Abstract
Corneal stromal lenticule is a part of corneal stroma, which can be created by manual dissection, by femtosecond laser from the donor cornea, but chiefly it is a waste product of a refractive procedure ReLex SMILE (Small Incision Lenticule Extraction). Corneal lenticule has a huge potential in corneal surgery. In recent years, many studies have been published to show the possibility to use this tissue to treat corneal defects, as well as in refractive surgery. Thanks to the quantity of lenticules which arise every day during SMILE operations, this tissue is much more accessible than any other kind of corneal tissue. According to the experience with lenticule implantation in animal models, or even human patients, lenticule implantation is considered safe, reversible method, which is not associated with immune rejection or other severe complications. However, the crucial step before the process of lenticule implantation, is proper preservation of this tissue. Donor corneal tissue containing endothelium is usually preserved in hypothermia and then usable maximally for two weeks. Newer methods such as organ culture storage and use of a sterile cornea prolong the time of usability of the tissue. The possibilities for corneal lenticule storage are theoretically wider thanks to the fact, that we do not need to preserve fragile cellular structures. Besides the storage in hypothermia, other preserving methods such as cryopreservation and storage after decellularization have been tested. This review aimed to examine the current literature that describes possible methods of corneal lenticule preservation. A comprehensive search was created based on articles published in English on PubMed.gov, Cochranelibrary.com and Scopus.com using following keywords: corneal lenticule preservation, corneal lenticule storage, cold storage corneal lenticule, corneal lenticule cryopreservation till 2020.
Similar content being viewed by others
Data availability
All data supporting our findings will be shared upon request, although the majority is contained within the manuscript.
References
Amano S, Shimomura N, Yokoo S, Araki-Sasaki K, Yamagami S (2008) Decellularizing corneal stroma using N2 gas. Mol vis 14:878–882
Armitage WJ (2011) Preservation of Human Cornea. Transfusion Medicine and Hemotherapy: Offizielles Organ Der Deutschen Gesellschaft Fur Transfusionsmedizin Und Immunhamatologie 38(2):143–147. https://doi.org/10.1159/000326632
Bandeira F, Yam GH-F, Liu Y-C, Devarajan K, Mehta JS (2019) Three-dimensional neurite characterization of small incision lenticule extraction derived Lenticules. Invest Ophthalmol vis Sci 60(13):4408–4415. https://doi.org/10.1167/iovs.19-27566
Bhandari V, Ganesh S, Brar S, Pandey R (2016) Application of the SMILE-derived glued Lenticule patch graft in Microperforations and partial-thickness corneal defects. Cornea 35(3):408–412. https://doi.org/10.1097/ICO.0000000000000741
Calhoun WR, Akpek EK, Weiblinger R, Ilev IK (2015) Evaluation of broadband spectral transmission characteristics of fresh and gamma-irradiated corneal tissues. Cornea 34(2):228–234. https://doi.org/10.1097/ICO.0000000000000323
Daoud YJ, Smith R, Smith T, Akpek EK, Ward DE, Stark WJ (2011) The intraoperative impression and postoperative outcomes of gamma-irradiated corneas in corneal and glaucoma patch surgery. Cornea 30(12):1387–1391. https://doi.org/10.1097/ICO.0b013e31821c9c09
