1 Introduction

The spray formation controls the combustion process of IC engines in terms of pollutant emissions, efficiency and consequently CO2-emissions. The atomization and mixture formation processes of gasoline direct injection spark ignition (DISI) engines are very complex. Atomization and mixture formation are mainly governed by the thermo-physical properties of the fuel and they affect subsequent processes like the soot formation essentially (Chen and Stone 2011; Shirazi et al. 2019; Storch et al. 2015; Koegl et al. 2019a).

The usage of alternative biofuels like ethanol and butanol may contribute to an effective reduction of the CO2-emissions, but their utilization could rise the complexity of the mixture formation and combustion processes. Previous studies showed that an ethanol admixture to gasoline could lead to a soot reduction of DISI-engines, which is mainly caused by the chemical fuel properties (Fournier et al. 2016; Storch et al. 2014). Under certain conditions, however, an ethanol admixture to gasoline can result in more distinct soot formation of a DISI-engine (Chen and Stone 2011; Storch et al. 2014, 2015; Koegl et al. 2018a). This is caused by the different atomization and evaporation behavior due to the fuels’ physical properties. Especially the increased surface tension and liquid fuel viscosity may increase the resistance to droplet breakup (Shirazi et al. 2019). The viscosity of gasoline rises by up to 20% for addition of 15 vol.% alcohol (Christensen et al. 2011). However, under DISI conditions studied in an injection chamber, the effect of viscosity of different fuel components on atomization was not significant. Zigan et al. (2010) reported variations in SMD of just 5–7% when the liquid viscosity was varied by a factor of about 2. In this case, different single component fuels were studied at low ambient temperature (293 K, 1.5 MPa). However, there are no systematic experiments available on the atomization behavior of gasoline-ethanol blends.

Knorsch et al. (2013) found a larger Sauter mean diameter (SMD) for ethanol droplets as compared to isooctane under conditions with high evaporation rate (0.8 MPa ambient pressure and at 673 K gas temperature). This can be explained by the fact that ethanol admixture leads to an increase of the evaporation enthalpy of the fuel mixture. This could result in a decrease of the evaporation rate with increasing ethanol content and worse mixture preparation. Storch et al. (2016a) conducted a mixing study in a transparent DISI engine under late injection timing conditions and found a very similar mixture for isooctane and E20 (consisting of isooctane and 20% ethanol). Partially, for E20 even a higher probability of fuel-rich zones was found compared to isooctane, while E85 (containing 85% ethanol) and pure ethanol again lead to leaner mixtures. It was concluded that the mixture formation was controlled by the evaporation enthalpy of ethanol. However, effects of atomization could not be separated so that further experiments are necessary to understand the complex process chain.

Non-invasive optical techniques are suitable to allow for further optimization of injection and spray processes. 2D diagnostics are preferable as they provide insights into the complex spray structure. Especially, the droplet size is an essential quantity to describe sprays, and manifold approaches have been proposed to enable a 2D measurement in sprays. Measurement techniques like shadowgraphy are used for droplet sizing in dilute spray regions (Welss et al. 2018; Moon et al. 2005), and also interferometric Mie Imaging (IMI) (or Interferometric Mie Imaging for Droplet Sizing, ILIDS) is employed (Kawaguchi et al. 2002; Mounaïm-Rousselle and Pajot 1999). Other planar droplet sizing techniques are based on the LIF/Mie-ratio (Gal et al. 1999; Domann and Hardalupas 2001a,b, 2003; Domann et al. 2002; Frackowiak and Tropea 2010a,b; Charalampous and Hardalupas 2011a,b; Koegl et al. 2018b), which is a combination of laser-induced fluorescence (LIF) and Mie-scattering (Mie), the LIEF/Mie ratio (LIEF—laser-induced exciplex fluorescence) (Zeng et al. 2013) or the Raman/Mie ratio (Malarski et al. 2009).

The LIF/Mie ratio technique can be utilized for spray characterization in terms of determination of the SMD (Sauter mean diameter). The LIF/Mie ratio technique is based on the volumetric dependence (d3) of the LIF-signal and the square dependence (d2) of the Mie-signal (which is proportional to the droplet surface) of droplets illuminated with a laser light source (Gal et al. 1999; Domann and Hardalupas 2001a,b, 2003; Domann et al. 2002; Frackowiak and Tropea 2010a,b; Charalampous and Hardalupas 2011a,b; Koegl et al. 2018b). The LIF- and the Mie-Signals SLIF and SMie as a function of the droplet diameter ddroplet can be expressed by the following equations (Gal et al. 1999):

$$S_{{{\text{LIF}}}} = a_{{{\text{LIF}}}} \times d_{{{\text{droplet}}}}^{{3}}$$
(1)
$$S_{{{\text{Mie}}}} = a_{{{\text{Mie}}}} \times d_{{{\text{droplet}}}}^{2}$$
(2)

Experimental parameters like the laser fluence and the collection angle are included by the constants aLIF and aMie. Mie-exponents above two are possible due to morphology-dependent resonance (MDR) effects. The LIF-exponent shows a strong dependence on the absorption of the liquid solution. A low absorption leads to exponents of three according to the literature, while stronger absorption may lead to a decrease of the exponent down to two (Gal et al. 1999).

The initially qualitative LIF/Mie ratio must be calibrated using additional measurement techniques to image the SMD in the spray. phase-Doppler anemometry (PDA) measurements in the same spray (Koegl et al. 2019a; Gal et al. 1999) or monodisperse droplet LIF/Mie measurements with a droplet generator (Domann and Hardalupas 2001b; Koegl et al. 2018b,c) are usually applied for that purpose. Single droplet LIF/Mie data is advantageous for calibration of instantaneous spray images as the data is applicable for other spray systems as well. Furthermore, the same detection system can be used for calibration in a droplet chain and the actual spray measurements. Averaged PDA data acquired in the same spray is not universally applicable and may introduce large measurement uncertainties (e.g. in transient sprays or intermittent injections) as these sprays may show large cyclic variations in spray shape and SMD. However, when using a droplet generator, it must be able to produce a wide range of droplet sizes that are relevant for the respective spray.

