Abstract
Objectives
This study analyzed the prevalence and pattern of focal and potential diffuse myocardial fibrosis detected by late gadolinium enhancement (LGE) and extracellular volume (ECV) imaging in male and female marathon runners using cardiac magnetic resonance (CMR).
Methods
Seventy-four marathon runners were studied including 55 males (44 ± 8 years) and 19 females (36 ± 7 years) and compared to 36 controls with similar age and sex using contrast-enhanced CMR, exercise testing, and blood samples.
Results
Contrast-enhanced CMR revealed focal myocardial fibrosis in 8 of 74 runners (11%). The majority of runners were male (7 of 8, 88%). LGE was typically non-ischemic in 7 of 8 runners (88%) and ischemic in one runner. ECV was higher in remote myocardium without LGE in male runners (25.5 ± 2.3%) compared to male controls (24.0 ± 3.0%, p < 0.05), indicating the potential presence of diffuse myocardial fibrosis. LV mass was higher in LGE + males (86 ± 18 g/m2) compared to LGE- males (73 ± 14 g/m2, p < 0.05). Furthermore, LGE + males had lower weight (69 ± 9 vs 77 ± 9 kg, p < 0.05) and shorter best marathon finishing times (3.2 ± 0.3 h) compared to LGE- males (3.6 ± 0.4 h, p < 0.05) suggesting higher training load in these runners to accomplish the marathon in a short time.
Conclusion
The high frequency of non-ischemic myocardial fibrosis in LGE + male runners can be related to increased LV mass in these runners. Furthermore, a higher training load could explain the higher LV mass and could be one additional cofactor in the genesis of myocardial fibrosis in marathon runners.
Key Points
• A high frequency of myocardial fibrosis was found in marathon runners.
• Myocardial fibrosis occurred typically in male runners and was typically non-ischemic.
• Higher training load could be one cofactor in the genesis of myocardial fibrosis in marathon runners.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Regular physical activity is generally considered beneficial for the cardiovascular system and is associated with improvement in physiological parameters [1]. Recent reports, however, have drawn attention to possible adverse cardiac effects and increased risk of sudden cardiovascular death events in runners [2,3,4]. At this current time, there is an incomplete understanding of the relationship between physiological cardiovascular adaption to physical exertion (so-called athletes’ hearts) and potential negative effects due to vigorous exercise [5, 6].
It is recognized that late gadolinium enhancement (LGE) quantified by cardiac magnetic resonance (CMR) imaging occurs in both acute and chronic (scar) infarctions and in an array of other myocardial processes that cause myocardial necrosis, infiltration, or fibrosis [7]. These myocardial processes include myocarditis, hypertrophic cardiomyopathy, amyloidosis, sarcoidosis, and other myocardial conditions [7]. T1 mapping and extracellular volume (ECV) imaging are able to analyze and quantify the increase of extracellular space in various cardiac diseases [8]. It has been shown in patients with left ventricular hypertrophy related to hypertensive heart disease or hypertrophic cardiomyopathy that ECV correlated with a histologically determined degree of myocardial fibrosis [9, 10]. Recent CMR studies in athletes used ECV imaging to study matrix remodeling and the potential presence of diffuse myocardial fibrosis which is not detected by standard LGE [11,12,13,14].
Previous CMR studies showed a high prevalence of focal myocardial fibrosis in up to 50% of asymptomatic athletes with still controversial clinical relevance [15,16,17,18]. Lifetime amount of exercise, exercise-induced hypertension, and clinically undetected myocarditis were proposed as possible cofactors in the pathogenesis of myocardial scarring [18]. In many cardiac diseases including myocarditis myocardial scar tissue is a risk factor for cardiac arrhythmia and sudden cardiac death [19]. Therefore, a deeper understanding of the causes and clinical relevance of myocardial fibrosis in asymptomatic runners is warranted. Previous CMR studies examined the presence of LGE in marathon runners [5, 20]. However, these studies did not include competitive female runners for comparison, limiting the information about myocardial fibrosis in the growing group of female runners.
