Abstract
Purpose
To evaluate the biomechanical and tomographic outcomes of keratoconus patients up to four years after corneal crosslinking (CXL).
Methods
In this longitudinal retrospective-prospective single-center case series, the preoperative tomographic and biomechanical results from 200 keratoconus eyes of 161 patients undergoing CXL were compared to follow-up examinations at three-months, six-months, one-year, two-years, three-years, and four-years after CXL. Primary outcomes included the Corvis Biomechanical Factor (CBiF) and five biomechanical response parameters obtained from the Corvis ST. Tomographically, the Belin-Ambrósio deviation index (BAD-D) and the maximal keratometry (Kmax) measured by the Pentacam were analyzed. Additionally, Corvis E-staging, the thinnest corneal thickness (TCT), and the best-corrected visual acuity (BCVA) were obtained. Primary outcomes were compared using a paired t-test.
Results
The CBiF decreased significantly at the six-month (p < 0.001) and one-year (p < 0.001) follow-ups when compared to preoperative values. E-staging behaved accordingly to the CBiF. Within the two- to four-year follow-ups, the biomechanical outcomes showed no significant differences when compared to preoperative. Tomographically, the BAD-D increased significantly during the first year after CXL with a maximum at six-months (p < 0.001), while Kmax decreased significantly (p < 0.001) and continuously up to four years after CXL. The TCT was lower at all postoperative follow-up visits compared to preoperative, and the BCVA improved.
Conclusion
In the first year after CXL, there was a temporary progression in both the biomechanical CBiF and E-staging, as well as in the tomographic analysis. CXL contributes to the stabilization of both the tomographic and biomechanical properties of the cornea up to four years postoperatively.
Key message
What is known:
• While corneal crosslinking (CXL) is an effective procedure for halting disease progression in keratoconus patients, biomechanical in vivo measurements following CXL have shown conflicting results.
What is new:
• Biomechanical and tomographic severity indices CBiF, E-staging, and BAD-D show a temporary worsening within the first year after CXL.
• Post-CXL biomechanical stabilization can be observed up to four years postoperatively when analyzing the corneal response parameters and severity indices.
• Due to corneal thinning following standard protocol CXL, thickness-dependent parameters may not be optimal for the biomechanical and tomographic evaluation after CXL.
Similar content being viewed by others
Explore related subjects
Find the latest articles, discoveries, and news in related topics.Avoid common mistakes on your manuscript.
Introduction
Keratoconus is a progressive ectatic disease of the cornea with the highest prevalence during the second and third decades of life [1]. In terms of biomechanics, keratoconus is characterized by reduced corneal elasticity [2], which can be accurately quantified using the Corvis Scheimpflug technology (Corvis ST, Oculus, Wetzlar, Germany) by inducing corneal deformation with an air puff [3]. Recent research has shown that implementing this method improves the precision of diagnosing keratoconus when compared to relying only on tomographic measurements [4]. As the disease naturally progresses, the Corvis ST’s measured biomechanical response parameters deteriorate significantly [5, 6]. These findings suggest the applicability of Corvis ST in evaluating keratoconus progression.
The Corvis Biomechanical Index (CBI) combines various biomechanical response parameters into an index for detecting corneal ectasia [7]. However, due to its binary behavior, it is not suitable for assessing ectasia progression [8]. The newly introduced Corvis Biomechanical Factor (CBiF) is a linear factor based on the CBI that aims to better assess ectasia severity [8]. The CBiF can also be categorized into groups, leading to the E-staging. E-staging has been validated on data from 860 keratoconus corneas [9] to introduce a new standardized grading system, complementing the established tomographic ABCD staging.
