1 Introduction

According to Rayleigh, a spray is characterized as a collection of droplets in a gas-filled environment (Rayleigh 1878). Sprays serve a wide range of applications, including liquid fuel injection in combustion engines, industrial powder production via spray drying, as well as for some specific medical treatments. The ability to measure spray characteristics holds fundamental importance, helping to improve and control the optimization of systems using spray-based technologies. Regarding combustion science, the knowledge of spray quantities such as droplet size distribution and mean diameter is of utmost importance for the understanding of the subsequent liquid–air mixing and evaporation processes (Ashgriz 2011) (Lefebvre and McDonell 2017).

To measure these quantities experimentally, two laser-based diagnostics are mainly available in the literature: point measurements (Durst and Zaré 1975) (Bachalo 1980) and 2D imaging (Berrocal et al. 2023). Phase doppler anemometry (PDA) is the most commonly used method for determining the droplet size and velocity (Bachalo and Houser 1987; Lacoste et al. 2003; Hage et al. 2010). Despite providing good accuracy, this calibration-free method is limited to point measurements, which makes the technique time-consuming for the characterization of a whole spray. In order to overcome this limitation, laser sheet imaging techniques offer an alternative solution, allowing for high spatial resolution and fast measurements. For droplet sizing, laser sheet imaging is mainly based on intensity ratio measurements, such as the polarization ratio technique (Hofeldt 1993a; Hofeldt 1993b), the LIF/Mie technique (LIF for Laser Induced Fluorescence and Mie for the Lorenz–Mie scattering signal) (Yeh et al. 1993; Domann and Hardalupas 2003) and the Raman/Mie technique (Malarski et al. 2009). When using these methods, the signal ratio is proportional to a statistical mean droplet diameter (Mugele and Evans 1951). Theoretically, the LIF/Mie and the Raman/Mie techniques yield a ratio proportional to the Sauter mean diameter (SMD or D32).

The LIF/Mie technique is often related to the use of an excitation wavelength in the visible range (Le Gal et al. 1999; Domann and Hardalupas 2003), leading to the need of adding a dye in the injected liquid. This limits the measurement to non-evaporating sprays. To suppress the fluorescence signal from the vapor phase of evaporating sprays, the exciplex method LIEF/Mie can be used (Zeng et al. 2012; Qiu et al. 2023). However, under certain hot evaporating conditions the amount of dye may not contribute to the gas phase but instead increase in concentration in droplets, leading to a significant signal variation during the measurement time (Frackowiak and Tropea 2010). This increase of dye in significant proportions can also alter the physical properties of the fluid, such as surface tension and viscosity (Stiti et al. 2021). The polarization ratio is a good alternative technique for 2D droplet sizing in evaporating sprays because it does not require a fluorescence signal. This is based on the calculation of the ratio between the perpendicular (s-pol; β = 90°) and parallel (p-pol; β = 0°) polarized scattered lights providing a statistical surface mean diameter (D21).

In practice, intensity-based techniques depend on parameters such as laser excitation wavelength, refractive index, scattering angle and particle size. As demonstrated in the literature, these parameters affect the respective proportions of the light intensity ratio and mean diameter (Massoli et al. 1989; Charalampous and Hardalupas 2011a, b; Bareiss et al. 2013). A calibration procedure is applied by comparing the intensity ratio with the results obtained by a PDA instrument in a steady-state spray (Sankar et al. 1999; Le Gal et al. 1999), or by using a monodisperse droplet generator that accurately controls the droplet diameter within the range of interest (Koegl et al. 2018a, b).

In sprays of low optical density, where single light scattering predominates, laser imaging can directly provide quantitative results (Garcia et al. 2023). However, in optically dense sprays, additional scattering events occur leading to unwanted contributions (Berrocal et al. 2005a; b) (Lehnert et al. 2023):

  1. 1.

    The signal generated from the laser sheet can be multiply scattered on its way to the camera (along a path normal to the laser sheet).

  2. 2.

    The laser sheet widens along the incident path through the spray due to multiple light scattering in semi-forward direction. This broadening of the illumination generates a signal out of the intended plane.

A technique based on the use of spatially modulated laser sheet, called SLIPI (Structured Laser Illumination Planar Imaging) (Berrocal et al. 2008; Kristensson et al. 2008), suppresses efficiently all the unwanted light described in the contribution 1 and most of it described in the contribution 2. The technique has been applied to various liquid injection systems including hollow cones (Kristensson et al. 2010), air assisted (Wellander et al. 2011), diesel (Berrocal et al. 2012) and direct-injection spark-ignition (DISI) (Koegl et al. 2019) sprays. In addition, SLIPI can also be used for the three-dimensional (3D) reconstruction, by collecting 2D planes shifted in space (Wellander et al. 2011; Mishra et al. 2019). In a recent study (Stiti et al. 2023), it has been demonstrated for the first time that the polarization ratio technique is successfully applicable to optical dense sprays when coupled with the SLIPI method.

The aim of the work presented in this article is to perform an experimental and numerical analysis of the parameters influencing the polarization ratio technique and to provide insights and limitations of the technique for future particle sizing of dense atomizing sprays. The remainder of the paper consists of five sections:

  • The first section revisits the theoretical background of the technique and conducts numerical Lorenz–Mie simulations to demonstrate its applicability to a polydisperse spray.

  • In the second section, a detailed description of the experimental setup is presented, featuring the utilization of a telecentric lens and a fully integrated beam splitter device. Additionally, the post-processing routine for generating polarization ratio map is outlined in this section.

  • The third section undertakes an experimental analysis of the impact of incident laser polarization orientation on the reliability of the polarization ratio with the D21 droplet size.

  • In the fourth section, the study focuses on the polarization ratio measurement capabilities for different complex refractive indices (\(n = { }n_{r} + ik\)). Both numerical (MiePlot simulations) and experimental studies are employed.

