Abstract

Purpose

Rupture of the flexor pollicis longus (FPL) and index flexor digitorum profundus (FDP2) tendons often occurs after locking plate fixation for distal radius fracture. This study aimed to determine the shortest tendon-radius distances of different hand positions.

Methods

Fifty-nine hands of 30 healthy volunteers were studied. Distances between the FPL or FDP2 and distal radius were calculated in six wrist positions: 30° palmar flexion, neutral, 30° dorsiflexion, 60° dorsiflexion, maximum dorsiflexion, and 40° ulnar deviation with three finger positions (full extension and flexion of fingers, full flexion of the thumb or index finger, and full extension of the other four fingers). The shortest distance between the FPL or FDP2 and distal radius was noted.

Results

The shortest distance between the FPL and distal radius was during maximum wrist dorsiflexion with isolated thumb flexion. The distance between the FDP2 and distal radius was shortest with all-finger flexion in 30° wrist dorsiflexion.

Conclusions

It is necessary to measure the distance between the FPL and distal radius in maximal wrist dorsiflexion with full flexion of the isolated thumb, as the shortest distance was observed with flexion of the isolated thumb. On the contrary, we recommend measuring the distance between the FDP2 and distal radius in 30° wrist dorsiflexion with flexion of all fingers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002;27:205–15.

    Article  PubMed  Google Scholar 

  2. Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013;14:227–34.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Cooney WP 3rd, Dobyns JH, Linscheid RL. Complications of Colles’ fractures. J Bone Jt Surg Am. 1980;62:613–9.

    Article  Google Scholar 

  4. Arora R, Lutz M, Hennerbichler A, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316–22.

    Article  Google Scholar 

  5. Casaletto JA, Machin D, Leung R, et al. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur. 2009;34:471–4.

    Article  CAS  Google Scholar 

  6. Duncan SF, Weiland AJ. Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. Am J Orthop (Belle Mead NJ). 2007;36:669–70.

    PubMed  Google Scholar 

  7. Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5:103–12.

    Article  CAS  PubMed  Google Scholar 

  8. Soong M, Earp BE, Bishop G, et al. Volar locking plate implant prominence and flexor tendon rupture. J Bone Jt Surg Am. 2011;93:328–35.

    Article  Google Scholar 

  9. Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am. 2008;33:164–7.

    Article  PubMed  Google Scholar 

  10. Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res. 2006;445:58–67.

    PubMed  Google Scholar 

  11. Tanaka Y, Aoki M, Izumi T, et al. Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg Am. 2011;36:1790–7.

    Article  PubMed  Google Scholar 

  12. Adham MN, Porembski M, Adham C. Flexor tendon problems after volar plate fixation of distal radius fractures. Hand (NY). 2009;4:406–9.

    Article  Google Scholar 

  13. Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27:1–6.

    CAS  PubMed  Google Scholar 

  14. Kitay A, Swanstrom M, Schreiber JJ, et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg Am. 2013;38:1091–6.

    Article  PubMed  Google Scholar 

  15. Valbuena SE, Cogswell LK, Baraziol R, et al. Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases. Chir Main. 2010;29:109–13.

    Article  CAS  PubMed  Google Scholar 

  16. Nanno M, Sawaizumi T, Kodera N, et al. Ultrasound evaluation of the transverse movement of the flexor pollicis longus tendon on the distal radius during wrist and finger motion in healthy volunteers. J Nippon Med Sch. 2015;82:220–8.

    Article  PubMed  Google Scholar 

  17. Cho CH, Lee KJ, Song KS, et al. Delayed rupture of flexor pollicis longus after volar plating for a distal radius fracture. Clin Orthop Surg. 2012;4:325–8.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Selvan DR, Machin DG, Perry D, et al. The role of fracture reduction and plate position in the aetiology of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. Hand (NY). 2015;10:497–502.

    Article  Google Scholar 

  19. Kara A, Celik H, Bankaoglu M, et al. Ultrasonic evaluation of the flexor pollicis longus tendon following volar plate fixation for distal radius fractures. J Hand Surg Am. 2016;41:374–80.

    Article  PubMed  Google Scholar 

  20. Mulders MAM, Walenkamp MMJ, Bos FJME, et al. Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review. Strategies Trauma Limb Reconstr. 2017;12:181–8.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Monaco NA, Dwyer CL, Ferikes AJ, et al. Hand surgeon reporting of tendon rupture following distal radius volar plating. Hand (NY). 2016;11:278–86.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kanta Imao.

Ethics declarations

Conflict of interest

Kanta Imao, Hitoshi Miwa, Kazutoshi Watanabe, Tsuyoshi Satoh, Atsuki Sano, and Naoto Endo declare that they have no conflicts of interest.

Human rights statements

This study was approved by the Institutional Review Board of our institution and all investigations were conducted in conformity with the ethical principles of research, as stated in the Declaration of Helsinki.

Informed consent

The subjects who volunteered for this study were informed about the design of the study, including any potential risks and discomfort, and all of them provided written informed consent.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Imao, K., Miwa, H., Watanabe, K. et al. Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people. J Med Ultrasonics 46, 353–359 (2019). https://doi.org/10.1007/s10396-019-00935-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10396-019-00935-5

Keywords

Navigation