The LIF-signal can either be created by the aromatic components of a multi-component fuel itself (Park et al. 2002) or by adding a dye to the fuel (Koegl et al. 2019a; Mishra et al. 2014). Aromatic hydrocarbons, which are present in commercial automotive fuels at high percentages, absorb laser light within the UV region. A visible wavelength should be preferred for excitation of the dye in order to avoid interference with fluorescence of excited fuel components, which may falsify the data.

Many investigations on droplet sizing using LIF/Mie ratio in alcohol or water sprays already exist in the literature (Koegl et al. 2018b,c, 2019a; Mishra et al. 2014, 2017, 2019; Storch et al. 2016b). The tracer Eosin Y, which was mainly used in the previous studies, is not soluble in alkanes or gasoline fuels (Durst et al. 2018). The tracer options for alkanes, oils and gasoline are more limited and mainly pyrromethene and its derivatives (e.g., 597-8C9, 597-C8) are applied, but the fluorescence strongly depends on temperature so that this dye is mainly used for thermometry (Depredurand et al. 2008, 2010; Palmer et al. 2018). The tracer Nile red (C20H18N2O2) is one promising tracer, which is commonly used in microfluidic and in biology applications (Zhang et al. 2018; Lin et al. 2014; Greenspan and Fowler 1985). It is also soluble in real-world fuels (Durst et al. 2018). The fluorescence signal of Nile red was already characterized in combination with various fuels (Koegl et al. 2019b). Furthermore, the impact of ethanol admixture on the respective LIF and Mie signals of monodisperse gasoline droplets of a droplet generator were also studied in a previous work of the authors (Koegl et al. 2019c). The droplets were investigated at relevant DISI engine conditions with sizes from 20 to 50 µm. The individual LIF- and Mie-signals were applied to deduce SMD calibration curves depending on dye concentration, laser-fluence, temperature and fuel composition (Koegl et al. 2019c). Major challenges of using dyes for LIF/Mie droplet sizing are its varying concentration during evaporation and related temperature changes, which may introduce large errors in SMD. So far, only few studies (Koegl et al. 2018b, 2019a) exist that address these issues, but no systematic investigation has been conducted for gasoline sprays and gasoline-ethanol blends. Consequently, effects of the evaporation on the measurement uncertainty of PDS are quantified in the framework of the present study for the first time.

In the present study, the spray formation of gasoline-ethanol fuel blends is studied in a constant volume chamber with the LIF/Mie ratio technique. For this purpose, the PDS-technique is combined with 2-phase structured laser illumination planar imaging (SLIPI) to reduce effects of multiply scattered light in denser spray regions [for details see (Koegl et al. 2019a; Mishra et al. 2017; Storch et al. 2016b)]. The LIF/Mie results are calibrated with the respective single droplet data of a droplet generator (Koegl et al. 2019c). Afterwards, the fuel-dependent spray structure is described in terms of the SMD, and the data is compared to point-wise PDA-measurements. Fuel effects on spray formation are described for a gasoline surrogate fuel (“Toliso” consisting of isooctane and toluene) and a blend with ethanol (E20). The limitations of the presented LIF/Mie-technique under conditions with low evaporation rate (gas and fuel temperature 293 K, injection pressure 16 MPa, chamber pressure 0.2 MPa) are presented. For this purpose, a numerical simulation of the single droplet evaporation process is provided as well, which describes different sources of error (such as temperature and dye concentration effects) on the accuracy of the PDS technique. Critical time scales are estimated when evaporation effects play a significant role under the present injection conditions. The effect of the evaporation rate on the accuracy is also determined for various base fuels, which show different boiling points and evaporation enthalpies.

2 Experimental and numerical setups

2.1 Planar droplet sizing using SLIPI-LIF/Mie

The DISI-sprays are analyzed in a constant volume chamber (CVC) with the 2p-SLIPI-technique (Storch et al. 2016b). The experimental setup for the simultaneous detection of the LIF- and Mie-signals of laser-illuminated fuel sprays is shown in Fig. 1. The technique uses two modulated sub images with a 180° phase shift to suppress multiply scattered light. The two laser pulses for the SLIPI technique are generated by a Thales laser cluster (Nd:YAG, 532 nm, pulse duration 6 ns, top hat beam profile, height: 115 mm, thickness: 0.4 mm, laser fluence: 48 mJ/cm2). The modulation is generated by a square Ronchi grating leading to lines with 0.35 mm height with an equidistant spacing of 0.7 mm in the spray. The spatial phase shift is generated by a calcite crystal and two cross-polarized laser beams. The horizontally polarized laser pulse passes through the crystal and maintains the same path (ordinary ray), while the vertically polarized laser pulse is displaced (extraordinary ray) (Storch et al. 2016b). The spatial shift is determined by the thickness of the calcite crystal. A detailed description of the working principle of 2p-SLIPI and the setup can be found in references (Storch et al. 2016b; Mishra et al. 2019). The LIF and Mie signals are recorded simultaneously using a specially designed objective system, which is equipped with a macroscopic objective (135 mm, 2.8/135, Pentacon, Germany). The signal is spectrally divided by a beam splitter (Transmission: 70% LIF, 30% Mie) just after the objective, and the individual signals are recorded with two identical double-shutter sCMOS cameras (LaVision GmbH, Germany; 2560 × 2160 pixels, nominal pixel resolution 37.3 µm/pixel). The LIF and Mie signals are detected in different spectral regions by using appropriate filters [LIF: 532 notch filter, 17 FWHM; Mie: 532 nm laser line pass filter (1 nm FWHM)], which are mounted in front of the cameras. To optimize the signal detection at constant laser power and at different observation time points, motorized filter wheels equipped with a set of ND-filters (ND 0, ND 0.3, ND 0.6, ND 1, ND 1.3) are mounted in front of the individual cameras. The cameras are operated in double-shutter mode for 2-phase SLIPI. The time delay between the laser pulses and the two sub images is 0.75 µs to freeze the spray motion. The five-hole solenoid DISI injector (BOSCH, Germany) with the corresponding spray targeting is shown in Fig. 2.