  • Finally, an optimal configuration of SLIPI–polarization ratio is defined and the measurement of D21 is achieved in 3D on an industrial transient water spray running at 50 bar injection pressure. Those measurements are achieved by rotating the injector and doing a tomographic reconstruction.

2 Theoretical background of polarization ratio droplet sizing

The first applications of the polarization ratio technique were presented in early 1980th, where the results were related to the use of isothermal sprays and to combustion applications (Beretta et al. 1981, 1983, 1985). In Beretta and co-workers work, the physical understanding of light scattering by droplets is limited to the interpretation of the angular scattering coefficient \(\mu_{{\text{s}}} \left( \theta \right)\) [m−1] which is directly proportional to \(N\) [#/m3], corresponding to the number of droplets by volume unit (Beretta et al. 1985):

$$\mu_{s} \left( \theta \right) = N \sigma_{{\text{s}}} \left( {\theta ,n,D} \right)$$
(1)

where \(\sigma_{{\text{s}}} \left( {\theta ,n,D} \right)\) is the angular scattering cross-section [m2], which is a function of the scattering angle \(\theta\) [°], the droplet diameter \(D\) [m] and the complex refractive index n (Van de Hulst 1981).

Two physical interpretations can be attributed to the scattering cross-section: first, it corresponds to the ratio between the total flux of light scattered by a droplet \(W_{{\text{s}}}\) [W] and the incident light flux density \(I_{i}\) [W/m2]; second, it can be interpreted as a geometrical cross-section receiving the incident energy and scattering it according to an efficiency factor \(Q\):

$$\sigma_{{\text{s}}} \left( {\theta ,n,D} \right) = \frac{{W_{{\text{s}}} \left( {\theta ,n,D} \right)}}{{I_{i} }} = Q\left( {\theta ,n} \right) \sigma_{{\text{g}}} \left( D \right)$$
(2)

where \(\sigma_{{\text{g}}}\) [m2] is the geometrical cross-section which depends on the observed droplet diameter \(D\) [m] (\(\sigma_{{\text{g}}} = \pi D^{2} /4\)).

Using this approach, Massoli and co-workers, or even Hofeldt and Hanson, extended the technique to the application of the polarization ratio technique to single droplet sizing (Massoli et al. 1989; Hofeldt and Hanson 1991). The polarization ratio is obtained by analyzing the signal produced by individual droplets, at an observation angle of \(\theta\) = 90°. The authors demonstrated that, over a large size range (10–200 µm), the s-pol signal is proportional to the projected surface area (D2), whereas the p-pol signal is proportional to the diameter (D). By applying an s-pol/p-pol ratio, it is thus possible to recover a value close to D21. However, the strong oscillations in the light scattered by micrometric spherical droplets prevent any direct correlation between size and scattered intensity (Hofeldt 1993a; b). These Lorenz–Mie oscillations are caused by the interference of light scattered from different refractive orders interacting within a single droplet. A solution to this problem was found by Beretta and co-workers, who studied the effects of absorption on polarization ratio technique using numerical methods (Beretta et al. 1985). They demonstrated, for a single droplet, that the surface waves are progressively damped as the absorption index increases. Indeed, in the case of a transparent sphere, the wave mostly travels in a lossless medium. However, if the droplets are no longer transparent, part of the energy is absorbed and the surface waves are more strongly damped and consequently the oscillations in the scattered intensity decrease. The major drawback with this solution is that, for liquids with a low absorption rate at the excitation wavelength (e.g., water at 532 nm), a dye must be added. An alternative solution is the use of ultra-short laser pulses to significantly reduce the oscillations from the scattering phase functions (Bakic et al. 2008). To solve this issue femtosecond laser pulses can be used for droplet sizing based on the polarization ratio technique (Bareiss et al. 2013). The results of this study confirm that the time and coherence length of the incident laser light influence the development of Lorenz–Mie signal ripples. All of this preliminary research on the polarization ratio technique relates to single droplets. However, according to Hofeldt (1993a), with a polydisperse spray where the intensity-based scattered measurements are derived from a statistical droplet size passing through the measurement volume, the strong oscillations induced by the large droplets are also attenuated by the contribution of the smaller droplets. These results can be demonstrated numerically by calculating the scattered light from a sphere using the Lorenz–Mie theory and the Debye series. Laven developed a computer program (Laven 2008), called “MiePlot”, using a simple interface, based on the classic BHMIE algorithm (Bohren and Huffman 1983).

In the case of a polydisperse spray, where the droplet sizes can be described by a distribution function \(f\left( D \right)\), Eq. (1) can be rewritten for each polarized scattering coefficients:

$$\mu_{ \bot } \left( \theta \right) = \mathop \int \limits_{0}^{\infty } N \sigma_{ \bot } \left( {\theta ,n,D} \right) f\left( D \right){\text{d}}D \propto N\mathop \int \limits_{0}^{\infty } D^{2} f\left( D \right) {\text{d}}D$$
(3)
$$\mu_{\parallel } \left( \theta \right) = \mathop \int \limits_{0}^{\infty } N \sigma_{\parallel } \left( {\theta ,n,D} \right) f\left( D \right){\text{d}}D \propto N\mathop \int \limits_{0}^{\infty } D f\left( D \right) {\text{d}}D$$
(4)

where \(\sigma_{ \bot } \left( {\theta ,n,D} \right)\) and \(\sigma_{\parallel } \left( {\theta ,n,D} \right)\) are the s-pol and p-pol scattering cross-section, respectively.