El Zarif M, Alió JL, Alió Del Barrio JL, De Miguel MP, Abdul Jawad K, Makdissy N (2021) Corneal stromal regeneration: A review of human clinical studies in Keratoconus treatment. Front Med 8:650724. https://doi.org/10.3389/fmed.2021.650724
Fasolo A, Galzignato A, Pedrotti E, Chierego C, Cozzini T, Bonacci E, Marchini G (2021) Femtosecond laser-assisted implantation of corneal stroma lenticule for keratoconus. Int Ophthalmol. https://doi.org/10.1007/s10792-021-01739-8
Ganesh S, Brar S, Rao PA (2014) Cryopreservation of extracted corneal lenticules after small incision lenticule extraction for potential use in human subjects. Cornea 33(12):1355–1362. https://doi.org/10.1097/ICO.0000000000000276
Hashimoto Y, Funamoto S, Sasaki S, Honda T, Hattori S, Nam K, Kimura T, Mochizuki M, Fujisato T, Kobayashi H, Kishida A (2010) Preparation and characterization of decellularized cornea using high-hydrostatic pressurization for corneal tissue engineering. Biomaterials 31(14):3941–3948. https://doi.org/10.1016/j.biomaterials.2010.01.122
He M, Jin H, He H, Ding H, Wang W, Liu L, Zhang C, Zhong X (2018) Femtosecond laser-assisted small incision endokeratophakia using a xenogeneic lenticule in rhesus monkeys. Cornea 37(3):354–361. https://doi.org/10.1097/ICO.0000000000001470
Chae JJ, Choi JS, Lee JD, Lu Q, Stark WJ, Kuo IC, Elisseeff JH (2015) Physical and biological characterization of the gamma-irradiated human cornea. Cornea 34(10):1287–1294. https://doi.org/10.1097/ICO.0000000000000555
Chaurasia S, Das S, Roy A (2020) A review of long-term corneal preservation techniques: relevance and renewed interests in the COVID-19 era. Indian J Ophthalmol 68(7):1357–1363. https://doi.org/10.4103/ijo.IJO_1505_20
Isidan A, Liu S, Li P, Lashmet M, Smith LJ, Hara H, Cooper DKC, Ekser B (2019) Decellularization methods for developing porcine corneal xenografts and future perspectives. Xenotransplantation 26(6):e12564. https://doi.org/10.1111/xen.12564
Islam MM, Sharifi R, Mamodaly S, Islam R, Nahra D, Abusamra DB, Hui PC, Adibnia Y, Goulamaly M, Paschalis EI, Cruzat A, Kong J, Nilsson PH, Argüeso P, Mollnes TE, Chodosh J, Dohlman CH, Gonzalez-Andrades M (2019) Effects of gamma radiation sterilization on the structural and biological properties of decellularized corneal xenografts. Acta Biomater 96:330–344. https://doi.org/10.1016/j.actbio.2019.07.002
Jhanji V, Sharma N, Vajpayee RB (2010) Intraoperative perforation of Descemet’s membrane during „big bubble" deep anterior lamellar keratoplasty. Int Ophthalmol 30(3):291–295. https://doi.org/10.1007/s10792-009-9334-7
Jin H, He M, Liu H, Zhong X, Wu J, Liu L, Ding H, Zhang C, Zhong X (2019) Small-incision femtosecond laser-assisted intracorneal concave lenticule implantation in patients with keratoconus. Cornea 38(4):446–453. https://doi.org/10.1097/ICO.0000000000001877
Jin H, Liu L, Ding H, He M, Zhang C, Zhong X (2018) Small incision femtosecond laser-assisted X-ray-irradiated corneal intrastromal xenotransplantation in rhesus monkeys: a preliminary study. Curr Mol Med 18(9):612–621. https://doi.org/10.2174/1566524019666190129123935
Li J, Shi S, Zhang X, Ni S, Wang Y, Curcio CA, Chen W (2012) Comparison of different methods of glycerol preservation for deep anterior lamellar keratoplasty eligible corneas. Invest Ophthalmol vis Sci 53(9):5675–5685. https://doi.org/10.1167/iovs.12-9936