The present study analyzed the prevalence and pattern of focal and potential diffuse myocardial fibrosis detected by LGE and ECV in male and female marathon runners using contrast-enhanced CMR.
Materials and methods
Ethics and study design
This prospective single-center observational study was approved by the local institutional ethics committee. All subjects gave written informed consent before study participation. The study was performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments.
Study population
Male and female marathon runners were contacted through advertisements at local running clubs. They were included with a self-reported regular training of at least 10 h per week and a history of at least one completed marathon race. A standard questionnaire was used to assess the weekly training load and lifetime competition history, including completed marathons and finishing times. The best marathon finishing time referred to a marathon distance of 42.195 km defined by World Athletics. Each runner completed at least one marathon with that distance and reported the corresponding finishing time. Controls with similar age and sex were eligible if they exercised less than 3 h per week. Subjects with contraindications for CMR were excluded. All subjects reported no cardiovascular disease and all subjects denied any cardiac or illicit medication intake. All subjects underwent the CMR study before the exercise test, which was performed on the same day. Subjects were instructed to arrive rested with no exercise and no alcohol intake in the preceding 72 h. Any food and caffeine intake was restricted in the preceding 3 h before the CMR and the exercise test was performed 3 h after the CMR.
Exercise testing and blood samples
Cardiopulmonary exercise testing was performed on the same day after CMR using an eddy current braked cycle ergometer (Ergoselect 100, Ergoline GmbH) to determine maximal oxygen uptake (VO2max) and ventilatory threshold. A 12-lead electrocardiogram and heart rate were monitored continuously, and blood pressure was automatically measured every 2 min. The ramp incremental step-exercise test was preceded by a 2-min rest period and unloaded cycling (20 W for 3 min), until a steady state was attained. Depending on the subject´s training history, the ramp was continuously increased by 20 to 40 W/min to bring the participants to the limit of tolerance within 10 to 12 min of exercise.
Blood samples were drawn immediately before the CMR from an antecubital vein in a supine position for 5 min. to obtain hematocrit, creatine kinase, high-sensitive troponin T, and N-terminal pro-brain natriuretic peptide (NT-proBNP).
CMR protocol
Runners and controls underwent CMR imaging with a 1.5-T Achieva Scanner (Philips Healthcare), using a 5-element cardiac coil and ECG gating. Conventional balanced steady-state free-precession (SSFP) cine imaging in the short axis covering the left ventricle (LV) and right ventricle (RV) was obtained for volumetry and LV mass. A Modified Look-Locker Inversion Recovery (MOLLI) sequence with a 5 s(3 s)3 s scheme on 3 short-axis slices (apical, mid, and basal) before and 15 min after administration of contrast medium was used to perform T1 mapping and ECV quantification. Additionally, after 10 min of a bolus injection of 0.2 mmol/kg gadoterate meglumine (Dotarem, Guerbet), end-diastolic LGE images were acquired with standard phase-sensitive inversion recovery (PSIR) sequences in short axis orientation and in 2-, 3-, and 4-chamber views matching cine images. Details about the scanning protocol were previously reported [21].
CMR data analysis
Two experienced observers (M.A. experience > 10 years; L.B. experience > 4 years in reading CMRs) independently and blindly analyzed CMR images using cvi42 software (Circle Cardiovascular Imaging Inc.). CMR parameters were normalized to the subject’s calculated body surface area (BSA) and are given as the mean of the two investigators’ measurements. LV and RV volumes and LV mass were measured on short-axis cine images as previously described [22]. Focal myocardial fibrosis was identified on short- and long-axis LGE images and considered present using a threshold method with a cutoff of more than five SDs above normal myocardium [22]. The distribution and pattern of LGE were visually analyzed and reported using a 17-segment model. Native T1 and post-contrast T1 were measured using a single ROI drawn in the septum on a mid-cavity short-axis map and ECV was calculated by the standard formula [23]. Areas of focal LGE were excluded from T1 and ECV quantification to evaluate these parameters unbiased from the presence of LGE [21].