Simulations were carried out using the MiePlot software to demonstrate the dependence indicated in Eqs. 3 and 4, as shown in Fig. 1a, b. The input data for this code are the real (nr) and imaginary (ik) parts of the refractive index, the laser excitation wavelength λ, the scattering angle \(\theta\), the laser polarization (s-pol, p-pol or Unpolarized) and the diameter range of the droplet \(D\) (single droplets or polydisperse distributions). The results show the simulated Lorenz–Mie scattered intensity for s-pol and p-pol polarization as a function of droplet diameter in 1–100 µm range. A scattering angle of 90°, a center wavelength of λ = 532, a refractive index of n = 1.33 + 0i (pure water) and a diameter resolution of Δθ = 0.05 µm are used for the calculations, corresponding to the experiments described in the second section of this paper. For monodisperse diameter distributions, the results show strong ripples for large droplets. However, these strong oscillations can be reduced by the polydispersion of a spray, as shown in Fig. 1 (b). In the polydisperse simulation, the mean diameter is given along the x-axis, assuming a log-normal distribution with a standard deviation of 20% and using 20 points in the distribution. This type of droplet size distribution is typically observed in simple x-type pressurized injectors, similar to the one employed in this article. Hence, this distribution hypothesis is utilized here as an initial approximation. The signal detection is assumed as a point receiver located at 90° scattering angle where an additional aperture (± 2.5°) is also considered to simulate the collection angle Δθ = 5° of the telecentric lens used in the experiment. It can be observed in Fig. 1c, d that the collection angle reduces the oscillations. However, the theoretical residual uncertainty remains evident and is imposed by the presence of ripples which increases for larger droplets. In addition, a reduction of ripples in the scattering phase function can be observed when the polydispersity is considered in the simulation. On the one hand, for single droplet applications, the results show a nonlinear relation between polarization ratio γ and diameter D (the best fit is given by the linear trend given on the graphic: γ = 1.03D–5.35). On the other hand, for polydisperse configurations, the results show a quasi-linear relation between ratio and mean diameter (the best fit is given by the linear trend given on the graphic: γ = 0.09D + 0.37).

Fig. 1
figure 1

MiePlot simulations of the Lorenz–Mie scattered signals s-pol and p-pol, as a function of water droplet diameter when considering single droplets in (a) and polydisperse size distributions in (b). The related polarization ratio γ is respectively given in (c) and (d), without aperture (in yellow) and with an aperture angle of Δθ = 5° (in green). The ratio is obtained with an incident light polarization oriented at β 45° (50% s-pol and 50% p-pol). For better readability, the vertical scale on c is plotted on a logarithmic scale

To further investigate the theoretical relationship between the polarization ratio and D21, the influence of the droplet size distribution function is studied. Three log-normal distributions with different standard deviations (σ1 = 0.01%, σ2 = 1%, and σ3 = 20%) and two bimodal distributions (a narrow one and a broad one) are used to compute the ratio. The results are illustrated in Fig. 2. Notably, significant oscillations are observed for the log-normal distribution with σ1 = 0.01%. In this case, the results are similar to those obtained using single droplets. This type of monodisperse distribution is not representative of the spray investigated experimentally. Conversely, for models with σ = 1% and 20%, the oscillations are substantially reduced, and the curves nearly superimpose on each other. Moreover, the results from the two bimodal distributions align closely with those of the log-normal models. To quantify the differences between each distribution, a comparison is realized, where the ratio values are derived for different diameters.

Fig. 2
figure 2

Polarization ratio γ as a function of D21 for various particle size distributions: log-normal (σ1 = 0.01%, σ2 = 1%, and σ3 = 20%) and bimodal. Each simulation is computed with θ = 90° and an aperture angle of Δθ = 5°. The evolution of the polarization ratio is shown (plots on the bottom) by assuming four particle size distributions

As shown in the “Bimodal vs Log-normal distribution” in Fig. 2, the discrepancy of the ratio values increases with diameter. Specifically, there is an observed variation in the range of ratio values of about 7% for small diameter (i.e., D21 = 10 μm), while it reaches 58% for large diameter (i.e., D21 = 80 μm). Additionally, the results indicate ratio values higher for a log-normal distribution. This observation suggests that the significant presence of large droplets may affect the accuracy of the ratio, particularly for higher D21 values (> 50 μm). For example, in the case of a log-normal distribution for a D21 = 60 μm and a standard deviation σ3 = 20%, it is possible to find several droplets above 100 μm, unlike the other distributions where diameters do not exceed 90 μm. Hence, the shape of the particle size distribution seems to significantly influences the value of the ratio.

As previously stated, the polarization ratio technique is based on the calculation of the ratio of the vertical (s-pol) and horizontal (p-pol) polarized Lorenz–Mie scattered signals. Using now an imaging system, where a detection volume is imaged which contains a certain number of droplets with different diameters, the signals of the individual droplets (k) recorded by each pixel (i, j) are ensemble averaged. Considering the signal emitted by the droplets as a scattered flux density, the ratio of the two perpendicular and parallel polarized scattered intensities can be written as follows:

$$\gamma_{i,j} = \left( {\frac{{I_{{ \bot {\text{s}}}} }}{{I_{\parallel s} }}} \right)_{i,j} = \frac{{{ }C_{ \bot } \mathop \sum \nolimits_{k} N_{i,j} D_{i,j}^{2} }}{{{ }C_{\parallel } \mathop \sum \nolimits_{k} N_{i,j} D_{i,j} }} = C\left( {D_{21} } \right)_{i,j}$$
(5)

where \(I_{{ \bot {\text{s}}}}\) and \(I_{\parallel s}\) are the s-pol and p-pol scattered intensity, \(N_{i,j}\) is the number of particles of size k captured in the pixel of coordinates (i, j), \(C_{ \bot }\) and \({ }C_{\parallel }\) are two constants experimentally determined by a calibration. The intensity ratio measured in each map pixel is therefore proportional to the local surface mean diameter, \(D_{21}\) (Lefebvre and McDonell 2017). Note that experimentally, there is variation of light intensity that is related to:

  • Non-uniformity of the laser beam profile (different light intensity at different locations)

  • Variation of light intensity over time (different light intensity between each recordings)

  • Effects of light extinction along the incident direction (there is much more light at the entrance of the spray than at the exit)

  • Effects of light extinction between the laser sheet and the camera (various loss of light on the way to the camera as the droplet concentration is highly inhomogeneous)

However, as the two polarized images are simultaneously recorded with the same field-of-view, they are both affected in the same way. Thus, their ratio allows to efficiently suppressed unwanted effects related to any light intensity variation.

