Abstract
The ability to analyze blunt-force trauma is crucial for deciphering valuable clues concerning mechanisms of injury and as evidence for medico-legal investigations. The use of alternate light sources (ALS) has been studied over the past decade, and is proposed to outperform conventional white light (CWL) during bruise assessments. In response to the growing interest of the technology worldwide, a systematic review of the literature was conducted according to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) to address the ability of ALS to detect and visualize bruising. From an initial 4055 records identified, ten studies met the eligibly criteria and were selected for this review. Evaluation also included a novel framework, referred to as SPICOT, to further systematically assess both scientific evidence and risk of bias in forensic literature. Analysis reveals that narrowband wavelengths within in the infrared or ultraviolet spectral ranges do not significantly outperform CWL in visualizing or detecting bruising. However, wavelengths within the visible spectrum, particularly 415 nm combined with longpass or bandpass yellow filters, are more effective. However, the majority of selected studies only address the sensitivity of ALS, and therefore, results may only be considered valid when the location of a bruise is known. Further investigation is required to understand the specificity of ALS, in particular how the use of topical cosmetic products, previous wounds/scar-tissue, tattoos, moles and freckles may affect detection. The ethical concern regarding the interpretation of enhanced visualized trauma should also be considered in prospect discussions prior to implementing ALS into routine practice. Nevertheless, this review finds that narrowband ALS within the visible spectrum demonstrates potential for improved injury documentation, outperforming CWL in the detection and visualization of bruising.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Bruises serve as markers of blunt-force trauma and may yield valuable clues into the mechanisms of injury [1]. An accurate and comprehensive bruise analysis is therefore warranted in cases of suspected abuse and assault. However, despite its forensic significance, the task of identifying and documenting bruises remains difficult due to a myriad of factors influencing their visibility. This includes, the degree of inflicted trauma, the dynamic and distinct process of healing [2] as well as the diversity of varying skin tones [3,4,5,6], that may result in the absence of visible bruising or the presence of bruises deem too minor to document during medico-legal examinations [7]. To overcome this challenge, a growing volume of research has explored the possibility of using alternate light sources (ALS) to enhance blunt-force trauma documentation [8].
Light can be categorized by its wavelength into the visible light spectrum (VLS), narrowband light between 400 and 700 nm, and the invisible light spectrum, comprising both ultraviolet (UV) and infrared (IR) light composed of wavelengths below 400 nm and above 700 nm, respectively (Fig. 1). ALS refers to the use of single and narrowband wavelengths within the full spectra for illumination and are used by law-enforcement worldwide to detect biological traces such as blood and semen, as well as chemical agents including gunshot residue [9,10,11,12,13,14,15]. When photons of particular wavelengths are absorbed, they induce electron transitions to higher energy orbits. Fluorescence occurs when excited electrons return to lower energy states, releasing energy in the form of photons with a lower energy and longer wavelength compared to the excitation light, referred to as Stoke’s Shift [9]. Consequently, emitted light is not visible to the naked eye, requiring the use of specific longpass or bandpass filters that block the return of the excitation light [16].
The electromagnetic spectrum. UV wavelengths, with values under 400 nm, exhibit greater energy compared to IR wavelengths, which reside above 700 nm on the spectrum’s opposite end. Longer wavelengths with lower energy can penetrate tissues more deeply than their shorter counterparts. The VLS spans from 400 nm to 700 nm, encompassing the vibrant colors of violet, blue, green, yellow, orange, and red
The hallmark of bruising is the discoloration that occurs as a consequence of ruptured vessels in the dermal layer of the skin. Visualizing the extravasated blood using normal or conventional white light (CWL) is challenging however, as the majority of light is both reflected by the skin’s surface and absorbed by melanin, secreted by melanocytes located between the surface and dermal layer [17]. This becomes particularly prevalent in darker skin where higher concentrations of melanocytes persist. On the other hand, emission of a single or narrowband wavelength may penetrate the skin and be absorbed specifically by hemoglobin and its associated breakdown products [18, 19]. This can be perceived as darkened regions on the skin when viewed through distinct filters [20]. Hence, employing ALS to visualize bruising may circumvent the obstacles presented by white light reflection and melanin concentrations.
