Abstract
Purpose
To evaluate residual astigmatism following correction with toric implantable collamer lens (TICL) (group I) over a period of 4 years and compare with the change of astigmatism in spectacle wearers (group II).
Methods
Groups I (86 cases implanted with TICL [EVO + Visian ICL, Staar Surgical, Nidau, Switzeland], preop refractive error [sphere and cylinder] − 22.25 DS to − 1.00 DS and − 5.50 DC to − 1.00 DC) and II (80 cases initial refractive error [sphere and cylinder] − 18.00 DS to 0.00 DS and − 7.00 DC to − 1.00 DC) were reviewed annually. Refractive and tomography data were subjected to vector analysis to determine surgically induced astigmatism (SIA), angle of error [Δθ° = angle of target-induced astigmatism (TIA) − angle of SIA], and ΔC [TIA-SIA powers] and total corneal astigmatism (TCA) in group I and induced change in astigmatism (ICA) in group II.
Results
In group I, on all occasions, SIA correlated with TIA (p < 0.05); differences between SIA and TIA means were insignificant and changes in TCA were not correlated with ΔC. Mean (± sd, 95% CI) residual astigmatic powers (RA) in attending group I cases (1–4 years) were − 0.40 DC (0.58, − 0.52 to − 0.28), − 0.40 DC (0.59, − 0.52 to − 0.27), − 0.41 DC (0.58, − 0.54 to − 0.28), and − 0.61 DC (0.74, − 0.82 to − 0.40). In group II, the corresponding ICA powers were − 0.47 DC (0.53, − 0.61 to − 0.32), − 0.49 DC (0.48, − 0.69 to − 0.29), − 0.60 DC (0.40, − 0.76 to − 0.44), and − 0.86 DC (0.71, − 1.19 to − 0.52). Differences between RA and ICA were not significant. Of the group I cases presenting at 1–4 years postop, 23, 18, 16, and 28 had RA powers ≤ − 0.75 DC. Of these 12, 10, 6, and 16 were associated with Δθ° > 5° (ΔC − 0.50 to 0 DC) and 5, 1, 4, and 4 were related to ΔC (Δθ° < 5°).
Conclusion
The development of astigmatism after TICL implantation is on par with the natural change in astigmatism in untreated cases. In about 50% of TICL cases presenting with astigmatism ≤ − 0.75 DC, the residual astigmatism could be neutralized by realigning the TICL.
Similar content being viewed by others
Data availability
Available on request.
Code availability
Not applicable.
References
Brown DC, Ziémba SL, Collamer IOL FDA Study Group (2001) Collamer intraocular lens: clinical results from the US FDA core study. J Cataract Refract Surg. 27(6):833–40. https://doi.org/10.1016/s0886-3350(01)00785-4
Sanders DR, Doney K, Poco M (2004) ICL in treatment of Myopia Study Group. United States Food and Drug Administration clinical trial of the implantable collamer lens (ICL) for moderate to high myopia: three-year follow-up. Ophthalmology 111:1683–1692. https://doi.org/10.1016/j.ophtha.2004.03.026
Park SC, Kwun YK, Chung ES, Ahn K, Chung TY (2009) Postoperative astigmatism and axis stability after implantation of the STAAR Toric Implantable Collamer Lens. J Refract Surg 25(5):403–409. https://doi.org/10.3928/1081597X-20090422-01
Sanders DR, Schneider D, Martin R, Brown D, Dulaney D, Vukich J, Slade S, Schallhorn S (2007) Toric Implantable Collamer Lens for moderate to high myopic astigmatism. Ophthalmology 114(1):54–61. https://doi.org/10.1016/j.ophtha.2006.08.049
Schallhorn S, Tanzer D, Sanders DR, Sanders ML (2007) Randomized prospective comparison of visian toric implantable collamer lens and conventional photorefractive keratectomy for moderate to high myopic astigmatism. J Refract Surg 23(9):853–867
Chang J, Lau S (2009) Toric Implantable Collamer Lens for high myopic astigmatic Asian eyes. Ophthalmology 116(12):2340–2347. https://doi.org/10.1016/j.ophtha.2009.04.053
Hashem AN, El Danasoury AM, Anwar HM (2009) Axis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism. J Refract Surg 25(10 Suppl):S939-943. https://doi.org/10.3928/1081597X-20090915-08
Elies D, Alonso T, Puig J, Gris O, Güell JL, Coret A (2010) Visian toric implantable collamer lens for correction of compound myopic astigmatism. J Refract Surg 26(4):251–258. https://doi.org/10.3928/1081597X-20100218-02