Fig. 1
figure 1

Experimental setup for the simultaneous detection of the optical LIF and Mie signals of laser illuminated fuel sprays

Fig. 2
figure 2

Five-hole solenoid DISI Injector with detailed spray targeting regions

The injector has a bore diameter of 168 µm and a length-to-diameter ratio (l/d) of 1.7. The injection pressure is 16 MPa and the injection duration is 1.8 ms. The section A–A, which is located 20 mm beyond the nozzle, presents the spray interaction with the neighboring spray plumes. The center plume is separated from the remaining plumes, which allows unrestricted optical access. This central plume shows less jet-to-jet interactions, so that it is analyzed in the framework of this study. The operating conditions of the constant volume chamber for the spray measurements performed in this study are displayed in Table 1.

Table 1 Operating conditions of the CVC chamber

2.2 PDA-measurement setup

The PDS-measured SMDs are compared to point-wise PDA-measurements. For this purpose, the injector is transferred to a PDA-equipped injection chamber. The PDA system used is a FiberPDA (Dantec Dynamics A/S) combined with an Innova 305C laser (Coherent Inc.). The four laser beams were overlapped in an intersection volume by a transmitter optic using a 310 mm collimating lens. The resulting probe volume has a length of 468 µm and a diameter of 45 µm. The probe volume contains 15 fringes with a corresponding fringe spacing of 2.67 µm. This configuration enables a droplet size detection up to 60 µm. The probe volume is positioned within the fuel spray using a 3-D linear stage. The signal bursts are detected with an optical receiver with a 310 mm collimating lens and an aperture for small particles. The aperture used limits the effective length of the measurement volume to 50 µm. Signal detection is performed under the Brewster angle of 70°. This detection setup is less sensitive to changes in the refractive index due to different fuels and varying droplet temperatures.

The SMD is determined at various positions within the fuel spray. A reliable droplet determination with the LIF/Mie technique or PDA is not possible near the nozzle (< 10 mm) due to the presence of non- spherical droplets and ligaments, which are caused by droplet deformation, secondary break-up and coalescence. To be able to investigate a large radial area, droplets with a distance of 40 mm to the nozzle and more are taken into account for the validation. For each measurement position, 120 injections are evaluated, which results in about 30,000–50,000 validated droplets per position.

2.3 Numerical simulation

A simulation of evaporating single droplets was conducted in Matlab®. It is employed for the assessment of the experimental results and especially for an uncertainty analysis of the PDS-technique. The applied 1-D diffusion limited model (DLM, convective, non-ideal) considers the internal heat and mass diffusion, i.e. the temporal and spatial gradients of the properties of the liquid mixture (Keller et al. 2013). The model describes the diffusive transport but neglects convection inside the droplet (internal circulations), which is usually covered by “effective diffusivity models” (EDM). The other extreme is the “rapid-mixing model” (RMM) assuming infinitely fast diffusion. The “true” evaporation characteristic is expected between the two extreme cases of DLM and RMM (Wilms 2005). Under the present injection conditions, the results of the RMM and DLM are very similar and are given in the appendix. Consequently, only results of the DLM are given in the results section of the paper for brevity.

The model uses an adaptive time step while holding the change in temperature and mass constant. The thickness of each shell is kept constant at around 1 µm. The number of shells decreases with the size of the droplet as evaporation occurs. The vapor–liquid equilibrium is calculated using a non-ideal γφ model assuming thermodynamic equilibrium at the droplet surface. In this model, γ is the activity coefficient and φ is the liquid fugacity coefficient for pure components. The activity coefficients are calculated using the UNIFAC (universal quasi-chemical functional group activity coefficients) group contribution method. Consequently, this model considers effects of demixing of the fuel components and preferential evaporation on the droplet composition, which is an important information for discussion of the uncertainty of the measurement technique in case of evaporation. This is especially important as preferential evaporation may occur for ethanol-isooctane blends (Bader et al. 2013). Convection in the gas phase is considered by the Frossling correlations of the Nusselt number and Sherwood number (Abramzon and Sirignano 1989). The droplets are described by a constant velocity of 20 m/s, which is a typical average value for DISI conditions in the studied spray zones (see, e.g., reference (Heldmann et al. 2015) for this specific injector). This means that effects of air drag and droplet deformation are not considered. The numerical boundary conditions match the real boundary conditions in the injection chamber (see Table 1), except of the definition of the ambient gas for which nitrogen is applied instead of air.

It should be noted that this model describes only isolated single droplets. This is of course a simplification since the evaporation in a dense spray is affected by the interaction of neighboring droplets and vapor. Consequently, the predicted evaporation rate of the isolated droplet is larger than in the dense spray. Thus, the simulation is a worst-case scenario and the resulting dye concentration in the droplet would be over-estimated for a given droplet lifetime. The model used thus gives an upper bound for the uncertainty.

2.4 Applied fuels and tracers

The sooting tendency of commercial gasoline is mainly driven by its aromatic components like toluene, benzene or xylene etc., which match up to 35 vol.%. Toluene is known as octane-number enhancer in gasoline with concentrations of up to 15 vol.% (Burri et al. 2004). Toluene is an aromatic hydrocarbon and mixtures with isooctane and n-heptane lead to a similar sooting behavior as for commercial gasoline (Choi et al. 2011). In accordance with our previous studies (Koegl et al. 2018a,2019d; Storch et al. 2016c,d) and to avoid compositional variations of gasoline, the two-component surrogate fuel Toliso (65 vol.% isooctane, 35 vol.% toluene) was used in this work. Toliso has similar thermo-physical properties as multi-component gasoline. The effect of biofuel admixture was considered by blending Toliso with 20 vol.% of ethanol (E20). The chemical and physical properties of the investigated fuels for various ambient conditions are shown in Table 2.