Li M, Wei R, Yang W, Shang J, Fu D, Xia F, Choi J, Zhou X (2020) Femtosecond laser-assisted allogenic lenticule implantation for corneal Ectasia After LASIK: A 3-Year in vivo confocal microscopic investigation. J Refractive Surg (thorofare, n. J.: 1995) 36(11):714–722. https://doi.org/10.3928/1081597X-20200826-02
Li Q, Wang H, Dai Z, Cao Y, Jin C (2017) Preparation and biomechanical properties of an Acellular porcine corneal stroma. Cornea 36(11):1343–1351. https://doi.org/10.1097/ICO.0000000000001319
Liang G, Wang L, Pan Z, Zhang F (2019) Comparison of the different preservative methods for refractive lenticules following SMILE. Curr Eye Res 44(8):832–839. https://doi.org/10.1080/02713683.2019.1597890
Lindstrom RL, Kaufman HE, Skelnik DL, Laing RA, Lass JH, Musch DC, Trousdale MD, Reinhart WJ, Burris TE, Sugar A (1992) Optisol corneal storage medium. Am J Ophthalmol 114(3):345–356. https://doi.org/10.1016/s0002-9394(14)71803-3
Liu Y-C, Williams GP, George BL, Soh YQ, Seah XY, Peh GSL, Yam GHF, Mehta JS (2017) Corneal lenticule storage before reimplantation. Mol vis 23:753–764
Mastropasqua L, Nubile M, Salgari N, Mastropasqua R (2018) Femtosecond laser-assisted stromal lenticule addition keratoplasty for the treatment of advanced keratoconus: a preliminary study. J Refractive Surg (thorofare, N.J. 1995) 34(1):36–44. https://doi.org/10.3928/1081597X-20171004-04
Mohamed-Noriega K, Toh K-P, Poh R, Balehosur D, Riau A, Htoon HM, Peh GSL, Chaurasia SS, Tan DT, Mehta JS (2011) Cornea lenticule viability and structural integrity after refractive lenticule extraction (ReLEx) and cryopreservation. Mol vis 17:3437–3449
Oh JY, Kim MK, Lee HJ, Ko JH, Wee WR, Lee JH (2009) Comparative observation of freeze-thaw-induced damage in pig, rabbit, and human corneal stroma. Veterinary Ophthalmol 12(Suppl 1):50–56. https://doi.org/10.1111/j.1463-5224.2009.00723.x
Pradhan KR, Reinstein DZ, Carp GI, Archer TJ, Gobbe M, Gurung R (2013) Femtosecond laser-assisted keyhole endokeratophakia: Correction of hyperopia by implantation of an allogeneic lenticule obtained by SMILE from a myopic donor. J Refractive Surg (thorofare, N.J.: 1995) 29(11):777–782. https://doi.org/10.3928/1081597X-20131021-07
Raeder S, Utheim TP, Utheim OA, Nicolaissen B, Roald B, Cai Y, Haug K, Kvalheim A, Messelt EB, Drolsum L, Reed JC, Lyberg T (2007) Effects of organ culture and Optisol-GS storage on structural integrity, phenotypes, and apoptosis in cultured corneal epithelium. Invest Ophthalmol vis Sci 48(12):5484–5493. https://doi.org/10.1167/iovs.07-0494
Riau AK, Angunawela RI, Chaurasia SS, Lee WS, Tan DT, Mehta JS (2013) Reversible femtosecond laser-assisted myopia correction: A non-human primate study of lenticule re-implantation after refractive lenticule extraction. PLoS ONE 8(6):e67058. https://doi.org/10.1371/journal.pone.0067058
Riau AK, Liu Y-C, Yam GHF, Mehta JS (2020) Stromal keratophakia: corneal inlay implantation. Prog Retin Eye Res 75:100780. https://doi.org/10.1016/j.preteyeres.2019.100780
Sachdev MS, Gupta D, Sachdev G, Sachdev R (2015) Tailored stromal expansion with a refractive lenticule for crosslinking the ultrathin cornea. J Cataract Refract Surg 41(5):918–923. https://doi.org/10.1016/j.jcrs.2015.04.007
Shang Y, Li Y, Wang Z, Sun X, Zhang F (2021) Risk Evaluation of human corneal stromal lenticules from SMILE for reuse. J Refractive Surg (thorofare, N.J.: 1995) 37(1):32–40. https://doi.org/10.3928/1081597X-20201030-03
