Abstract

Performing transcatheter aortic valve implantation with high implantation technique, i.e. with an aorto-ventricular ratio > 60/40, reduces the need of permanent pacemaker implantation. Valve calcification and prosthesis oversizing are predictors of permanent pacemaker implantation, but there are no available data on their role when transcatheter aortic valve implantation is performed with an aorto-ventricular ratio > 60/40. The aim of this study was to evaluate the effect of leaflets/annulus calcification and prosthesis oversizing on the incidence of permanent pacemaker implantation after transcatheter aortic valve implantation with a high implantation technique. Transcatheter aortic valve implantation was performed in 48 patients implanting a balloon-expandable transcatheter heart valve with an aorto-ventricular ratio > 60/40. Calcium burden was assessed by preprocedural multidetector computed tomography. An invasive electrophysiological study was performed before and after transcatheter aortic valve implantation. Five patients (10.4%) needed permanent pacemaker implantation. At univariate analysis, baseline right bundle branch block and postprocedural PR, QRS and His-ventricular interval elongation significantly predicted permanent pacemaker implantation (p < 0.05). Receiver-operating characteristic curve analysis showed a correlation between transcatheter heart valve oversizing and permanent pacemaker implantation need, with the best cut-off being 17% (AUC = 0.72, p = 0.033). Linear regression analysis demonstrated that QRS complex elongation was related to total, left and non-coronary leaflet calcification (p < 0.05). This study demonstrates that, when transcatheter aortic valve implantation is performed using a balloon-expandable transcatheter heart valve deployed with an aorto-ventricular ratio > 60/40, the presence of leaflets/annulus calcification or the need to oversize the prosthesis correlate with the occurrence of pathological cardiac conduction delays.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Leon MB, Smith CR, Mack M, Craig Miller D, Moses JW, Svensson LG, Murat Tuzcu E, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S, PARTNER Trial Investigators (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607

    Article  CAS  Google Scholar 

  2. Smith CR, Leon MB, Mack MJ, Craig Miller D, Moses JW, Svensson LG, Murat Tuzcu E, Webb JG, Fontana GP, Makkar RR, Williams M, Dewey T, Kapadia S, Babaliaros V, Thourani VH, Corso P, Pichard AD, Bavaria JE, Herrmann HC, Akin JJ, Anderson WN, Wang D, Pocock S, PARTNER Trial Investigators (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187–2198

    Article  CAS  Google Scholar 

  3. Walther T, Hamm CW, Schuler G, Berkowitsch A, Kötting J, Mangner N, Mudra H, Beckmann A, Cremer J, Welz A, Lange R, Kuck K-H, Mohr FW, Möllmann H, GARY Executive Board (2015) Perioperative results and complications in 15,964 transcatheter aortic valve replacements: prospective data from the GARY registry. J Am Coll Cardiol 65:2173–2180

    Article  Google Scholar 

  4. Mack M, Leon M, Thourani VH, Makkar R, Kodali SK, Russo M, Kapadia SR, Malaisrie SC, Cohen DJ, Pibarot P, Leipsic J, Hahn RT, Blanke P, Williams MR, McCabe JM, Brown DL, Babaliaros V, Goldman S, Szeto WY, Genereux P, Pershad A, Pocock SJ, Alu MC, Webb JG, Smith CR, PARTNER 3 Investigators (2019) Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med 380:1695–1705

    Article  Google Scholar 

  5. De Torres-Alba F, Kaleschke G, Diller GP, Vormbrock J, Orwat S, Radke R, Reinke F, Fischer D, Reinecke H, Baumgartner H (2016) Changes in the pacemaker rate after transition from Edwards SAPIEN XT to SAPIEN 3 transcatheter aortic valve implantation: the critical role of valve implantation height. JACC Cardiovasc Interv 9:805–813

    Article  Google Scholar 

  6. Husser O, Pellegrini C, Kessler T, Burgdorf C, Thaller H, Mayr NP, Kasel AM, Kastrati A, Schunkert H, Hengstenberg C (2016) Predictors of permanent pacemaker implantations and new-onset conduction abnormalities with the SAPIEN 3 balloon-expandable transcatheter heart valve. JACC Cardiovasc Interv 9:244–254

    Article  Google Scholar 

  7. Kodali S, Thourani VH, White J, Malaisrie SC, Lim S, Greason KL, Williams M, Guerrero M, Eisenhauer AC, Kapadia S, Kereiakes DJ, Herrmann HC, Babaliaros V, Szeto WY, Hahn RT, Pibarot P, Weissman NJ, Leipsic J, Blanke P, Whisenant BK, Suri RM, Makkar RR, Ayele GM, Svensson LG, Webb JG, Mack MJ, Smith CR, Leon MB (2016) Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis. Eur Heart J 37(28):2252–2262