In the age of evidence-based medicine, forensic methods must demonstrate their scientific rigor to ensure that accurate and reliable results are presented during legal proceedings. Consequently, examining the specificity and sensitivity of ALS to understand its effectiveness in discerning bruising from non-bruising, and detecting all bruising, is paramount. Bruise detection and bruise visibility are related concepts, but refer to different aspects of bruise sensitivity. Bruise detection is the process of identifying the presence of a bruise, while bruise visibility relates to how apparent or noticeable a bruise is once it has been detected. Specificity on the other hand refers to the ability to differentiate bruising from non-bruising. In pursuit of such knowledge, we focus here answering the question: does the detection and visualization by ALS of blunt-force trauma outperform CWL approaches in medico-legal contexts?
Methodology
Research question
A systematic review of the literature was conducted according to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) framework [21, 22]. The objective was to address the research question: “does detection and visualization of bruising by ALS outperform CWL approaches in medico-legal contexts?”
Search strategy and data sources
Relevant search terms were defined following consultation with an information specialist. Search queries are described in Table 1, and were constructed using the Boolean operators “AND” and “OR”. Records were collected from the databases of PubMed, Medline, and CINAHL, from inception to 30 April 2024. Supplementary sources were also extracted from citations lists of selected studies if deemed relevant.
Eligibility criteria
Inclusion and exclusion criteria were defined according to the research question that defined the population, intervention, comparison and outcome (PICO). Inclusion criteria consisted of English language records published in peer-reviewed journals. Studies needed to include a sample population that was of a human model, with living individuals that presented bruising from blunt-force trauma (including bite marks). The source of the trauma was not defined. Studies needed to exhibit an intervention consisting of an ALS (UV, narrowband visible light or IR) with a CWL comparison. Records also needed to include a discussion regarding outcomes, including a statement summarizing the preferred method for visualizing or detecting a bruising. Investigations using ALS to identify biological samples outside the body such as sperm, fingerprints or gunshot reside were excluded.
Selection of evidence
Data was imported into Microsoft Excel (Office 2019) for further selection and cataloging. Following removal of duplications, records were screened for relevance in a systematic and sequential manner, by title, abstract and full-text. Relevance of each study was assessed by two independent researchers. Disagreements were solved during consensus discussions. Only articles detailing an original study were selected for full-text screening and editorials/commentaries, conferences proceedings, case reports and technical protocols were excluded.
Study evaluation
Studies were evaluated using SPICOT (Study design, study population, intervention/exposure, controls/comparisons/index test, outcome and timespan) to systematically assess both scientific evidence and risk of bias the forensic literature (Supplementary 1). Screening using SPICOT was conducted to ensure that only studies fulfilling established scientific criteria were selected to form conclusions in this review.
For the risk of bias assessment in SPICOT, a predetermined set of criteria within a study’s population, control/comparison, exposure and assessment were analyzed. Within the population criterion, we examined if the population had firstly been defined, secondly if bruising was controlled for or validated, and thirdly the investigated sample size. Similarly, for controls/comparison, we examined if a negative bruise assessment had been performed, and if a CWL control had been conducted, alongside identifying sample size. For intervetion, the ALS exposure had to be defined and for the assessment criterion, we examined not only if procedures had been defined, but also if multiple independent assessors were employed and if blinded assessments had occurred.
All studies were assessed in each category described to determine a combined level of evidence and risk of bias (categorized as low (0–9 points), medium (10–16 points), or high (17–20 points)). This scoring process was carried out by a sole researcher. Those scoring SPICOT-low and SPICOT-medium, were additionally assessed by a separate independent researcher. If variations in scores impacted SPICOT classification, consensus discussions were held to decide final score. Studies that both researchers identified as having a SPICOT-low were excluded.
Data extraction
A summary of the information extracted from studies is described in Table 2. In brief, this included publication type and details regarding date of publication. The data source was also extracted in addition to an identification of the study design by the researcher. Information regarding study population was extracted, including age and skin color, as well as bruise infliction method and location on body. Population size (n) was also extracted. The ALS wavelength was noted alongside the specific band/longpass filter used for detection. Assessment timepoint(s) and metrics were extracted, as well as the methods used for processing of data/analysis, alongside information relating to the relevance of controls and control group size (n). Descriptions regarding the effectiveness in detecting and visualizing bruising using both ALS and CWL was recorded.
