract

The poor operational status of some wastewater treatment plants often result in the discharge of inadequately treated effluent into receiving surface waters. This is of significant public health concern as there are many informal settlement dwellers (ISDs) that rely on these surface waters for their domestic use. This study investigated the treatment efficiency of two independent wastewater treatment plants (WWTPs) in Durban, South Africa and determined the impact of treated effluent discharge on the physicochemical and microbial quality of the receiving water bodies over a 6-month period. Presumptive Escherichia coli isolates were identified using biochemical tests and detection of the mdh gene via PCR. Six major virulence genes namely eae, hly, fliC, stx1, stx2, and rfbE were also detected via PCR while antibiotic resistance profiles of the isolates were determined using Kirby-Bauer disc diffusion assay. The physicochemical parameters of the wastewater samples ranged variously between 9 and 313.33 mg/L, 1.52 and 76.43 NTUs, and 6.30 and 7.87 for COD, turbidity, and pH respectively, while the E. coli counts ranged between 0 and 31.2 × 103 CFU/ml. Of the 200 selected E. coli isolates, the hly gene was found in 28 %, fliC in 20 %, stx2 in 17 %, eae in 14 %, with stx1 and rfbE in only 4 % of the isolates. Notable resistance was observed toward trimethoprim (97 %), tetracycline (56 %), and ampicillin (52.5 %). These results further highlight the poor operational status of these WWTPs and outline the need for improved water quality monitoring and enforcement of stringent guidelines.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  • Adewumi, J. R., Illemobade, A. A., & Van Zyl, J. E. (2010). Treated wastewater reuse in South Africa: overview, potential and challenges. Resources, Cconservation and Recycling, 55, 221–231.

    Article  Google Scholar 

  • Akiyama, T., & Savin, M. C. (2010). Populations of antibiotic-resistant coliform bacteria change rapidly in a wastewater effluent dominated stream. Science of the Total Environment, 408, 6192–6201.

    Article  CAS  Google Scholar 

  • Bai, J., Shi, X., & Nagaraja, T. G. (2010). A multiplex pcr procedure for the detection of six major virulence genes in Escherichia coli O157:H7. Journal of Microbioogical Methods, 82, 85–89.

    Article  CAS  Google Scholar 

  • Beutin, L., Geier, D., Steinruck, H., Zimmerman, S., & Scheutz, F. (1993). Prevalence and some properties of vertotoxin (Shiga-like toxin)-producing Escherichia coli in seven different species of healthy domestic animals. Journal of Clinical Microbiology, 31, 2483–2488.

    CAS  Google Scholar 

  • Bezirtzoglou, E., Panagiou, A., Savvaidis, I., & Maipa, V. (1997). Distribution of C. perfringens in polluted lake environments. Anaerobe, 3, 172–96.

    Google Scholar 

  • Blom, A., Harder, W., & Matin, A. (1992). Unique and overlapping pollutant stress proteins of Escherichia coli. Applied and Environmental Microbiology, 58, 331–334.

    CAS  Google Scholar 

  • Chapman, D. (1996) Water quality assessments: a guide to the use of biota, sediments and water in environmental monitoring. http://www.who.int/water_sanitation_health/resourcesquality/wqachapter2. pdf?ua = 1. Accessed 12 June 2014.

  • Cherchi, C., & Gu, A. Z. (2011). Effect of bacterial growth stage on resistance to chlorine disinfection. Water Science and Technology, 64, 7–13.

    Article  CAS  Google Scholar 

  • Clesceri, L. S., Greenberg, A. E., & Eaton, A. D. (1998). Standard methods for the examination of water and wastewater (centennialth ed.). Washington: American Public Health Association.

    Google Scholar 

  • Clinical and Laboratory Standards Institute (2013) Performance standards for antimicrobial susceptibility testing; twenty-third informational supplement. https://antimicrobianos.com.ar/ATB/wp-content/uploads/…/M100S22E.pdf. Accessed 5 April 2014.

  • Department of Water Affairs and Forestry. (1996). South African water quality guidelines for domestic use (2nd ed., pp. 1–185). Durban: Department of Water Affairs and Forestry.