Sheng XL, Rong WN, Jia Q, Liu YN, Zhuang WJ, Gu Q, Sun Y, Pan B, Zhu DJ (2012) Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the toric implantable collamer lens for high myopic astigmatism. Int J Ophthalmol 5(4):459–465. https://doi.org/10.3980/j.issn.2222-3959.2012.04.10
Lee D, Lee SJ, Kyung H (2015) Rotational stability after toric implantable collamer lens implantation. Journal of the Korean Ophthalmological Society 56(4):477–484. https://doi.org/10.3341/jkos.2015.56.4.477
Ammar H, Anbar M, Abdellah MM (2016) Comparison of visian toric collamer lens and toric acrylic intraocular lens implantation for the treatment of myopia with astigmatism. Clin Ophthalmol 29(11):105–114. https://doi.org/10.2147/OPTH.S122442
Emerah S (2020) Evaluation of axis alignment and refractive results of toric phakic IOL using image-guided system. Int J Ophthalmol 13(4):667–670. https://doi.org/10.18240/ijo.2020.04.21
Sari ES, Pinero DP, Kubaloglu A, Evcili PS, Koytak A, Kutlutürk I, Ozerturk Y (2013) Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up. Graefes Arch Clin Exp Ophthalmol 251(5):1413–1422. https://doi.org/10.1007/s00417-012-2172-8
Hyun J, Lim DH, Eo DR, Hwang S, Chung ES, Chung TY (2017) A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL): V4 versus V4c. PLoS One 12(8):e0183335. https://doi.org/10.1371/journal.pone.0183335
Alfonso JF, Lisa C, Abdelhamid A, Fernandes P, Jorge J, Montés-Micó R (2010) Three-year follow-up of subjective vault following myopic implantable collamer lens implantation. Graefes Arch Clin Exp Ophthalmol 248(12):1827–1835. https://doi.org/10.1007/s00417-010-1322-0
Lu Y, Yang N, Li X, Kong J (2017) Four-year follow-up of the changes in anterior segment after phakic collamer lens implantation. Am J Ophthalmol 178:140–149. https://doi.org/10.1016/j.ajo.2017.03.020
Řeháková T, Veliká V, Rozsíval P, Jirásková N (2019) Correction of myopia and myopic astigmatism by implantation of a phakic posterior chamber implantable collamer lens. Cesk Slov Oftalmol. 74(4):147–152. English. https://doi.org/10.31348/2018/1/4-4-2018.
Igarahasi A, Shimizu K, Kamiya K (2014) Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia. Am J Ophthalmol 157:532–539. https://doi.org/10.1016/j.ajo.2013.11.006
Lisa C, Naveiras M, Alfonso-Bartolozzi B, Belda-Salmerón L, Montés-Micó R, Alfonso JF (2015) Posterior chamber collagen copolymer phakic intraocular lens with a central hole to correct myopia: one-year follow-up. J Refract Surg 41:1153–1159. https://doi.org/10.1016/j.jcrs.2014.10.030
Moya T, Javaloy J, Montés-Micó R, Beltrán J, Muñoz G, Montalbán R (2015) Implantable collamer lens for myopia: assessment 12 years after implantation. J Refract Surg 31:548–556. https://doi.org/10.3928/1081597X-20150727-05
Kamiya K, Shimizu K, Igarashi A, Kitazawa Y, Kojima T, Nakamura T, Oka Y, Matsumoto R (2018) Posterior chamber phakic intraocular lens implantation: comparative, multicentre study in 351 eyes with low-to-moderate or high myopia. Br J Ophthalmol 102:177–181. https://doi.org/10.1136/bjophthalmol-2017-310164
Goukon H, Kamiya K, Shimizu K, Igarashi A (2017) Comparison of corneal endothelial cell density and morphology after posterior chamber phakic intraocular lens implantation with and without central hole. Br J Ophthalmol 101:1461–1465. https://doi.org/10.1136/bjophthalmol-2016-309363
van der Heijde GL (1989) Some optical aspects of implantation of an IOL in a myopic eye. Eur J Implant Refract Surg 1:245–248
Fechner PU, van der Heijde GL, Worst JGF (1989) The correction of myopia by lens implantation into phakic eyes. Am J Ophthalmol 107:659–663. https://doi.org/10.1016/0002-9394(89)90264-x
Kohnen T, Kook D, Morral M, Güell JL (2010) Phakic intraocular lenses: part 2: results and complications. J Cataract Refract Surg 36:2168–2194. https://doi.org/10.1016/j.jcrs.2010.10.007
Kamiya K, Shimizu K, Igarashi A, Hikita F, Komatsu M (2009) Four-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia. Arch Ophthalmol 127:845–850. https://doi.org/10.1001/archophthalmol.2009.67
Alpins N (2001) Astigmatism analysis by the Alpins method. J Cataract Refract Surg 27:31–49. https://doi.org/10.1016/s0886-3350(00)00798-7