Corneal crosslinking (CXL) has been established as a minimally invasive treatment option for progressive keratoconus eyes and was first developed in 2003 in Dresden, Germany [10,11,12]. CXL induces photochemical cross-links between proteoglycans and collagens, promoting stromal biochemical stiffness and reducing susceptibility to enzymatic digestion [13, 14]. Recent research has demonstrated its safety and effectiveness in halting progression and improving visual acuity [15]. However, more recent studies have yielded mixed results concerning in vivo biomechanical measurements following CXL. While multiple studies utilizing the previously introduced Ocular Response Analyzer (Reichert, Depew, USA) found no discernable differences in corneal biomechanics after CXL [10], a single study employing the more recently developed Corvis ST observed an unexpected progression in the biomechanical severity index CBiF six-months after CXL [16].
The purpose of this study was to further investigate the longitudinal in vivo stabilization in the biomechanical and tomographic properties of the cornea after CXL in keratoconus patients using Corvis ST and Pentacam measurements.
Materials and methods
This study analyzed 200 eyes from 161 patients longitudinally at the Keratoconus center of the Heidelberg University Hospital between 2021 and 2023. CXL was performed between June 2018 and December 2022 at Heidelberg University Hospital.
The study compared the preoperative tomographic and biomechanical evaluation available from 200 patients using Pentacam and Corvis ST with six follow-up examinations. Follow-up cohorts included 129 patients at three months (2.9 ± 0.8 months), 115 patients at six months (6.4 ± 1.4 months), 94 patients at one year (13.7 ± 2.6 months), 61 patients at two years (2.03 years ± 3.7 months), 33 patients at 3 years (2.95 years ± 3.5 months), and 15 patients at four years (4.03 years ± 4.4 months). Each postoperative cohort was compared to the respective group of eyes preoperatively.
CXL was performed according to the Dresden protocol [12]. First, the eye was anesthetized by topical anesthesia. Then, the central 8–10 mm zone of the epithelium was removed, and a solution comprising 0.1% riboflavin-5-phosphate and 20% dextran was applied to the de-epithelialized surface every two minutes for 30 min. The cornea was then exposed to 370 nm UVA with an irradiance of 3 mW/cm2 for 30 min, and the solution was reapplied at 2-minute intervals. After treatment, patients were prescribed ofloxacin antibiotic eye drops, dexamethasone eye drops, and artificial tears, and a soft bandage contact lens.
This study analyzed patients with diagnosed keratoconus and clinical disease progression undergoing CXL with acceptable quality of pre- and postoperative Pentacam and Corvis ST measurements. Keratoconus was diagnosed at a Pentacam BAD-D score of at least 2.6. As outlined by the German Federal Joint Committee of Federal Ministry of Health, the criteria for clinical progression of the disease included an increase in the maximum corneal refractive power by at least 1 diopter (D), an increase in astigmatism by at least 1 D, or a decrease in the base curve of the best-fitting contact lens by at least 0.1 mm [17]. Patients with any underlying conditions other than keratoconus were excluded from the study.
The primary outcome measures of the study included the CBiF as a biomechanical severity index, as previously described, and the corneal response parameters that form part of the CBiF (Table 1; Fig. 1). The CBiF-derived E-staging classification was included as a secondary endpoint due to its consistent behavior with the CBiF (Table 1). Analyzed response parameters included the deformation amplitude ratio (DA-ratio; the ratio of apical corneal deformation to the deformation at 2 mm away from the apex, Table 1; Fig. 1), the integrated radius (IR; the inverse concave radius at maximum deformation, Table 1; Fig. 1), Ambrósio relational thickness to the horizontal profile (ARTh; the ratio of the thinnest point of the cornea to its increase towards the periphery, Table 1), the stiffness parameter at first applanation (SP-A1; parameter of general rigidity of the cornea, Table 1), and the stress-strain index (SSI; overall stress–strain behavior of the corneal tissue, Table 1). Additionally, the Pentacam-derived Belin-Ambrósio deviation index (BAD-D) as a tomographic severity index as well as changes in the maximal anterior keratometry (Kmax) were selected as primary outcomes. Analysis of the thinnest corneal thickness (TCT) and the best-corrected visual acuity (BCVA) were included as secondary outcome parameters.