Stevenson W, Cheng S-F, Emami-Naeini P, Hua J, Paschalis EI, Dana R, Saban DR (2012) Gamma-irradiation reduces the allogenicity of donor corneas. Invest Ophthalmol vis Sci 53(11):7151–7158. https://doi.org/10.1167/iovs.12-9609
Sun L, Yao P, Li M, Shen Y, Zhao J, Zhou X (2015) The Safety and predictability of implanting autologous Lenticule obtained by SMILE for hyperopia. J Refractive Surg (thorofare, n. j: 1995) 31(6):374–379. https://doi.org/10.3928/1081597X-20150521-03
Sun Y, Zhang T, Zhou Y, Liu M, Zhou Y, Yang X, Weng S, To C-H, Liu Q (2016) Reversible femtosecond laser-assisted endokeratophakia using cryopreserved allogeneic corneal lenticule. J Refractive Surg (thorofare, n. j: 1995) 32(8):569–576. https://doi.org/10.3928/1081597X-20160523-02
Trias E, Gallon P, Ferrari S, Piteira AR, Tabera J, Casaroli-Marano RP, Parekh M, Ruzza A, Franch A, Ponzin D (2020) Banking of corneal stromal lenticules: a risk-analysis assessment with the EuroGTP II interactive tool. Cell Tissue Bank 21(2):189–204. https://doi.org/10.1007/s10561-020-09813-8
Tripathi H, Mehdi MU, Gupta D, Sen S, Kashyap S, Nag TC, Purwar M, Jassal M, Agrawal AK, Mohanty S, Tandon R (2016) Long-term preservation of donor corneas in glycerol for keratoplasty: Exploring new protocols. Br J Ophthalmol 100(2):284–290. https://doi.org/10.1136/bjophthalmol-2015-306944
Wu F, Jin X, Xu Y, Yang Y (2015) Treatment of corneal perforation with lenticules from small incision lenticule extraction surgery: a preliminary study of 6 patients. Cornea 34(6):658–663. https://doi.org/10.1097/ICO.0000000000000397
Xia F, Zhao J, Fu D, Xu Y, Yao P, Li M, Aruma A, Zhou X (2020) Optical transmittance and ultrastructure of SMILE-derived lenticules subjected to three different preservative methods. Exp Eye Res 201:108357. https://doi.org/10.1016/j.exer.2020.108357
Yam GH-F, Yusoff NZBM, Goh T-W, Setiawan M, Lee X-W, Liu Y-C, Mehta JS (2016) Decellularization of human stromal refractive lenticules for corneal tissue engineering. Sci Rep 6:26339. https://doi.org/10.1038/srep26339
Yang H, Zhou Y, Zhao H, Xue J, Jiang Q (2020) Application of the SMILE-derived lenticule in therapeutic keratoplasty. Int Ophthalmol 40(3):689–695. https://doi.org/10.1007/s10792-019-01229-y
Yoeruek E, Bayyoud T, Maurus C, Hofmann J, Spitzer MS, Bartz-Schmidt K-U, Szurman P (2012) Reconstruction of corneal stroma with decellularized porcine xenografts in a rabbit model. Acta Ophthalmol 90(3):e206-210. https://doi.org/10.1111/j.1755-3768.2011.02300.x
Yoshida J, Heflin T, Zambrano A, Pan Q, Meng H, Wang J, Stark WJ, Daoud YJ (2015) Gamma-irradiated sterile cornea for use in corneal transplants in a rabbit model. Middle East Afr J Ophthalmol 22(3):346–351. https://doi.org/10.4103/0974-9233.159760
Zheng X, Zhang D, Li S, Zhang J, Zheng J, Du L, Gao J (2018) An experimental study of femto-laser in assisting xenograft acellular cornea matrix lens transplantation. Med Sci Monitor: Int Med J Exp Clin Res 24:5208–5215
Acknowledgements
I would like to express my special regards to the Charles University Grant Agency.
Funding
The Charles University Grant agency.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Nemcokova, M., Dite, J., Klimesova, Y.M. et al. Preservation of corneal stromal lenticule: review. Cell Tissue Bank 23, 627–639 (2022). https://doi.org/10.1007/s10561-021-09990-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10561-021-09990-0