Skip to main content
Log in

The effect of esophagogastroduodenoscopy probe insertion on the intracuff pressure of airway devices in children during general anesthesia

  • Clinical Report
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

Given the size of the esophagogastroduodenoscopy (EGD) probe and the compressibility of the pediatric airway, the EGD probe may increase the intracuff pressure (IP) of an airway device. The current study evaluated IP changes during EGD examination under general anesthesia in pediatric patients. Following the induction of anesthesia, a laryngeal mask airway (LMA) or endotracheal tube (ETT) was placed without neuromuscular blockade. The IP was measured at baseline, during EGD probe insertion, while the EGD probe was in place, and after probe removal. The study cohort included 101 patients (mean age 11.3 years). The airway was secured with an LMA and an ETT in 88 and 13 patients, respectively. The IP increased from 27 ± 15 cmH2O at baseline to 34 ± 17 cmH2O during probe insertion (p < 0.001), remained at 33 ± 16 cmH2O while the probe was in place, and decreased to 26 ± 14 cmH2O after probe removal. The IP of the LMA or ETT increased during EGD probe insertion and remained elevated while the probe was in place. High IP may compromise mucosal perfusion resulting in a sore throat when using an LMA or the potential for airway damage if an ETT is used. Removal of air from the cuff and titration of the IP should be considered after EGD insertion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Brain AIJ. The laryngeal mask—a new concept in airway management. Br J Anaesth. 1983;55:801–5.

    Article  CAS  PubMed  Google Scholar 

  2. Nott MR, Noble PD, Parmar M. Reducing the incidence of sore throat with the laryngeal mask airway. Eur J Anaesthesiol. 1998;15:153–7.

    Article  CAS  PubMed  Google Scholar 

  3. Brimacombe J, Holyoake L, Keller C, Brimacombe N, Scully M, Barry J, Talbutt P, Sartain J, McMahon P. Pharyngolaryngeal, neck, and jaw discomfort after anesthesia with the face mask and laryngeal mask airway at high and low cuff volumes in males and females. Anesthesiology. 2000;93:26–31.

    Article  CAS  PubMed  Google Scholar 

  4. Burgard G, Mollhoff T, Prien T. The effect of laryngeal mask cuff pressure on postoperative sore throat incidence. J Clin Anesth. 1996;8:198–201.

    Article  CAS  PubMed  Google Scholar 

  5. Marjot R. Trauma to posterior pharyngeal wall caused by a laryngeal mask airway. Anaesthesia. 1991;46:589–90.

    Article  CAS  PubMed  Google Scholar 

  6. Wong JGL, Heaney M, Chambers NA, Erb TO, von Ungern-Sternberg BS. Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children. Pediatr Anesth. 2009;19:464–9.

    Article  Google Scholar 

  7. Inagawa G, Okuda K, Miwa T, Hiroki K. Higher airway seal does not imply adequate positioning of laryngeal mask airways in paediatric patients. Paediatr Anesth. 2002;12:322–6.

    Article  Google Scholar 

  8. Schloss B, Rice J, Tobias JD. The laryngeal mask in infants and children: what is the cuff pressure? Paediatr Anaesth. 2014;24:999–1004.

    Article  Google Scholar 

  9. Krishna SG, Ramesh AS, Jatana KR, Elmaraghy C, Merz M, Ruda J, Tobias JD. A technique to measure the intracuff pressure continuously: an in vivo demonstration of its accuracy. Paediatr Anaesth. 2014;24:999–1004.

    Article  PubMed  Google Scholar 

  10. Bick E, Bailes I, Patel A, Brain AI. Fewer sore throats and a better seal: why routine manometry for laryngeal mask airways must become the standard of care. Anaesthesia. 2014;69:1304–8.

    Article  CAS  PubMed  Google Scholar 

  11. Goldmann K, Dieterich J, Roessler M. Laryngopharyngeal mucosal injury after prolonged use of the ProSeal LMA in a porcine model: a pilot study. Can J Anesth. 2007;54:822–8.

    Article  PubMed  Google Scholar 

  12. Zhang J, Zhao Z, Chen Y, Zhang X. New insights into the mechanism of injury to the recurrent laryngeal nerve associated with the laryngeal mask airway. Med Sci Monit. 2010;16:HY7–9.

    PubMed  Google Scholar 

  13. Seet E, Yousaf F, Gupta S, Subramanyam R, Wong D, Chung F. Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events. Anesthesiology. 2010;112:652–7.

    Article  PubMed  Google Scholar 

  14. Rice MJ, Gravenstein NL, Brull SJ, Morey TE, Gravenstein N. Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure. J Clin Monit Comput. 2011;25:405–10.

    Article  PubMed  Google Scholar 

  15. Kamata M, Kako H, Ramesh AS, Krishna SG, Tobias JD. An in vitro and in vivo validation of a novel color-coded syringe device for measuring the intracuff pressure in cuffed endotracheal tubes. Int J Clin Exp Med. 2015;8:11356–9.

    PubMed  PubMed Central  Google Scholar 

  16. Martin DP, Bhalla T, Thung A, Tobias JD. Clinical evaluation of a novel LMA with a color-coded pressure gauge. Int J Pediatr Otorhinolaryngol. 2013;77:76–8.

    Article  PubMed  Google Scholar 

  17. Van Zundert T, Brimacombe J. Comparison of cuff-pressure changes in silicone and PVC laryngeal masks during nitrous oxide anaesthesia in spontaneously breathing children. Anaesth Intens Ther. 2012;44:63–70.

    Google Scholar 

  18. Tobias JD. Pediatric airway anatomy may not be what we thought: implications for clinical practice and the use of cuffed endotracheal tubes. Pediatr Anesth. 2015;25:9–19.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mumin Hakim.

Ethics declarations

Conflict of interest

All authors have no conflict of interest.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Balaban, O., Kamata, M., Hakim, M. et al. The effect of esophagogastroduodenoscopy probe insertion on the intracuff pressure of airway devices in children during general anesthesia. J Anesth 31, 278–281 (2017). https://doi.org/10.1007/s00540-016-2297-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-016-2297-8

Keywords

Navigation