Skip to main content

Advertisement

Log in

Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Objective

To explore the best entry point and trajectory of anterior cervical transpedicular screws in the lower cervical spine by radiological studies, and provide reference for clinical application.

Methods

Fifty patients were scanned by computed tomography and confirmed no obvious defect of the cervical spine. On horizontal axis, camber angle (α) and axial length (AL) were measured from C3 to C7. On sagittal view, the cranial or caudal angle (β) and sagittal length (SL) were also measured from C3 to C7. On the sagittal and horizontal planes vertebrae were respectively divided into four areas, ordered 1–4, on the anterior side of the pedicle. The areas and angles of pedicle intersect into the vertebral body were recorded. We inserted six anterior pedicle screws into the lower cervical spine of three patients by this technique.

Results

On transverse plane, camber angle (α) of C3–C5 increased gradually, while it decreased from C5 to C7. On sagittal view, C3 and C4 pedicles showed cranial tilting, while C5 to C7 were caudally tilted. AL and SL values increased gradually from C3 to C7. The number of the intersections of C3–C7 in each area was also different. Six pedicle screws of three cases were inserted into the lower cervical spine with proper placement and no complications.

Conclusion

Anterior transpedicular screw (ATPS) is a theoretically feasible option for internal fixation. The technique described in this paper was subsequently used in three patients without complication. Future improvement of ATPS insertion remains necessary for this technically demanding procedure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Aramomi M, Masaki Y, Koshizuka S, Kadota R, Okawa A, Koda M, Yamazaki M (2008) Anterior pedicle screw fixation for multi-level cervical corpectomy and spinal fusion. Acta Neurochir (Wien) 150:575–582

    Article  CAS  Google Scholar 

  2. Koller H, Hempfing A, Acosta F, Fox M, Scheiter A, Tauber M, Holz U, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites. Eur Spine J 17:523–538

    Article  PubMed  PubMed Central  Google Scholar 

  3. Koller H, Acosta F, Tauber M, Fox M, Martin H, Forstner R, Augat P, Penzkofer R, Pirich C, Kässmann H (2008) Cervical anterior transpedicular screw fixation (ATPS)—Part II. Accuracy of manual insertion and pull-out strength of ATPS. Eur Spine J 17:539–555

    Article  PubMed  PubMed Central  Google Scholar 

  4. Koller H, Hitzl W, Acosta F, Tauber M, Zenner J, Resch H, Yukawa Y, Meier O, Schmidt R, Mayer M (2009) In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III). Eur Spine J 18:1300–1313

    Article  PubMed  PubMed Central  Google Scholar 

  5. Yukawa Y, Kato F, Ito K, Nakashima H, Machino M (2009) Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique. Eur Spine J 18:911–916

    Article  PubMed  PubMed Central  Google Scholar 

  6. Marchesi DG (2009) Reviewer’s comment concerning “Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique” by Y. Yukawa et al. Eur Spine J 18:917. doi:10.1007/s00586-009-0949-1

    Article  PubMed  PubMed Central  Google Scholar 

  7. Zhao Lj Xu, Rm Jiang Wy, Ma Wh, Xu Nj HuY (2011) A new technique for anterior cervical pedicle screw implantation. Orthop Sur 3:193–198

    Article  Google Scholar 

  8. Ikenaga M, Mukaida M, Nagahara R, Yasunaga T, Ueda Y, Sohma Y (2012) Anterior cervical reconstruction with pedicle screws after a 4-level corpectomy. Spine 37:E927–E930

    Article  PubMed  Google Scholar 

  9. Fu M, Lin L, Kong X, Zhao W, Tang L, Li J, Ouyang J (2013) Construction and accuracy assessment of patient-specific biocompatible drill template for cervical anterior transpedicular screw (ATPS) insertion: an in vitro study. PLoS One 8:e53580

    Article  PubMed  CAS  PubMed Central  Google Scholar 

  10. Acosta FL Jr, Aryan HE, Chou D, Ames CP (2008) Long-term biomechanical stability and clinical improvement after extended multi-level corpectomy and circumferential reconstruction of the cervical spine using titanium mesh cages. J Spinal Disord Tech 21:165–174

    Article  PubMed  Google Scholar 

  11. Brazenor GA (2007) Comparison of multisegment anterior cervical fixation using bone strut graft versus a titanium rod and buttress prosthesis: analysis of outcome with long-term follow-up and interview by independent physician. Spine 32:63–71

    Article  PubMed  Google Scholar 

  12. Koller H, Hempfing A, Ferraris L, Maier O, Hitzl W, Metz-Stavenhagen P (2007) 4-and 5-level anterior fusions of the cervical spine: review of literature and clinical results. Eur Spine J 16:2055–2071

    Article  PubMed  PubMed Central  Google Scholar 

  13. Daubs MD (2005) Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating. Spine 30:1402–1406

    Article  PubMed  Google Scholar 

  14. Koller H, Schnidt R, Mayer M, Hitzl W, Zenner J, Midderhoff S, Graf N, Resch H, Wilke HJ (2010) The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping. Eur Spine J 19:2137–2148

    Article  PubMed  PubMed Central  Google Scholar 

  15. Epstein NE (2000) The value of anterior cervical plating in preventing vertebral fracture and graft extrusion after multi-level anterior cervical corpectomy with posterior wiring and fusion: indications, results, and complications. J Spinal Disord Tech 13:9–15

    Article  CAS  Google Scholar 

  16. Singh K, Vaccaro AR, Kim J, Lorenz EP, Lim T-H, An HS (2003) Biomechanical comparison of cervical spine reconstructive techniques after a multi-level corpectomy of the cervical spine. Spine 28:2352–2358

    Article  PubMed  Google Scholar 

Download references

Conflict of interest

No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Weihu Ma.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhao, L., Li, G., Liu, J. et al. Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine. Eur Spine J 23, 2175–2181 (2014). https://doi.org/10.1007/s00586-014-3473-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-014-3473-x

Keywords

Navigation