The data were analyzed utilizing SPSS Statistics, version 29 (IBM, Armonk, USA). Initially, outliers and normal distribution of data were assessed for comparing cases with less than 30 counts. This was performed utilizing exploratory data analysis and the Shapiro-Wilk test, under the assumption of normal distribution if p > 0.05. Outliers that have a standard deviation greater than three were removed from subsequent analysis. Preoperative measurements were compared to each follow-up time point using a two-tailed paired t-test for normally distributed data. For non-normally distributed data, the Wilcoxon signed-rank test was employed for comparison. To account for multiple comparisons, a Bonferroni correction was applied. Given eight primary outcome parameters and six comparisons per parameter, the resulting alpha was calculated as α < 0.00104 (rounded: α < 0.001). Patients who had missing follow-up data were excluded on a case-by-case basis for the defined follow-up time points. The necessary sample size for the main outcome measures was determined using d = 0.5 (estimated effect size), α = 0.00104 significance level, and power of p = 0.8 with a sample size of 74.
Results
Of the 161 patients included in this study, 122 were male (75.8%), and the ratio of right eyes (49.5%) was comparable to that of left eyes (50.5%). The mean age at CXL was 24.6 (± 7.4) years.
The CBiF significantly decreased at the six-month and one-year follow-ups in comparison to preoperative measurements (Fig. 2; Table 2). Subsequently, the CBiF measurements approached preoperative values once again after two years. Accordingly, the derived biomechanical E-staging showed a temporary increase at six-months and one-year follow-ups to then decrease to preoperative levels after 2 years and beyond (Table 2).
The DA-ratio demonstrated a decrease with statistically significant changes observed at four years-postoperatively (Table 2), while the IR did not exhibit statistically significant differences from the preoperative values after Bonferroni correction at any follow-up examination (Table 2). ARTh was significantly lower than the pre-CXL value at any follow-up point in time between three months and three years after CXL (Fig. 3; Table 2). The SP-A1 decreased until one year after the surgery and then consistently increased, though not significantly (Fig. 4; Table 2). The SSI saw a significant increase during the first year after CXL and then decreased to preoperative levels (Table 2).
The Kmax obtained from the Pentacam consistently and significantly decreased during every follow-up visit from six-months to four-years after CXL (Table 2). During the same follow-up period, BAD-D increased significantly from the three-months to one-year visit before returning to preoperative levels (Table 2). Also, the TCT significantly decreased after surgery during all follow-up visits when compared to preoperative measurements (Table 2). The mean BCVA improved over time, reaching − 0.16 logMAR at four years post-CXL (Table 2).
Discussion
This study aimed to determine whether biomechanical stabilization can be measured following CXL in accordance with the long-known tomographic stabilization. Within the first year after CXL, we observed a significant decrease in CBiF and an increase in E-Staging. Thereafter, the values remained consistent with preoperative levels from two to four years postoperatively. Biomechanical progression of keratoconus corresponds to a decrease in CBiF and an according increase in E-staging [9]. Therefore, the findings suggest a biomechanical progression of disease severity during the initial year after surgery followed by biomechanical stabilization. BAD-D, a tomographic index of ectasia detection, showed an increase over a similar period after CXL with significant changes at three-months, six-months, and one-year postoperatively. However, after two years and more, the CBiF, E-staging, and BAD-D showed values similar to those before surgery. Another study conducted at the Homburg Keratoconus Center on 22 corneas six months after CXL showed the same phenomenon with a biomechanical and tomographic increase in CBiF, E-Staging, and BAD-D, but no significant differences after one and two years [16]. These findings, which are similar to those of our study, suggest biomechanical stabilization after the first postoperative year.