    Google Scholar 

  • Department of Water and Environmental Affairs (1984) Republic of South Africa, Government Gazette, requirements for the purification of wastewater or effluent: general and special standards, regulation no. 91. Department of Water and Environmental Affairs, republic of South Africa, Durban, 1984. https://www.dwaf.gov.za/Dir_WQM/docs/Leg_General%20and%20Special%20Standards.doc. Accessed 20 July 2012.

  • Doyle, M.P., Zhao, T., Meng, J., Zhao, S. (1997) Escherichia coli 0157:H7. In M.P. Doyle, L. R. Beuchat, T. J. Montbille (Ed.), Food Microbiology- Fundamentals and Frontiers (pp. 171 – 191). American Society of Microbiology Press.

  • DWAF, quality of domestic water supplies. Sampling guide 2, Department of Water Affairs and Forestry, Department of Health and Water Research Commission, 1999.

  • Edberg, S. C. (2009). Does the possession of virulence factor genes mean that those genes will be active? Journal of Water and Health, 7, 19–28.

    Article  Google Scholar 

  • Fatoki, S. O., Muyima, N. Y. O., & Lujiza, N. (2001). Situation analysis of water quality in the Umtata River catchment. Water SA, 27, 467–474.

    Article  CAS  Google Scholar 

  • Goni-Urriza, M., Capdepuy, M., Arpin, C., Raymond, N., Caumette, P., & Quentin, C. (2000). Impact of urban effluent on antibiotic resistance of riverine Enterobacteriaceae and Aeromonas spp. Applied and Environmental Microbiology, 66, 125–132.

    Article  CAS  Google Scholar 

  • Govender, T., Barnes, J. M., & Pieper, C. H. (2011). Contribution of water pollution from inadequate sanitation and housing quality to diarrheal disease in low-cost housing settlements of Cape Town, South Africa. American Journal of Public Health, 7, 1–13.

    Google Scholar 

  • Grabow, W. O. K. (1996). Waterborne diseases: update on water quality assessment and control. Water SA, 2, 193–202.

    Google Scholar 

  • Hiraishi, A., Saheki, K., & Horie, S. (1984). Relationships of total coliforms, fecal coliform and organic pollution levels in the Tamagawa River. Bulletin of the Japanese Society for the Science of Fish, 50, 991–7.

    Article  Google Scholar 

  • Hunter, P. R. (2003). Drinking water and diarrheal disease due to Escherichia coli. Journal of Water and Health, 012, 65–71.

    Google Scholar 

  • Ibrahim, I. A. J., Al-Shwaikh, R. M., & Ismaeil, M. I. (2014). Virulence and antimicrobial resistance of Escherichia coli isolated from Tigris River and children diarrhea. Infection and Drug Resistance, 7, 317–322.

  • Igbinosa, E. O., & Okoh, A. I. (2009). Impact of discharged wastewater effluent on the physico-chemical qualities of a receiving watershed on a typical rural community. International Journal of Environmental Science and Technology, 6, 175–182.

    Article  CAS  Google Scholar 

  • Jaji, M. O., Bamgbose, O., Odukoya, O. O., & Arowlo, T. A. (2007). Water quality assessment of Ogun River, south west Nigeria. Environmental Monitoring and Assessment, 133, 447–482.

    Article  Google Scholar 

  • Kagalou, I., Tsimarakis, G., & Bezirtzoglou. (2002). Inter-relationships between bacteriological and chemical variations in Lake Pamvotis-Greece. Microbial Ecology in Health and Disease, 14, 37–41.

    Article  Google Scholar 

  • Ker’enyi, M., Allison, H. E., Batai, I., Sonnevend, A., Emody, L., Plaveczky, N., & Pal, T. (2005). Occurrence of hlyA and sheA genes in extraintestinal Escherichia coli strains. Journal of Clinical Microbiology, 43, 2965–2968.

    Article  Google Scholar 

  • Khan, A. B., & Naim, A. (2011a). Virulence traits of Shiga toxin producing Escherichia coli. The Health, 2, 119–127.

    Google Scholar 

  • Khan, A. B., & Naim, A. (2011b). Virulence traits of Shiga toxin producing Escherichia coli. The Health, 2, 119–127.

    Google Scholar 

  • Kusiluka, L. J. M., Karimuribo, E. D., Mdegele, R. H., Luoga, E. J., Munishi, P. K. T., Mlozi, M. R. S., & Kambarage, D. M. (2005). Prevalence and impact of water-borne zoonotic pathogens in water, cattle and humans in selected villages in Dodoma Rural and Bagamoyo districts, Tanzania. Physics and Chemistry of the Earth, 30, 818–825.