Table 2 Physical and chemical properties of the investigated fuels (Dean 1999; Bronkhorst 2019; GmbH et al. 2011; Wang et al. 2006; Luning Prak et al. 2014; Reichardt and Welton 2010; Schirmer 1990)

While it may be assumed that the fluorescence tracer Nile red (C20H18N2O2, Sigma Aldrich) added does not significantly change the fluid properties of the fuels, the different fuels may affect the fluorescence of the dye. To achieve a good signal to noise ratio, the fuel for the droplet investigations was doped with 100 mg/l Nile red. The dye nile red belongs to the group of fluorophores and its aromatic ring structure contains polar substituents. These properties lead to a high sensitivity to the chemical and physical environment of surrounding solvent molecules (Kalathimekkad et al. 2015). Consequently, the polarity of the fuel (see Table 2) will affect the fluorescence and the LIF/Mie ratio, which could potentially influence the accuracy of the technique.

The fuel properties of Toliso (or isooctane and toluene, respectively) match those of gasoline quite well; especially viscosity, surface tension and heat of vaporization are very similar. As mentioned above, ethanol addition will lead to an increase of viscosity and surface tension, which could affect atomization. Thus, the fuel dependent Weber numbers We and Reynolds numbers Re are provided to estimate the resulting SMD values according to the model of Hiroyasu and Arai (1990). The Weber and Reynolds numbers are defined as follows:

$${\text{Re}} = \frac{{d_{{{\text{Nozzle}}}} \times \rho_{{\text{F}}} \times u_{{{\text{Nozzle}}}} }}{{\eta_{{\text{F}}} }}$$
(3)
$${\text{We}} = \frac{{d_{{{\text{Nozzle}}}} \times \rho_{{\text{F}}} \times u_{{{\text{Nozzle}}}}^{{2}} }}{{\sigma_{{\text{F}}} }},$$
(4)

where dNozzle is the nozzle diameter, and uNozzle is the initial velocity at the nozzle. The relevant fuel properties are the fuel density ρF, the surface tension σF and the dynamic viscosity ηF. The resulting SMD can be estimated according to the model of Hiroyasu and Arai (1990):

$${\text{SMD}} = 4.12{\text{Re}}^{0.12} {\text{We}}^{ - 0.75} \left( {\frac{{\eta_{{\text{F}}} }}{{\eta_{{\text{A}}} }}} \right)^{0.54} \left( {\frac{{\rho_{{\text{F}}} }}{{\rho_{{\text{A}}} }}} \right)^{0.18} \times d_{{{\text{Nozzle}}}} .$$
(5)

The included properties of the ambient gas are the density ρA and the dynamic viscosity ηA.

The Reynolds and Weber numbers of the pure fuels at ambient conditions (293 K, 0.1 MPa) with a nozzle diameter of 168 µm and an estimated initial velocity of 120 m/s at the nozzle [derived out of (Storch et al. 2016c) at similar operating conditions] are given in Table 3.

Table 3 Reynolds and Weber numbers of the investigated fuels, 0.1 MPa, 293 K

The predicted SMDs according to the model of Hiroyasu and Arai are shown in Table 4 for the pure fuels and the investigated fuel blends (using mass-weighted averages of fuel properties). The estimation was deduced for the properties of the fuel at 0.1 MPa (Table 3) and the properties of air at 0.2 MPa (η= 18,29 µPa·s, ρA = 3,56 kg/m3; taken from Ref. VDI-Gesellschaft Verfahrenstechnik und Chemieingenieurwese (2013).

Table 4 Predicted SMDs according to the model of Hiroyasu and Arai, 0.1 MPa, 293 K

The predicted SMDs show the largest droplet size for ethanol followed by toluene and isooctane. For E20, slightly larger droplet sizes are predicted in comparison to Toliso. However, evaporation effects are not considered in these calculations. Ethanol, due to its lower evaporation temperature in comparison to isooctane and toluene, should evaporate faster. However, ethanol shows the highest evaporation enthalpy of all investigated fuels. This fact could lead to a strong cooling effect of the ambient gas, which could result in a reduced evaporation rate of the fuel droplets in these areas.

3 Results

In the first part of this section, the spray structure is analyzed using the SLIPI LIF/Mie technique. Afterwards, the LIF/Mie ratio is calibrated with suitable calibration curves using a droplet generator (Koegl et al. 2019c). The fuel-dependent spray shape is analyzed in terms of the cyclic variation. Finally, the calibrated droplet size distributions are compared to point-wise PDA measurements. A numerical simulation of evaporating single droplets is conducted for a discussion of different sources of error of the PDS-technique under conditions with low evaporation rate.

3.1 Spray structure analysis using single-shot LIF and Mie images

Single-shot images of the LIF- and the Mie-signals as well as the corresponding LIF/Mie-ratio of Toliso are shown in Fig. 3. The acquisition point in time is 1600 µs after electric start of injection (aESOI), which is relatively late during the injection event.

Fig. 3
figure 3

Single-shot images of the LIF- and Mie-signals and the corresponding LIF/Mie-ratio of Toliso, 1600 µs aESOI

The single-shot images enable a visualization of the turbulent spray structure, which is not possible with average images. The modulated laser light sheet enters the injection chamber from the left side and illuminates the central separated spray plume of the DISI-injector (compare Fig. 2). A comparison between the LIF- and the Mie-signals reveals that local high intensities are present in both channels. The corresponding LIF/Mie-ratio is largest at the spray front and at the radial spray edges, which corresponds to large droplet sizes. Aerodynamic forces are large at the spray front leading to a deceleration of the spray and a collision of fuel droplets and coalescence. This results in large droplets at the spray front, which are still present at late observation times. Inside the spray there are areas with low droplet densities (“cavities”), which are formed by the pulsating flow of the injector and the locally present large vortices. These areas are indicated by low LIF/Mie-ratios in their respective centers due to the presence of very small droplets. In general, these five images characterize cyclic variations of the spray structure very well. It is also important to note that the above-mentioned cavities appear very often at very similar positions in the sprays. This indicates that the turbulent spray motion is reproducible up to a certain point.