3 Description of the experiment

3.1 SLIPI–polarization ratio optical setup

The optical setup of the SLIPI–polarization ratio is described in Fig. 3. A continuous laser (Spectra-Physics Millenia Prime, 532 nm, 5 W) is used to illuminate the droplets. The beam is converted into a structured laser sheet of 12-cm hight and 2-mm thick, by a combination of spherical and cylindrical lenses. A diffractive optical element (DOE) is also used to produce a spatially modulated intensity along the vertical direction of the planar illumination. The top of laser sheet is located 2 cm downstream from the injector exit, which ensures that areas where the spray is not fully formed (related to the spray formation region) are not considered.

Fig. 3
figure 3

Scheme of the experimental setup for 3p-SLIPI–polarization ratio measurement. A spatially modulated light sheet is generated by means of a diffractive optical element. The incident light is polarized at a 45° angle using a half-waveplate. Scattered signals are collected by a telecentric lens (positioned at θ = 90°), and images corresponding to parallel and perpendicular polarizations are captured on two cameras using a beamsplitter cube and two polarizing filters

A steady-state water hollow-cone spray, generated by a pressure swirl atomizer (Tetra Pak injector, simplex model, Flow Number = 23 L h−1 bar−1/2), is investigated in atmospheric conditions. Liquid injection pressure is set to 50 bar, which leads to a volume flow-rate of 2.7 L/min for water. Under these injection conditions, the droplet density N [#/m3] is such that multiple light scattering is predominant in the spray, preventing intensity-based measurements without the use of a SLIPI module. Measurements with the same injection system were previously presented by Stiti and co-workers, yielding optical depth (OD) values larger than 1 (Stiti et al. 2023).

The light intensity is modulated using a diffractive optical element (DOE) (Holo/Or, DS-190 532), acting as a light-efficient Ronchi grating. The 3p-SLIPI method is implemented to maintain the spatial resolution offered by the detection setup (Berrocal et al. 2008). Three images, modulated and phase-shifted by 2π/3, must be acquired for the purpose of reconstructing the final image using the 3p-SLIPI method. Each phase is displaced by vertically transferring the DOE using a piezoelectric motor (PiMotor). A zero-order air-spaced λ/2 polarizer (Thorlabs, Half-Wave Plates, WPHSM05-532) is coupled with the 3p-SLIPI device and used to adjust the polarization axis of the incident beam. The polarizer is placed at an angular orientation of β = 45°as a first approximation referring to the previous work of (Bareiss et al. 2013; Stiti et al. 2023). The reception module is placed at a scattering angle of 90°. The scattering signal is recorded using a large telecentric objective (0.066X, 1″ C-Mount TitanTL®), with an aperture angle of Δθ = 5°. As shown by (Garcia et al. 2023), a telecentric lens is used to remove the angular dependence of the scattered Mie signal in the field-of-view: all the light rays collected have a scattering angle θ = 90°. The particularities of a telecentric lens are a fixed magnification at any object distance and a large depth of field. Two sCMOS cameras (Andor, Zyla 5.5) are used and coupled to the lens by a TwinCam module (CAIRN research). The two cameras are synchronized using an Arduino module (Uno Rev3) which receives the acquired data and transmits to the two cameras simultaneously. A 532 nm specific band-pass filter (Thorlabs, FLH0532-1) is fitted on the telecentric lens to filter the TwinCam input signal. A beam splitter cube (Thorlabs, non-polarizing 50/50, BS013) is used to distribute the signal equally between the two cameras. Polarization filters (Thorlabs, LPVISC100b, OD6) are placed in front of each camera and oriented as necessary to collect the required polarization for each sensor.

Various methods can be used to calibrate intensity ratios from planar laser imaging techniques. An ex situ method consists of using a monodisperse droplet generator that accurately controls the droplet diameter in the range of interest (Bareiss et al. 2013; Mishra et al. 2019). Signals from the droplets are recorded sequentially as a function of droplet diameter, and the correlation between intensity ratio and droplet diameter is used for calibration purposes. The major disadvantage of this method is that a monodisperse injection system must be added to the experiments, and the optical setup must be adapted to a much smaller field-of-view. An in situ method consists of creating a calibration function (also called look-up table in our previous article (Garcia et al. 2023)) to relate mean diameter values measured with a PDA system and the intensity ratios deduced from image processing at the same points (Le Gal et al. 1999). The technique is effective, but it requires a second optical diagnostic technique. In this paper, the in situ calibration method is chosen. Thus, PDA measurements are taken using an Artium PDI TK2 to calibrate the polarization ratio and validate the conversion to D21.

3.2 Post-processing routine

The acquisition and post-processing routine for the s-pol and p-pol images is carried out using a custom-made interface developed on the App Designer from MATLAB. All the maps presented in this paper are based on the acquisition and averaging of three modulated images (I0, I120 and I240), where the phase of the sinusoidal modulation of the intensity is shifted by 120° corresponding to a third of the modulation period. For each phase, sixty images using a long exposure time of 80 ms are recorded. The final image of light intensity ISLIPI is obtained using the following equation (Berrocal et al. 2008):

$$I_{{{\text{SLIPI}}}} = \frac{\sqrt 2 }{3} \cdot \sqrt {\left( {I_{0} - I_{120} } \right)^{2} + \left( {I_{0} - I_{240} } \right)^{2} + \left( {I_{120} - I_{240} } \right)^{2} }$$
(6)

Figure 4 shows comparisons between conventional s-pol and p-pol (IConv) and SLIPI (ISLIPI) images. The laser sheet propagates from left to right, and, as can be seen, in both cases the laser signal is attenuated across the spray due to large droplet density. The polarization ratio γ is then reconstructed according to Eq. 5, for IConv and ISLIPI. On IConv, the hollow-cone spray shape characteristic of the injector used in the paper is not observed, whereas this shape is visible on ISLIPI, which demonstrates the benefits of the SLIPI technique in terms of removing the multiple scattering effects.