Kmax, a parameter that is also used for disease classification [1], however, decreased continuously and immediately after CXL. The measurements exhibited an average decrease of 1.5 D after three months and 3.6 D after three years when compared to pre-treatment measurements. This suggests that actual disease progression may not occur within the initial year. Instead, there appears to be an ongoing stabilization of the cornea and a reduction in corneal protrusion immediately following CXL. The significant reduction in Kmax after CXL has been reported in multiple studies, accompanied by a slight improvement in visual acuity [18,19,20]. Contrastingly, a comprehensive meta-analysis of 11,529 eyes revealed a significant Kmax increase within one year amongst progressive keratoconus eyes left untreated [21]. This finding underlines the importance of CXL treatment to hinder keratoconus progression. Also, our study demonstrated an enhancement of BCVA as shown by an improvement of up to -0.16 logMAR after a four-year follow-up period.
The biomechanical severity parameter CBiF, the derived E-staging, and the tomographic BAD-D index are strongly influenced by corneal thickness measurements [8, 22]. In our study, the TCT significantly decreased at all postoperative follow-up time points. A systematic meta-analysis of six studies, including 261 eyes, also found a significant decrease in TCT after the standard CXL protocol as utilized in this study [20]. Other studies, using different CXL protocols found measurement artifacts due to stromal changes after CXL within the first postoperative year, leading to an underestimation of the corneal thickness measured by Scheimpflug technology [16, 23]. Our study suggests an actual decrease in corneal thickness as TCT measurements remained at the same lower level even four years after CXL. Nevertheless, the decrease in corneal thickness after CXL confounds the comparison of corneal response parameters and severity indices. A modified biomechanical index, such as that proposed in a publication by Steinberg et al. [24] without ARTh and therefore taking corneal thickness less into account, shows slightly reduced sensitivity in detecting keratoconus [25]. Nevertheless, it may still be a more accurate option in determining improvements in biomechanical properties after standard protocol CXL.
Regarding the biomechanical response parameters used to calculate CBiF and E-staging, the parameter most affected by TCT is ARTh [7]. It is expected for ARTh to be significantly decreased at every post-operative follow-up visit up to three years post-CXL, given that TCT was significantly lower at each visit. These results correspond with those of Flockerzi et al., who similarly documented a notable decrease in ARTh during every subsequent assessment within a two-year observation period [16].
The SP-A1 is an interesting corneal response parameter for assessing corneal biomechanics due to its direct relation to corneal stiffness, with greater values corresponding to heightened stiffness [7]. The present study documented a decrease in SP-A1 following surgery, with its lowest value at six-months after CXL. Thereafter, the SP-A1 showed continuously increasing values at each follow-up visit up to four years post-CXL. Other studies that investigated this parameter showed similar results. Two recent studies respectively examining 21 corneas two years after accelerated CXL have shown a significant increase in SP-A1 [16, 26]. Additionally, another study found a significant increase in SP-A1 on 67 corneas after just six months [27]. The initial decrease in corneal stiffness observed in this study may be attributed to its correlation with corneal thickness [28]. Other treatment protocols as used in the above-mentioned studies may have less effect on corneal thickness [20], leading to more pronounced changes in SP-A1. However, the comparable trend of a continuous increase in this parameter supports the notion of a gradual postoperative stiffening of the cornea up to four years after CXL. While IR also showed no significant differences from pre- to postoperative, this can also be interpreted as a stabilization due to its deterioration in untreated progressive corneas [5].
The DA-ratio is another biomechanical parameter indicative of corneal stiffness. In our study, the parameter consistently decreased and reached statistically significant changes four years after surgery, supporting the hypothesis of a gradual and continuous corneal stiffening post-CXL. This argument stems from lower parameter values indicating higher resistance to deformation [7]. Two other studies also reported a significantly decreased DA-ratio among 21 corneas two years after CXL [26] and 67 corneas six months after CXL [27].
The SSI is a newly developed parameter for assessing the biomechanical behavior of the cornea in vivo, with no correlation to corneal thickness or intraocular pressure [29]. Higher SSI values indicate greater tissue stiffness [29]. Interestingly, the initial two follow-ups at the three-month and six-month post-CXL periods recorded higher SSI values, while no significant alterations to preoperative measurements were observed thereafter. This suggests an immediate increase in corneal stiffness and stabilization with no significant difference after this period. The initial increase in SSI contrasts with the first-year changes observed in CBiF, E-staging, BAD-D, and SP-A1, possibly due to its independence from corneal thickness. While the SSI has been reported to deteriorate in untreated progressive eyes [5, 6], comparable values to preoperatively support biomechanical stabilization. However, further studies are needed to investigate this parameter in the context of CXL.