3.2 Calibration of the LIF/Mie ratio

The SMD distribution can be deduced from the LIF/Mie ratio measurements with an adequate calibration like the use of PDA data (Koegl et al. 2019a; Gal et al. 1999) or single droplet LIF/Mie data of a droplet generator (Domann and Hardalupas 2001b; Koegl et al. 2018b; Mishra et al. 2019). Here, the LIF/Mie ratios of Toliso and E20 sprays are quantified with single droplet calibration curves recorded by using a microscopic setup [for details see (Koegl et al. 2019c)]. Monodisperse droplets were studied in a diameter range of 20–50 µm using a droplet generator (type 1530, MSP Corp., Shoreview, USA). This selected diameter range is relevant for DISI-sprays. The lower adjusted droplet size is limited by the droplet generator. The LIF and Mie measurements were conducted approximately 3–7 mm below the exit of the droplet generator, which depends on the respective droplet size.

The individual droplets were evaluated regarding their sphericity, which is defined as the ratio of the minimum and maximum distance of the individual droplet. Other criteria were their location in the measurement region, and distance to neighboring droplets to clearly separate droplets from each other in the droplet chain. Only droplets with a sphericity between 1.0 and 1.2 were considered for further evaluation.

The calibration curves for the two investigated fuel mixtures with their uncertainty (standard deviation) of the micrometric droplets are shown in Fig. 4. Additionally, bin-wise averaged LIF and Mie-signals of the droplets are provided in the bottom rows (ddroplet ± 0.25 mm). In total, more than 30,000 single droplets were processed for each fuel. The fit curves show a similar behavior for both investigated fuels, while the uncertainty is slightly larger for Toliso in comparison to E20. For instance, the uncertainty of a 30 µm droplet is ± 20% for Toliso and ± 16% for E20.

Fig. 4
figure 4

Calibration curve of the experimental data using a droplet generator for Toliso and E20 (top). Corresponding bin-wise averaged LIF-signals of the droplets (bottom, ddroplet ± 0.25 µm, the intensity was normalized to the respective maximum signal to ensure visibility); Data were extracted from Koegl et al. (2019c)

The LIF/Mie ratios for both investigated fuels can be described by the following equations:

$$I_{{{\text{LIF/Mie\_Toliso}}}} = 0.0092 \times d_{{{\text{droplet}}}}^{{{1}{\text{.14}}}}$$
(6)
$$I_{{{\text{LIF/Mie\_E20}}}} = 0.0087 \times d_{{{\text{droplet}}}}^{{{1}{\text{.14}}}} .$$
(7)

Both fit curves show a very similar function with the same exponent and slightly different pre-exponential factors (Gal et al. 1999; Domann and Hardalupas 2003).

The microscopic LIF and Mie signals of single droplets will be discussed in brief. The bin-wise averaged droplets show a signal throughout the complete droplet. A larger LIF intensity can be observed in the center of the droplet. In the LIF-images, two bright spots at the left and two spots at the right side are generated. The focusing of the laser rays toward the right half side creates spots in the region opposite to the laser side. This is a dominant effect for small droplets (about 10–50 µm) and a weak absorption coefficient (Frackowiak and Tropea 2010b). Internal reflections create an illumination in the left part of the droplet. Details can be found in reference (Frackowiak and Tropea 2010b), in which a fluorescence model based on Lorenz–Mie theory and a ray-tracing method were utilized. In case of larger laser fluences (which is typically true for pulsed laser operation), MDRs (or cavity mode effects) occur inside the droplets. These ring-shaped structures occur at the outer region of the spherical droplets. These effects disappear when the droplets are slightly deformed. In general, the MDRs do not appear very pronounced and only few images show MDRs at all. Obviously, the MDR effect is less pronounced for the selected laser fluence, dye and droplet size range as well as dye concentration in comparison to droplet studies with pyrromethene 597-8C9 [see e.g. (Palmer et al. 2018)]. Slightly more distinct MDR-effects were observed for E20 in comparison to the base fuel Toliso (see Fig. 4, e.g. for 50 µm diameter). According to the literature, MDR-effects would cause a LIF exponent greater than three [in this study they were 3.03 (Toliso) and 3.34 (E20), respectively] and a Mie exponent greater than two (Gal et al. 1999) [here: 1,87 and 2.02 (E20), respectively; for details see Koegl et al. (2019c)]. The exponents of the resulting LIF/Mie ratios of the investigated fuels are both 1.14 and the presence of MDRs consequently does not show a significant impact on the LIF/Mie ratio.

Besides the uncertainties of the calibration data (see Fig. 4), further uncertainties have to be considered in the spray measurements. In principle, the LIF/Mie ratio does not depend on the laser fluence in the investigated range. Both the LIF and Mie signals showed a linear increase with larger laser fluence (up to 90 mJ/cm2) and no saturation effects were observed (Koegl et al. 2019c). The laser fluence of the SLIPI light sheet is 48 mJ/cm2 and it is thus considered uncritical regarding saturation of fluorescence and dissociation of the dye. A change of the liquid temperature as well as a change of the tracer concentration due to droplet heating and evaporation can lead to further uncertainties. While the change of the tracer concentration results in a nearly proportional variation of the LIF/Mie ratio, the temperature dependence strongly depends on the tracer-solvent combination. An earlier study revealed that the PDS technique based on Nile red dissolved in E20 shows a low temperature dependency at moderate temperatures (Koegl et al. 2019b). For example, a variation of the droplet temperature from 263 to 293 K leads to a variation of the LIF/Mie ratio of 9% for a droplet size of 30 µm (Koegl et al. 2019c). At higher temperatures, the LIF/Mie-ratio increases due to temperature-dependent absorption and emission behavior of the dye for a constant dye concentration. For example, the LIF/Mie-ratio is doubled for an increase from 293 to 323 K and a droplet size of 30 µm (100 mg/l Nile red in E20). Temperature and dye concentration effects on the PDS-measurement uncertainty during evaporation will be analyzed in a numerical study in Sect. 3.5 for the studied injection conditions.