Fig. 4
figure 4

Averaged s-pol and p-pol images of a hollow-cone spray injecting at 50 bar water spray are produced by capturing three spatial modulated sub-images (show on the right). These images are taken with a 120° phase shift and SLIPI images (ISLIPI) are obtained using Eq. 6. To demonstrate SLIPI’s ability to eliminate the effects of multiple scattering, conventional images (IConv) are obtained using a traditional light sheet technique. Finally, the ratio γ is reconstructed according to Eq. 5

In order to remove the influence of the cameras noise, a “dark” image is defined and applied on each average s-pol and p-pol image. To define a physical scale on each average image, a calibration is then realized (1 px correspond to 0.07 mm). The TwinCam system allows a physical superimposition of the optical paths (error: ± 1 px). The application of the ratio on the whole s-pol and p-pol images produces an aberrant result outside of the spray area, so a mask is defined and applied on the map. A calibration is then applied to the ratio image in order to define the D21 maps. As the injector is mounted on a rotating system (360°), 2D measurements of the polarization ratio at different angles (from 0° to 90° with a 5° step) are recorded, which allows the reconstruction of a 3D spray image. The different planes are then assembled in a 3D matrix, according to a common reference system corresponding to the injection axis. Linear interpolations are then performed between the measurement planes to complete the 3D matrix. The matrix is then exported to the ParaView software which allows the visualization of the results. In this way, spray cross-sections can be deduced from the interpolation of the longitudinal data. For a better understanding, all these operations are summarized in Table 1.

Table 1 Different steps of the post-processing routine

4 Experimental analysis of various polarization angles from the incident light

Recent work (Koegl et al. 2022) has shown that the polarization of the incident light influences the proportionality between the Lorenz–Mie signal and droplet diameter. Further investigation is undertaken here to study the influence of the incident light polarization on the SLIPI–polarization technique. Figure 5 and Fig. 6 present in the left side, different polarization ratio average maps recorded for an injection pressure of 50 bar and different incident light polarization (measurement accurate to β =  ± 1°). To calibrate these polarization ratio average maps, PDA measurements are carried out at three distances from the injector (Z = 50 mm, 70 mm and 90 mm), in order to build the calibration function over the largest possible range of diameters. For each distance, PDA measurements are performed over a half-spray traverse on the incoming side of the laser sheet. Data are acquired every millimeter and are validated when 100,000 droplets are acquired for each measurement point. A maximum diameter gradient can thus be captured on the Y-axis (from 10 to 80 µm). Intensity profiles are then considered at the same Z distances on the polarization ratio image and a cloud of experimental points can be plotted.

Fig. 5
figure 5

Influence of different incident light polarization (β = a 87°, b 70°, c 55° and d 45°), on the polarization ratio. On the left-hand side, different average ratio maps of the water hollow-cone spray, obtained for an injection pressure of Pinj = 50 bar. The laser sheet propagates from left to right. Positions of the PDA measurement volume are displayed at different distances from the injector: Z1 = 50 mm, Z2 = 70 mm and Z3 = 90 mm. On the right-hand side, different calibration functions correlating γ to the surface mean diameter D21 measured by PDA

Fig. 6
figure 6

Influence of different incident light polarization (β = a 35°, b 20°, c 10° and d 3°), on the polarization ratio. On the left-hand side, different average ratio maps of the water hollow-cone spray, obtained for an injection pressure of Pinj = 50 bar. The laser sheet propagates from left to right. Positions of the PDA measurement volume are displayed at different distances from the injector: Z1 = 50 mm, Z2 = 70 mm and Z3 = 90 mm. On the right-hand side, different calibration functions correlating γ to the surface mean diameter D21 measured by PDA

In most studies (Bareiss et al. 2013; Stiti et al. 2023) the incident light polarization that is experimentally employed is oriented at β \(\approx\) 45° in order to equalize the vertical and horizontal components of the illumination. As seen in Fig. 5d, for diameters below D21 = 30 μm, γ values exhibit limited discrepancy, whereas above this diameter, a large discrepancy is observed that increases with diameter (for example, at D21 = 60 μm the polarization ratio method gives a γ range from 1.5 to 3). To investigate this phenomenon, different angles are imposed on the incident light polarization, in order to obtain an optimal configuration where the polarization ratio linearly varies with D21. For β = 90° (s-pol), the vertical component of polarization is detected; while for β = 0° (p-pol), the horizontal component of polarization is detected.

In Fig. 5, for β > 45° (mostly s-pol signal), the relationship is not bijective, which prevents any calibration. However, the absolute value of the measured ratio is larger than for β = 45°: at β = 55° (Fig. 5c), the maximum value is 6.5, increasing to 14.5 at β = 70° (Fig. 5b). This tendency can be explained by the fact that for β > 45°, the majority of the received polarization is perpendicular. As numerically demonstrated by (Stiti et al. 2023), when the incident light polarization is unbalanced between s-pol and p-pol, the dominant polarization influences the mean value of the ratio and its fluctuations. Here, the dominant polarization is the s-pol, and as observed in Fig. 1, for a given diameter, the mean intensity and its fluctuations are larger than those for the p-pol. Furthermore, as shown in Fig. 2, there is an effect of the distribution shape on the ratio value, which increases with D21. As shown in Fig. 7, three shapes of droplet size distributions were measured by PDA. Each distribution has the same D21 = 60 μm, although measured at three different Z distances from the injector. The results illustrate a log-normal shape at distance Z = 50 mm and two bimodal shapes for Z = 70 and 90 mm. The significant variations in the ratio observed with a D21 > 60 μm for the calibration function in Fig. 5d may also be potentially related to the change in the distribution shape. It is therefore advisable to conduct PDA measurements on each new spray to quantify the error associated with the shape of the distribution. Finally, when the incident signal is almost perpendicular (Fig. 5a), the trend reverses, and the result becomes aberrant: the smallest ratios correspond to the largest diameters.

