An improved design of optical sensor for long-term measurement of arterial blood flow waveform

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

We present here the improved design and development of optical sensor for non-invasive measurements of arterial blood flow waveform. The sensor is based on a physical principle of reflective photoplethysmography (PPG). As the light source we used serially connected infrared diodes whereas NPN silicon phototransistors were used as light detectors. The electronic components were molded into square package and poured with silicone. Such preparation produced an elastic superficies that allowed excellent attachment of the sensor on the skin’s surface. Moreover, a serial connection of infrared diodes and phototransistors completely eliminated signal artifacts caused by minor muscle contractions. The sensor recording performances were examined at the photoplethysmographic sites on three different arteries; the commune carotid, femoral and radial and, on each site the sensor demonstrated remarkable capability to make a consistent, reproducible measurements. Because of the advantageous physical and electrical properties, the new sensor is suitable for various cardiovascular diagnostics procedures, especially when long-term measurements of arterial blood flow waveform are required, for monitoring of different parameters in cardiovascular units and for research.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  • J. Allen, Photoplethysmography and its application in clinical physiological measurement. Physiol. Meas. 28, R1–R39 (2007)

    Article  Google Scholar 

  • C. Arthurs, K. Lau, K. Asrress, S. Redwood, A. Figueroa, A mathematical model of coronary blood flow control: Simulation of patient-specific three-dimensional hemodynamics during exercise. Am. J. Phys. Heart Circ. Phys. 310(9), H1242–H1258 (2016)

    Google Scholar 

  • P.A. Bascom, K.W. Johnston, R.S. Cobbold, M. Ohja, Relation of the flow field distal to a moderate stenosis to the Doppler power. Ultrasound Med. Biol. 23(1), 25–39 (1997)

    Article  Google Scholar 

  • S. Born, M. Pfeifle, M. Markl, M. Gutberlet, G. Scheuermann, Visual analysis of cardiac 4D MRI blood flow using line predicates. IEEE Trans. Vis. Comput. Graph. 19(6), 900–912 (2013)

    Article  Google Scholar 

  • J. Borresen, M.I. Lambert, Autonomic control of heart rate during and after exercise: Measurements and implications for monitoring training status. Sports Med. 38(8), 633–646 (2008)

    Article  Google Scholar 

  • I. Cederholm, J. Sorensen, C. Carlsson, Thrombosis following percutaneous radial artery cannulation. Acta Anaesthesiol. Scand. 30, 227–230 (1986)

    Article  Google Scholar 

  • D.B. Chaffin, Localized muscle fatigue--definition and measurement. J. Occup. Med. 15(4), 346–354 (1973)

    Google Scholar 

  • R. Flore, F.R. Ponziani, G. Tinelli, et al., New modalities of ultrasound-based intima-media thickness, arterial stiffness and non-coronary vascular calcifications detection to assess cardiovascular risk. Eur. Rev. med. And Pharm. Sci. 19, 1430–1441 (2015)

    Google Scholar 

  • E.E. Frezza, H. Mezghebe, Indications and complications of arterial catheter use in surgical or medical intensive care units: Analysis of 4932 patients. Am. Surg. 64, 127–131 (1998)

    Google Scholar 

  • J. He, Y. Kinouchi, T. Iritani, H. Yamaguchi, H. Miyamoto, Telemetering blood flow velocity and ECG during exercise. Innov. Technol. Biol. Med. 13(5), 567–577 (1992)

    Google Scholar 

  • D.W. Holdsworth, C.J. Norley, R. Frayne, D.A. Steinman, B.K. Rutt, Characterization of common carotid artery blood-flow waveforms in normal human subjects. Physiol. Meas. 20(3), 219–240 (1999)

    Article  Google Scholar 

  • M.K. Lahiri, P.J. Kannankeril, J.J. Goldberger, Assessment of autonomic function in cardiovascular disease: Physiological basis and prognostic implications. J. Am. Coll. Cardiol. 51(18), 1725–1733 (2008)

    Article  Google Scholar 

  • C.P. Loizou, A review of ultrasound common carotid artery image and video segmentation techniques. Med. Biol. Eng. Comput. 52(12), 1073–1093 (2014)

    Article  Google Scholar 

  • S. Moore, T. David, J.G. Chase, J. Arnold, J. Fink, 3D models of blood flow in the cerebral vasculature. J. Biomech. 39(8), 1454–1463 (2006)

    Article  Google Scholar 

  • J.M. Perlman, J.J. Volpe, Seizures in the preterm infant: Effects on cerebral blood flow velocity, intracranial pressure, and arterial blood pressure. J. Pediatr. 102(2), 288–293 (1983)

    Article  Google Scholar 

  • P. Samet, Hemodynamic sequelae of cardiac arrhythmias. Circulation 47(2), 399–407 (1973)

    Article  Google Scholar 

  • A. Srámek, J.G. Bosch, J.H. Reiber, J.A. Van Oostayen, F.R. Rosendaal, Ultrasound assessment of atherosclerotic vessel wall changes: Reproducibility of intima-media thickness measurements in carotid and femoral arteries. Investig. Radiol. 35(12), 699–706 (2000)

    Article  Google Scholar 

  • H. Vadmann, P.B. Nielsen, S.P. Hjortshøj, et al., Atrial flutter and thromboembolic risk: A systematic review. Heart 101(18), 1446–1455 (2015)

    Article  Google Scholar 

  • M. Vahid, Sleep-related breathing disorders and risk of stroke. Stroke 32, 1271–1278 (2001)

    Article  Google Scholar 

  • B.E. Van Leeuwen, G.J. Barendsen, J. Lubbers, L. Pater, Calf blood flow and posture: Doppler ultrasound measurement during and after exercise. J. Appl. Physiol. 72(5), 1675–1680 (1992)

    Google Scholar 

  • D. Žikić, An improved reflective photoplethysmograph probe design for detection of an arterial blood flow. J. Med. Eng. & Tech. 32(1), 23–29 (2008)

    Article  Google Scholar 

  • D. Zikich, D. Zikic, Arterial Blood Flow Sensor. IFMBE Proc. 22, 1158–1162 (2008)

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported by Serbian Ministry of Education and Science Projects 32040 and 41022.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dejan Žikić.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Djurić, B., Suzić, S., Stojadinović, B. et al. An improved design of optical sensor for long-term measurement of arterial blood flow waveform. Biomed Microdevices 19, 48 (2017). https://doi.org/10.1007/s10544-017-0196-x

Download citation

  • Published:

  • DOI: https://doi.org/10.1007/s10544-017-0196-x

Keywords

Navigation