Statistical analysis
Statistical analysis was performed using GraphPad Prism for MacOS, Version 9.1.1 (GraphPad Software Inc.). All MR imaging data are presented as means of the measurements from two blinded readers. The normality of the data was assessed by Shapiro–Wilk test. Continuous data are presented as mean ± SD, and categorical data are presented as absolute numbers and percentages. Continuous variables were compared between groups using unpaired 2-sided student’s t-tests. For categorical data, the chi-square test or Fisher’s exact test was used as appropriate. Statistical significance was defined as p < 0.05.
Results
Demographics and CMR characteristics of marathon runners and controls
A total of 74 marathon runners including 19 female runners were enrolled in this study between April 2014 and October 2016. The mean age of the study population was 44 ± 8 years in males and 36 ± 7 years in females, respectively. Another 36 control subjects with a similar distribution of age and sex were included for comparison. Both male and female runners had better performance in exercise tests with higher maximal power and higher VO2max as compared to controls (Table 1). CMR revealed higher LV mass and LV volumes in runners compared to controls. Furthermore, native T1 was lower in male and female runners compared to controls, whereas ECV was higher in male runners at 25.5 ± 2.3% compared to male controls with 24.0 ± 3.0% (p < 0.05, Table 1).
Prevalence, pattern, and localization of LGE
CMR showed focal myocardial fibrosis in 8 of 74 runners (11%) and the majority of these 8 LGE + runners were male (7 of 8, 88%). The prevalence of LGE was 7 in 55 male runners (13%) and one in 19 female runners (5%), however, the LGE difference between both genders was not significant (p = 0.14). No LGE was detected in the controls. LGE was midmyocardial or subepicardial localized in 7 of 8 runners (88%). One runner had subendocardial LGE typical for myocardial infarction (runner 12) (12%, Fig. 1). Non-ischemic LGE was present in 5 runners at the anterior or posterior RV insertion point (63%, runners 8, 32, 38, 52, 58), in the inferior-lateral wall in 2 runners (25%, runners 35, 60), and in one runner with ischemic LGE in the anterior wall (12%, runner 12). Runner 38 was the single female runner with LGE, which was located at the anterior and posterior RV insertion points. The mean size of LGE was 2.5 ± 1.8%LV (range 1.0–5.4%LV) and 1.9 ± 1.8 g/m2 (range 0.5–5.0 g/m2) in male LGE + runners and 2.2%LV and 1.2 g/m2 in the one female LGE + runner (Table 1). The 8 LGE + runners had 20 myocardial segments with LGE (mean 2.5 ± 1.5 segments, ranges 1–6). Figure 2 shows segmental LGE distribution in 8 LGE + runners.
Differences between LGE + and LGE- male marathon runners
LGE + males (n = 7) had lower weight (69 ± 9 vs 77 ± 9 kg, p < 0.05), lower body surface area (1.85 ± 0.15 vs 1.97 ± 0.14 m2, p < 0.05), and lower body mass index (21.7 ± 1.9 vs 23.3 ± 1.8 kg/m2, p < 0.05) compared to LGE- males (Table 2). The heart rate at rest was slightly higher before the exercise test with 60 ± 10 beats per minute compared to LGE- males with 52 ± 7 beats per minute (p < 0.05, Table 2). LV mass was higher in LGE + males with 85 ± 17 g/m2 compared to LGE- runners with 74 ± 10 g/m2 (p < 0.05). All other standard CMR parameters including LVEF, LV, and RV volumes were similar between groups. Furthermore, native T1 and ECV values were not different in both groups indicating no incremental potential diffuse myocardial fibrosis in LGE + males. The competition history revealed that the best marathon finishing time was with 3.2 ± 0.3 h shorter in LGE + males compared to LGE- males with 3.6 ± 0.4 h (p < 0.05). All other training and competition history parameters were similar in both groups.