    Article  Google Scholar 

  8. Zhang ZM, Rautaharju PM, Soliman EZ, Manson JE, Cain ME, Martin LW, Bavry AA, Mehta L, Vitolins M, Prineas RJ (2012) Mortality risk associated with bundle branch blocks and related repolarization abnormalities (from the Women’s Health Initiative [WHI]). Am J Cardiol 110:1489–1495

    Article  Google Scholar 

  9. Zannad F, Huvelle E, Dickstein K, van Veldhuisen DJ, Stellbrink C, Køber L, Cazeau S, Ritter P, Maggioni AP, Ferrari R, Lechat P (2007) Left bundle branch block as a risk factor for progression to heart failure. Eur J Heart Fail 9:7–14

    Article  Google Scholar 

  10. Auffret V, Puri R, Urena M, Chamandi C, Rodriguez-Gabella T, Philippon F, Rodés-Cabau J (2017) Conduction disturbances after transcatheter aortic valve replacement, current status and future perspectives. Circulation 136:1049–1069

    Article  Google Scholar 

  11. Siontis GC, Jüni P, Pilgrim T, Stortecky S, Büllesfeld L, Meier B, Wenaweser P, Windecker S (2014) Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. J Am Coll Cardiol 64:129–140

    Article  Google Scholar 

  12. Latsios G, Gerckens U, Buellesfeld L, Mueller R, John D, Yuecel S, Syring J, Sauren B, Grube E (2010) “Device landing zone” calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI. Catheter Cardiovasc Interv 76:431–439

    Article  Google Scholar 

  13. Kiani S, Kamioka N, Black GB, Louis Roy Lu M, Lisko JC, Rao B, Mengistu A, Gleason PT, Stewart JP, Caughron H, Dong A, Patel H, Grubb KJ, Greenbaum AB, Devireddy CM, Guyton RA, Leshnower B, Merchant FM, El-Chami M, Westerman SB, Lloyd MS, Babaliaros VC, Hoskins MH (2019) Development of a risk score to predict new pacemaker implantation after transcatheter aortic valve replacement. JACC Cardiovasc Interv 12:2133–2142

    Article  Google Scholar 

  14. Tarantini G, Mojoli M, Purita P, Napodano M, D’Onofrio A, Frigo A, Covolo E, Facchin M, Isabella G, Gerosa G, Iliceto S (2015) Unravelling the (arte)fact of increased pacemaker rate with the Edwards SAPIEN 3 valve. EuroIntervention 11:343–350

    Article  Google Scholar 

  15. Iacovelli F, Pignatelli A, Giugliano G, Stabile E, Cicala M, Salemme L, Cioppa A, Popusoi G, Pucciarelli A, Verdoliva S, Bortone AS, Losi M-A, Coscioni E, Esposito G, Tesorio T (2018) Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation. Europace 20:116–123

    PubMed  Google Scholar 

  16. Ramanathan PK, Nazir S, Elzanaty AM, Nesheiwat Z, Mahmood M, Rachwal W, Riordan C, Letcher J, Yenrick K, Boonie E, Moront MG, Redfern RE, Crescenzo D (2020) Novel method for implantation of balloon expandable transcatheter aortic valve replacement to reduce pacemaker rate—line of lucency method. Struct Heart 4(5):427–432

    Article  Google Scholar 

  17. Rogers T, Koifman E, Patel N, Gai J, Torguson R, Corso P, Waksman R (2017) Society of Thoracic Surgeons score variance results in risk reclassification of patients undergoing transcatheter aortic valve replacement. JAMA Cardiol 2:455–456

    Article  Google Scholar 

  18. Barbanti M, Yang TH, Rodés Cabau J, Tamburino C, Wood DA, Jilaihawi H, Blanke P, Makkar RR, Latib A, Colombo A, Tarantini G, Raju R, Binder RK, Nguyen G, Freeman M, Ribeiro HB, Kapadia S, Min J, Feuchtner G, Gurtvich R, Alqoofi F, Pelletier M, Ussia GP, Napodano M, Sandoli de Brito F Jr, Kodali S, Norgaard BL, Hansson NC, Pache G, Canovas SJ, Zhang H, Leon MB, Webb JG, Leipsic J (2013) Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation 128:244–253