Ethical consideration
This study involves the analysis of existing published data and therefore did not require ethical approval.
Results
Study selection
The search strategy yielded a total of 4055 studies, comprising 1883 from PubMed, 1840 from Medline and 332 from CINAHL. After removal of duplicates (2061) and systematic screening of titles and abstracts, 32 full-text articles were assessed for eligibility and 15 were further considered for SPICOT evaluation. Five studies were assessed as SPICOT-low [7, 23,24,25,26] and therefore excluded, resulting in a total of ten studies being selected for this review [6, 8, 20, 27,28,29,30,31,32,33]. The selection process is detailed in Fig. 2 according to PRISMA guidelines [22].
Risk of bias assessment
Risk of bias assessment is represented in Table 3. The selected studies all had defined populations, with the majority exhibiting samples > 20 individuals. Only one study did not use an inflicted bruising control or consider a validation method to confirm bruising. While all studies conducted a CWL control, 40% did not consider a negative bruise examination/validation. In terms of assessment strategies, 60% of studies conducted blinded analysis of bruising with multiple assessors. All studies defined their ALS exposure.
Characteristics of individual sources of evidence
Characteristics of the individual studies are summarized in Table 4. Analysis demonstrates that 10% of the studies exhibited a correlation study design, 40% had a causal-effect design, and the remaining 50% had an experimental setup. The eight studies employing a controlled inflicted bruising, consisted of either a dropped metal object onto the forearm of an individual, or by paintballs fired at the upper arm. In both cases, the velocity and impact zone were controlled. The remaining studies examined bruises within clinical settings, where timing (assessment post-trauma), bruise site (area on body) and impact details (velocity) could not be controlled for. Regarding the ALS narrowband used, the majority investigated single wavelengths within the UV and VLS, with one study exploring IR and UV wavelengths in comparison to other imaging modalities in CWL, and another study examined only IR in comparison to CWL imaging techniques. It is worth noting that only one study analyzed fluorescence while the remaining examined absorption under ALS. Diagnostic measurement was considered as: sensitivity – examination was only conducted on injuries in known locations; specificity – examination was conducted on both bruising and non-bruising sites. Based on this criterion, only one study considered specificity in their diagnostic measurement. Four studies reported bruise assessments using descriptors for visibility (e.g., clear, no, bare), two measured bruise size, one, anatomical location and another, the contrast between bruised and non-bruised skin. The remaining studies utilized a novel bruise visibility scale (BVS) and absorption visibility scale (AVS). Two studies examined bruising at a single time point, whereas the remaining eight spanned a period from 30 min post-bruise infliction to four weeks post-bruising. Two studies did not report or consider their sample population skin color, with half of the remaining eight exhibiting representation across six skin categories: “very light,” “light,” “intermediate,” “tan,” “brown,” and “dark”. The remaining 50% had predominantly “white”/“light” sample populations.
Results of individual sources of evidence
Table 5 summarizes findings presented in the selected studies. Collectively, the data indicate that among the ten selected studies, eight suggest that ALS is more effective than CWL in detecting and visualizing bruising, particularity mentioning its usefulness during early stages of bruise formation. Analysis reveals that wavelength filter combinations within the IR or UV spectral ranges do not outperform CWL, while narrowband wavelengths within the VLS, specifically 415 nm combined with either longpass or bandpass yellow-cut filters do.
Various studies [6, 8, 29, 32, 33] have explored the effectiveness of different single wavelength and filter combinations in detecting and enhancing bruise visibility compared to CWL. Limmen et al. [20] demonstrated that narrowband wavelengths between 400 and 470 nm significantly increased visibility compared to CWL, reporting an improved visibility in 52% of bruises that were initially deemed “barely visible” under CWL. These finding are consistent with the known absorption peaks of oxyhemoglobin (415 nm), de-oxygemoglobin (430 nm), and bilirubin (460 nm) [18, 19, 34]. Despite the declining frequency of visible observations with increasing skin pigmentation [8], wavelengths of 415 nm and 450 nm (paired with a yellow filter) exhibited the highest rates of bruise detection across all skin categories (415 nm: 11.2%; 450 nm: 11.1%), with 415 nm/yellow filter being the only combination that outperformed CWL in cases where skin colour was classed as “brown” or “dark” [6].