Discussion
The current study investigated focal and potential diffuse myocardial fibrosis detected by LGE and ECV imaging in male and female marathon runners using contrast-enhanced CMR. The main findings of our study were that eight of 74 runners (11%) had LGE, which was typically non-ischemic with midmyocardial or subepicardial localization (7 of 8 runners, 88%). ECV was slightly higher in male runners compared to controls in remote myocardium without LGE indicating the potential presence of diffuse myocardial fibrosis. LGE + males had higher LV mass compared to LGE- males, indicating a more pronounced adaption of the heart to exercise. LGE + males had lower weight at similar height compared to LGE- males, revealing a more asthenic build in these runners. LGE + males had a shorter best marathon finishing time suggesting a better fitness level for these runners, although exercise testing revealed no difference in performance measured by VO2max and maximal power.
Prevalence, pattern, and localization of LGE
The prevalence of myocardial fibrosis by LGE was 11% in all marathon runners and 13% in male runners in the current study. The current LGE prevalence is somewhat lower compared to a previous study with 17% in male LGE + triathletes [21]. Furthermore, we found one LGE + female marathon runner compared to none females in triathletes [21]. Our data indicate that male runners are more prone to myocardial fibrosis compared to females, however, the LGE difference between both genders was not significant (p = 0.14). One potential explanation is viral myocarditis, which involves males twice as often as females [24]. Despite the fact that all current subjects reported no cardiovascular disease clinically silent or unrecognized myocarditis cannot be excluded per se. In fact, previous work pointed out that elite athletes seem to have an increased risk of viral infection and subsequent myocarditis due to increased exposure to pathogens related to worldwide traveling and international competition or impaired immune system related to continuing training during infections or resuming training early thereafter, strenuous exercise training or competition, and exercising in extreme weather conditions [25]. This assumption for elite athletes could also be true for non-elite athletes.
Besides myocarditis, other factors can be responsible for the preferential occurrence of myocardial fibrosis in males. LGE at the RV insertion points is a frequent finding in patients with pulmonary hypertension [26]. Currently, 63% of our LGE + males had LGE at the anterior or posterior RV insertion point compared to 22% of male triathletes [21]. A previous meta-analysis suggested that besides genetic predisposition and silent myocarditis, pulmonary artery pressure overload and prolonged exercise-induced repetitive microinjury contribute to the development of myocardial fibrosis in runners [18]. Therefore, it is possible that runners develop LGE at the RV insertion points due to exercise-induced pulmonary artery pressure overload resulting in repetitive microinjury. Prior studies pointed out the occurrence of exercise-induced RV cardiomyopathy, which is related to high wall stress of the RV during intense sports, leading to cellular disruption and the release of cardiac enzymes [27, 28]. Our data indicate that myocardial fibrosis at the RV insertion points could be a sequela of the high wall stress of the RV during intense sports. Our CMR data were obtained at rest with no exercise in the preceding 72 h, revealing similar RV volumes in LGE + and LGE- males. Therefore, it is possible that we missed RV dilatation, which typically occurs immediately after exercise [27]. Furthermore, myocardial fibrosis at the RV insertion point may precede significant RV dilation.
The mean size of LGE was smaller in our male runners with 2.5 ± 1.8%LV and 1.9 ± 1.8 g/m2 compared to previously studied male LGE + triathletes with 3.5 ± 2.8%LV and 2.9 ± 2.3 g/m2 [21]. Our data suggest that runners have less frequent and smaller sizes of LGE compared to triathletes, including iron man participants. This finding could be explained by lower training volume in marathon runners compared to triathletes. Accordingly, a previous study showed that marathon runners have significantly shorter weekly training times and shorter competition times compared to iron man participants [29].