A limitation of this study is the high rate of participants who dropped out during later follow-up periods. Consequently, the two- to four-year results should be interpreted with caution as the initially calculated effect size was not met at these visits. Furthermore, a very strict significance level was imposed due to the multiple comparisons. However, this study analyzed the biomechanical stabilization over a long follow-up compared to other studies [16, 26, 27] and offers valuable insights into corneal stiffening up to four years after CXL. Further research comparing our data to a healthy control group or keratoconus patients without disease progression may be beneficial in enhancing the interpretation of our analysis.
In conclusion, this study provides empirical evidence of biomechanical in vivo stabilization up to four years post-CXL. The biomechanical severity index CBiF as well as certain biomechanical response parameters such as the ARTh appear to be affected by corneal thinning following standard protocol CXL and, hence, may not be optimal for evaluating the efficacy of CXL at least in the early postoperative period. However, the biomechanical results of the corneal response parameters SP-A1, DA-ratio, IR, and SSI showed no deterioration when compared to preoperatively. The equalization of CBiF to preoperative levels one year after CXL up to four years after CXL, despite the continued lower TCT measurements, suggests long-term corneal biomechanical stabilization.
References
Santodomingo-Rubido J, Carracedo G, Suzaki A, Villa-Collar C, Vincent SJ, Wolffsohn JS (2022) Keratoconus: an updated review. Cont Lens Anterior Eye 45:101559. https://doi.org/10.1016/j.clae.2021.101559
Lohmuller R, Bohringer D, Maier PC, Ross AK, Schlunck G, Reinhard T, Lang SJ (2023) Keratoconus: biomechanics ex vivo. Klin Monbl Augenheilkd 240:774–778. https://doi.org/10.1055/a-2062-3633
Ren S, Xu L, Fan Q, Gu Y, Yang K (2021) Accuracy of new Corvis ST parameters for detecting subclinical and clinical keratoconus eyes in a Chinese population. Sci Rep 11:4962. https://doi.org/10.1038/s41598-021-84370-y
Esporcatte LPG, Salomao MQ, Lopes BT, Sena N, Ferreira E, Filho J, Machado AP, Ambrosio R Jr. (2023) Biomechanics in Keratoconus diagnosis. Curr Eye Res 48:130–136. https://doi.org/10.1080/02713683.2022.2041042
Padmanabhan P, Lopes BT, Eliasy A, Abass A, Elsheikh A (2022) In vivo Biomechanical Changes Associated with Keratoconus Progression. Curr Eye Res 47:982–986. https://doi.org/10.1080/02713683.2022.2058020
Lopes BT, Padmanabhan P, Eliasy A, Zhang H, Abass A, Elsheikh A (2022) In vivo Assessment of Localised corneal biomechanical deterioration with Keratoconus Progression. Front Bioeng Biotechnol 10:812507. https://doi.org/10.3389/fbioe.2022.812507
Vinciguerra R, Ambrosio R Jr., Elsheikh A, Roberts CJ, Lopes B, Morenghi E, Azzolini C, Vinciguerra P (2016) Detection of Keratoconus with a New Biomechanical Index. J Refract Surg 32:803–810. https://doi.org/10.3928/1081597X-20160629-01
Flockerzi E, Vinciguerra R, Belin MW, Vinciguerra P, Ambrosio R Jr., Seitz B (2022) Correlation of the Corvis Biomechanical Factor with tomographic parameters in keratoconus. J Cataract Refract Surg 48:215–221. https://doi.org/10.1097/j.jcrs.0000000000000740