Although the ability to detect bruises decreases over time, results from the selected literature implies that bruising may be detected and visualized sooner following trauma with an ALS than with CWL [28,29,30,31]. Scafide et al. [31] identified bruising in 98% of cases within the initial three days post-trauma when employing 415 nm /yellow filter combination, whereas only 24% were detectable under CWL. Although the use of IR was proposed to be marginally superior to CWL during bruise formation in Black et al. [28], no statistically significant difference was observed between the methods. Findings are similar to that reported by Trefan et al. [27], though IR imaging was noted to produce smaller bruise sizes compared to CWL imaging.
The time frame for when ALS is more effective than CWL appears to be constrained at both ends, as studies suggest that CWL is better within the initial 30 min post-trauma [30, 31] and at earliest after two days post-trauma [30]. Though further investigations are needed, as findings reported are contrasting. For instance, Nijs et al. [30] found no significance between bruise visibility under ALS and CWL seven days post-trauma using 415 nm/yellow filter combinations while findings by Scafide et al. [32] noted that the 450 nm /yellow filter consistently outperformed CWL in detecting bruises within a 4 week period post-injury. However, differences in analysis may account for these differences as Nijs et al. [30] examined bruise visibility and Scafide et al. [32] bruise detection. Nevertheless, the proposed time frame may explain why ALS performed better than CWL in the study by Limmen et al. [20], where the average time between injury and ALS examination was 2.6 days.
The quantification of the visual degree of bruising conducted initially by Nijs et al. [30]. expressed between one (very bad) and ten (excellent), circumvents subjective visibility descriptors such as “obvious,” “clear,” “distinct,” “faded,” and “faint”. Scafide et al. [33] further developed this quantitative BVS, and suggesting that visibility should not be measured using the same scale for both CWL and ALS, since CWL includes the entire VLS and ALS only a narrow bandwidth. This may explain why bruises of low contrast, i.e. difficult to distinguish from surrounding skin, are more diffuse and less distinctive using IR and UV light [27]. Scafide et al. [33] therefore proposed a tailored BVS, referred to as the AVS when using ALS. When scales were compared, a greater bruise size was associated with higher visibility using either scale but that greater contrast in color or lightness was associated with higher BVS values alone [33]. Future studies should therefore consider the use of the AVS to provide more unity between investigations and comparable results.
Discussion
Unlike traditional forensic medicine that often relies on singular observations during autopsies, research within clinical forensic medicine benefits from being able to employ experimental study designs akin to those used in clinical trials. For instance, the majority of research investigating the effectiveness of ALS compared to CWL, involve randomized study populations, controlled bruise inflictions, and examination strategies using multiple contact points with blinded assessments.
From an initial search encompassing 4055 records, ten articles were identified to meet the specified inclusion and exclusion criteria post screening. Data extracted from the selected studies indicate that employing a 415 nm ALS combined with a yellow bandpass/longpass filter outperforms CWL in both bruise detection and visualization. While research in this area is restricted to a single study, findings demonstrate that the 415 nm/yellow filter combination also performs better than CWL and other narrowband wavelengths when assessing bruises in individuals with darker skin tones. However, this is provided the location of a trauma is known. Only a single study compared the ability of ALS to discern bruising from non-bruising, with results indicating that caution is warranted if examining fluorescence [29].
Previous studies have raised concerns regarding the specificity of ALS in detecting bruising [29, 35, 36]. The chart review by Holbrook and Jackson [7] showcased an impressive capability of ALS to detect bruises, identifying bruising in 98% of reported cases of strangulation, wherein 93% displayed no apparent injuries under CWL examination. This highlighted the use of ALS as a compelling tool for bruise detection, with the findings presented in legal proceedings [29]. However, the absence of controls specifically addressing bruise validity limits the results [7], as ascertaining what the authors’ identified as bruising is perplexing, since neither hemoglobin nor bilirubin exhibit significant fluorescent properties, and skin may fluorescence from factors other than bruising [17, 37]. Further investigations by Lombardi et al. [29] revealed that a CWL had a significantly greater specificity compared to fluorescence under ALS. Authors concluded that the diagnostic reliability of fluorescence under ALS remains uncertain if bruising cannot be validated, and further investigation examining the specificity of absorption is necessary. Debatably, Lombardi et al. [29] presentation of results by pooling wavelengths into a single sensitivity and specificity measure may be deemed inaccurate, as data from individual wavelengths do indeed exhibit higher sensitivity and specificity than CWL at various time points during the course of the experiment. Nevertheless, to alleviate problems associated with the lack of specificity in routine casework, ALS examinations should always be conducted in conjunction with CWL. This approach facilitates the evaluation of additional factors including pain, swelling, and the patient’s history of physical trauma to validate bruising.