Fig. 7
figure 7

Different droplet size distributions obtained for the same D21 = 60 μm at different distances from the injector: Z = 50 mm, 70 mm and 90 mm

Taking things further, angles of β < 45°, where the polarization is mostly parallel, are then tested (Fig. 6). As a result, the relationship between ratio and diameter tends to become bijective and discrepancy of the ratio is significantly reduced for large diameters. In addition, there is a considerable decrease of the ratio for β < 45°, due to the higher proportion of p-pol. For example, for D21 = 20 µm a ratio of 1.5, 0.55 and 0.1 is observed, respectively, for a β value of 35°, 20° and 10° (Fig. 6a–c). However, a large experimental uncertainty remains for large diameters: for example, in the case of β = 35°, the error on D21 is ± 2 μm for γ equal to 0.5 and increases to ± 20 μm for γ equal to 1.2 (Fig. 6a). As the relationship is bijective for β < 45°, several calibration functions can be fitted, starting close to 0 because in theory, when D21 = 0 μm, the polarization ratio γ = 0. Consequently, the calibration function is established based on a linear equation originating close to 0, aiming to encompass a broader range of data within the curve. This linearity in the observed correlations is highly interesting compared to the nonlinear trends identified in the LIF/Mie technique (Koegl et al. 2018a, b; Garcia et al. 2023). Indeed, a linear law means that the measurement uncertainty remains constant, and the ratio between small and large diameters remains proportional. From this calibration function, a relative error (RE) of the D21 measurement can be calculated as follows for each diameter bin:

$${\text{RE}} = \frac{{\left| {\overline{M}_{{{\text{th}}}} - \overline{M}_{{{\text{exp}}}} } \right|}}{{\overline{M}_{{{\text{th}}}} }}$$
(7)

with \(\overline{M}_{{{\text{th}}}}\) representing the mean value of the ratio obtained from the calibration function and \(\overline{M}_{{{\text{exp}}}}\) representing the mean value of the ratio obtained from the experimental measurement.

The results are summarized in Fig. 8 for each diameter bin and each incident light polarization value. For β = 45°, a small relative error is observed within the diameter range of [10–30 µm], but the value increases significantly above 30 µm. For β = 35°, the maximum relative error gives less than 6.8% between 10 and 40 µm, but beyond that, the data no longer follow the linear trend. For β = 20° and 10° (Fig. 6b, c), the results show an improvement in linear trends and less discrepancy in measurements for a given diameter. However, there is still a decrease of the ratio, which varies from 0.05 to 0.35 for a diameter range from 10 to 70 µm (Fig. 6c). The variation in β from 35° to 10° reduces the measurement relative error for each diameter bin, and the best result is obtained for β = 10°: a maximum relative error of 5.6% is observed in the range 10–70 µm. Unlike with the previous incident light polarization, here the experimental data exhibit a linear evolution across the entire data range [10–70 µm]. For this incident light polarization, the particle size distribution had no impact on the value of the ratio. Additionally, the dynamic ratio is sufficient for accurate measurements: the value of the ratio is multiplied by a factor 3 in the range of interest. For β < 10° (Fig. 6d), the diameter range where the relationship is linear decreases to [10–40 µm] and the relationship becomes nonlinear above that limit. Finally, the best result is obtained for β fixed at 10°, allowing a low relative error together with a good sensitivity of the polarization ratio measurement. The calibration function can be fitted and written: γ = 0.0044 D + 0.0108.

Fig. 8
figure 8

Variation in the relative error of the results observed per D21 range, for each incident light polarization tested

These experimental results confirm the modeling data given in (Stiti et al. 2023) which demonstrates that when the s-pol signal prevails, the fluctuation of the polarization ratio around the simulated D21 values is very strong. Conversely, when the p-pol signal dominates, the fluctuation is significantly attenuated. In the experiments conducted here, the ratio decreases when the p-pol signal prevails, yet the loss of linearity in the calibration function remains unexplained.

5 Experimental analysis of various refractive indices from the injected liquid

When considering a sphere whose diameter is much larger than the wavelength, Van de Hulst stated that most of the scattering angular pattern could be interpreted in terms of diffraction, refraction and reflection (Van de Hulst 1981). It is therefore implicit that any change in the properties of the liquid will modify electromagnetic properties such as permeability and permittivity, which affects the reflection, refraction and diffraction behavior of light in droplets. For this reason, it is important to study the influence of refractive index on the polarization ratio technique.

5.1 Real part of the refractive index (nr)

With a single water droplet (n = 1.33 + 0i), the polarization ratio technique can be used for a scattering angle in the 75–115° range, but beyond this limit, the ratio becomes uniform and no longer varies as a function of droplet size (Massoli et al. 1989). Extensive work was performed by Hofeldt, in which polarization ratios were calculated for different refractive indices at a scattering angle θ = 90° (Hofeldt 1993a; b). The results show that under these scattering conditions, the technique is applicable up to a real refractive index of nr = 1.40, but above this value, the polarization ratio varies very little with droplet size.