A change in liquid composition (i.e. the toliso/ethanol ratio) due to preferential evaporation would change the LIF-intensity as well. However, as the LIF/Mie-ratio calibration curves are very similar for toliso and E20 (see Fig. 4), we believe that this effect is negligible at the present conditions.

3.3 Spray structure analysis using PDS

The quantified LIF/Mie ratios of the Toliso and E20 in terms of the SMD are shown in Fig. 5 (single shot images) and the corresponding average images and coefficient of variation (COV) images are exhibited in Figs. 6 and 7.

Fig. 5
figure 5

Single shot SMD images of Toliso (top) and E20 (bottom row), for 1200 µs aESOI

Fig. 6
figure 6

Quantified droplet size distribution SMD of Toliso (top) and E20 (bottom), at various times aESOI

Fig. 7
figure 7

Coefficient of variation (COV) of SMD for Toliso (top) and E20 (bottom), at various times aESOI

In the single shot images, large SMDs (about 45 µm) are present at the spray front and very often in the outer radial spray regions. Larger SMDs appear also close to the nozzle. There are no significant differences between Toliso and E20 in the range of measured droplet sizes.

The average images and the COV are calculated from 100 single images. The axial penetration depth is very similar for both fuels. The droplet sizes are very similar for the two fuels at 800 µs. E20 shows a slightly larger radial spray width and slightly larger droplet sizes at late observation times (2000 µs aESOI). The largest droplet sizes (≥ 30 µm) are located at the spray front and the adjacent radial spray edges. The droplet sizes in the spray center are in the range of 18–26 µm. These regions are relatively dilute due to the pulsating spray and appearing vortex cores (see single shot images in Fig. 5), which are created by the pulsating nozzle flow. These vortices are present in many single shot images (see Figs. 3 and 5). The spray appears slightly asymmetric, which can be assigned to the shot-to-shot variations in the spray shape, which show that the bend angle varies between the injections. Very often, the sprays are more bended to the “left” side (see Figs. 3 and 5), probably due to interactions with neighboring jets. Similar effects were also reported earlier for this injector but for another fuel (pure ethanol), see Mishra et al. (2019). In principle, both fuels show an increase of average droplet sizes with time, which needs further discussion.

The coefficient of variation (COV, which is the ratio of the standard deviation and the average value) of the SMD is used as an indicator of the cyclic variations of the highly turbulent spray. The COV does not exhibit significant changes with the observation time, see Fig. 7.

In general, the COV shows its smallest values in the spray center (0.8–1.5), since liquid fuel is always present in these regions. The biggest fluctuations of Toliso and E20 sprays occur at the spray front and radial boundaries (with COV values of up to 5), which are driven by the shot-to-shot variation of the axial and radial spray propagation. This strong variation can also be seen in the single shot images (see Fig. 5). The coefficient of variation shows no significant differences between E20 and Toliso.

3.4 Comparison of PDS-SMD with PDA-data

In this section, the SMDs derived from the SLIPI LIF/Mie-measurements are compared to point-wise PDA measurements. The LIF/Mie-ratio images and the corresponding PDA-measurement points for various observation times are shown in Fig. 8. The PDA data itself exhibit a similar spray structure in terms of SMD for Toliso and E20. At early observation times (1200 µs aESOI), the LIF/Mie SMDs show good agreement with the PDA-measurements. At later points in time, the PDA measured SMDs are smaller in comparison to the droplet sizes extracted from the LIF/Mie ratio, which increase with time.

Fig. 8
figure 8

SMD measured by SLIPI LIF/Mie overlaid with PDA-data for Toliso (top) and E20 (bottom) at various points in time aESOI

After 1600 µs, the overall droplet sizes determined by SLIPI LIF/Mie start to increase for both fuels, probably due to the progressing evaporation. This effect was not observed in earlier studies executed with ethanol and the dye Eosin Y (Koegl et al. 2019a; Mishra et al. 2019). Ethanol exhibits a lower evaporation rate, as its evaporation enthalpy is more than twice as high than those of Toliso and E20. This leads to a significantly lower dye enrichment for Ethanol in comparison to Toliso and E20 and finally to larger measurement uncertainties in the case of Toliso and E20. This aspect is further discussed in the subsequent paragraph.

In order to compare the two different fuels in detail, the LIF/Mie-ratio and the corresponding point wise PDA measurements are shown in Fig. 9 for various axial distances from the nozzle. These planes were chosen for comparison as here a relatively large number of droplets were evaluated in both PDA and PDS measurements especially at early points in time. The positions represent the main spray and the spray front at 1200 µs and 2000 µs aESOI. At 1200 µs, the PDS-measured SMDs are very similar for both fuels. At 40 mm (top left image in Fig. 9), the PDS-SMDs show a double-peak with variations for both fuels from about 15 µm in the center to 27 µm (at the left boundary). Similar SMDs were observed for both fuels at the spray front (55 mm) as well. At 2000 µs aESOI (top right in Fig. 9), the PDS-measured SMDs show larger droplets, which are on overage 22 µm in the spray center and 30 µm at the left boundary. In general, the spray plume of E20 is slightly wider in comparison to Toliso especially at 2000 µs. The droplet sizes derived from PDS show a slightly larger SMD for E20 in comparison to Toliso.

Fig. 9
figure 9

SMD deduced from calibrated SLIPI LIF/Mie-ratio (curves) and PDA data (points) of Toliso and E20 at 1200 µs and 2000 µs aESOI for various axial distances to the nozzle. The top line represents the main spray region while the bottom line depicts the spray front. Note the changed SMD-range of the y axis

The position 55 mm represents the spray front with SMDs from about 15–23 µm at 1200 µs aESOI. At 2000 µs, the spray front is at an axial distance of 70 mm from the nozzle at which the SMDs increase between 25 µm to 45 µm. At 2000 µs, the PDA-measured SMDs are smaller than at 1200 µs.

For comparison with PDA at discrete positions, the PDS-SMD values are averaged from 11 pixels in the respective line corresponding to about 400 µm. This averaging compensates the fluctuations in the PDS-SMD images for a fairer comparison. The PDA measurements showed a similar SMD for both fuels for all investigated observation times. The SMD at early observation points (1200 µs aESOI) is in a good agreement with the PDS-SMDs. The offset between PDA and PDS is relatively small for Toliso at 1200 µs and 40 mm: it is 0.0% (at R = − 5 mm), 11.3% (R = 0 mm) and 9.5% (R = 5 mm). Even at the spray front (55 mm), the difference is just 3.5%. For E20, the offset between PDA and PDS is 25.2% at 70 mm. At 40 mm, the offset is 29.5% (R = 0 mm), 1.3% (R = 5 mm) and 44.2% (R = − 5 mm). Probably, this large deviation at the left radial spray boundary is due to slight variations in the measurement position between PDA and PDS, which can hardly be quantified.

At 2000 µs the SMDs of Toliso and E20 derived from PDA are lower by about 50% on average in comparison to the PDS-SMD. Most probably, this behavior is mainly caused by the tracer enrichment due to the partially evaporating droplets. This effect will be discussed in Sect. 3.4. It should be also noted that the uncertainty of PDA measurements is usually in the range of at least 4% in spray regions without significant multiple scattering (i.e. dilute sprays) (Jermy and Greenhalgh 2000).

For a more detailed view on fuel-dependent spray behavior, normalized histograms of the PDA measured droplets sizes are exhibited for selected axial distances from the nozzle-tip for the complete temporal measurement interval in Fig. 10. The histograms show a very similar frequency distribution with no significant differences for both fuels. At 60 mm from the nozzle tip, for E20 the highest frequency probability is shifted to smaller droplets with increasing axial distance from the nozzle-tip. This effect might be caused by increased droplet evaporation, which is incorporated with turbulent droplet dispersion and increased air entrainment for larger axial distances from the nozzle-tip. E20 shows a slightly higher relative frequency for larger droplets (larger than 10 µm) than ethanol. However, this difference is smaller than expected from predictions of the model of Hiroyasu and Arai (1990) (see also Table 4). It can be concluded from PDA and PDS-SMD measurements that an ethanol addition of 20% has no distinct effect on atomization and just a small influence on evaporation for the studied injection conditions. Only few droplets between 20 µm and 30 µm were detected, which is different from the PDS data showing a significant number of larger droplets for later points in time (see Fig. 5). This discrepancy could be due to droplet deformation effects, which will introduce errors in both techniques. Especially larger droplets tend to be non-spherical, but they are not validated in PDA. Also, evaporation could lead to distinct errors of the PDS-measured SMD, which will be discussed in the subsequent sections.

Fig. 10
figure 10

Normalized droplet size histograms of Toliso and E20 for various axial distances from the nozzle-tip for the complete time interval measured by PDA (0.8–3 ms aESOI)

3.5 Simulation of droplet evaporation effects on the accuracy of the PDS technique

The evaporation effect on the accuracy of the PDS-technique has to be analyzed in detail. For this purpose, a numerical model is utilized that is capable to describe the different sources of error (such as temperature and dye concentration effects) on the accuracy of the PDS technique. Furthermore, the effect of the fuel properties on evaporation will be discussed here. On the one hand, ethanol has a lower boiling point than Toliso. On the other hand, the evaporation enthalpy of ethanol is three times larger than those of toluene and isooctane (see Table 2). These effects will result in a higher evaporation rate of Toliso and E20 in comparison to ethanol and can lead to larger systematic errors for the droplet size determination. As mentioned in Sect. 2.3, the model assumes isolated single droplets. This means that the evaporation rate will be larger than in a dense spray, which is characterized by locally higher vapor concentration between neighboring droplets. Since the real evaporation rate and the vapor concentration around the droplets are not known, the model results can be treated as a worst-case scenario for error estimations of the PDS-technique.

A considerable uncertainty factor is the droplet temperature. As the LIF-signal of Toliso and E20 is slightly temperature-dependent (Koegl et al. 2019b), an evaporation driven temperature change of the droplet can lead to further measurement uncertainties. The surface and core temperatures of the droplets with various sizes are shown in Fig. 11. In spite of different initial droplet sizes, similar temperatures during evaporation result for the respective fuel. After 1.2 ms, the smallest temperature drop (for 10 µm, 20 µm and 30 µm) is observed for Toliso (≈ 15 K) followed by ethanol (≈ 17 K) and E20 (≈ 20 K). Assuming a temperature drop of 20 K (from 293 to 273 K) would lead to a reduction in LIF intensity of about 2.3% (Toliso) and 5.1% (E20) (Koegl et al. 2019b). This would result in a similar change in the LIF/Mie-ratio (as the Mie-signal is just slightly temperature sensitive) and measured droplet size, respectively. For example, a 20 µm-droplet would be underestimated as 19.5 µm (Toliso) or 19.0 µm (E20).

Fig. 11
figure 11

Simulation of the surface and core temperature of evaporating fuel droplets for various initial droplet sizes and fuels. a Initial droplet diameter of 5 µm, b 10 µm, c 20 µm and d 40 µm

The initial reduction in droplet temperature is strongly dependent on the heat loss of the droplet through evaporation, which is in turn dependent on the evaporated fuel mass and the evaporation enthalpy of the different components. Figure 13 shows that the mixtures E20 and Toliso exhibit a similar rate of evaporation while E100 shows a much lower rate. The influence of the evaporation enthalpy is reflected in the simulated total heat loss due to evaporation for an initial droplet diameter of 10 µm, which is given in Fig. 12. The diagram shows the same correlation as the temperature profiles, where E20 has the highest total heat loss and the highest drop in temperature followed by E100 and Toliso.

Fig. 12
figure 12

Simulation of the total heat loss of evaporating 10 µm fuel droplets for various fuel mixtures, 293 K, 0.2 MPa

Another important uncertainty factor is the varying droplet size and dye concentration during evaporation. For this purpose, the droplet lifetime is calculated for Toliso, E20 and pure ethanol for different droplet sizes. Pure ethanol was chosen as an extreme case with a very low evaporation rate to discuss its influence on the droplet lifetime. Four relevant droplet size classes were simulated (5–40 µm). The most relevant initial droplet sizes for evaluation of the evaporation effect on the uncertainty are 10 µm and 20 µm for the main spray region as average SMD are typically larger than 10 µm (see Fig. 9). The evaporation effect on the droplet size is shown in Fig. 13.

Fig. 13
figure 13

Simulation of evaporating fuel droplets for various initial droplet sizes and for various fuel mixtures

The simulation results show an approximately double lifetime for ethanol for all simulated droplet sizes compared to Toliso and E20. E20 shows a slightly longer droplet lifetime in comparison to the base fuel Toliso due to the increase of the mixture evaporation enthalpy. Furthermore, already at 1.2 ms the droplet diameter of Toliso is reduced by 6.9% and 6.8% for E20 for an initially 10 µm large droplet (while the reduction is about 3.4% for ethanol). This could explain that the evaporation effect is less distinct at early residence times leading to similar PDS-measured SMD. However, at 2 ms, the droplet diameter is reduced by 11.2% for Toliso and 10.8% for E20 (while the reduction is about 3.4% for ethanol). Furthermore, the evaporation rate of E20 is still lower, which could partially explain the slightly larger droplets for E20 measured with SLIPI LIF/Mie and PDA at 2000 µs. The evaporation of Toliso and E20 leads to an increase of the dye concentration within the droplets. The time dependent dye concentrations in the respective droplets are given in Fig. 14.

Fig. 14
figure 14

Simulation of the tracer concentration in evaporating fuel droplets for various initial droplet sizes and fuel mixtures

The dye enrichment is a serious systematic error, which is distinct especially for small droplet sizes (e.g. 5 µm) occurring already after 100 µs. For a 10 µm droplet, the dye enrichment is significant after 1.2 ms: For Toliso and E20, the dye concentration rises for a 10 µm droplet by 20.4% (5 µm: 156.0% (Toliso), 140.8% (E20); 20 µm: 6.2% (Toliso and E20); 40 µm: 3.1% (Toliso and E20)), which would result in an overestimation of the droplet size measured via PDS of the same percentage as well. For pure ethanol, this effect is less pronounced (5 µm: 46.3%; 10 µm: 13.0%; 20 µm: 3.1%; 40 µm: 3.1%) due to its high evaporation enthalpy, which was also confirmed in previous measurements (Koegl et al. 2018b; Mishra et al. 2019). This means that large deviations between PDA and PDS can be mainly explained by dye enrichment. As the average SMD is in the range of 10–20 µm, the dye enrichment would introduce errors between about 6–20% for the present spray at 1.2 ms, assumed that the LIF-signal is proportional to the dye concentration. Previous investigations (Koegl et al. 2019c) showed, that the LIF/Mie-ratio of Nile red dissolved in E20 increases linearly with increasing dye-concentration. The study revealed that the varied absorption due to the dye concentration can be neglected up to 200 mg/l. However, it should be noted that PDA would also introduce uncertainties in the range of at least 4% in dilute spray regions without significant multiple scattering (Jermy and Greenhalgh 2000). Furthermore, for unsteady sprays, the PDA-technique may provide very low measurement data rates in regions with low droplet concentrations (Fdida et al. 2010). This may result in a bias of average SMD in case that only few droplets can be collected, which is especially problematic when short time intervals are analyzed in terms of a temporal spray analysis.

It can be concluded that with the present PDS-concept, a reliable droplet size determination is only possible at moderate temperatures (e.g. low evaporation rates) in combination with short residence times. It seems feasible that, however, e.g., in combination with suitable numerical modeling the PDS approach may be extended also to situations where significant evaporation occurs.

4 Conclusion

The spray structure of a gasoline DISI injector was analyzed in terms of droplet sizes (SMD). The surrogate gasoline Toliso (65 vol.% isooctane, 35 vol.% toluene) and the ethanol blend E20 (80 vol.% Toliso, 20 vol.% ethanol) were studied with planar droplet sizing using the fluorescence tracer Nile red. The qualitative LIF/Mie ratio of the DISI-spray was calibrated with suitable calibration curves from an earlier investigation (Koegl et al. 2019c) with a droplet generator. The DISI-spray was recorded using the 2p-SLIPI technique to effectively suppress multiple light scattering. The investigated droplet sizes in the sprays were in the range of 5 µm up to 30 µm and larger. The largest droplet sizes were located at the spray front and the lateral spray edges. An analysis of the spray fluctuations showed similar results for both investigated fuels. The highest fluctuations occur at the spray front and the lateral spray edges. Under the studied injection conditions, the SMDs of the Toliso and E20 sprays were similar and no pronounced fuel-dependent atomization was observed. The PDS and PDA measurements showed very similar SMD at short residence times (i.e. up to 1.2 ms) at which evaporation is less distinct. At later observation times (i.e., 2 ms) E20 showed an increased number of slightly larger droplets in PDA measurements. The offset between the PDS- and PDA- measured SMDs was in the range of 10% at 1.2 ms. For longer residence times and an increased evaporation rate, the deviation between PDA- and PDS-measured SMD increased to roughly 50%. A partial evaporation of the droplets leads to an enrichment of the tracer concentration resulting in large systematic errors of the measured SMD. A numerical simulation of single droplets showed that distinct tracer enrichment in the droplets occurs already after 1.2 ms. This would result in an overestimation of the SMD in the range of about 6% for initially 20 µm large droplets and of about 20% for 10 µm large droplets, respectively. A temperature drop due to evaporation results in an error of the SMD in the range of 5% under the studied conditions. Hence, the PDS-technique used in the present study is only applicable for operating conditions at which reduced evaporation occurs. The numerical simulation of isolated single droplets predicts faster evaporation than in a spray. Consequently, the model represents a worst-case scenario as the dye concentration in the droplet would be over-estimated for a given droplet lifetime. The model thus gives an upper bound for the uncertainty. The PDS technique should be expanded in the future regarding a combined application of experimental and numerical approaches.