Moreover, common over-the-counter topical products have demonstrated to generate greater ALS absorption when applied on light or medium skin tones compared to those with dark skin [37]. One makeup product consistently absorbed wavelengths between 310 and 535 nm in 80.9% of observations, and sunscreen (SPF30) absorbed significant light in 7% of cases. However, the remaining twelve products tested absorbed light in less than 1% of observations [37]. In a follow up study evaluating the effectiveness of three different topical product removal methods (soap and water, isopropyl alcohol swab, makeup removal wipe), four out of 14 products continued to exhibit significant absorption after removal [38]. No differences were noted between removal methods, highlighting that further research exploring the specificity of ALS and topical products post-inflicted trauma is warranted, alongside studies questions relating to how previous wounds/scar-tissue, tattoos, moles (including Mongolian spots) and freckles affect specificity. Thus, live ALS examination is therefore advocated to ensure suspected bruises can be washed to mitigate any unknown risk of interference [17]. Relying solely on ALS and CWL photography for bruise examination may overlook such elements.
Research on the ability of ALS to detect and visualize bruising across varying skin pigmentations is sparse. Although Lombardi et al. [29] disclosed that subjects were recruited regardless of race, only a small fraction exhibited dark skin pigmentation. The majority of the selected studies examined white/light populations. Of the ten studies reviewed, only the study series by Scafide et al. [6, 8, 32, 33] has addressed equal representation across skin categories determined by spectrophotometry. Scafide et al. [6] found that the wavelengths 415 nm and 450 nm, when paired with yellow-cut filters, were consistently better than other wavelengths at bruise detection for all tested skin categories. UV was less effective than CWL in identifying bruising across darker skin tones, except in individuals with very light skin, which may be due to melanin’s peak absorption wavelength around 335 nm [39, 40]. On the other hand, hemoglobin’s absorption spectra typically exhibits a sharp peak at around 415 nm (dependent on oxygenation level) and most probably accounts for why the wavelength was most effective [19]. Although Scafide et al. [32] initially advocated the use of yellow or orange filters, subsequent analysis using the developed AVS [33], determined that yellow alone was more effective [6]. Although results are in contrast to findings by Sully et al. [41] who suggest that longer wavelengths combined with orange filters are superior in dark skin, the use of a goat model with topically applied melanin could have resulted in higher pigment concentrations than that of human skin and may account for differences observed. Additional studies are needed for further confirmation.
Furthermore, it should be noted that all ten studies examined bruising on extremities. The location of injury has demonstrated to have a significant impact on bruising manifestation and by extension, detection and visibility. For example, the presence of loose subcutaneous tissues increases the risk of blood extravasation, leading to more pronounced bruising around specific regions such as the eye compared to the hand [1]. Subpopulations such as children and the elderly are more susceptible to bruising than young and physically fit individuals [34]. Additionally, individuals with conditions like hypertension, diabetes, and coagulation disorders are also more prone to exhibit different bruising patterns. Certain steroids have been observed to affect the rate of bruising development [42], and common medications such as anticoagulants can influence both the formation and resolution of bruises, which can manifest immediately, or take longer to develop [1, 34]. Hence, results from the selected studies are constrained by the possibility that the data may not extend to injuries sustained on the torso, face/neck, and genital regions. In practice, medical history may not always be considered prior an ALS assessment, and further studies are warranted to address such injury mechanisms and locations.
While ALS research has primarily focused on assessing the technology’s capacity to detect and visualize bruising for enhanced documentation of blunt-force trauma for legal purposes, an ethical dilemma emerges regarding a potential for overinterpretation of injury mechanisms. Although this discussion falls beyond the scope of this review, it warrants attention for future research to contemplate how enhanced visualization of bruises could inadvertently mislead legal professionals lacking medical and technical expertise. For instance, an increased visualization could result in an overestimation of injury severity or mechanism of injury, leading to erroneous judgments and unjust outcomes in legal proceedings. Hence, forensic and legal experts must exercise caution and thoroughness when interpreting and communicating ALS bruising evidence, particularly if relying solely on photographs.
