Abstract
Seismic behaviour of masonry buildings, built of low compressive strength units, is discussed. Although such materials have already been tested and approved for use from mechanical and thermal insulation point of view, the knowledge regarding their structural behaviour is still lacking. In order to investigate the resistance and deformation capacity of this particular type of masonry construction in seismic conditions, a series of eight walls and model of a two-storey full scale confined masonry building have been tested by subjecting the specimens to cyclic shear loads. All tests were conducted under a combination of constant vertical load and quasi static, cyclically imposed horizontal load. The behaviour of tested specimens was of typical shear type. Compared with the behaviour of plain masonry walls, the presence of tie-columns resulted into higher resistance and displacement capacity, as well as smaller lateral resistance degradation. The response of the model was determined by storey mechanism with predominant shear behaviour of the walls and failure mechanism of the same type as in the case of individual confined masonry walls. Adequate seismic behaviour of this particular masonry structural type can be expected under the condition that the buildings are built as confined masonry system with limited number of stories.
Similar content being viewed by others
References
Alcocer SM, Meli R (1995) Test program on the seismic behavior of confined masonry walls. Mason Soc J 13:68–76
Bernardini A, Modena C, Turnšek V, Vescovi U (1980) A comparison of three laboratory test methods used to determine the shear resistance of masonry walls. In: Proceedings of the 7th world conference on earthquake engineering, vol 7. International Association for Earthquake Engineering, Istanbul, pp 181–184
CEN (1999) Methods of test for masonry. In: Determination of compressive strength. EN 1052-1:1999. Bruxelles
CEN (2004) Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings, EN 1998-1. Bruxelles
CEN (2005) Eurocode 6: design of masonry structures—part 1-1: general rules for buildings—rules for reinforced and unreinforced masonry, EN 1996-1-1. Bruxelles
CEN (2011) Specification for masonry units. Clay masonry units. EN 771-1:2011 + A1:2015. Bruxelles
Faustino J, Silva E, Pinto J, Soares E, Cunha VMCF, Soares S (2015) Lightweight concrete masonry units based in processed granulate of corn cob as aggregate. Mater Constr 65:318. https://doi.org/10.3989/mc.2015.04514
ISO (2016) ISO 6892-1:2016. Metallic materials—tensile testing—part 1: method of test at room temperature
Mueller A, Schnell A, Ruebner K (2015) The manufacture of lightweight aggregates from recycled masonry rubble. Constr Build Mater 98:376–387. https://doi.org/10.1016/j.conbuildmat.2015.07.027
SIST (2005) - Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings—National Annex, SIST EN 1998-1:2005/A101:2006. Ljubljana, Slovenia
Tomaževič M (1978) Improvement of computer program POR. Report ZRMK-IK, Ljubljana (in Slovene)
Tomaževič M (2007) Damage as a measure for earthquake-resistant design of masonry structures: Slovenian experience. Can J Civ Eng 34(11):1403–1412
Tomaževič M (2009) Shear resistance of masonry walls and Eurocode 6: shear versus tensile strength of masonry. Mater Struct 42(17):889–907
Tomaževič M, Klemenc I (1997) Seismic behaviour of confined masonry walls. Earthq Eng Struct Dyn 26:1059–1072
Turnšek V, Čačovič F (1971) Some experimental results on the strength of brick masonry walls. In: Proceedings 2nd international brick-masonry conference. British Ceramic Society, Stoke-on-Trent, pp 149–156
Turnšek V, Sheppard P (1980) The shear and flexural resistance of masonry walls. In: Proceedings of the international research conference on earthquake engineering. Skopje, pp 517–568
Umek A (1971) Comparison between unreinforced, confined and horizontally reinforced masonry walls. Civ Eng 20:241–248
Acknowledgements
The research presented in this article was carried out within the framework of research Project J2-6749, financed by the Slovenian Research Agency and a research Project, supported by Lafarge Cement d.o.o., Slovenia.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Triller, P., Tomaževič, M. & Gams, M. Seismic behaviour of masonry buildings built of low compressive strength units. Bull Earthquake Eng 16, 6191–6219 (2018). https://doi.org/10.1007/s10518-018-0418-5
Received:
Accepted:
Published:
Issue Date: