Can Digital Enhancement Restore the Image Quality of Phosphor Plate-Based Radiographs Partially Damaged by Ambient Light?

  • Original Paper
  • Published:
Journal of Imaging Informatics in Medicine Aims and scope Submit manuscript

Abstract

To assess the effect of digital enhancement on the image quality of radiographs obtained with photostimulable phosphor (PSP) plates partially damaged by ambient light. Radiographs of an aluminum step wedge were obtained using the VistaScan and Express systems. Half of the PSP plates was exposed to ambient light for 0, 10, 30, 60, or 90 s before being scanned. The resulting radiographs were exported with and without digital enhancement. Metrics for brightness, contrast, and contrast-to-noise ratio (CNR) were derived, and the ratio of each metric between the exposed-to-light and non-exposed-to-light halves of the radiographs was calculated. The resulting ratios of the radiographs with digital enhancement were subtracted from those without digital enhancement and compared among each other. For the VistaScan system, digital enhancement partially restored brightness, contrast, and CNR. For the Express system, digital enhancement only restored CNR and not the impact of ambient light on brightness and contrast. Specifically, digital enhancement restored 23.48% of brightness for the VistaScan, while percentages below 1% were observed for the Express. Digital enhancement restored 53.25% of image contrast for the VistaScan and 5.79% for the Express; 40.71% of CNR was restored for the VistaScan, and 35% for the Express. Digital enhancement can partially restore the damage caused by ambient light on the brightness and contrast of PSP-based radiographs obtained with the VistaScan, as well as on CNR for the VistaScan and Express systems. The exposure of PSP plates to light can lead to unnecessary retakes and increased patient exposure to X-rays.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Wenzel A, Møystad A: Work flow with digital intraoral radiography: A systematic review. Acta Odontol Scand 68(2):106–14, 2010.

    Article  PubMed  Google Scholar 

  2. Pauwels R: History Of Dental Radiography: Evolution of 2D and 3D Imaging Modalities. Medical Physics International 8(1):235–77, 2020.

    Google Scholar 

  3. Caliskan A, Sumer AP: Definition, classification and retrospective analysis of photostimulable phosphor image artefacts and errors in intraoral dental radiography. Dentomaxillofacial Radiology 46(3), 2017.

  4. Ramamurthy R, Canning CF, Scheetz JP, Farman AG: Impact of ambient lighting intensity and duration on the signal-to-noise ratio of images from photostimulable phosphor plates processed using DenOptix® and ScanX® systems. Dentomaxillofacial Radiology 33(5):307–11, 2004.

    Article  CAS  PubMed  Google Scholar 

  5. Eskandarloo A, Yousefi A, Soheili S, Ghazikhanloo K, Amini P, Mohammadpoor H: Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates. Open Dent J 11(1):690–700, 2018.

    Article  Google Scholar 

  6. Elkhateeb SM, Aloyouny AY, Omer MMS, Mansour SM: Analysis of photostimulable phosphor image plate artifacts and their prevalence. World J Clin Cases 10(2):437–47, 2022.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Deniz Y, Kaya S: Determination and classification of intraoral phosphor storage plate artifacts and errors. Imaging Sci Dent 49(3):219–28, 2019.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Chiu HL, Lin SH, Chen CH, Wang WC, Chen JY, Chen YK, et al: Analysis of photostimulable phosphor plate image artifacts in an oral and maxillofacial radiology department. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology 106(5):749–56, 2008.

    Article  Google Scholar 

  9. Sampaio-Oliveira M, Marinho-Vieira LE, Wanderley VA, Ambrosano GMB, Pauwels R, Oliveira ML: How Does Ambient Light Affect the Image Quality of Phosphor Plate Digital Radiography? A Quantitative Analysis Using Contemporary Digital Radiographic Systems. Sensors, 2022.

  10. Sampaio-Oliveira M, Marinho-Vieira LE, Haiter-Neto F, Freitas DQ, Oliveira ML: Ambient light exposure of photostimulable phosphor plates: is there a safe limit for acceptable image quality? Dentomaxillofacial Radiology 20230174, 2023.

  11. Freire RG, Prata-Júnior AR, Pinho JNA, Takeshita WM: Diagnostic Accuracy of Caries and Periapical Lesions on a Monitor with and without DICOM-GSDF Calibration Under Different Ambient Light Conditions. J Digit Imaging 35:654-659, 2022.

  12. Lehmann TM, Troeltsch E, Spitzer K: Image processing and enhancement provided by commercial dental software programs. Dentomaxillofacial Radiology 31(4):264–72, 2002.

    Article  CAS  PubMed  Google Scholar 

  13. Yoshiura K, Welander U, Shi XQ, Li G, Kawazu T, Tatsumi M, et al: Conventional and predicted Perceptibility Curves for contrast-enhanced direct digital intraoral radiographs. Dentomaxillofacial Radiology 30(4):219–25, 2001.