Limitations of study
This review faces several limitations stemming from predetermined constraints dictated by the nature of systematic reviews and the narrow research question. While studies examining both specificity and sensitivity were included, the strict criteria resulted in a restricted pool of eligible studies. Consequently, only ten studies were deemed suitable, with only a single addressing specificity. This selection bias should be considered when interpreting the review’s outcomes, as while ALS outperforms CWL in bruise detection and visualization, studies have only considered the technology where bruise location is known. In cases where a bruise cannot be validated either by CWL or other methods, ALS should be used with caution, as studies do not sufficiently address specificity.
It should also be mentioned that five out of the ten selected studies were authored by the same research team, four of which were derived from the same primary dataset. Such pseudoreplication of findings, albeit presented from varying perspectives, may be argued to pose a limitation to this review and the wider research domain.
Conclusions
Conclusively, results from this systematic review indicate that ALS is more effective than CWL in detecting and visualizing bruising. Analysis reveals that wavelength filter combinations within the IR or UV spectral ranges do not outperform CWL, while wavelengths within the VLS, specifically 415 nm with either long/bandpass yellow filters do, across differing categories of skin color. These results however, only address the sensitivity of ALS, and can only be considered valid when the location of a bruise is known.
Although only a limited number of studies exist, most employ experimental designs that deliver high-quality data due to their randomization and controlled bruise infliction processes. Further investigations of comparable rigor are imperative, ideally conducted by a greater diversity of research teams. These studies should delve into questions concerning specificity, encompassing the impacts of topical products, a range of injury mechanisms, and repercussions on different anatomical regions. Moreover, the ethical quandary surrounding potential pitfalls stemming from the overinterpretation of visually enhanced data will demand careful consideration in the future, particularly as digital imaging methods become more autonomic.
References
Langlois NEI, Gresham GA (1991) The ageing of bruises: a review and study of the colour changes with time. Forensic Sci Int 50:227–238. https://doi.org/10.1016/0379-0738(91)90154-B
Sharman LS, Fitzgerald R, Douglas H (2023) Medical evidence assisting non-fatal strangulation prosecution: a scoping review. BMJ Open 13:e072077. https://doi.org/10.1136/bmjopen-2023-072077
Scafide KRN, Sheridan DJ, Campbell J et al (2013) Evaluating change in bruise colorimetry and the effect of subject characteristics over time. Forensic Sci Med Pathol 9:367–376. https://doi.org/10.1007/s12024-013-9452-4
Thavarajah D, Vanezis P, Perrett D (2012) Assessment of bruise age on dark-skinned individuals using tristimulus colorimetry. Med Sci Law 52:6–11. https://doi.org/10.1258/msl.2011.011038
Vanezis P (2001) Interpreting bruises at necropsy. J Clin Pathol 54:348–355. https://doi.org/10.1136/jcp.54.5.348
Scafide KN, Downing NR, Kutahyalioglu NS et al (2022) Predicting alternate light absorption in areas of trauma based on degree of skin pigmentation: not all wavelengths are equal. Forensic Sci Int 339:111410. https://doi.org/10.1016/j.forsciint.2022.111410
Holbrook DS, Jackson MC (2013) Use of an alternative light source to assess strangulation victims. J Forensic Nurs 9:140–145. https://doi.org/10.1097/JFN.0b013e31829beb1e
Downing NR, Scafide KN, Ali Z, Hayat MJ (2024) Visibility of inflicted bruises by alternate light: results of a randomized controlled trial. J Forensic Sci 69:880–887. https://doi.org/10.1111/1556-4029.15481
West MH, Barsley RE, Hall JE et al (1992) The detection and documentation of trace wound patterns by use of an alternative light source. J Forensic Sci 37:1480–1488