Abulafia A, Koch DD, Holladay JT, Wang L, Hill WE (2018) Editorial. Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: suggested terminology, analysis, and standards for outcome reports. J Cataract Refract Surg 44:1169–1174. https://doi.org/10.1016/j.jcrs.2018.07.027
Jennings JAM, Charman WN (1973) A comparison of errors in some methods of subjective refraction. The Ophthalmic Optician 13(8):11–18
Rosenfield M, Chiu NN (1995) Repeatability of subjective and objective refraction. Optom Vis Sci 8:577–579
Leinonen LE, Laatikainen L (2006) Repeatability (test-retest variability) of refractive error measurement in clinical settings. Acta Ophthalmol 84:532–536. https://doi.org/10.1111/j.1600-0420.2006.00695.x
Villegas EA, Alcón E, Artal P (2014) Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg 40(1):13–19. https://doi.org/10.1016/j.jcrs.2013.09.010
Liang GL, Wu J, Shi JT, Liu J, He FY, Xu W (2014) Implantable collamer lens versus iris-fixed phakic intraocular lens implantation to correct myopia: a meta-analysis. PLoS One 9(8):e104649. https://doi.org/10.1371/journal.pone.0104649
Fernandes P, González-Méijome JM, Madrid-Costa D, Ferrer-Blasco T, Jorge J, Montés-Micó R (2011) Implantable collamer posterior chamber intraocular lenses: a review of potential complications. J Refract Surg 27(10):765–776. https://doi.org/10.3928/1081597X-20110617-01
Kocová H, Vlková E, Michalcová L, Rybárová N, Motyka O (2017) Incidence of cataract following implantation of a posterior-chamber phakic lens ICL (Implantable Collamer Lens) - long-term results. Cesk Slov Oftalmol. 73(3):87–93. English
Kaur M, Shaikh F, Falera R, Titiyal JS (2017) Optimizing outcomes with toric intraocular lenses. Indian J Ophthalmol 65(12):1301–1313. https://doi.org/10.4103/ijo.IJO_810_17
Author information
Authors and Affiliations
Contributions
Maja Bohac: conception and design, investigation, data curation, formal analysis, methodology, project administration, validation, visualization, writing the manuscript.
Alma Biscevic: conception and design, investigation, data curation, formal analysis, methodology, project administration, validation, visualization.
Ivan Gabric: conception and design, formal analysis, interpretation of data, methodology, critical revision.
Kresimir Gabric: conception and design, methodology, supervision, validation.
Violeta Shijakova: conception and design, data curation and interpretation, project administration, critical revision.
Sudi Patel: conception and design, analysis and interpretation of data, writing the manuscript, critical revision.
All authors approved the version to be published and agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Corresponding author
Ethics declarations
Ethics approval
The study was performed under the tenets of the Helsinki agreement and approved by the Ethics committee of the Specialty Eye Hospital Svjetlost.
Consent to participate
All patients signed an informed consent for the procedure performed.
Consent for publication
The author transfers to Springer the nonexclusive publication rights and she warrants that her contribution is original and that she has full power to make this grant. The author signs for and accepts responsibility for releasing this material on behalf of any and all co-authors. This transfer of publication rights covers the nonexclusive right to reproduce and distribute the article, including reprints, translations, photographic reproductions, microform, electronic form (offline, online), or any other reproductions of similar nature.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Bohac, M., Biscevic, A., Gabric, I. et al. A critical evaluation of longitudinal changes of astigmatism following implantation of toric implantable collamer lens (TICL): a comparison between treated and untreated cases over 4 years. Graefes Arch Clin Exp Ophthalmol 260, 1377–1386 (2022). https://doi.org/10.1007/s00417-021-05449-w
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00417-021-05449-w