    Article  CAS  PubMed  Google Scholar 

  14. Marinho-Vieira LE, Martins LAC, Freitas DQ, Haiter-Neto F, Oliveira ML: Revisiting dynamic range and image enhancement ability of contemporary digital radiographic systems. Dentomaxillof Radiol, 2021.

  15. Mah P, Buchanan A, Reeves TE: The Importance of the ANSI/ADA Standard for Digital Intraoral Radiographic Systems: A Pragmatic Approach to Quality Assurance. Oral Surg Oral Med Oral Pathol Oral Radiol 1–12, 2022.

  16. Thomas MA, Rowberg AH, Langer SG, Kim Y: Interactive Image Enhancement of CR and DR Images. J Digit Imaging 17(3):189-195, 2004.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Marinho-Vieira LE, Martins LAC, Freitas DQ, Haiter-Neto F, Oliveira ML: Revisiting dynamic range and image enhancement ability of contemporary digital radiographic systems—part 2: a subjective assessment. Dentomaxillofacial Radiology 52: 20220370, 2023.

    Article  PubMed  Google Scholar 

  18. Hammerstrom K, Aldrich J, Alves L, Ho A: Recognition and Prevention of Computed Radiography Image Artifacts. J Digit Imaging 19(3):226-239, 2006.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Souza Souza-Pinto G de, Nejaim Y, Gomes AF, Canteras FB, Freitas DQ, Haiter-Neto F: Evaluation of the Microstructure, chemical composition, and image quality of different PSP receptors. Braz Oral Res 36, 2022.

  20. Rueden CT, Schindelin J, Hiner MC, et al: ImageJ2: ImageJ for the next generation of scientific image data. BMC Bioinformatics 18:529, 2017.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Maciel ERC, Nascimento EHL, Gaêta-Araujo H, Pontual ML dos A, Pontual A dos A, Ramos-Perez FMM: Automatic exposure compensation in intraoral digital radiography: effect on the gray values of dental tissues. BMC Med Imaging 22(1):1–7, 2022.

    Article  Google Scholar 

  22. Yoshiura K, Nakayama E, Shimizu M, Goto TK, Chikui T, Kawazu T, et al: Effects of the automatic exposure compensation on the proximal caries diagnosis. Dentomaxillofacial Radiology 34(3):140–4, 2005.

    Article  CAS  PubMed  Google Scholar 

  23. Gomes IRL, Nascimento EHL, Gaêta-Araujo H, Anjos Pontual ML, Ramos-Perez FMM, dos Anjos Pontual A: Radiographic diagnosis of proximal caries is not affected by exposure protocols and presence of high-density material on systems with automatic exposure compensation. Oral Radiol 38(3):356–62, 2022.

    Article  PubMed  Google Scholar 

  24. Gaêta-Araujo H, Oliveira-Santos N, de Oliveira Reis L, Nascimento EHL, Oliveira-Santos C: Automatic exposure compensation of digital radiographic onéologies does not affect alveolar oné-level measurement. Oral Radiol 2022.

  25. Galvão NS, Nascimento EHL, Lima CAS, Freitas DQ, Haiter-Neto F, Oliveira ML: Can a high-density dental material affect the automatic exposure compensation of digital radiographic images? Dentomaxillofacial Radiology 48(3):2–7, 2019.

    Article  Google Scholar 

Download references

Funding

This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brazil (CAPES) – Finance code 001.

Author information

Authors and Affiliations

Authors

Contributions

Sampaio-Oliveira, M. He conceived, did the literature review, performed experimental activities, interpreted the data, drafted the manuscript and did the final revision of the paper. Vieira-Marinho, L.E. He performed experimental activities, evaluated and interpreted the data, drafted the manuscript and approved the paper. Barros-Costa, M. He conceived, did the literature review, drafted the manuscript and approved the paper. Oliveira, M.L. He conceived, did the literature review, performed experimental activities, interpreted the data, drafted the manuscript and did the final revision of the paper.

Corresponding author

Correspondence to Matheus Sampaio-Oliveira.

Ethics declarations

Ethics Approval

Not applicable.

Consent to Participate

Not applicable.

Consent to Publish

Not applicable.

Conflict of Interest

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

This manuscript has not been published and is not under consideration for publication elsewhere.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sampaio-Oliveira, M., Marinho-Vieira, L.E., Barros-Costa, M. et al. Can Digital Enhancement Restore the Image Quality of Phosphor Plate-Based Radiographs Partially Damaged by Ambient Light?. J Digit Imaging. Inform. med. 37, 145–150 (2024). https://doi.org/10.1007/s10278-023-00922-w

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-023-00922-w

Keywords

Navigation