Abstract
Purpose
Rupture of the flexor pollicis longus (FPL) and index flexor digitorum profundus (FDP2) tendons often occurs after locking plate fixation for distal radius fracture. This study aimed to determine the shortest tendon-radius distances of different hand positions.
Methods
Fifty-nine hands of 30 healthy volunteers were studied. Distances between the FPL or FDP2 and distal radius were calculated in six wrist positions: 30° palmar flexion, neutral, 30° dorsiflexion, 60° dorsiflexion, maximum dorsiflexion, and 40° ulnar deviation with three finger positions (full extension and flexion of fingers, full flexion of the thumb or index finger, and full extension of the other four fingers). The shortest distance between the FPL or FDP2 and distal radius was noted.
Results
The shortest distance between the FPL and distal radius was during maximum wrist dorsiflexion with isolated thumb flexion. The distance between the FDP2 and distal radius was shortest with all-finger flexion in 30° wrist dorsiflexion.
Conclusions
It is necessary to measure the distance between the FPL and distal radius in maximal wrist dorsiflexion with full flexion of the isolated thumb, as the shortest distance was observed with flexion of the isolated thumb. On the contrary, we recommend measuring the distance between the FDP2 and distal radius in 30° wrist dorsiflexion with flexion of all fingers.
Similar content being viewed by others
References
Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002;27:205–15.
Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013;14:227–34.
Cooney WP 3rd, Dobyns JH, Linscheid RL. Complications of Colles’ fractures. J Bone Jt Surg Am. 1980;62:613–9.
Arora R, Lutz M, Hennerbichler A, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316–22.
Casaletto JA, Machin D, Leung R, et al. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur. 2009;34:471–4.
Duncan SF, Weiland AJ. Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. Am J Orthop (Belle Mead NJ). 2007;36:669–70.
Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5:103–12.
Soong M, Earp BE, Bishop G, et al. Volar locking plate implant prominence and flexor tendon rupture. J Bone Jt Surg Am. 2011;93:328–35.
Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am. 2008;33:164–7.
Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res. 2006;445:58–67.
Tanaka Y, Aoki M, Izumi T, et al. Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg Am. 2011;36:1790–7.
Adham MN, Porembski M, Adham C. Flexor tendon problems after volar plate fixation of distal radius fractures. Hand (NY). 2009;4:406–9.
Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27:1–6.
Kitay A, Swanstrom M, Schreiber JJ, et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg Am. 2013;38:1091–6.
Valbuena SE, Cogswell LK, Baraziol R, et al. Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases. Chir Main. 2010;29:109–13.
Nanno M, Sawaizumi T, Kodera N, et al. Ultrasound evaluation of the transverse movement of the flexor pollicis longus tendon on the distal radius during wrist and finger motion in healthy volunteers. J Nippon Med Sch. 2015;82:220–8.
Cho CH, Lee KJ, Song KS, et al. Delayed rupture of flexor pollicis longus after volar plating for a distal radius fracture. Clin Orthop Surg. 2012;4:325–8.
Selvan DR, Machin DG, Perry D, et al. The role of fracture reduction and plate position in the aetiology of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. Hand (NY). 2015;10:497–502.
Kara A, Celik H, Bankaoglu M, et al. Ultrasonic evaluation of the flexor pollicis longus tendon following volar plate fixation for distal radius fractures. J Hand Surg Am. 2016;41:374–80.
Mulders MAM, Walenkamp MMJ, Bos FJME, et al. Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review. Strategies Trauma Limb Reconstr. 2017;12:181–8.
Monaco NA, Dwyer CL, Ferikes AJ, et al. Hand surgeon reporting of tendon rupture following distal radius volar plating. Hand (NY). 2016;11:278–86.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Kanta Imao, Hitoshi Miwa, Kazutoshi Watanabe, Tsuyoshi Satoh, Atsuki Sano, and Naoto Endo declare that they have no conflicts of interest.
Human rights statements
This study was approved by the Institutional Review Board of our institution and all investigations were conducted in conformity with the ethical principles of research, as stated in the Declaration of Helsinki.
Informed consent
The subjects who volunteered for this study were informed about the design of the study, including any potential risks and discomfort, and all of them provided written informed consent.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
About this article
Cite this article
Imao, K., Miwa, H., Watanabe, K. et al. Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people. J Med Ultrasonics 46, 353–359 (2019). https://doi.org/10.1007/s10396-019-00935-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10396-019-00935-5