Experimental investigation of the dependence of the polarization ratio on the real part (n) of the refractive index is carried out by gradually adding glycerol (Sigma Aldrich G9012) to water. For example, 20% of glycerol in water corresponds to a refractive index of nr = 1.36 and 40% of glycerol yields a refractive index of nr = 1.38. As the viscosity of glycerol is much higher than that of water (µglycerol = 1.49 Pa.s ,whereas µwater = 1E-3 Pa.s), the proportion of glycerol in water is limited to a maximum of 60%, which corresponds to a real refractive index nr = 1.41. This ensures that the water/glycerol mixture still atomizes properly. The real refractive index is then measured for each solution with an Abbe refractometer (ATAGO, DR-M2 & DR-M4). According to (Ren et al. 2012), at a wavelength of 532 nm, the imaginary part of the refractive index of the Glycerol can be considered as zero. Figure 9 presents the experimental polarization ratio obtained for different real parts of the refractive index: nr = (a) 1.36, (b) 1.38 and (c) 1.41.

Fig. 9
figure 9

Average polarization ratio maps for different real refractive indices: n = a 1.33 + 0i, b 1.36 + 0i, c 1.38 + 0i and d 1.41 + 0i, obtained for an injection pressure of 50 bar. The laser sheet propagates from left to right and the scattering angle is fixed at 90°. For each map, PDA measurements are realized at a distance Z = 70 mm from the injector

A drawback of this process is that adding glycerol to water leads to increased values of viscosity and surface tension. As a result, the particle size increases with glycerol concentration for a fixed injection pressure. In order to take account of these variations, PDA measurements are conducted for each refractive index and recorded at a distance Z = 70 mm from the injector. Results are shown in Fig. 10 (cf. experimental calibration curve) and a linear calibration function is fitted for each refractive index. The experimental results confirm the simulation performed by (Hofeldt 1993a), which showed that for a 90° observation angle of a polydisperse spray, the sensitivity of the ratio decreases with increasing refractive index. For a refractive index of 1.33, the ratio dynamics varies by a factor of 5 over a diameter range extending from 10 to 70 μm, whereas a factor of 7 is observed experimentally (Hofeldt 1993a). In contrast, for a refractive index of 1.41, Hofeldt reported a factor of 2 for the same diameter range (10–70 μm), which is similar to our experimental results. For a refractive index of n = 1.33 + 0i, the technique is therefore more sensitive and the sensitivity of the technique decreases with increasing index. It has been numerically demonstrated that for a refractive index of 1.45, the slope becomes zero above a droplet diameter of 40 μm, making particle size measurement impossible using the polarization ratio technique. For the experimental results obtained in this paper, the value of the slope changes from 0.0057 for a refractive index of 1.33 to a value of 0.0022 for a refractive index of 1.41. So, despite the low dynamic intensity of the ratio, the measurement is still applicable for a real refractive index value of 1.41.

Fig. 10
figure 10

Experimental and numerical linear evolutions of the polarization ratio γ as a function of the surface mean diameter D21, for different real refractive indices. An observation angle is set to 90° and the slope (p) is defined for each refractive index. In the case of the experimental results, D21 has been measured by PDA at Z = 70 mm (refer to Fig. 9) and the incident light polarization β = 10°. Six droplet size distribution (PDF) obtained by PDA were used as inputs for numerical simulations, each of them attributed to a 10 μm range of D21: the first one for [10–20 μm], the second one for [20–30 μm], the third one for [30–40 μm], the fourth one for [40–50 μm], the fifth one for [50–60 μm] and the sixth one for [60–70 μm]

To confirm the trends observed experimentally, MiePlot simulations are carried out under the same conditions and results are also displayed in Fig. 10. Six droplet size distributions were acquired with PDA. Each distribution is valid for a 10 μm range of D21: the first one for [10–20 μm], the second one for [20–30 μm], the third one for [30–40 μm], the fourth one for [40–50 μm], the fifth one for [50–60 μm] and the sixth one for [60–70 μm]. The six distributions were then used to define the mean values of D21 in the simulation. From these values, a numerical trend curve is reconstructed, and this process is repeated for each refractive index. The results show a linear relationship between the ratio and the mean diameter, as well as a decrease in the value of the slope for an increase of the refractive index. Nevertheless, although the experimental and numerical slopes are quite similar for a refractive index of 1.33 and 1.36, differences can then be observed for the other refractive indices. Indeed, for a refractive index of n = 1.38 + 0i, the experimental curve yields a slope of p = 0.0046 compared to a numerical slope of 0.0037. Conversely, for a refractive index of n = 1.41 + 0i, the experimental slope (p = 0.0022) is lower than the numerical one (p = 0.0029). It has to be noted that experimental results are limited to n = 1.41 + 0i and further investigations are required for larger refractive indices in order to verify that the slope tends toward zero.

Finally, the polarization ratio technique is applied for quantitative measurements of droplet size. The different polarization ratio mappings obtained in Fig. 9 for the three mixtures of water and glycerol are converted to D21 mapping. The results are presented on the left-hand side in Fig. 11. On the right-hand side, a comparison is made with PDA data, taken at the distance Z = 70 mm from the injector. PDA measurements are conducted along a half-spray traverse on the incoming side of the laser sheet. Data points are collected at every two-millimeter interval, and validation is ensured with the acquisition of 100,000 droplets for each measurement point. This approach allows us to capture a maximum diameter gradient on the Y-axis, ranging from 10 to 80 µm. As shown in Fig. 11, for the same injection pressure, the addition of glycerol in certain proportions affects the spray droplet size. Increasing the concentration of glycerol, which is more viscous than water, leads to an increase in droplet size for a fix injection pressure of 50 bar. In the case of water + 20% glycerol (Fig. 11a), the maximum D21 obtained is 60 µm at the edges. In contrast, when injected with water + 60% glycerol (Fig. 11c), the D21 exceeds 80 µm at the edges. This is confirmed by comparisons with PDA data, which show a measurement error of less than 4.4% for all mixtures.