ECV was slightly increased in male runners with 25.5 ± 2.3% compared to controls with 24.0 ± 3.0% in remote myocardium without LGE indicating the potential presence of diffuse myocardial fibrosis. One explanation could be hypertensive heart disease, where there is an expansion of both the myocyte volume resulting from myocyte hypertrophy (intracellular) as well as the interstitial space resulting from fibrosis (extracellular) [30]. However, it has to be stated that the ECV differences were small between the two groups and measurements were within the normal range of ECV measurements. Additionally, our findings about ECV in athletes are different from the data by Swoboda et al. who found decreased ECV values in athletes at 22.7 ± 3.3% compared to controls with 24.3 ± 2.6% [12]. The reasons for these discrepancies in ECV values and the clinical relevance of the observed ECV alterations finding are currently unclear and need further investigation.
One runner had subendocardial LGE typical for myocardial infarction and he received secondary prevention medication. This runner was not aware of having coronary heart disease and he was asymptomatic during exercise and competition. Therefore, we did not recommend invasive or computed tomography coronary angiography for further testing.
Differences between LGE + and LGE- male marathon runners
LGE + males had lower weight at similar height compared to LGE- males, revealing a more asthenic build in these runners. This finding could be explained by more intensive training in LGE + males, although our standard questionnaire revealed no differences in the weekly training load and the number of active years. However, we found that the best marathon finishing time was shorter in LGE + males compared to LGE- males suggesting a higher fitness level most likely related a more intensive training in these runners. Our standard questionnaire was not designed to document the exact training load before a competition and limited a detailed analysis of the impact of training on the occurrence of LGE. For example, the individual training volume and intensity varies between runners and depends on multiple factors such as motivation, health condition, available time, and so forth. Therefore, a more exact documentation of the individual training absolved by the athlete could be helpful to better understand the training differences in LGE + and LGE- athletes and the impact of training on LGE in athletes in general. The training regimen of athletes is most likely the more important aspect to further study on, since training repeatedly consumes much more time and effort, compared to the “relatively short” marathon distance during one competition.
LV mass was higher in LGE + males compared to LGE- males. A similar finding was previously reported in triathletes [21]. Currently, the exact mechanism for the development of myocardial scarring in athletes is unclear. A previous study suggested that increased systolic blood pressure during exercise and race distances could be cofactors in the origin of myocardial fibrosis [21]. Furthermore, patients with hypertensive heart disease frequently develop non-ischemic myocardial fibrosis [31]. The observed increased LV mass in combination with non-ischemic LGE in our runners could be an expression of hypertensive heart disease, a condition that is so far not related to the athlete´s heart.
Limitations
We used a standard questionnaire to assess the self-reported training load in our runners. Currently, more precise techniques are available to assess physical activity during training such as quantifying the metabolic equivalent (MET), which was developed to enhance the comparability of results across studies using self-reported physical activity [32]. Future studies are needed to focus on the impact of training on the development of myocardial fibrosis in athletes.
Conclusions
The current study revealed typically non-ischemic myocardial fibrosis in 7 of 55 (13%) male marathon runners and in one of 19 female runners (5%). Furthermore, we found slightly higher ECV in remote myocardium without LGE in male runners compared to controls demonstrating the potential presence of diffuse myocardial fibrosis possibly related to hypertensive heart disease. No ECV differences were found in female runners and controls. LGE + males had higher LV mass compared to LGE- males, indicating a more pronounced adaption of the heart to exercise. Furthermore, LGE + males had lower weight and shorter best marathon finishing time suggesting a better fitness level and higher training load to accomplish the marathon in a short time. The higher training load can explain the higher LV mass and could be one additional cofactor in the genesis of myocardial fibrosis in athletes. Since the clinical relevance of the observed myocardial fibrosis is currently not clear we did not give any specific recommendation to reduce the individual sports practice in LGE + runners. Further studies are needed to analyze the impact of training load on the occurrence of myocardial fibrosis in athletes and the long-term relevance of myocardial fibrosis on left ventricular function and on the occurrence of relevant cardiac arrhythmia.
Data Availability
The data of the current study are available upon reasonable request.