    Article  Google Scholar 

  • Li, D., Zeng, S., Gu, A. Z., He, M., & Shi, H. (2013). Inactivation, reactivation and regrowth of indigenous bacteria in reclaimed water after chlorine disinfection of a municipal wastewater treatment plant. Journal of Environmental Sciences, 25, 1319–1325.

    Article  CAS  Google Scholar 

  • Luczkiewicz, A., Jankowska, K., Fudala-Ksiazek, S., & Olanczuk-Neyman, K. (2010). Antimicrobial resistance of fecal indicators in municipal wastewater treatment plant. Water Resources, 44, 5089–5097.

    CAS  Google Scholar 

  • McCulloch, W. L., Goodfellow, W. L., & Black, J. A. (1993). Characterization, identification and confirmation of total dissolved solids as effluent toxicants. Environmental Toxicology and Risk Assessment, 2, 213–227.

    Article  Google Scholar 

  • Mema, V. (2002) Impact of poorly maintained wastewater and sewage treatment plants: lessons from South Africa. www.ewisa.co.za/literature/files/335_269%20Mema.pdf. Accesed 12 June 2013.

  • Modin, O., & Marie, B. (2012). A novel bioelectrochemical BOD sensor operating with voltage input. Water Research, 46, 6113–6120.

    Article  CAS  Google Scholar 

  • Momba, M. N. B., Osode, A. N., & Sibewu, M. (2002). The impact of inadequate wastewater treatment on the receiving water bodies case study: Buffalo city and Nkokonbe municipalities of the Eastern Cape province. Water SA, 32, 687–692.

    Google Scholar 

  • Morozzi, G., Cenci, G., & Scarabattoli, P. (1984). Bacteriological and chemical variations and their inter-relationships in a slightly polluted water-body. International Journal of Environmental Studies, 23, 121–9.

    Article  CAS  Google Scholar 

  • Morrison, G., Fatoki, O. S., Persson, L., & Ekberg, A. (2001). Assessment of the impact of point source pollution from the Keiskammahoek Sewage Treatment Plant on the Keiskammahoek River-pH, electrical conductivity, oxygen demanding substance (COD) and nutrients. Water SA, 4, 475–480.

    Google Scholar 

  • Muyima, N. Y. O., & Ngcakani, F. (1998). Indicator bacteria and regrowth potential of the drinking water in Alice, Eastern Cape. Water SA, 24, 29–34.

    CAS  Google Scholar 

  • Naidoo, S., & Olaniran, A. O. (2014). Treated wastewater effluent as a source of microbial pollution of surface water resources. International Journal of Environmental Research and Public Health, 11, 249–270.

    Article  CAS  Google Scholar 

  • Obi, C. L., Green, E., Bessong, P. O., deVilliers, B., Hoosen, A. A., Igumbor, E. O., & Potgieter, N. (2004). Gene encoding virulence markers among Escherichia coli isolates from diarrhoeic stool samples and river sources in rural Venda communities of South Africa. Water SA, 30, 37–42.

    CAS  Google Scholar 

  • Okpara, C. G., Oparaku, N. F., & Ibeto, C. N. (2011). An overview of water disinfection in developing countries and potentials of renewable energy. Journal of Environmental Science and Technology, 4, 18–30.

    Article  CAS  Google Scholar 

  • Olaniran, A. O., Naicker, K., & Pillay, B. (2009). Antibiotic resistance profiles of Escherichia coli isolates from river sources, Durban, South Africa. World Journal of Microbiology and Biotechnology, 25, 1473–1479.

    Article  Google Scholar 

  • Oliver, J. D. (2005). The viable but nonculturable state in bacteria. Journal of Microbiology, 43, 93–100.

    Google Scholar 

  • Olutiola, P. O., Awolowo, O., Oyedeji, O., Ayansina, A. D. V., & Cole, O. O. (2010). Relationship between bacterial density and chemical composition of a tropical sewage oxidation pond. African Journal of Environmental Science and Technology, 4, 595–602.

