Skip to main content
Log in

Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Prosthesis-patient mismatch (PPM) occurs when the effective orifice area of the prosthesis is too small in relation to the patient's body surface area. There are few data available on the frequency and prognostic impact of PPM after transcatheter aortic valve implantation (TAVI). Our aim was to determine the prevalence of PPM and to investigate its association with medium-term clinical course of patients undergoing TAVI. We included 185 patients undergoing TAVI (79 ± 5 years, 49% male, 98% CoreValve) between April-2008 and December-2014. The effective orifice area (EOA) was determined by transthoracic echocardiography prior and after the procedure. We defined PPM as indexed EOA ≤ 0.85 cm2/m2 (severe PPM if ≤ 0.65 cm2/m2). All cause death, stroke and hospitalization for heart failure were considered as major clinical events. 45 patients (24%) showed PPM (severe 11 patients, 6%). PPM was associated with a higher EuroSCORE (OR 1.06, IC 95% 1.01–1.12, p = 0.03), body surface area ≥ 1.72 m2 (OR 3.58, IC 95% 1.30–9.87, p = 0.01) and small aortic annulus (OR 0.73, IC 95% 0.55–0.92, p = 0.03); and severe PPM with small prostheses size (OR 17.79, IC 95% 1.87–169.78, p = 0.012). The mean event-free survival was 34 ± 26 months. Patients with severe PPM showed lower rates of event free survival than the rest of the series (52% vs. 84%, p = 0.04) at 34 months follow up. In our series, PPM was present in a quarter of the patients after TAVI. Higher EuroSCORE, smaller prosthesis size, larger body surface area and smaller aortic annulus diameter were associated with PPM. Severe PPM was an independent factor associated with major events at medium-term follow up.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Grube E, Schuler G, Buellesfeld L, Gerckens U, Linke A, Zickmann B et al (2007) Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding Core-Valve Prosthesis. J Am Coll Cardiol 50:69–76

    Article  PubMed  Google Scholar 

  2. Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G et al (2011) Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients. Circulation 123:299–308

    Article  PubMed  Google Scholar 

  3. Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607

    Article  CAS  PubMed  Google Scholar 

  4. Smith C, Leon M, Mack M, Miller D, Moses J, Svensson L et al (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364(23):2187–2198

    Article  CAS  PubMed  Google Scholar 

  5. Kodali S, Williams M, Smith S, Lars G, Webb JG, Makkar RR et al (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366:1686–1695

    Article  CAS  PubMed  Google Scholar 

  6. Hahn R, Pibarot P, Stewart W, Weissman NJ, Gopalakrishnan D, Keane MG et al (2013) Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis a longitudinal study of echocardiography parameters in Cohort A of the PARTNER trial (placement of aortic transcatheter valves). JACC 61(25):2514–21

    Article  PubMed  Google Scholar 

  7. Holmes DR, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR et al (2012) 2012 ACCF / AATS / SCAI / STS expert consensus document on transcatheter aortic valve replacement. Cathet Cardiovasc Interv 79:1023–1082

    Article  Google Scholar 

  8. Avanzas P, Pascual I, Muñoz-García AJ, Segura J, Alonso-briales JH, Suárez de Lezo J et al (2017) Seguimiento a largo plazo de pacientes con estenosis aórtica grave tratados con prótesis autoexpandible. Rev Esp Cardiol 70(4):247–253

    Article  PubMed  Google Scholar 

  9. Lancellotti P, Pibarot P, Chambers J et al (2016) Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging 17:589–590

    Article  PubMed  Google Scholar 

  10. Kappetein AP, Head SJ, Genereux P, Piazza N, Van Mieghem NM, Blackstone EH et al (2012) Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur J Cardiothorac Surg 42:S45–S60

    Article  PubMed  Google Scholar 

  11. Dumesnil J, Pibarot P (2011) Prosthesis-patient mismatch: an update. Curr Cardiol Rep 13(3):250–257

    Article  PubMed  Google Scholar 

  12. Takagi H, Yamamoto H, Iwata K, Goto SN, Umemoto T (2012) A meta-analysis of effects of prosthesis-patient mismatch after aortic valve replacement on late mortality. Int J Cardiol 159(2):150–154

    Article  PubMed  Google Scholar 

  13. Chen J, Lin Y, Kang B, Wang Z (2014) Indexed effective orifice area is a significant predictor of higher mid- and long-term mortality rates following aortic valve replacement in patients with prosthesis-patient mismatch. Eur J Cardio-thoracic Surg 45(2):234–240

    Article  Google Scholar 

  14. Takagi H, Umemoto T (2016) Prosthesis-patient mismatch after transcatheter aortic valve implantation. Ann Thorac Surg 101(3):872–880

    Article  PubMed  Google Scholar 

  15. Pibarot P, Weissman NJ, Stewart WJ, Hahn RT, Lindman BR, McAndrew T et al (2014) Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort-a analysis. J Am Coll Cardiol 64(13):1323–1334

    Article  PubMed  PubMed Central  Google Scholar 

  16. Muñoz-García AJ, Muñoz-García M, Carrasco-Chinchilla F, Molina-Mora MJ, Rodríguez-Bailón I, Domínguez-Franco AJ et al (2013) Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis. Int J Cardiol 167(3):1074–1076