Flockerzi E, Vinciguerra R, Belin MW, Vinciguerra P, Ambrosio R Jr., Seitz B (2022) Combined biomechanical and tomographic keratoconus staging: adding a biomechanical parameter to the ABCD keratoconus staging system. Acta Ophthalmol 100:e1135–e1142. https://doi.org/10.1111/aos.15044
Sorkin N, Varssano D (2014) Corneal collagen crosslinking: a systematic review. Ophthalmologica 232:10–27. https://doi.org/10.1159/000357979
Spoerl E, Seiler T (1999) Techniques for stiffening the cornea. J Refract Surg 15:711–713. https://doi.org/10.3928/1081-597X-19991101-21
Wollensak G, Spoerl E, Seiler T (2003) Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am J Ophthalmol 135:620–627. https://doi.org/10.1016/s0002-9394(02)02220-1
Kohlhaas M, Spoerl E, Schilde T, Unger G, Wittig C, Pillunat LE (2006) Biomechanical evidence of the distribution of cross-links in corneas treated with riboflavin and ultraviolet a light. J Cataract Refract Surg 32:279–283. https://doi.org/10.1016/j.jcrs.2005.12.092
Spoerl E, Wollensak G, Seiler T (2004) Increased resistance of crosslinked cornea against enzymatic digestion. Curr Eye Res 29:35–40. https://doi.org/10.1080/02713680490513182
Meiri Z, Keren S, Rosenblatt A, Sarig T, Shenhav L, Varssano D (2016) Efficacy of corneal collagen cross-linking for the treatment of Keratoconus: a systematic review and Meta-analysis. Cornea 35:417–428. https://doi.org/10.1097/ICO.0000000000000723
Flockerzi E, Xanthopoulou K, Daas L, Feld S, Langenbucher A, Seitz B (2022) Evaluation of dynamic corneal response parameters and the Biomechanical E-Staging after accelerated corneal cross-linking in Keratoconus. Asia Pac J Ophthalmol (Phila) 11:514–520. https://doi.org/10.1097/APO.0000000000000580
Hecken J (2018) Tragende Gründe zum Beschluss des Gemeinsamen Bundesausschusses über eine Änderung der Richtlinie Methoden vertragsärztliche Versorgung: UV-Vernetzung mit Riboflavin bei Keratokonus. https://www.g-ba.de/downloads/40-268-5137/2018-07-19_MVV-RL_UV-Vernetzung-Riboflavin-Keratokonus_TrG.pdf accessed 14 december 2023
Greenstein SA, Hersh PS (2021) Corneal crosslinking for Progressive Keratoconus and corneal ectasia: Summary of US Multicenter and Subgroup Clinical trials. Transl Vis Sci Technol 10:13. https://doi.org/10.1167/tvst.10.5.13
Saleh S, Koo EB, Lambert SR, Manche EE (2022) Outcomes after corneal crosslinking for Keratoconus in Children and Young adults. Cornea 41:408–416. https://doi.org/10.1097/ICO.0000000000002730
Kobashi H, Hieda O, Itoi M, Kamiya K, Kato N, Shimazaki J, Tsubota K, The Keratoconus Study Group Of J (2021) Corneal cross-linking for paediatric Keratoconus: a systematic review and Meta-analysis. J Clin Med 10. https://doi.org/10.3390/jcm10122626
Ferdi AC, Nguyen V, Gore DM, Allan BD, Rozema JJ, Watson SL (2019) Keratoconus Natural progression: a systematic review and Meta-analysis of 11 529 eyes. Ophthalmology 126:935–945. https://doi.org/10.1016/j.ophtha.2019.02.029
Ghiasian L, Abdolalizadeh P, Hadavandkhani A, Eshaghi A, Hadi Y, Nadjafi-Semnani F (2022) Comparing Pentacam HR Screening indices in different normal corneal thicknesses among refractive surgery candidates. J Curr Ophthalmol 34:200–207. https://doi.org/10.4103/joco.joco_249_21
Caporossi A, Mazzotta C, Baiocchi S, Caporossi T (2010) Long-term results of riboflavin ultraviolet a corneal collagen cross-linking for keratoconus in Italy: the Siena eye cross study. Am J Ophthalmol 149:585–593. https://doi.org/10.1016/j.ajo.2009.10.021
