In this paper, we report results of radiation dose measurements in fingernails of a worker who sustained a radiation injury to his right thumb while using 130 kVp X-ray for nondestructive testing. Clinically estimated absorbed dose was about 20–25 Gy. Electron paramagnetic resonance (EPR) dose assessment was independently carried out by two laboratories, the Naval Dosimetry Center (NDC) and French Institut de Radioprotection et de Sûreté Nucléaire (IRSN). The laboratories used different equipments and protocols to estimate doses in the same fingernail samples. NDC used an X-band transportable EPR spectrometer, e-scan produced by Bruker BioSpin, and a universal dose calibration curve. In contrast, IRSN used a more sensitive Q-band stationary spectrometer (EMXplus) with a new approach for the dose assessment (dose saturation method), derived by additional dose irradiation to known doses. The protocol used by NDC is significantly faster than that used by IRSN, nondestructive, and could be done in field conditions, but it is probably less accurate and requires more sample for the measurements. The IRSN protocol, on the other hand, potentially is more accurate and requires very small amount of sample but requires more time and labor. In both EPR laboratories, the intense radiation-induced signal was measured in the accidentally irradiated fingernails and the resulting dose assessments were different. The dose on the fingernails from the right thumb was estimated as 14 ± 3 Gy at NDC and as 19 ± 6 Gy at IRSN. Both EPR dose assessments are given in terms of tissue kerma. This paper discusses the experience gained by using EPR for dose assessment in fingernails with a stationary spectrometer versus a portable one, the reasons for the observed discrepancies in dose, and potential advantages and disadvantages of each approach for EPR measurements in fingernails.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  • Black PJ, Swarts SG (2010) Ex-vivo analysis of irradiated fingernails: chemical yields and properties of radiation-induced and mechanically-induced radicals. Health Phys 98:301–308

    Article  Google Scholar 

  • Chandra H, Symons CR (1987) Sulphur radicals formed by cutting α-keratin. Nature 328:833–834

    Article  ADS  Google Scholar 

  • Dalgarno BG, McClymont JD (1989) Evaluation of ESR as a radiation accident dosimetry technique. Appl Radiat Isot 40:1013–1020

    Article  Google Scholar 

  • He X, Gui J, Matthews TP, Williams BB, Swarts SG, Grinberg O, Sidabras J, Wilcox DE, Swartz HM (2011) Advances towards using finger/toenail dosimetry to triage a large population after potential exposure to ionizing radiation. Radiat Meas 46:882–887

    Article  Google Scholar 

  • International Atomic Energy Agency (2002) Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. Vienna: IAEA; IAEATECDOC-1331

  • Regulla DF, Deffner U (1989) Dose estimation by ESR spectroscopy at a fatal radiation accident. Appl Radiat Isot 40:1039–1043

    Article  Google Scholar 

  • Reyes RA, Romanyukha A, Trompier F, Mitchell CA, Clairand I, De T, Benevides LA, Swartz HM (2008) Electron paramagnetic resonance in human fingernails: the sponge model implication. Radiat Environ Biophys 47:515–526

    Article  Google Scholar 

  • Reyes RA, Romanyukha A, Olsen C, Trompier F, Benevides LA (2009) Electron paramagnetic resonance in irradiated fingernails: variability of dose dependence and possibilities of initial dose assessment. Radiat Environ Biophys 48:295–310

    Article  Google Scholar 

  • Reyes RA, Trompier F, Romanyukha A (2012) Study of the stability of EPR signals after irradiation of fingernail samples. Health Phys 103:175–180

    Google Scholar 

  • Romanyukha A, Trompier F, LeBlanc B, Calas C, Clairand I, Mitchell CA, Smirniotopoulos JG, Swartz H (2007) EPR dosimetry in chemically treated fingernails. Radiat Meas 42:1110–1113

    Article  Google Scholar 

  • Romanyukha A, Reyes RA, Trompier F, Benevides LA (2010) Fingernail dosimetry: current status and perspectives. Health Phys 98:296–300

    Article  Google Scholar 

  • Romanyukha A, Trompier F, Reyes RA, Melanson MA (2011) EPR measurements of fingernails in Q-band. Radiat Meas 46:888–892

    Article  Google Scholar 

  • Schauer DA, Desrosiers MF, Kuppusamy P, Zweier JL (1996) Radiation dosimetry of an accidental overexposure using EPR spectrometry and imaging of human bone. Appl Radiat Isot 47:1345–1350

    Article  Google Scholar 

  • Swartz HM, Flood AB, Gougelet RM, Rea ME, Nicolalde RJ, Williams BB (2010) A critical assessment of biodosimetry methods for large-scale incidents. Health Phys 98:95–108

    Article  Google Scholar 

  • Symons MCR, Chandra H, Wyatt JI (1995) Electron paramagnetic resonance spectra of irradiated fingernails: a possible measure of accidental exposure. Radiat Prot Dosimetry 58:11–15

    Google Scholar 

  • Trompier F, Kornak L, Calas C, Romanyukha A, LeBlanc B, Clairand I, Mitchell CA, Swartz H (2007) Protocol for emergency EPR dosimetry in fingernails. Radiat Meas 42:1085–1088

    Article  Google Scholar 

  • Trompier F, Romanyukha A, Kornak L, Calas C, LeBlanc B, Mitchell C, Swartz H, Clairand I (2009) Electron paramagnetic resonance radiation dosimetry in fingernails. Radiat Meas 44:6–10

    Article  Google Scholar 

  • Trompier F, Romanyukha A, Reyes R, Vezin H, Queinnec F, Gourier D (2014a) State of the art in nails dosimetry: free radicals identification and reaction mechanisms. Radiat Environ Biophys 53:291–303

    Article  Google Scholar 

  • Trompier F, Queinnec F, Bey E, De Revel T, Lataillade JJ, Clairand I, Benderitter M, Bottollier-Depois JF (2014b) EPR retrospective dosimetry with fingernails: report on first application cases. Health Phys 106:798–805

    Article  Google Scholar 

  • Wilcox DE, He X, Gui J, Ruuge AE, Li H, Williams BB, Swartz HM (2010) Dosimetry based on EPR spectral analysis of fingernail clippings. Health Phys 98:309–317

    Article  Google Scholar 

Download references

Acknowledgments

The authors would like to thank Dr. Art Heiss (BrukerBiospin USA) for excellent technical support of this work. The authors would like to acknowledge funding from the Pilot Project Program of the Dartmouth Physically Based Center for Medical Countermeasures Against Radiation, with NIH funding from the National Institute of Allergy and Infectious Diseases (U19-AI091173).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alexander Romanyukha.

Additional information

Disclaimer: The views expressed in this paper are those of the authors and do not necessarily reflect the official policy or position of the Department of the Navy, Department of Defense, Department of Energy, or the US Government.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Romanyukha, A., Trompier, F., Reyes, R.A. et al. Electron paramagnetic resonance radiation dose assessment in fingernails of the victim exposed to high dose as result of an accident. Radiat Environ Biophys 53, 755–762 (2014). https://doi.org/10.1007/s00411-014-0553-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00411-014-0553-6

Keywords

Navigation