Abbreviations
- CMR:
-
Cardiac magnetic resonance
- ECV:
-
Extracellular volume
- LGE :
-
Late gadolinium enhancement
- LGE-:
-
Runner without LGE
- LGE + :
-
Runner with LGE
- LV:
-
Left ventricle
- MET:
-
Metabolic equivalent
- MOLLI:
-
Modified Look-Locker Inversion Recovery
- NT-proBNP :
-
N-terminal pro-brain natriuretic peptide
- RV :
-
Right ventricle
- SSFP :
-
Steady-state free-precession
- VO2max :
-
Maximal oxygen uptake
References
Haskell WL, Lee I-M, Pate RR et al (2007) Physical activity and public health: updated recommendation for adults from the American College of Sports Medicine and the American Heart Association. Circulation 116:1081–1093.
Corrado D, Zorzi A (2017) Sudden death in athletes. Int J Cardiol 237:67–70
Levine BD (2014) Can intensive exercise harm the heart? The benefits of competitive endurance training for cardiovascular structure and function. Circulation 130(12):987–991
Marijon E, Tafflet M, Celermajer DS et al (2011) Sports-related sudden death in the general population. Circulation 124(6):672–681
Breuckmann F, Möhlenkamp S, Nassenstein K et al (2009) Myocardial late gadolinium enhancement: prevalence, pattern, and prognostic relevance in marathon runners. Radiology 251(1):50–57
Maron BJ (2000) The paradox of exercise. N Engl J Med 343(19):1409–1411
Ordovas KG, Higgins CB (2011) Delayed contrast enhancement on MR images of myocardium: past, present, future. Radiology 261(2):358–374
Robinson AA, Chow K, Salerno M (2019) Myocardial T1 and ECV Measurement. JACC Cardiovasc Imaging 12(11):2332–2344
Kammerlander AA, Marzluf BA, Zotter-Tufaro C et al (2016) T1 Mapping by CMR imaging: from histological validation to clinical implication. JACC Cardiovasc Imaging 9:14–23.
Diao K-Y, Yang Z-G, Xu H-Y et al (2016) Histologic validation of myocardial fibrosis measured by T1 mapping: a systematic review and meta-analysis. J Cardiovasc Magnetic Reson 18:92
McDiarmid AK, Swoboda PP, Erhayiem B et al (2016) Athletic cardiac adaptation in males is a consequence of elevated myocyte mass. Circ Cardiovasc Imaging 9:e003579
Swoboda PP, McDiarmid AK, Erhayiem B et al (2016) Assessing myocardial extracellular volume by T1 mapping to distinguish hypertrophic cardiomyopathy from athlete’s heart. J Am Coll Cardiol 67(18):2189–2190
Tahir E, Starekova J, Muellerleile K et al (2018) Myocardial fibrosis in competitive triathletes detected by contrast-enhanced CMR correlates with exercise-induced hypertension and competition history. JACC Cardiovasc Imaging 11:1260–1270
Domenech-Ximenos B, Garza MS la, Prat-González S et al (2020) Prevalence and pattern of cardiovascular magnetic resonance late gadolinium enhancement in highly trained endurance athletes. J Cardiovasc Magnetic Reson 22:62
Bohm P, Schneider G, Linneweber L et al (2016) Right and left ventricular function and mass in male elite master athletes: a controlled contrast-enhanced cardiovascular magnetic resonance study. Circulation 133(20):1927–1935
Abdullah SM, Barkley KW, Bhella PS et al (2016) Lifelong physical activity regardless of dose is not associated with myocardial fibrosis. Circ Cardiovasc Imaging 9:e005511
Wilson M, O’Hanlon R, Prasad S et al (2011) Diverse patterns of myocardial fibrosis in lifelong, veteran endurance athletes. J Appl Physiol (1985) 110(6):1622–1626
van de Schoor FR, Aengevaeren VL, Hopman MTE et al (2016) Myocardial fibrosis in athletes. Mayo Clin Proc 91(11):1617–1631
Greulich S, Seitz A, Müller KAL et al (2020) Predictors of mortality in patients with biopsy-proven viral myocarditis: 10-year outcome data. J Am Heart Assoc 9:e015351
Möhlenkamp S, Lehmann N, Breuckmann F et al (2008) Running: the risk of coronary events : Prevalence and prognostic relevance of coronary atherosclerosis in marathon runners. Eur Heart J 29(15):1903–1910