    Article  PubMed  Google Scholar 

  17. Zorn GL, Little SH, Tadros P, Deeb GM, Gleason TG, Heiser J et al (2016) Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: a randomized trial of a self-expanding prosthesis. J Thorac Cardiovasc Surg 151(4):1014–1023

    Article  PubMed  Google Scholar 

  18. da Silva C, Sahlen A, Winter R, Bäck M, Rück A, Settergren M et al (2014) Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography. Int J Cardiovasc Imaging 30:1549–1557

    Article  PubMed  Google Scholar 

  19. Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA et al (2009) Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound. A report from the American Society of Echocardiography’s guidelines and standards committee and the task force on prosthetic valves, developed in conjunction. J Am Soc Echocardiogr 22(9):975–1014

    Article  PubMed  Google Scholar 

  20. Quiñones M, Douglas P, Foster E, Gorcsan J, Lewis J, Pearlman A et al (2003) ACC/AHA clinical competence statement on echocardiography: a report of the American College of Cardiology/American Heart Association/American College of Physicians–American Society of Internal Medicine. Task force on clinical competence. JACC 41:687–708

    Article  PubMed  Google Scholar 

  21. Evangelista A, María Á, Gómez A, Durán RM, Yagüela MM, María J et al (2000) Guías de práctica clínica de la Sociedad Española de Cardiología en ecocardiografía. Rev Esp Cardiol 53(5):663–683

    Article  Google Scholar 

  22. Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA et al (2006) Recommendations for chamber quantification. Eur J Echocardiogr 7(2):79–108

    Article  PubMed  Google Scholar 

  23. Dubois D, Dubois E (1916) A formula to estimate the approximate surface area of height and weight be known. Arch Intern Med 17:863–871

    Article  CAS  Google Scholar 

  24. Mesa D, Suárez de Lezo J, Alvarez-Ossorio M, Ruiz Ortiz M, Delgado Ortega M, León del Pino M et al (2011) Measurement of aortic valve annulus using different cardiac imaging techniques in transcatheter aortic valve implantation: agreement with finally implanted prosthesis size. Echocardiography 28:388–396

    Article  Google Scholar 

  25. León C, Suárez de Lezo J, Mesa D, Pan M, Ruiz M, Delgado M et al (2011) Early development of leaks in the CoreValve percutaneous aortic valve prosthesis: echocardiographic assessment. Rev Esp Cardiol 64:67–70

    Article  PubMed  Google Scholar 

  26. Cejudo Díaz del Campo L, Mesa Rubio D, Ruiz Ortiz M, Delgado Ortega M, Pan M, Ojeda Pineda S et al (2012) Usefulness of transesophageal echocardiography during implantation of the CoreValve percutaneous aortic prosthesis: Influence of the learning curve. Catheter Cardiovasc Interv 80:964–971

    Article  Google Scholar 

  27. Avanzas P, Munoz-Garcia A, Segura J, Pan M, Alonso-Briales J, Lozano I et al (2010) Percutaneous Implantation of the CoreValve(registered trademark) self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Rev Esp Cardiol 63(2):141–148

    Article  PubMed  Google Scholar 

  28. Rodés-cabau J, Pibarot P, Suri RM, Kodali S, Thourani VH, Szeto WY et al (2014) Impact of aortic annulus size on valve hemodynamics and clinical outcomes after transcatheter and surgical aortic valve replacement insights from the PARTNER trial. Circ Cardiovasc Interv 7:701–711

    Article  PubMed  Google Scholar 

  29. Pibarot P, Clavel M, Dahou A (2015) Patient and procedure selection for the prevention of prosthesis-patient mismatch following aortic valve replacement. EuroIntervention 11:106–109

    Article  Google Scholar 

  30. Lebera A, Eichingerc W, Rieberb J, Lieberc M, Schlegerc S, Ebersbergerb U et al (2013) MSCT guided sizing of the Edwards Sapien XT TAVI device: Impact of different degrees of oversizing on clinical outcome. Int J Cardiol 168(3):2658–2664

    Article  Google Scholar 

  31. Samim M, Stella PR, Agostoni P, Kluin J, Ramjankhan F, Sieswerda G et al (2013) A prospective “oversizing” strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation. J Thorac Cardiovasc Surg 145(2):398–405

    Article  PubMed  Google Scholar 

  32. Dayan V, Soca G, Stanham R, Lorenzo A, Ferreiro A (2015) Is patient–prosthesis mismatch a predictor of survival or a surrogate marker of co-morbidities in cardiac surgery? Int J Cardiol 190:389–392

    Article  PubMed  Google Scholar 

  33. Tzikas A, Piazza N, Geleijnse ML, Van Mieghem N, Nuis RJ, Schultz C et al (2010) Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic corevalve system in patients with aortic stenosis. Am J Cardiol 106(2):255–260

    Article  PubMed  Google Scholar 

  34. Nishimura R, Otto C, Bonow R, Mack M, Carabello B, McLeod C et al (2017) 2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association task force on clinical practice guidelines. Circulation 135(21):1–123

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to María del Carmen León del Pino.

Ethics declarations

Conflict of interest

The authors whose names are listed in the first page report no affiliation nor involvement in an organization or entity with a financial or non-financial interest in the subject matter or materials discussed in this manuscript.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

León del Pino, M.C., Ruíz Ortiz, M., Delgado Ortega, M. et al. Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact. Int J Cardiovasc Imaging 35, 827–836 (2019). https://doi.org/10.1007/s10554-018-01519-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-018-01519-z

Keywords

Navigation