    Article  Google Scholar 

  19. Zhu D, Chen W, Peng L, Guo Y (2015) Valve sizing for pure aortic regurgitation during transcatheter aortic valve replacement: deformation dynamic of the aortic annulus in different valve pathology may be different. JACC Cardiovasc Interv 8:372–373

    Article  Google Scholar 

  20. Angelillis M, Costa G, De Backer O, Mochia V, Christou A, Giannini C, Spontoni P, De Carlo M, Søndergaard L, Miccoli M, Petronio AS (2021) Threshold for calcium volume evaluation in patients with aortic valve stenosis: correlation with Agatston score. J Cardiovasc Med 22:496–502

    Article  Google Scholar 

  21. Jilaihawi H, Makkar RR, Kashif M, Okuyama K, Chakravarty T, Shiota T, Friede G, Nakamura M, Doctor N, Rafique A, Shibayama K, Mihara H, Trento A, Cheng W, Friedman J, Berman D, Fontana GP (2014) A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging 15:1324–1332

    Article  Google Scholar 

  22. Nashef SAM, Roques F, Hammill BG, Peterson ED, Michel P, Grover FL, Wyse RKH, Bruce Ferguson T, EurpSCORE Project Group (2002) Validation of European System for Cardiac Operative Risk Evaluation (EuroSCORE) in North American cardiac surgery. Eur J Cardiothorac Surg 22:101–105

    Article  Google Scholar 

  23. Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es G-A, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodés-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB, Valve Academic Research Consortium (VARC)-2 (2012) Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg 42:S45–S60

    Article  Google Scholar 

  24. Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt O-A, Cleland J, Deharo J-C, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE (2013) 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace 15:1070–1118

    Article  Google Scholar 

  25. Moreno R, Dobarro D, López de Sá E, Prieto M, Morales C, Calvo Orbe L, Moreno-Gomez I, Filgueiras D, Sanchez-Recalde A, Galeote G, Jiménez-Valero S, Lopez-Sendon J-L (2009) Cause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study. Circulation 120:e29–e30

    Article  Google Scholar 

  26. Eksik A, Gul M, Uyarel H, Surgit O, Yildirim A, Uslu N, Aksu H, Turen S, Uzun F, Satılmısoglu H, Erol MK, Bakir I (2013) Electrophysiological evaluation of atrioventricular conduction disturbances in transcatheter aortic valve implantation with Edwards Sapien prosthesis. J Invasive Cardiol 25:305–309

    PubMed  Google Scholar 

  27. Rivard L, Schram G, Asgar A, Khairy P, Andrade JG, Bonan R, Dubuc M, Guerra PG, Ibrahim R, Macle L, Roy D, Talajic M, Dyrda K, Shohoudi A, le Polain de Waroux J-B, Thibault B (2015) Electrocardiographic and electrophysiological predictors of atrioventricular block after transcatheter aortic valve replacement. Heart Rhythm 12:321–329

    Article  Google Scholar 

  28. Fujita B, Kütting M, Seiffert M, Scholtz S, Egron S, Prashovikj E, Börgermann J, Schäfer T, Scholtz W, Preuss R, Gummert J, Steinseifer U, Ensminger SM (2016) Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging 17:1385–1393

    Article  Google Scholar 

  29. Staubach S, Franke J, Gerckens U, Schuler G, Zahn R, Eggebrecht H, Hambrecht R, Sack S, Richardt G, Horack M, Senges J, Steinberg DH, Ledwoch J, Fichtlscherer S, Doss M, Wunderlich N, Sievert H, Investigators G-R (2013) Impact of aortic valve calcification on the outcome of transcatheter aortic valve implantation: results from the prospective multicenter German TAVI registry. Catheter Cardiovasc Interv 81:348–355

    Article  Google Scholar 

Download references

Acknowledgements

The author Donato Gerardi is currently attending the Cardiopath PhD program. We would like to thank biomedical engineer Giovanna Perrotta, allied professional serving as filed product manager for Biosense Webster Inc, for her precious support at the EP workstation.

Funding

This research was supported from an unrestricted grant from Edwards Lifesciences (I15-220).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Fortunato Iacovelli.

Ethics declarations

Conflict of interest

The author Giancarlo Schettino has served as clinical specialist THV for Edwards Lifesciences; the remaining authors have no conflicts of interest to declare.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Iacovelli, F., Giugliano, G., Gerardi, D. et al. Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique. Heart Vessels 37, 337–346 (2022). https://doi.org/10.1007/s00380-021-01913-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00380-021-01913-z

Keywords

Navigation