Wawryk J, Odell M (2005) Fluorescent identification of biological and other stains on skin by the use of alternative light sources. J Clin Forensic Med 12:296–301. https://doi.org/10.1016/j.jcfm.2005.03.005
Eldredge K, Huggins E, Pugh LC (2012) Alternate light sources in sexual assault examinations: an evidence-based practice project. J Forensic Nurs 8:39–44. https://doi.org/10.1111/j.1939-3938.2011.01128.x
Mackenzie B, Jenny C (2014) The use of alternate light sources in the clinical evaluation of child abuse and sexual assault. Pediatr Emerg Care 30:207–210. https://doi.org/10.1097/PEC.0000000000000094
Husak J (2022) Noninvasive, visual examination for the presence of gunshot residue on human skin. J Forensic Sci 67:1191–1197. https://doi.org/10.1111/1556-4029.14954
Schulz MM, Wehner F, Wehner H-D (2007) The Use of a tunable light source (Mini-crimescope MCS-400, SPEX Forensics) in dissecting microscopic detection of cryptic epithelial particles. J Forensic Sci 52:879–883. https://doi.org/10.1111/j.1556-4029.2007.00489.x
Rathore PS, Kumar S (2021) Identification of different body fluids through novel deep blue autofluorescence. Forensic Sci Int 327:110976. https://doi.org/10.1016/j.forsciint.2021.110976
Scafide KN, Ekroos RA, Mallinson RK et al (2023) Improving the forensic documentation of injuries through alternate light: a researcher–practitioner Partnership. J Forensic Nurs 19:30–40. https://doi.org/10.1097/JFN.0000000000000389
Na R, Stender I-M, Henriksen M, Wulf HC (2001) Autofluorescence of human skin is Age-Related after correction for skin pigmentation and redness. J Invest Dermatology 116:536–540. https://doi.org/10.1046/j.1523-1747.2001.01285.x
Hughes VK, Ellis PS, Langlois NEI (2006) Alternative light source (polilight) illumination with digital image analysis does not assist in determining the age of bruises. Forensic Sci Int 158:104–107. https://doi.org/10.1016/j.forsciint.2005.04.042
Hughes VK (2004) The practical application of reflectance spectrophotometry for the demonstration of haemoglobin and its degradation in bruises. J Clin Pathol 57:355–359. https://doi.org/10.1136/jcp.2003.011445
Limmen RM, Ceelen M, Reijnders UJL et al (2013) Enhancing the visibility of injuries with narrow-banded beams of light within the visible light spectrum. J Forensic Sci 58:518–522. https://doi.org/10.1111/1556-4029.12042
Moher D, Shamseer L, Clarke M et al (2015) Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Syst Rev 4:1. https://doi.org/10.1186/2046-4053-4-1
Page MJ, Moher D, Bossuyt PM et al (2021) PRISMA 2020 explanation and elaboration: updated guidance and exemplars for reporting systematic reviews. BMJ 372:n160. https://doi.org/10.1136/bmj.n160
Hettrick H, Hill C, Hardigan P (2017) Early detection of pressure Injury using a forensic alternate light source. Wounds 29:222–228
Dubey A, Rupani R, Sharma V et al (2022) Reflected near-infrared photography: digging deeper into post-mortem examination. J Forensic Leg Med 90:102397. https://doi.org/10.1016/j.jflm.2022.102397
Rowan P, Hill M, Gresham GA et al (2010) The use of infrared aided photography in identification of sites of bruises after evidence of the bruise is absent to the naked eye. J Forensic Leg Med 17:293–297. https://doi.org/10.1016/j.jflm.2010.04.007
Mimasaka S, Oshima T, Ohtani M (2018) Visualization of old bruises in children: use of violet light to record long-term bruises. Forensic Sci Int 282:74–78. https://doi.org/10.1016/j.forsciint.2017.11.015
Trefan L, Harris C, Evans S et al (2018) A comparison of four different imaging modalities – conventional, cross polarized, infra-red and ultra-violet in the assessment of childhood bruising. J Forensic Leg Med 59:30–35. https://doi.org/10.1016/j.jflm.2018.07.015
Black HI, Coupaud S, Daéid NN, Riches PE (2019) On the relationships between applied force, photography technique, and the quantification of bruise appearance. Forensic Sci Int 305:109998. https://doi.org/10.1016/j.forsciint.2019.109998
Lombardi M, Canter J, Patrick PA, Altman R (2015) Is fluorescence under an alternate light source sufficient to accurately diagnose subclinical bruising? J Forensic Sci 60:444–449. https://doi.org/10.1111/1556-4029.12698
