Skip to main content
Log in

Influence of an iris-fixed phakic intraocular lens on the transport of nutrients by the aqueous humor

  • Original Paper
  • Published:
Biomechanics and Modeling in Mechanobiology Aims and scope Submit manuscript

Abstract

We study numerically the influence of an iris-fixed phakic intraocular lens (PIOL) on the transport of nutrients by the aqueous humor across a realistic model of the human eye. The Boussinesq equations are solved to calculate the velocity field both in the anterior and posterior chambers. The transport of the nutrient is modeled as that of a passive scalar convected by that velocity field and diffused by the concentration gradient. The nutrient is assumed to be adsorbed at the non-vascularized tissues, i.e., the crystalline lens and cornea endothelium. The adsorption rates at the crystalline and cornea endothelium are supposed to be proportional to the nutrient concentration there. The comparison between the results obtained with and without the PIOL allows us to quantify the influence of this device on the nutrient supply from the aqueous humor. The amount of nutrient adsorbed onto the crystalline is hardly affected by the presence of the PIOL in the anterior chamber, even though there is an iridotomy in this case. When the PIOL is implanted, the flux adsorbed onto the cornea endothelium increases up to around 32% for the highest value of the adsorption coefficient, and hardly varies for the other values of this parameter. This counterintuitive effect is explained by the efficient role played by the iridotomy in evacuating the nutrient from the posterior to the anterior chamber. Based on these results, one can estimate the variation of glucose available in the cornea endothelium after implanting the PIOL, and discuss potential effects on the cell metabolism. These simulations can be regarded as a first attempt to shed light on the mechanisms responsible for the supply of oxygen and glucose to eye avascular structures like the cornea endothelium and crystalline.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  • Abouali O, Modareszadeh A, Ghaffarieh A, Tu J (2012) Investigation of saccadic eye movement effects on the fluid dynamic in the anterior chamber. J Biomech Eng 134(021):002

    Google Scholar 

  • Bert RJ, Caruthers SD, Jara H, Krejza J, Melhem ER, Kolodny NH, Patz S, Freddo TF (2006) Demonstration of an anterior diffusional pathway for solutes in the normal human eye with high spatial resolution contrast-enhanced dynamic MR imaging. Investig Ophthalmol Vis Sci 47:5153–5162

    Article  Google Scholar 

  • Canning CR, Greaney MJ, Dewynne JN, Fitt AD (2002) Fluid flow in the anterior chamber of a human eye. IMA Int J Math Med Biol 19:31–60

    Article  MATH  Google Scholar 

  • Dvoriashyna M, Repetto R, Romano MR, Tweedy JH (2017) Aqueous humour flow in the posterior chamber of the eye and its modifications due to pupillary block and iridotomy. Math Med Biol 0:1–21

    Google Scholar 

  • Fernández-Vigo JI, Marcos AC, Agujetas R, Montanero JM, Sánchez-Guillén I, García-Feijóo J, Pandal-Blanco A, Fernández-Vigo JA, Macarro-Merino A (2018) Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens. PLoS ONE https://doi.org/10.1371/journal.pone.0202128

  • Fitt AD, Gonzalez G (2006) Fluid mechanics of the human eye: aqueous humour flow in the anterior chamber. Bull Math Biol 68:53–71

    Article  MathSciNet  MATH  Google Scholar 

  • Guell JL, Morral M, Gris O, Gaytan J, Sisquella M, Manero F (2007) Evaluation of verisyse and Artiflex phakic intraocular lenses during accommodation using visante optical coherence tomography. J Cataract Refract Surg 33:1398–1404

    Article  Google Scholar 

  • Guell JL, Morral M, Kook D, Kohnen T (2010) Phakic intraocular lenses part 1: historical overview, current models, selection criteria, and surgical techniques. J Cataract Refract Surg 36:1976–1993

    Article  Google Scholar 

  • Heys JJ, Barocas VH (2002) A boussinesq model of natural convection in the human eye and the formation of Krukenberg’s spindle. Ann Biomed Eng 30:392–401

    Article  Google Scholar 

  • Ismail Z, Fitt AD, Please CP (2013) A fluid mechanical explanation of the spontaneous reattachment of a previously detached descemet membrane. Math Med Biol 30:339–355