Steinberg J, Amirabadi NE, Frings A, Mehlan J, Katz T, Linke SJ (2017) Keratoconus Screening with dynamic biomechanical in vivo scheimpflug analyses: a proof-of-Concept Study. J Refract Surg 33:773–778. https://doi.org/10.3928/1081597X-20170807-02
Vinciguerra R, Ambrosio R Jr., Roberts CJ, Elsheikh A, Lopes B, Vinciguerra P (2018) Should the Corvis Biomechanical Index (CBI) include corneal thickness parameters? J Refract Surg 34:213–216. https://doi.org/10.3928/1081597X-20180103-01
Hashemi H, Ambrosio R Jr., Vinciguerra R, Vinciguerra P, Roberts CJ, Ghaffari R, Asgari S (2019) Two-year changes in corneal stiffness parameters after accelerated corneal cross-linking. J Biomech 93:209–212. https://doi.org/10.1016/j.jbiomech.2019.06.011
Jabbarvand M, Moravvej Z, Shahraki K, Hashemian H, Ghasemi H, Berijani S, Amiri Z, Jamali A (2021) Corneal biomechanical outcome of collagen cross-linking in keratoconic patients evaluated by Corvis ST. Eur J Ophthalmol 31:1577–1583. https://doi.org/10.1177/1120672120944798
Zhao Y, Shen Y, Yan Z, Tian M, Zhao J, Zhou X (2019) Relationship among corneal stiffness, thickness, and Biomechanical parameters measured by Corvis ST, Pentacam and ORA in Keratoconus. Front Physiol 10:740. https://doi.org/10.3389/fphys.2019.00740
Eliasy A, Chen KJ, Vinciguerra R, Lopes BT, Abass A, Vinciguerra P, Ambrosio R Jr., Roberts CJ, Elsheikh A (2019) Determination of corneal Biomechanical Behavior in-vivo for healthy eyes using CorVis ST Tonometry: stress-strain index. Front Bioeng Biotechnol 7:105. https://doi.org/10.3389/fbioe.2019.00105
Funding
Open Access funding enabled and organized by Projekt DEAL.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the Institutional Ethics Committee from Ruprecht-Karls University of Heidelberg (trial registration number: S-621/2021) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Conflict of interest
R. Khoramnia reports grants, personal fees, and nonfinancial support from Johnson & Johnson Vision, Alcon Laboratories, Hoya Corp., Kowa Co., Ltd., Oculentis GmbH/Teleon, Physiol S.A., Sifi Medtech Srl, and Rayner Intraocular Lenses Ltd.; grants and personal fees from Oculus Optikgeräte GmbH, Carl Zeiss Meditec AG, and Ophtec BV; and grants from Acufocus Inc. outside the submitted work. G.U. Auffarth reports lecture fees and research grants from Johnson & Johnson Vision, Alcon Laboratories, Carl Zeiss Meditec AG, Hoya Corp., Kowa Co., Ltd., Oculentis GmbH/Teleon, Physiol S.A., Rayner Intraocular Lenses Ltd., Oculus Optikgeräte GmbH, Ophthec BV, Santen, Sifi Medtech Srl, Acufocus Inc., Novartis, Ursapharm and Biotech; nonfinancial support from Rheacell, Contamac, Cristalens, Croma, EyeYon, Hanita, and VSY outside the submitted work. V. A. Augustin reports research grants from Eye Yon and Kowa Co. outside the submitted work. The remaining authors have no relevant financial or non-financial interests to disclose.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Felter, E., Khoramnia, R., Friedrich, M. et al. Biomechanical changes following corneal crosslinking in keratoconus patients. Graefes Arch Clin Exp Ophthalmol (2024). https://doi.org/10.1007/s00417-024-06549-z
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00417-024-06549-z