Nijs HGT, De Groot R, Van Velthoven MFaM, Stoel RD (2019) Is the visibility of standardized inflicted bruises improved by using an alternate (‘forensic’) light source? Forensic Sci Int 294:34–38. https://doi.org/10.1016/j.forsciint.2018.10.029
Scafide KN, Sharma S, Tripp NE, Hayat MJ (2020) Bruise detection and visibility under alternate light during the first three days post-trauma. J Forensic Leg Med 69:101893. https://doi.org/10.1016/j.jflm.2019.101893
Scafide KN, Sheridan DJ, Downing NR, Hayat MJ (2020) Detection of inflicted bruises by alternate light: results of a Randomized Controlled Trial. J Forensic Sci 65:1191–1198. https://doi.org/10.1111/1556-4029.14294
Scafide KN, Downing NR, Kutahyalioglu NS et al (2021) Quantifying the degree of bruise visibility observed under White Light and an alternate light source. J Forensic Nurs 17:24–33. https://doi.org/10.1097/JFN.0000000000000304
Langlois NEI (2007) The science behind the quest to determine the age of bruises—a review of the English language literature. Forens Sci Med Pathol 3:241–251. https://doi.org/10.1007/s12024-007-9019-3
Olds K, Byard RW, Winskog C, Langlois NEI (2016) Validation of ultraviolet, infrared, and narrow band light alternate light sources for detection of bruises in a pigskin model. Forensic Sci Med Pathol 12:435–443. https://doi.org/10.1007/s12024-016-9813-x
Olds K, Byard RW, Winskog C, Langlois NEI (2017) Validation of alternate light sources for detection of bruises in non-embalmed and embalmed cadavers. Forensic Sci Med Pathol 13:28–33. https://doi.org/10.1007/s12024-016-9822-9
Pollitt EN, Anderson JC, Scafide KN et al (2016) Alternate light source findings of Common Topical products. J Forensic Nurs 12:97–103. https://doi.org/10.1097/JFN.0000000000000116
Anderson JC, Pollitt EN, Schildbach C et al (2021) Alternate light source findings of Common Topical Cosmetics and three removal methods. J Forensic Nurs 17:14–23. https://doi.org/10.1097/JFN.0000000000000300
Zonios G, Bykowski J, Kollias N (2001) Skin melanin, Hemoglobin, and light scattering properties can be quantitatively assessed in vivo using diffuse reflectance spectroscopy. J Invest Dermatology 117:1452–1457. https://doi.org/10.1046/j.0022-202x.2001.01577.x
Kollias N, Sayre RM, Zeise L, Chedekel MR (1991) New trends in photobiology. J Photochem Photobiol B 9:135–160. https://doi.org/10.1016/1011-1344(91)80147-A
Sully CJ, Olds KL, Langlois NEI (2019) Evaluation of a model of bruising in pigmented skin for investigating the potential for alternate light source illumination to enhance the appearance of bruises by photography of visible and infrared light. Forensic Sci Med Pathol 15:555–563. https://doi.org/10.1007/s12024-019-00135-0
Lovell RRH, Scott GBD, Hudson B, Osborne JA (1953) The effects of cortisone and adrenocorticotrophic hormone on dispersion of bruises in the skin. 1953
Funding
Open access funding provided by Swedish National Board of Forensic Medicine. This work was fully supported by the Swedish National Board of Forensic Medicine.
Open access funding provided by Swedish National Board of Forensic Medicine.
Author information
Authors and Affiliations
Contributions
A. Tyr: Conceptualization, Methodology, Investigation, Writing - original draft, review & editing. N. Heldring: Methodology, Writing - review & editing. B. Zilg: Writing - review & editing.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no conflict of interests.
Ethics approval
Not applicable.
Research involving human participants and/or animals
No animals were sacrificed for the purpose of our study.
Informed consent
Not applicable.
Financial interests
The authors declare they have no financial interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Tyr, A., Heldring, N. & Zilg, B. Examining the use of alternative light sources in medico-legal assessments of blunt-force trauma: a systematic review. Int J Legal Med (2024). https://doi.org/10.1007/s00414-024-03262-8
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00414-024-03262-8