Fig. 11
figure 11

On the left-hand side, different D21 mappings, obtained for different refractive index: a n = 1.36 + 0i (water + 20% glycerol), b n = 1.38 + 0i (water + 40% glycerol), and c n = 1.41 + 0i (water + 60% glycerol). On the right-hand side, comparison is realized between SLIPI–polarization ratio and PDA measurements of D21. The average relative error is given for each case

5.2 Imaginary part of the refractive index (k)

The effects of the imaginary part of the refractive index need to be assessed in order to further investigate its influence on the polarization ratio. Some researchers have studied numerically the absorption effect on the polarization ratio technique and demonstrated that the Lorenz–Mie ripples are progressively damped as absorption increases (Beretta et al. 1985). Additional MiePlot simulations have been performed (Fig. 12), for the following experimental conditions: a scattering angle of 90° (with an aperture angle of Δθ = 5°), a center wavelength of λ = 532 nm, a real refractive index of nr = 1.33 and a polydisperse droplet size distribution following a log-normal law (standard deviation of 20% and using 20 points to build the distribution), with a diameter resolution of ΔD = 0.05 μm. As seen in the differences between Fig. 12a, b, increasing absorption significantly reduces the Mie ripples, which confirms the results from (Beretta et al. 1985). Figure 12c presents the influence of the absorption on the polarization ratio: first, it appears that the increase of the absorption does not damp the ratio dispersion. The slope then increases with absorption, which leads to an improvement of the measurement accuracy.

Fig. 12
figure 12

MiePlot simulation of the scattered intensity (s-pol and p-pol) function of the surface mean diameter, for two imaginary refractive indices where k = 0 in (a) and k = 0.001 in (b). The simulated conditions are similar to the experimental ones: a polydisperse spray, a scattering angle θ = 90° with an opening angle Δθ = 5°. Finally, the ratios are obtained numerically and displayed on (c)

Finally, the relationship between ratio and mean diameter remains linear up to an imaginary index of k = 0.001, but for an index of k = 0.002 the relationship is no longer linear. In this case and for a range of diameters from 50 to 80 μm, the ratio becomes almost independent of the diameter, which means that the technique is no longer suitable for droplet sizing. This shows that although it is tempting to increase absorption in order to decrease Mie ripples, the sensitivity of the polarization ratio is then reduced and limits the applicability of the technique.

6 Tomographic 3D reconstruction of water spray

In this last section, an average tomographic 3D map of D21 is obtained for a hollow-cone spray generated by the Tetra Pak injector, with an injection pressure of 50 bar. The result is obtained according to the method described in Table 1 and are presented in Fig. 13. On the top, different D21 half mappings used for 3D reconstruction are shown. On the middle, the 3D reconstruction method and the average 3D map of D21 are presented, while on the bottom, three cross-sections are derived from the 3D results, at distance Z1 = 50 mm, Z2 = 80 mm, and Z3 = 110 mm. All the D21 map used in the 3D reconstruction are obtained by applying the calibration function to convert the polarization ratio images into diameter. The results are obtained with an incident light polarization oriented at β = 10°, as recommended in the previous section (see Fig. 6c and γ = 0.0044 D + 0.0108). On Z-axis, the 3D map starts 50 mm downstream from the injector, where the droplets are well formed, and the Lorenz–Mie theory is applicable. At first sight, the spray appears to be symmetrical about the injector axis: larger droplets are present at the edges of the spray, whereas the smallest ones are present in the center. The hollow cone clearly appears and the D21 varies between a minimum value of 10 μm in the center and more than 80 μm at the edges. The reconstruction of a 3D map from several longitudinal 2D planes allows to obtain transverse 2D planes.

Fig. 13
figure 13

On the top side, different D21 half mappings are realized at different angle of the spray. These mappings are then used for the 3D reconstruction as described in in Table 1. On the middle of the figure, an average three-dimensional map of surface mean diameter D21 reconstructed using 2D maps is presented. The results are obtained for an injection pressure of Pinj = 50 bar. On the bottom side, three cross-sections are extracted on the studied spray, from the 3D reconstruction at distance Z1 = 50 mm, Z2 = 80 mm and Z3 = 110 mm

7 Conclusion

This paper presents an analysis of the experimental parameters influencing the application of the SLIPI–polarization ratio technique in sprays. It was first demonstrated numerically that the Lorenz–Mie ripples could be attenuated by the polydispersity of the spray, making the technique suitable for the particle sizing of an entire spray. Second, the analysis of experimental parameters has been investigated. The main results of this study can be summarized as follows:

  • It was found that the PDA calibration of the SLIPI–polarization ratio technique becomes fully linear for droplets between 10 and 70 μm, when the illumination has an incident linear polarization set to 10° and 20°.

  • The influence of the complex refractive index was then studied experimentally and numerically. On the one hand, the experimental results showed that for an observation angle of 90°, the technique loses its measurement sensitivity when the real refractive index increases from 1.33 to 1.41. Above 1.41, it is believed that the technique may becomes hardly applicable for this 90° scattering angle detection. On the other hand, simulation results showed that for refractive indices above 1.41, the technique is still applicable but with a different scattering angle detection (i.e., for nr = 1.41 the most appropriate scattering angle would be 110°).

  • A second numerical study was carried out to investigate the influence of the imaginary part of the refractive index (related to absorption) on the polarization ratio technique. The results showed that as the absorption effects increase, the Lorenz–Mie ripples tend to disappear. However, the relationship between D21 and the ratio becomes nonlinear.

  • After converting the polarization ratio into D21 via calibration, further characterizations were carried out on sprays of water mixed with a certain proportion of glycerol (20%, 40% and 60%). These results demonstrated the reliability of the technique, giving an average relative error of less than 4.5% compared with PDA measurements.

  • Finally, a 3D reconstruction of the spray diameter D21 was performed via tomography, enabling the overall symmetrical characterization of a hollow-cone atomizing spray that is typically used in the industry.

To conclude, SLIPI–polarization ratio provides accurate droplet sizing in 2D, in optically dense sprays. In addition, the applicability of the technique is very promising in warm and highly evaporating sprays, due to the fact that no additive dyes are needed for such measurements.