Tahir E, Scherz B, Starekova J et al (2020) Acute impact of an endurance race on cardiac function and biomarkers of myocardial injury in triathletes with and without myocardial fibrosis. Eur J Prev Cardiol 9:27:94–104
Schulz-Menger J, Bluemke DA, Bremerich J et al (2013) Standardized image interpretation and post processing in cardiovascular magnetic resonance: society for Cardiovascular Magnetic Resonance (SCMR) board of trustees task force on standardized post processing. J Cardiovasc Magn Reson 15:35
Messroghli DR, Moon JC, Ferreira VM et al (2017) Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: a consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J Cardiovasc Magn Reson 19:75
Cocker MS, Abdel-Aty H, Strohm O, Friedrich MG (2009) Age and gender effects on the extent of myocardial involvement in acute myocarditis: a cardiovascular magnetic resonance study. Heart 95(23):1925–1930
Halle M, Binzenhöfer L, Mahrholdt H, Schindler MJ, Esefeld K, Tschöpe C (2020) Myocarditis in athletes: a clinical perspective. Eur J Prev Cardiol 28(10):2047487320909670
Swift AJ, Rajaram S, Capener D et al (2014) LGE patterns in pulmonary hypertension do not impact overall mortality. JACC Cardiovasc Imaging 7:1209–1217
Claessen G, Claus P, Ghysels S et al (2014) Right ventricular fatigue developing during endurance exercise: an exercise cardiac magnetic resonance study. Med Sci Sports Exerc 46(9):1717–1726
Heidbüchel H, Gerche AL (2012) The right heart in athletes. Evidence for exercise-induced arrhythmogenic right ventricular cardiomyopathy. Herzschrittmacherther Elektrophysiol 23:82–86
Esteve-Lanao J, Moreno-Pérez D, Cardona CA et al (2017) Is Marathon training harder than the ironman training? An ECO-method Comparison. Front Physiol 8:298
Kuruvilla S, Janardhanan R, Yang Y et al (2014) Increased extracellular volume and altered mechanics are associated with left ventricular hypertrophy in hypertensive heart disease, not hypertension alone. J Cardiov Magn Reson 16(Suppl 1):P393–P393
von Knobelsdorff-Brenkenhoff F, Mueller A-K, Prothmann M et al (2016) Cardiac fibrosis in aortic stenosis and hypertensive heart disease assessed by magnetic resonance T1 mapping. J Heart Valve Dis 25(5):527–533
Ainsworth BE, Haskell WL, Herrmann SD et al (2011) 2011 Compendium of physical activities: a second update of codes and MET values. Med Sci Sports Exerc 43(8):1575–1581
Funding
Open Access funding enabled and organized by Projekt DEAL. The authors state that this work has not received any funding.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Guarantor
The scientific guarantor of this publication is Gunnar K. Lund.
Conflict of interest
The authors of this manuscript declare relationships with the following companies:
Dr. Christian Stehning is an employee of Philips Clinical Science, Hamburg, Germany.
Gunnar K. Lund had full control of the data and the material submitted for publication.
Statistics and biometry
No complex statistical analysis was performed in this work requiring dedicated statistical support.
Informed consent
Written informed consent was obtained from all subjects in this study.
Ethical approval
Institutional Review Board approval was obtained.
Methodology
• prospective
• observational
• performed at one institution
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ragab, H., Lund, G.K., Breitsprecher, L. et al. Prevalence and pattern of focal and potential diffuse myocardial fibrosis in male and female marathon runners using contrast-enhanced cardiac magnetic resonance. Eur Radiol 33, 4648–4656 (2023). https://doi.org/10.1007/s00330-023-09416-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-023-09416-3