    Article  MathSciNet  MATH  Google Scholar 

  • Jonker SMR, Berendschot TTJM, Ronden AE, Saelens IEY, Nuijts NJCBRMMA (2018) Long-term endothelial cell loss in patients with artisan myopia and artisan toric phakic intraocular lenses: 5- and 10-year results. Ophthalmology 125:486–494

    Article  Google Scholar 

  • Kapnisis K, Doormaal MV, Ethier CR (2009) Modeling aqueous humor collection from the human eye. J Biomech 42:2454–2457

    Article  Google Scholar 

  • Kawamorita T, Uozato H, Shimizu K (2012) Fluid dynamics simulation of aqueous humour in a posterior chamber phakic intraocular lens with a central perforation. Graefes Arch Clin Exp Ophthalmol 250:935–939

    Article  Google Scholar 

  • Khongar PD, Pralits JO, Soleri P, Repetto R (2017) Aqueous flow in the presence of a perforated iris-fixated intraocular lens. Meccanica 52:577–586

    Article  MathSciNet  Google Scholar 

  • Khongar PD, Pralits JO, Cheng X, Pinsky P, Soleri P, Repetto R (2018) Effect of an iris-fixated intraocular lens on corneal metabolism: a numerical study. J Model Ophthalmol 2:97–101

    Google Scholar 

  • Kohnen T, Koo D, Morral M, Guell JL (2010) Phakic intraocular lenses part 2: results and complications. J Cataract Refract Surg 36:1976–1993

    Article  Google Scholar 

  • Larrea X, de Courten C, Feingold V, Burger J, Buchler P (2007) Oxygen and glucose distribution after intracorneal lens implantation. Optom Vis Sci 84:1074–1081

    Article  Google Scholar 

  • Oyaas J, Storro I, Svendsen H, Levine DW (1995) The effective diffusion coefficient and the distribution constant for small molecules in calcium–alginate gel beads. Biotechnol Bioeng 47:492–500

    Article  Google Scholar 

  • Repetto R, Pralits JO, Siggers JH, Soleri P (2015) Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow. Cornea 56:3061–3068

    Google Scholar 

  • Siggers JH, Ethier CR (2012) Fluid mechanics of the eye. Annu Rev Fluid Mech 44:347–372

    Article  MathSciNet  MATH  Google Scholar 

  • Tritton DJ (1988) Physical fluid dynamics. Oxford University Press, Oxford

    MATH  Google Scholar 

  • Tweedy JH, Pralits JO, Repetto R, Soleri P (2017) Flow in the anterior chamber of the eye with an implanted iris-fixated artificial lens. Math Med Biol 0:1–23

    MATH  Google Scholar 

  • Versteeg HK, Malalasekera W (2007) An introduction to computational fluid dynamics. Pearson Education Limited, London

    Google Scholar 

  • Villamarin A, Roy S, Hasballa R, Vardoulis O, Reymond P, Stergiopulos N (2012) 3D simulation of the aqueous flow in the human eye. Med Eng Phys 34:1462–1470

    Article  Google Scholar 

  • Wang W, Qian X, Song H, Zhang M, Liu Z (2016) Fluid and structure coupling analysis of the interaction between aqueous humor and iris. BioMed Eng OnLine 15:569–586

    Google Scholar 

  • Yamamoto Y, Uno T, Shisida K, Xue L, Shiraishi A, Zheng X, Ohashi Y (2006) Demonstration of aqueous streaming through a laser iridotomy window against the corneal endothelium. Arch Ophthalmol 124:387–393

    Article  Google Scholar 

  • Zurawski CA, McCarey BE, Schmidt FH (1989) Glucose consumption in cultured corneal cells. Curr Eye Res 8:349–355

    Article  Google Scholar 

Download references

Acknowledgements

Partial support from the Junta de Extremadura through Grant No. GR15014 (partially financed by FEDER funds) is gratefully acknowledged.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. M. Montanero.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Agujetas, R., Marcos, A.C., Fernández-Vigo, J.I. et al. Influence of an iris-fixed phakic intraocular lens on the transport of nutrients by the aqueous humor. Biomech Model Mechanobiol 18, 491–502 (2019). https://doi.org/10.1007/s10237-018-1099-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10237-018-1099-3

Keywords

Navigation