Biventricular support using a centrifugal pump in a 6 year old with fulminant myocarditis

  • Case Report
  • Artificial Heart (Clinical)
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

We experienced a case of ventricular assist with both a pulsatile-flow and a continuous-flow pump in a pediatric patient, and herein report the clinical course and characteristics of the pumps. A 6-year-old female was diagnosed with fulminant myocarditis and transferred to our hospital for mechanical support. After 12 days of extracorporeal membrane oxygenation, we implanted a left ventricular assist device (LVAD) and a right ventricular assist device (RVAD) using centrifugal Gyro pumps with a membrane oxygenator in a paracorporeal fashion. The membrane oxygenator was removed on postoperative day (POD) 4, and the patient was weaned from the respirator on POD 6. The LVAD was exchanged on POD 13 and 17, and the RVAD was exchanged on POD 14 because of thrombus formation inside the pumps. The RVAD was removed on POD 25. On POD 32, the patient experienced cerebral infarction and the centrifugal Gyro pump was switched to an extracorporeal pulsatile pump. No thromboembolic event occurred after pump conversion, although continuous administration of vasodilators was required to avoid hypertension. She underwent successfully heart transplantation in the USA after 8 months of ventricular support. A centrifugal pump is considered useful for pediatric patients, as pump flow and blood pressure can be relatively easily controlled in the postoperative acute phase compared with the pulsatile pump. However, special care should be taken to monitor for thrombus formation when support length becomes longer than 13 days, and a switch to a pulsatile pump should be considered once the hemodynamic status stabilizes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Homma A, Taenaka Y, Tatsumi E, et al. Development of a compact wearable pneumatic drive unit for a ventricular assist device. J Artif Organs. 2008;11:182–90.

    Article  PubMed  Google Scholar 

  2. Inoue T, Kitamura T, Torii S, et al. Five-week use of a monopivot centrifugal blood pump as a right ventricular assist device in severe dilated cardiomyopathy. J Artif Organs. 2014;17:95–8.

    Article  PubMed  Google Scholar 

  3. Takano T, Nakata K, Yoshikawa M, et al. Development of an antithrombogenic and antitraumatic blood pump: the Gyro C1E3. ASAIO J. 2000;46:123–7.

    Article  CAS  PubMed  Google Scholar 

  4. Martin J, Sarai K, Schindler M, van de Loo A, Yoshitake M, Beyersdorf F. MEDOS HIA-VAD biventricular assist device for bridge to recovery in fulminant myocarditis. Ann Thorac Surg. 1997;63:1145–6.

    Article  CAS  PubMed  Google Scholar 

  5. Wei-Che C, Marvin JS, Danny B. Thrombus formation patterns in the HeartMate II ventricular assist device: clinical observations can be predicted by numerical simulations. ASAIO J. 2014;60:237–40.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Hiromu Kehara or Tamaki Takano.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kehara, H., Takano, T., Terasaki, T. et al. Biventricular support using a centrifugal pump in a 6 year old with fulminant myocarditis. J Artif Organs 20, 166–169 (2017). https://doi.org/10.1007/s10047-016-0939-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-016-0939-0

Keywords

Navigation