    CAS  Google Scholar 

  • Omar, K. B., & Barnard, T. G. (2014). Detection of diarrhoeagenic Escherichia coli in clinical and environmental water sources in South Africa using single step 11-gene m-PCR. World Journal of Microbiology and Biotechnology, 30, 2663–2671.

    Article  CAS  Google Scholar 

  • Osode, A. N., & Okoh, A. I. (2009). Impact of discharged wastewater final effluent on the physicochemical qualities of a receiving watershed in a suburban community of the Eastern Cape province. Clean: Soil, Air, Water, 12, 938–944.

    Google Scholar 

  • Ram, S., Vajpayee, P., Tripathi, U., Singh, R. L., Seth, P. K., & Shanker, R. (2008). Determination of antimicrobial resistance and virulence gene signatures in surface water isolates of Escherichia coli. Journal of Applied Microbiology, 105, 1899–1908.

    Article  CAS  Google Scholar 

  • Rebello, R. C., & Regua-Mangia, A. H. (2014). Potential enterovirulence and antimicrobial resistance in Escherichia coli isolates from aquatic environments in Rio de Janeiro, Brazil. Science of the Total Environment, 490, 19–27.

    Article  CAS  Google Scholar 

  • Rizzo, L., Manaia, C., Merlin, C., Schwartz, T., Dagot, C., Ploy, M. C., Michael, I., & Fatta, D. (2013). Urban wastewater treatment plants as hotspots for antibiotic resistant bacteria and genes spread into the environment: a review. Science of the Total Environment, 447, 345–360.

    Article  CAS  Google Scholar 

  • Santos, I. R., Costa, R. C., Freitas, U., & Fillmann, G. (2008). Influence of effluents from a wastewater treatment plant on nutrient distribution in a coastal creek from southern Brazil. Brazilian Journal of Science and Technology, 51, 153–162.

    CAS  Google Scholar 

  • Toze, S. (2004). Reuse of effluent water- benefits and risks, new directions for a diverse planet. http://www.cropscience.org.au/icsc2004/symposia/1/5/2086_toze.htm. Accesed 12 June 2013.

  • Tree, J. A., Adams, M. R., & Lees, D. N. (2003). Chlorination of indicator bacteria and viruses in primary sewage effluent. Applied and Environmental Microbiology, 69, 2038–2043.

    Article  CAS  Google Scholar 

  • Wang, L., & Reeves, P. R. (1998). Organization of Escherichia coli O157 O antigen gene cluster and identification of its specific genes. Infection and Immunity, 66, 3545–3551.

    CAS  Google Scholar 

  • Wang, L., Rothemund, D., Curd, H., & Reeves, P. R. (2000). Sequence diversity of the Escherichia coli H7 fliC genes implication for a DNA-based typing scheme for E. coli O157:H. Journal of Clinical Microbiology, 38, 1786–1790.

    CAS  Google Scholar 

  • Wilshaw, G. A., Cheasty, T., & Smith, H. R. (2000). Escherichia coli. Microbiological Safety and Quality of Food, 1, 1136–1177.

    Google Scholar 

  • World Health Organization (2002) World Health Report 2002—reducing risks, promoting healthy life. http://www.who.int/whr/2002/en/. Accessed 24 June 2013.

  • World Health Organization (2014) antimicrobial resistance: global report on surveillance. http://apps.who.int/iris/bitstream/10665/112642/1/9789241564748_eng.pdf. Accessed 1 December 2014.

  • Wose Kinge, C. N., Wose Kinge, M., Mbewe, N. P. Sithebe. (2012). Detection of bacterial pathogens in river water using multiplex-PCR, polymerase chain reaction. http://www.intechopen.com/books/polymerase-chain-reaction/detection-of-bacterial-pathogens-in-river-water-using-multiplex-pcr. Accessed 20 April 2012.

Download references

Acknowledgments

The authors wish to thank the Medical Research Council of South Africa and the University of KwaZulu-Natal, South Africa for financial assistance.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ademola O. Olaniran.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pillay, L., Olaniran, A.O. Assessment of physicochemical parameters and prevalence of virulent and multiple-antibiotic-resistant Escherichia coli in treated effluent of two wastewater treatment plants and receiving aquatic milieu in Durban, South Africa. Environ Monit Assess 188, 260 (2016). https://doi.org/10.1007/s10661-016-5232-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10661-016-5232-4

Keywords

Navigation