The aim of this study was the quantification of the apical fixation forces of mitral valved stents for the first time. A test set-up was developed to measure the forces acting on the apical fixation of mitral valved stents. Twenty pigs received a self-expanding valved stent in the mitral position via a transapical approach in an off-pump procedure. Following stent deployment in the beating heart, the apical fixation forces were recorded following a standardized protocol and normalized. The apical fixation force of two different valved stent designs (AP: sole apical fixation, n = 10; SA: additional sub-annular fixation, n = 10) was compared to quantify the impact of the design change. Force measurement was successfully conducted in 18 of 20 animals (design AP: n = 10; design SA: n = 8). Evaluation showed higher mean forces and amplitude in the group with sole apical fixation (p = 0.046; Table 1). The impact of the additional sub-annular fixation was shown by a significant reduction of the force acting upon the apex of the heart. Quantification of these in vivo forces provides important information about the impact of different stent designs and might provide an objective parameter for stent performance evaluation in clinical application.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6

Similar content being viewed by others

References

  1. Attmann, T., S. Pokorny, L. Lozonschi, A. Metzner, M. Marczynski-Bühlow, J. Schoettler, J. Cremer, and G. Lutter. Mitral valved stent implantation: an overview. Minim. Invasive Ther. Allied Technol. 20(2):78–84, 2011

  2. Banai, S., M. Jolicoeur, M. Schwartz, P. Garceau, S. Biner, J. F. Tanguay, R. Cartier, S. Verheye, C. White, and E. Edelman. Tiara: a novel catheter-based mitral valve bioprosthesis initial experiments ans short-term pre-clinical results. J. Am. Coll. Cardiol. Intv. 60(15):1430–1431, 2012.

  3. Banai, S., S. Verheye, A. Cheung, M. Schwartz, A. Marko, P. R. Lane, M. Jolicoeur, P. Garceau, S. Biner, J. F. Tanguay, E. Edelman, and C. White. Transapical mitral implantation of the tiara bioprosthesis. J. Am. Coll. Cardiol. Intv. 7(2):154–162, 2014.

  4. Cho, I. J., J. Moon, C. Y. Shim, Y. Jang, N. Chung, B. C. Chang, and J. W. Ha. Different clinical outcome of paravalvular leakage after aortic or mitral valve replacement. Am. J. Cardiol. 107(2):280–284, 2011.

  5. De Backer, O., N. Piazza, S. Banai, G. Lutter, F. Maisano, H. C. Herrmann, O. W. Franzen, and L. Søndergaard. Percutaneous transcatheter mitral valve replacement: an overview of devices in preclinical and early clinical evaluation. Circ. Cardiovasc. Interv. 7(3):400–409, 2014.

  6. Iino, K., J. Boldt, L. Lozonschi, A. Metzner, J. Schoettler, R. Petzina, J. Cremer, and G. Lutter. Off-pump transapical mitral valve replacement: evaluation after one month. Eur. J. Cardiothorac. Surg. 41:512–517, 2012.

  7. Janiszewski, A., R. Paslawski, A. Cepiel, A. Noszczyk-Nowak, L. Kiczak, J. Nicpon, and W. Witkiewicz. Normal M-mode echocardiography of mitral valve in adult domestic swine. J. Anim. Vet. Adv. 12(15):1260–1261, 2013.

  8. Lozonschi, L., R. Quaden, N. M. Edwards, J. Cremer, and G. Lutter. Transapical mitral valved stent implantation. Ann. Thorac. Surg. 86(3):745–748, 2008.

  9. Mirabel, M., B. Iung, G. Baron, D. Messika-Zeitoun, D. Détaint, J. L. Vanoverschelde, E. G. Butchart, P. Ravaud, and A Vahanian. What are the characteristics of patients with severe, symptomatic, mitral regurgitation who are denied surgery?. Eur. Heart J. 28:1358–1365, 2007.

  10. Nations U. Department of Economic and Social Affairs, Populations Division. World Population Prospects: The 2010 Revision. CD-ROM Edition, 2011.

  11. Nielsen, S. L., D.D. Soerensen, P. Libergren, A. P. Yoganathan, and H. Nygaard. Miniature C-shaped transducers for chordae tendinae force measurements. Ann. Biomed. Eng. 32(8):1050–1057, 2004.

  12. Pokorny, S., H. D. Dai, T. Bähr, K. Huenges, M. Marczynski-Bühlow, M. M. Morlock, J. Cremer, and G. Lutter. Transapical mitral valved stent implantation: comparison between circular and D-shaped design. EuroIntervention 2013 Nov 25 [E-pub ahead of print] pii: 20130415-07.

  13. Pokorny, S., K. Huenges, T. Bähr, J. H. Hansen, G. Fischer, J. Gross, M. Morlock, J. Cremer, and G. Lutter. Transapical mitral valved stent implantation: Enhanced survival and decreased paravalvular leakages. Int. J. Cardiol. 2014 Jun 19. doi:10.1016/j.ijcard.2014.06.007. Epub ahead of print.

  14. Pokorny, S., A. Heinig, H. Hettich, T. Bähr, M. Marczynski-Bühlow, M. M. Morlock, B. Sattler, J. Schöttler, and G. Lutter. Transapical mitral valved stent implantation: computed tomographic evaluation of different prototype designs. EuroIntervention 2014, published ahead of print August 2014.

  15. Siefert, A. W., J. H. Jimenez, K. J. Koomalsingh, F. Aguel, D. S. West, T. Shuto, T. K. Snow, R. C. Gorman, J. H. Gorman, and A. P. Yoganathan. Contractile mitral annular forces are reduced with ischemic mitral regurgitation. J. Thorac. Cardiovasc. Surg. 146(2):422–428, 2013.

  16. Siefert, A. W., J. P. Rabbah, E. L. Pierce, K. S. Kunzelman, and A. P. Yoganathan. Quantitative evaluation of annuloplasty on mitral valve chordae tendineae forces to supplement surgical planning model development. Cardiovasc. Eng. Technol. 5(1):35–43, 2014.

  17. Statistisches Bundesamt. Länderprofil, G-20 Industrie- und Schwellenländer, Vereinigte Staaten 2011. https://www.destatis.de/DE/Publikationen/Thematisch/Internationales/Laenderprofile/USA2011.html (15 Februar 2013).

Download references

Acknowledgments

This project on mitral valve replacement was supported by the German Research Foundation, Bonn, Germany (Grant LU 663/8-1) and the DZHK (German Centre for Cardiovascular Research).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Pokorny.

Additional information

Associate Editor Jane Grande-Allen oversaw the review of this article.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pokorny, S., Huenges, K., Engel, A. et al. In Vivo Quantification of the Apical Fixation Forces of Different Mitral Valved Stent Designs in the Beating Heart. Ann Biomed Eng 43, 1201–1209 (2015). https://doi.org/10.1007/s10439-014-1165-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10439-014-1165-7

Keywords

Navigation